Thermal Engineering
Raise an engine's compression ratio until knock stops you, choke a steam nozzle, and watch a Morse test find the friction power of an engine
22 chapters, 22 interactives, few words. Every chapter is mapped to the Anna University, VTU, SPPU, Mumbai University and KTU units it covers: air-standard Otto, Diesel, dual and Brayton cycles, fuel-air and actual cycles, gas turbines with regeneration, intercooling and reheat, jet propulsion, steam properties and boilers, Rankine, reheat and regenerative cycles, steam nozzles, impulse and reaction turbines, IC engines, fuels and combustion air, combustion and knock, emissions and Bharat Stage norms, engine performance and testing, reciprocating and multistage compressors, refrigeration and psychrometry.
- AUME3451Thermal Engineering
- VTUBME401Applied Thermodynamics
- SPPU202048Applied Thermodynamics
- MUMEC305Thermodynamics (Modules 4-6)
- MUMEC502Thermal Engineering (Modules 5-6)
- KTUPBMET604Thermal Engineering
By Skill-Lync · Updated 18 Nov 2026 · 22 chapters · 22 interactives · free, no sign-up
Air-standard cycles: Carnot and Otto, efficiency and mean effective pressure
Which syllabus covers thisAU ME3451 Unit IVTU BME401 Module 1SPPU 202048 Unit IIMU MEC305 Module 5KTU PBMET604 Module 3
What does an air-standard cycle assume, and why bother with it?
It replaces the messy engine by a clean thought experiment. The working fluid is air only, an ideal gas with constant cp 1.005, cv 0.718 and R 0.287 kJ/kg K, so γ = 1.4. Burning fuel becomes heat added from outside, the exhaust stroke becomes heat rejected to the surroundings, and every process is reversible. The same kilogram of air goes round a closed loop. The numbers come out too high, but the trends are right: which way efficiency moves with compression ratio, cut-off or pressure ratio, and why.
What are bore, stroke, swept volume, clearance volume and compression ratio?
Bore d is the cylinder diameter and stroke L the piston travel between top and bottom dead centre. Swept volume is Vs = (π/4) d² L. Clearance volume Vc is the space left above the piston at top dead centre. Compression ratio r = (Vs + Vc)/Vc, the total volume over the clearance volume. A single-cylinder 150 cc engine with a 57 mm bore and 58.6 mm stroke (illustrative) sweeps 149.5 cc; for r = 9.5 its clearance volume is Vs/(r − 1) = 17.6 cc.
Why is the Carnot cycle the upper limit, and why does no engine run on it?
Between a coldest temperature T1 and a hottest T3 no cycle can beat η = 1 − T1/T3, and Carnot reaches it by taking in all its heat at T3 and rejecting all at T1. To do that in a piston engine, heat must flow in at constant temperature while the piston moves at engine speed, which is impossible. Worse, matching an Otto cycle's limits of 305 and 3,049 K needs a volume ratio of about 10,500:1, and the mean effective pressure is only 0.95 bar against the Otto cycle's 12.5 bar.
What are the four processes of the Otto cycle, and what sets its efficiency?
Isentropic compression 1-2, heat added at constant volume 2-3 (the spark-ignited charge burns almost instantly at top dead centre), isentropic expansion 3-4, and heat rejected at constant volume 4-1. The efficiency depends only on the compression ratio and γ. At r = 8 it is 56.5%, at r = 12 it is 63.0%. Petrol engines stop at about 8 to 12 because a higher r heats the unburnt charge until it autoignites: knock.
What is mean effective pressure, and why do designers care?
Mean effective pressure is the constant pressure that, acting over one full stroke, would do the cycle's net work: MEP = net work / swept volume. It measures how hard each litre of displacement works, so it compares engines of different sizes fairly. For the same power, a higher MEP means a smaller, lighter engine. The air-standard Otto cycle with r = 9.5 and 1,650 kJ/kg of heat per kg of air gives 12.5 bar; real petrol engines reach much less because of the losses covered in chapter 3.
An Otto engine's compression ratio goes from 8 to 12 (γ = 1.4). The air-standard efficiency
η = 1 − 1/r^0.4: 56.5% at r = 8 and 63.0% at r = 12. The gain shrinks as r grows, and the heat added does not enter the formula at all.
Worked examples
Otto cycle state by state · Air-standard Otto cycle, r = 9.5, start of compression 305 K and 100 kPa, heat added 1,650 kJ/kg (illustrative)
- T2 = 305 × 9.5^0.4 = 750.6 K, p2 = 100 × 9.5^1.4 = 2,338 kPa
- T3 = T2 + q/cv = 750.6 + 1,650/0.718 = 3,049 K, p3 = p2 T3/T2 = 9,496 kPa
- T4 = T3/9.5^0.4 = 1,239 K, heat rejected = 0.718 × (1,239 − 305) = 670.5 kJ/kg
- Net work = 1,650 − 670.5 = 979.5 kJ/kg, η = 59.4% (check: 1 − 1/9.5^0.4 = 59.4%)
- v1 = 0.287 × 305/100 = 0.8753 m³/kg, v2 = 0.0921 m³/kg, MEP = 979.5/(0.8753 − 0.0921) = 1,251 kPa
Answer: η = 59.4%, peak T 3,049 K, peak p 95.0 bar, MEP 12.5 bar
The same cycle in a 150 cc engine · Single cylinder, bore 57 mm, stroke 58.6 mm, r = 9.5, four-stroke at 7,000 rpm, MEP from the previous example (all illustrative)
- Vs = (π/4) × 5.7² × 5.86 = 149.5 cm³, Vc = Vs/(r − 1) = 149.5/8.5 = 17.59 cm³
- Work per cycle = MEP × Vs = 1,251 kPa × 149.5 × 10⁻⁶ m³ = 187.0 J
- Four-stroke: one cycle per two revolutions, 7,000/120 = 58.33 cycles/s
- Air-standard power = 187.0 × 58.33 = 10,909 W
Answer: About 10.9 kW air-standard; a real engine of this size makes much less, because the air-standard cycle is an upper bound
Carnot between the same limits · Carnot cycle between the Otto cycle's 305 K and its peak temperature, taking in heat over the same entropy span
- η Carnot = 1 − 305/3,049 = 90.0%, against 59.4% for Otto
- Entropy span = cv ln(T3/T2) = 0.718 × ln(3,049/750.6) = 1.0064 kJ/kg K
- Volume ratio needed = e^(Δs/R) × (T3/T1)^(1/(γ−1)) = 33.33 × 315.9 = 10,528
- Net work = (T3 − T1) Δs = 2,761 kJ/kg, swept volume 29.2 m³/kg, MEP = 94.6 kPa
Answer: η 90.0% but a 10,528:1 volume ratio and an MEP of 0.95 bar: impossible to build, useless as an engine
Diesel and dual cycles, Otto against Diesel, and the Stirling, Ericsson, Atkinson and Lenoir cycles
Which syllabus covers thisAU ME3451 Unit IVTU BME401 Module 1SPPU 202048 Unit IIMU MEC305 Module 5KTU PBMET604 Module 3
How does the Diesel cycle differ from Otto, and what is the cut-off ratio?
In a compression-ignition engine fuel is injected after compression and burns as the piston starts down, so the air-standard model adds heat at constant pressure instead of constant volume. The cut-off ratio ρ = v3/v2 says how long heat addition lasts. The efficiency is the Otto value multiplied down by a bracket that grows with ρ, so at the same compression ratio Diesel is always less efficient than Otto, and a longer cut-off (more fuel, more load) lowers it further. Air: cp 1.005, cv 0.718, R 0.287 kJ/kg K, γ 1.4 in this chapter.
What is the dual (limited-pressure) cycle?
Real diesels do neither pure case: some fuel burns almost at top dead centre (pressure jumps at nearly constant volume), the rest burns as the piston moves (roughly constant pressure). The dual cycle models this with a pressure ratio α = p3/p2 for the constant-volume part and a cut-off ratio ρ for the constant-pressure part. Set ρ = 1 and it becomes Otto; set α = 1 and it becomes Diesel. Limiting α is how designers cap the peak cylinder pressure the structure must carry.
Which is more efficient, Otto or Diesel?
It depends on what you hold equal. At the same compression ratio and heat input, Otto wins: with r = 16 the three cycles give Otto 67.0%, dual 64.5%, Diesel 60.2%. At the same peak pressure and heat input the order flips, Diesel 65.1%, dual 64.5%, Otto 59.1%, because the Diesel may use a far higher r. The second comparison is the realistic one: a diesel compresses only air, so nothing can knock and r of 14 to 23 is normal, against 8 to 12 for petrol.
How can the Stirling and Ericsson cycles reach Carnot efficiency?
Both add heat isothermally at the hot temperature and reject it isothermally at the cold one, like Carnot. Stirling joins the isotherms with two constant-volume processes, Ericsson with two constant-pressure processes. The trick is a regenerator, a matrix that stores the heat given up by the gas on one connecting process and returns it on the other. With a perfect regenerator no outside heat crosses the connecting processes, so the efficiency equals 1 − T1/T3. Real regenerators and finite heat-transfer rates keep practical Stirling engines below that.
What are the Atkinson and Lenoir cycles?
The Atkinson cycle expands the gas further than it was compressed, ideally down to atmospheric pressure, so less energy leaves with the exhaust. Modern petrol engines imitate it by holding the intake valve open longer, pushing some charge back out so the effective compression is shorter than the expansion. It gains efficiency but loses power per litre, which is why it suits hybrids, where an electric motor fills in. The Lenoir cycle has no compression at all: heat at constant volume, expansion, rejection at constant pressure; its efficiency is very low.
Otto, dual and Diesel cycles get the same heat input and are built to the same peak pressure. Which is the most efficient?
With the peak pressure fixed, the Diesel cycle reaches it by compression alone, so it can use the highest compression ratio (21.4 against 9.4 for Otto in the r = 16, α = 1.5, ρ = 1.6 case). Its efficiency is 65.1% against 64.5% for dual and 59.1% for Otto.
Worked examples
Diesel cycle · Air-standard Diesel cycle, r = 18, cut-off ratio 2.1, start of compression 310 K and 100 kPa (illustrative)
- T2 = 310 × 18^0.4 = 985.1 K, p2 = 100 × 18^1.4 = 5,720 kPa
- T3 = ρ T2 = 2.1 × 985.1 = 2,069 K, heat in = 1.005 × (2,069 − 985.1) = 1,089 kJ/kg
- T4 = T3 (ρ/r)^0.4 = 2,069 × (2.1/18)^0.4 = 876 K, heat out = 0.718 × (876 − 310) = 406.3 kJ/kg
- η = 1 − 406.3/1,089 = 62.7%; formula: 1 − (2.1^1.4 − 1)/(1.4 × 1.1 × 18^0.4) = 62.7%
- Net work 682.7 kJ/kg, v1 = 0.8897 m³/kg, MEP = 682.7/(0.8897 × 17/18) = 812 kPa
Answer: η = 62.7%, net work 683 kJ/kg, MEP 8.1 bar
Dual cycle · Air-standard dual cycle, r = 15, pressure ratio α = 1.4, cut-off ratio ρ = 1.5, start of compression 300 K and 100 kPa (illustrative)
- T2 = 300 × 15^0.4 = 886.3 K, p2 = 100 × 15^1.4 = 4,431 kPa
- Constant volume: T3 = 1.4 × 886.3 = 1,241 K, p3 = 6,204 kPa (the peak pressure)
- Constant pressure: T4 = 1.5 × 1,241 = 1,861 K; heat in = 0.718 × 354.5 + 1.005 × 620.4 = 878 kJ/kg
- Expansion: T5 = T4 (ρ/r)^0.4 = 740.9 K, heat out = 0.718 × (740.9 − 300) = 316.6 kJ/kg
- η = 1 − 316.6/878 = 63.9%; closed form gives 63.9%
Answer: η = 63.9%, peak pressure 62.0 bar, peak temperature 1,861 K
Why a diesel beats a petrol engine in practice · Same heat input 1,500 kJ/kg and start at 300 K, 100 kPa; petrol engine as Otto at r = 10 (knock-limited), diesel as Diesel at r = 18 (illustrative)
- Otto, r = 10: η = 1 − 1/10^0.4 = 60.2%; peak pressure 9,476 kPa
- Diesel, r = 18: T2 = 300 × 18^0.4 = 953.3 K, cut-off ρ = 1 + 1,500/(1.005 × 953.3) = 2.566
- T3 = 2,446 K, T4 = T3 (ρ/18)^0.4 = 1,122.0 K, η = 1 − 0.718 × (1,122.0 − 300)/1,500 = 60.7%
- Diesel peak pressure = 100 × 18^1.4 = 5,720 kPa, only about 0.60 times the Otto value
Answer: Diesel 60.7% against Otto 60.2%: the higher compression ratio more than pays for the constant-pressure heat addition
Fuel-air and actual cycles: variable specific heats and the losses of a real engine
Which syllabus covers thisAU ME3451 Unit IVVTU not in syllabusSPPU 202048 Unit IIMU MEC502 Module 5KTU PBMET604 Module 3
What does the fuel-air cycle add to the air-standard cycle?
It keeps the ideal Otto processes but uses the real working fluid: air plus fuel before combustion, combustion products after. Three effects follow. Specific heats rise with temperature, dissociation at the highest temperatures absorbs heat, and the number of moles changes on burning (for iso-octane with air the products have 5.8% more moles than the reactants). Together they lower the peak temperature and pressure and the efficiency. A richer mixture burns hotter, so its efficiency falls further.
Why do variable specific heats lower the efficiency?
Air's cp is about 1.006 kJ/kg K at 300 K but 1.241 at 1,900 K, and γ falls from 1.40 to 1.30. The same heat therefore raises the temperature less, the peak pressure is lower, and on expansion the gas gives back less work per unit of temperature drop. For r = 9 and 1,800 kJ/kg the air-standard cycle gives 58.5%; with variable cp it gives 51.6%, and the peak temperature falls from 3,229 K to 2,649 K. Isentropes now come from ∫cv dT/T = R ln(v1/v2).
What are dissociation and the change in number of moles?
At the highest flame temperatures some carbon dioxide and water vapour split back into carbon monoxide, hydrogen and oxygen. That reaction absorbs heat, so the peak temperature is lower than complete combustion would give. As the gas expands and cools, the pieces recombine and release the heat, but late in the stroke where it can do little work. Separately, burning changes the number of gas molecules; more moles at the same temperature and volume means a slightly higher pressure, a small effect compared with the other two.
How does the actual p-v diagram differ from the ideal one?
The real loop is smaller and its corners are rounded. Combustion takes time, so pressure rises over several crank degrees rather than at top dead centre: time loss. Hot gas loses heat to the cylinder walls, head and piston: heat loss, usually the largest. The exhaust valve opens before bottom dead centre and pressure falls early: blowdown loss. Pushing exhaust out and drawing charge in costs a negative pumping loop, worst at part throttle. Incomplete combustion and rubbing friction take more. In the interactive these shares are illustrative round numbers, not measurements.
What is relative efficiency?
It is the actual indicated thermal efficiency divided by the efficiency of the ideal cycle with the same compression ratio. It shows how close the engine gets to its own ideal, separating the design quality from the compression ratio. An engine with r = 9.5 that shows 36% indicated thermal efficiency (illustrative) has a relative efficiency of 60.6% against the air-standard cycle, and 68.6% against the variable-cp estimate, a fairer yardstick.
At r = 9 the air-standard Otto efficiency is 58.5%. Give the air variable specific heats and 1,800 kJ/kg of heat per kg. The efficiency becomes
With cp rising with temperature the peak temperature is only 2,649 K instead of 3,229 K and expansion returns less work: the variable-cp cycle gives 51.6%. The r-only formula holds only for constant γ.
Worked examples
Otto cycle with variable specific heats · r = 9, start at 300 K, heat added 1,800 kJ/kg; air from NASA polynomials (N2, O2, Ar) against the constant-cp air-standard cycle
- Compression: solve s°(T2) − s°(300) = R ln(9 T2/300) with R = 0.2871 kJ/kg K → T2 = 702.2 K (constant γ = 1.4: 722.5 K)
- Heat addition: u(T3) = u(T2) + 1,800 → T3 = 2,649 K; mean cv over 2-3 = 1,800/1,946.5 = 0.925 kJ/kg K (constant cv: T3 = 3,229 K)
- Expansion by the same rule to v1: T4 = 1,369 K
- Heat rejected = u(T4) − u(300) = 871.1 kJ/kg, η = 1 − 871.1/1,800 = 51.6%
- Air-standard: 1 − 1/9^0.4 = 58.5%; ratio 0.882
Answer: η 51.6% with variable cp against 58.5% air-standard; peak T 2,649 K against 3,229 K
How fast cp and γ change · Air cp from the NASA polynomials at 300, 1,100 and 1,900 K, compared with the Engineering ToolBox table (1.006, 1.159, 1.241 kJ/kg K)
- 300 K: cp = 1.0036 kJ/kg K, γ = cp/(cp − R) = 1.401
- 1,100 K: cp = 1.1591 kJ/kg K
- 1,900 K: cp = 1.2443 kJ/kg K, γ = 1.300
- Rise from 300 to 1,900 K: 24.0%; all three within 0.5% of the table
Answer: cp climbs about 24% and γ drops from 1.40 to 1.30 over the cycle's temperature range
Relative efficiency of an engine · Engine with r = 9.5 measured at 36% indicated thermal efficiency (illustrative); compare with the air-standard and variable-cp (1,800 kJ/kg) cycles
- Air-standard: η = 1 − 1/9.5^0.4 = 59.4%
- Relative efficiency = 0.36/0.5936 = 60.6%
- Variable-cp cycle at r = 9.5, 1,800 kJ/kg: η = 52.5%
- Relative to it: 0.36/0.5246 = 68.6%
Answer: 60.6% of the air-standard ideal, 68.6% of the variable-cp ideal
Gas turbine (Brayton) cycle: pressure ratio, work ratio and component efficiencies
Which syllabus covers thisAU ME3451 Units I, IIIVTU BME401 Module 2SPPU not in syllabusMU MEC305 Module 5KTU not in syllabus
What are the parts of a gas turbine, and what is the Brayton cycle?
A compressor squeezes air, a combustor burns fuel in it at nearly constant pressure, and a turbine expands the hot gas, driving the compressor and leaving surplus work. In the open cycle air comes in fresh and the exhaust leaves; in the closed cycle the same gas circulates, heated and cooled through heat exchangers. The ideal Brayton cycle is isentropic compression, constant-pressure heat addition, isentropic expansion and constant-pressure heat rejection. Aircraft engines aim at maximum work per kilogram of air to stay small; power-station machines aim at efficiency. Air: cp 1.005 kJ/kg K, γ 1.4.
What sets the ideal Brayton efficiency?
Only the pressure ratio rp. Compression raises the temperature by the factor rp^((γ−1)/γ), expansion drops it by the same factor, and the efficiency is 1 − 1/rp^0.286. At rp = 12 it is 50.8%. A higher turbine inlet temperature does not change the ideal efficiency, but it raises the work per kilogram. Typical pressure ratios are about 5 to 20.
Is there a best pressure ratio for net work?
Yes. At rp = 1 nothing is compressed so there is no work; at a very high rp the compressor outlet approaches the turbine inlet temperature and no heat can be added. In between, the ideal net work peaks at rp = (T3/T1)^(γ/(2(γ−1))), where the compressor outlet and turbine exit temperatures are equal. For 305 K and 1,450 K that is rp = 15.3, giving 427 kJ/kg. With real component efficiencies the peak moves to a lower pressure ratio.
What is the back work ratio, and why does component efficiency matter so much?
The back work ratio is compressor work divided by turbine work. Compressing a gas takes a lot of work because its specific volume is large: typically 40 to 80% of the turbine output goes back into the compressor, against 1 to 3% for the pump of a steam plant. Net work is a small difference of two large numbers, so a few points of compressor or turbine efficiency move it a lot. At rp = 12, T3 = 1,400 K and ηt = 0.90, dropping ηc from 0.90 to 0.80 cuts net work by 15%. The real cycle also gets a best pressure ratio for efficiency.
What limits the turbine inlet temperature?
The first-stage turbine blades sit in the hottest gas while spinning under huge centrifugal load, so their material sets the limit. Modern engines burn at around 1,500 K, hotter than the blade alloy could survive alone. Designers bleed compressor air through passages inside the blades to cool them and coat the surface with a ceramic thermal barrier, which can cut blade temperature by up to about 200 °C. Every gain in inlet temperature raises work per kilogram and, in a real cycle, efficiency too.
A gas turbine runs at rp = 12, T3 = 1,400 K, ηt = 0.90. Its compressor efficiency falls from 0.90 to 0.80. The net work falls by about
Net work = turbine work − compressor work, and the compressor takes more than half of the turbine output here. The compressor work rises by an eighth, which eats into the net work: 297 → 254 kJ/kg, a 15% fall.
Worked examples
Ideal Brayton cycle · Ideal air-standard Brayton cycle, compressor inlet 305 K, pressure ratio 12, turbine inlet 1,450 K (illustrative)
- rp^((γ−1)/γ) = 12^0.2857 = 2.0339
- T2 = 305 × 2.0339 = 620.4 K, T4 = 1,450/2.0339 = 712.9 K
- Compressor work = 1.005 × (620.4 − 305) = 316.9 kJ/kg, turbine work = 1.005 × (1,450 − 712.9) = 740.8 kJ/kg
- Net work = 423.9 kJ/kg, heat in = 1.005 × (1,450 − 620.4) = 833.8 kJ/kg
- η = 423.9/833.8 = 50.8% (= 1 − 1/2.0339), back work ratio = 316.9/740.8 = 42.8%
Answer: η 50.8%, net work 424 kJ/kg, back work ratio 42.8%
The same cycle with real compressor and turbine · As above, with compressor isentropic efficiency 0.86 and turbine 0.89
- T2 = 305 + (620.4 − 305)/0.86 = 671.7 K
- T4 = 1,450 − 0.89 × (1,450 − 712.9) = 794.0 K
- Compressor work = 368.5, turbine work = 659.3, net work = 290.8 kJ/kg
- Heat in = 1.005 × (1,450 − 671.7) = 782.2 kJ/kg, η = 37.2%
- Back work ratio = 55.9%; net work down 31% from the ideal
Answer: η 37.2% (ideal 50.8%), net work 291 kJ/kg, back work ratio 55.9%
Pressure ratio for maximum work · Compressor inlet 305 K, turbine inlet 1,450 K; ideal components, then ηc 0.86 and ηt 0.89
- Ideal: rp,opt = (1,450/305)^(1.4/0.8) = 15.31
- There T2 = T4 = √(305 × 1,450) = 665.0 K and net work = cp(√T3 − √T1)² = 427.1 kJ/kg at η = 54.1%
- Real: rp,opt = (0.86 × 0.89 × 1,450/305)^(1.75) = 9.59, net work 293.6 kJ/kg
- A grid search over rp from 1 to 61 finds the same optima (15.31 and 9.59)
Answer: Ideal: rp 15.3, 427 kJ/kg; real: rp 9.6, 294 kJ/kg
Regeneration, intercooling and reheat in gas turbine cycles
Which syllabus covers thisAU ME3451 Unit IIIVTU BME401 Module 2SPPU not in syllabusMU not in syllabusKTU not in syllabus
What does a regenerator do, and when does it stop helping?
A regenerator is a heat exchanger that uses the hot turbine exhaust to preheat the compressed air before the combustor, so less fuel is needed for the same turbine inlet temperature. The net work does not change; only the heat input falls. Its effectiveness ε is the fraction of the possible temperature rise achieved, T2 + ε(T4 − T2). It only helps while the exhaust is hotter than the compressor outlet. In an ideal cycle with T1 300 K and T3 1,200 K that holds below a pressure ratio of 11.31; above it the exhaust would heat nothing and the regenerator would cool the air instead. Air-standard values here: cp 1.005 kJ/kg K, γ 1.4.
Why intercool the compressor, and why can efficiency fall?
Compressing in two stages with a cooler between them back to the inlet temperature cuts compressor work, because cooler air is easier to compress. The work is least when both stages share the pressure ratio equally, at an intermediate pressure √(p1 p2). The catch: the air now leaves the compressor colder, so the combustor must add more heat. In an ideal cycle at rp 9 and T3 1,300 K, intercooling plus reheat raise net work from 346 to 482 kJ/kg but drop efficiency from 46.6% to 38.7%. The extra heat is only recovered when a regenerator is added.
What does reheat between turbine stages do?
Reheat splits the expansion: after the high-pressure turbine the gas is heated again, usually close to the original turbine inlet temperature, and then expanded in a second turbine. Because the constant-pressure lines spread apart at higher temperature, expanding from a hotter state gives more work per unit pressure drop. Net work rises, and so does the exhaust temperature. Alone, reheat lowers efficiency for the same reason as intercooling. With a regenerator, that hot exhaust is exactly what preheats the compressed air, so intercooling, reheat and regeneration are used together.
What is the Ericsson limit, and where does the combined cycle fit?
With many stages of intercooling and reheat, compression approaches an isotherm at T1 and expansion an isotherm at T3. Add a perfect regenerator and every bit of external heat enters at T3 and leaves at T1: the Ericsson cycle, with Carnot efficiency. For rp 10, T1 300 K and T3 1,200 K the ideal efficiency climbs from 51.7% with one stage to 65.3% with two and 74.7% with fifty, against Carnot's 75%. Power stations take another route: the hot exhaust raises steam in a heat recovery steam generator (HRSG) for a Rankine cycle. Most large combined cycle units peak at 55-59% on the lower heating value.
An ideal gas turbine runs at pressure ratio 20 with T1 300 K and T3 1,200 K. Adding a regenerator of effectiveness 0.8 will
At rp 20 the turbine exit is only 510 K while the compressor delivers air at 706 K, so the exhaust is colder than the air it is meant to heat. The regenerator would cool the compressed air to 549 K and the combustor must make up the difference: efficiency falls from 57.5% to 43.6%. The ideal crossover for these temperatures is rp 11.31.
Worked examples
Adding a regenerator to a small gas turbine · Compressor inlet 305 K (32 °C), pressure ratio 6, turbine inlet 1,250 K, compressor and turbine isentropic efficiencies 0.85 and 0.88 (typical), regenerator effectiveness 0.75 (illustrative); air cp 1.005 kJ/kg K, γ 1.4
- rp^((γ−1)/γ) = 6^0.2857 = 1.6685; T2s = 305 × 1.6685 = 508.9 K, T2 = 305 + (508.9 − 305)/0.85 = 544.9 K
- T4s = 1,250/1.6685 = 749.2 K, T4 = 1,250 − 0.88 × (1,250 − 749.2) = 809.3 K
- wc = 1.005 × (544.9 − 305) = 241.1 kJ/kg, wt = 1.005 × (1,250 − 809.3) = 442.9 kJ/kg, w_net = 201.9 kJ/kg
- No regenerator: q_in = 1.005 × (1,250 − 544.9) = 708.6 kJ/kg, η = 201.9/708.6 = 28.5%
- Exhaust 809.3 K > compressor exit 544.9 K, so a regenerator helps: Tx = 544.9 + 0.75 × (809.3 − 544.9) = 743.2 K
- q_in = 1.005 × (1,250 − 743.2) = 509.4 kJ/kg, η = 201.9/509.4 = 39.6%; the exhaust leaves the regenerator at 611.0 K
Answer: η rises from 28.5% to 39.6% with the same net work of 201.9 kJ/kg
Intercooling and reheat, with and without a regenerator · Ideal machines, T1 300 K, pressure ratio 9, turbine inlet 1,300 K; two-stage compression with perfect intercooling and two-stage expansion with reheat to 1,300 K, both split at √9 = 3
- Simple cycle: 9^0.2857 = 1.8734, T2 = 562.0 K, T4 = 693.9 K; w_net = 609.1 − 263.3 = 345.8 kJ/kg, η = 1 − 1/1.8734 = 46.6%
- Per stage 3^0.2857 = 1.3687: each compressor stage ends at 410.6 K, each turbine stage at 949.8 K
- wc = 2 × 1.005 × (410.6 − 300) = 222.3 kJ/kg, wt = 2 × 1.005 × (1,300 − 949.8) = 703.9 kJ/kg, w_net = 481.6 kJ/kg
- No regenerator: q_in = 1.005 × (1,300 − 410.6) + 1.005 × (1,300 − 949.8) = 1,245.8 kJ/kg, η = 38.7%
- Perfect regenerator: air preheated to 949.8 K, q_in = 2 × 1.005 × (1,300 − 949.8) = 703.9 kJ/kg, η = 68.4%
- Check: 1 − (300/1,300) × 1.3687 = 68.4%
Answer: Net work 345.8 → 481.6 kJ/kg; η 46.6% → 38.7% without and 68.4% with the regenerator
At what pressure ratio does a regenerator stop helping? · T1 300 K, turbine inlet 1,200 K; first ideal machines, then compressor and turbine efficiencies 0.85 and 0.88 (typical)
- Ideal: T4 = T2 means 1,200/x = 300 x with x = rp^0.2857, so x = √(1,200/300) = 2 and rp = 2^3.5 = 11.31
- This is also the pressure ratio of maximum net work for the ideal simple cycle
- Real: 300(1 + (x − 1)/0.85) = 1,200(1 − 0.88(1 − 1/x)) gives 352.94 x² − 196.94 x − 1056 = 0
- x = 2.0311, rp = x^3.5 = 11.94; both temperatures are then 663.9 K
Answer: Regeneration pays below rp 11.31 (ideal) and below rp 11.94 with real machines
Jet propulsion: turbojet, turboprop, turbofan, ramjet, pulse jet and rocket
Which syllabus covers thisAU not in syllabusVTU BME401 Module 2SPPU not in syllabusMU not in syllabusKTU not in syllabus
Where does thrust come from, and what is propulsive efficiency?
A jet engine takes in air at the flight speed Va and throws it out at a higher jet speed Vj. The momentum change per second is the thrust, plus a pressure term if the nozzle exit pressure differs from ambient. Thrust power is F × Va; the engine also leaves kinetic energy in the wake. Propulsive efficiency is thrust power divided by the rise in kinetic energy, which works out to 2/(1 + Vj/Va). It is 100% only when Vj = Va, when the thrust is zero. For Va 250 m/s and Vj 600 m/s it is 58.8%.
How does an ideal turbojet work, and how are its efficiencies defined?
Air is slowed in the intake, which raises its pressure and temperature (ram rise), then compressed, burned at constant pressure, expanded through a turbine that produces exactly the compressor's work, and finally expanded in the nozzle to ambient pressure. Thermal efficiency is the kinetic energy gained divided by the fuel energy; overall efficiency is thrust power divided by fuel energy, the product of thermal and propulsive. Thrust-specific fuel consumption (TSFC) is fuel flow per unit thrust. At 11 km and Mach 0.85 an ideal turbojet with pressure ratio 12 and 1,400 K turbine inlet gives an overall efficiency of 22.1%.
Why do airliners use turbofans, and where do turboprops fit?
Thrust is mass flow times velocity change, but the wasted kinetic energy grows with the square of the jet speed. So it is better to push a lot of air gently. A turbofan drives a large fan with its turbine; most of the fan air bypasses the core. The bypass ratio is bypass flow over core flow, and ratios above 5:1 are now common on airliners. Slower exhaust means higher propulsive efficiency and much less jet noise at subsonic speeds. A turboprop takes this further with a propeller geared to the turbine shaft: very efficient at moderate speeds, but limited at high speed as the propeller tips approach the speed of sound.
How do the ramjet and the pulse jet work without a compressor?
A ramjet is a shaped duct: at high flight speed the intake slows the air so much that the ram pressure rise replaces a compressor, so there is no turbine either. It gives no thrust at rest and little below about Mach 0.5, works best around Mach 3 and can run to about Mach 6, which is why it suits missiles that are first boosted by a rocket. A pulse jet burns fuel in pulses: spring flap valves at the inlet open when the chamber pressure drops and close when the next charge ignites. It can produce static thrust but is noisy and inefficient.
What makes a rocket different, and what is specific impulse?
A rocket carries its oxidiser as well as its fuel, so it needs no air: it works in space, and its thrust ṁVe + (pe − pa)Ae does not depend on flight speed because there is no incoming air momentum to subtract. Specific impulse is thrust per unit weight flow of propellant, F/(ṁ g0), in seconds; for a matched nozzle it is Ve/g0. An illustrative effective exhaust velocity of 3,000 m/s gives 306 s. A ram rocket (ducted rocket) burns fuel-rich rocket exhaust with air rammed in from outside, combining the two ideas.
An engine flying at 250 m/s makes 17.5 kN by accelerating 50 kg/s of air to 600 m/s. A fan makes the same thrust with 175 kg/s accelerated to only 350 m/s. Its propulsive efficiency is
Propulsive efficiency is 2/(1 + Vj/Va). With Vj/Va = 2.4 it is 58.8%; with Vj/Va = 1.4 it is 83.3%. Both produce 17.5 kN, but the slower jet wastes far less kinetic energy in the wake: 3,062 kW against 875 kW. That is the case for the high-bypass turbofan.
Worked examples
Thrust and propulsive efficiency of a jet · Air flow 50 kg/s, flight speed 250 m/s, jet velocity 600 m/s, nozzle exit at ambient pressure (illustrative; fuel mass neglected)
- F = ṁ (Vj − Va) = 50 × (600 − 250) = 17,500 N = 17.5 kN
- Thrust power = F Va = 17,500 × 250 = 4.375 MW
- Kinetic energy added = ṁ (Vj² − Va²)/2 = 50 × (600² − 250²)/2 = 7.4375 MW
- ηp = 4.375/7.4375 = 58.8%; check 2/(1 + 600/250) = 58.8%
Answer: Thrust 17.5 kN, propulsive efficiency 58.8%
Ideal turbojet cruising at 11 km · ISA at 11 km: 216.65 K, 22.632 kPa; Mach 0.85, compressor pressure ratio 12, turbine inlet 1,400 K, Jet A-1 Q_R 43,150 kJ/kg; cp 1.005 kJ/kg K, γ 1.4, R 287.1 J/kg K; all processes ideal, nozzle fully expanded, fuel mass neglected in the flow
- a0 = √(1.4 × 287.1 × 216.65) = 295.1 m/s, Va = 0.85 × 295.1 = 250.8 m/s
- Ram: T2 = 216.65 × (1 + 0.2 × 0.85²) = 247.96 K, p2 = 22.632 × (247.96/216.65)^3.5 = 36.30 kPa
- Compressor: T3 = 247.96 × 12^0.2857 = 504.3 K, p3 = 435.6 kPa, wc = 1.005 × (504.3 − 247.96) = 257.7 kJ/kg
- Turbine drives the compressor: T5 = 1,400 − (504.3 − 247.96) = 1,143.6 K, p5 = 435.6 × (1,143.6/1,400)^3.5 = 214.6 kPa
- Nozzle to 22.632 kPa: T9 = 1,143.6 × (22.632/214.6)^0.2857 = 601.4 K, Vj = √(2 × 1,005 × (1,143.6 − 601.4)) = 1,044 m/s
- Specific thrust = 1,044 − 251 = 793 N per kg/s; f = 1.005 × (1,400 − 504.3)/43,150 = 0.02086
- TSFC = 0.02086/793 = 26.3 g/(kN·s); ηp = 38.7%, ηth = 57.0%, ηo = 22.1%
Answer: 793 N per kg/s of air, TSFC 26.3 g/(kN·s), overall efficiency 22.1%
A ramjet at Mach 2.5 and at Mach 0.5 · ISA 11 km (216.65 K, 22.632 kPa), burner exit 1,800 K, ideal duct, nozzle fully expanded, same air properties and fuel as above
- Mach 2.5: Va = 738 m/s, ram T2 = 216.65 × (1 + 0.2 × 2.5²) = 487.5 K, pressure ratio p2/p0 = 17.09 with no compressor
- Nozzle back to 22.632 kPa: T9 = 1,800 × 216.65/487.5 = 800.0 K, Vj = 1,418 m/s
- Specific thrust = 1,418 − 738 = 680 N per kg/s, ηth = 1 − T0/T2 = 55.6%, ηp = 68.5%
- Mach 0.5: Va = 148 m/s, ram ratio only 1.186, Vj = 415 m/s, specific thrust 268 N per kg/s, ηth 4.8%
Answer: 680 N per kg/s at Mach 2.5 against 268 at Mach 0.5; thermal efficiency 55.6% against 4.8%
Steam properties, the Mollier chart and boilers
Which syllabus covers thisAU ME3451 Unit IVTU BME401 Module 3SPPU not in syllabusMU MEC305 Module 4KTU PBMET604 Module 1
What happens when water is turned into steam at constant pressure?
Three stages. Sensible heat warms the water to the saturation temperature, which is fixed by the pressure: 179.9 °C at 10 bar, 99.6 °C at 1 bar. Latent heat then boils it at that constant temperature until it is dry saturated steam. Further heating superheats the vapour above saturation; the excess is the degree of superheat. Taking 1 kg from water at 25 °C to steam at 250 °C, all at 10 bar, needs about 657 kJ sensible, 2,014 kJ latent and 166 kJ of superheat (IAPWS-IF97). The latent part dominates, and it shrinks as pressure rises.
What is wet steam and its dryness fraction?
Between saturated liquid and dry saturated vapour the steam is a mixture of droplets and vapour at the saturation temperature. The dryness fraction x is the mass of vapour per kg of mixture: 0 for saturated water, 1 for dry steam. Any property is the liquid value plus x times the change on evaporation. At 10 bar, hf is 762.7 kJ/kg and hfg 2,014.4 kJ/kg, so steam with x = 0.9 carries 2,575.7 kJ/kg. Specific volume follows the same rule, and since vg is about 172 times vf at 10 bar, v ≈ x vg is often good enough.
How do the T-s and Mollier (h-s) charts help, and where is the critical point?
On the T-s chart the saturated liquid and vapour lines form a dome; states inside are wet, to the right superheated, to the left compressed liquid. Constant-pressure lines run horizontally through the dome, because boiling happens at constant temperature, and climb steeply outside it. The dome closes at the critical point, 220.64 bar and 373.946 °C (IAPWS), where liquid and vapour become indistinguishable and the latent heat is zero. The Mollier chart plots h against s, so turbine and nozzle work, an enthalpy drop, can be read off as a vertical distance, and an ideal expansion is a vertical line.
How is the dryness of steam in a pipe measured?
With a throttling calorimeter, a sample is throttled through a small valve to near-atmospheric pressure. Throttling keeps enthalpy constant, and if the sample ends up superheated its enthalpy is fixed by the measured pressure and temperature, so x before the valve follows from h = hf + x hfg. It needs fairly dry steam: from a 12 bar main, keeping about 5 K of superheat at 1 bar requires x above roughly 0.95. For wetter steam a separating calorimeter first removes droplets mechanically; their mass and the condensed vapour give the dryness, and the two instruments are often used in series.
What separates fire-tube from water-tube boilers?
In a fire-tube boiler, such as the vertical Cochran, hot gases flow through tubes surrounded by a large shell of water. It is compact, holds a big reserve of water and suits small factories, but the large shell limits pressure: fire-tube boilers are rarely used above about 24 bar. In a water-tube boiler, such as the Babcock and Wilcox, water flows inside tubes heated by the furnace gases outside. Thin tubes take high pressure and respond quickly, so power station boilers are water-tube, producing up to about 500 kg/s of steam at around 160 bar and 550 °C.
What are boiler mountings and accessories, and how are boilers rated?
Mountings are fittings needed for safe operation: safety valves, water-level indicator, pressure gauge, steam stop valve, feed check valve, blow-off cock and fusible plug, a plug that melts and lets steam douse the fire if the water level falls too low. Accessories raise efficiency: economiser (heats feed water with flue gas), superheater, air preheater and feed pump. Boiler efficiency is the heat taken up by the steam divided by the fuel energy. Equivalent evaporation converts the output to the water that could be evaporated from and at 100 °C, using 2,257 kJ/kg, so boilers with different steam conditions can be compared.
Steam at 10 bar with dryness 0.97 is throttled to 1 bar. After the valve it is
Throttling keeps enthalpy constant. At 10 bar, h = 762.7 + 0.97 × 2,014.4 = 2,716.7 kJ/kg, more than the 2,674.9 kJ/kg of dry saturated steam at 1 bar. So the steam emerges superheated, at about 120 °C, 20 K above saturation. This is exactly why the throttling calorimeter works for fairly dry steam.
Worked examples
Properties of wet steam at 10 bar · Steam at 10 bar with dryness fraction 0.9; saturation properties from IAPWS-IF97
- At 10 bar: Tsat = 179.89 °C, hf = 762.68, hg = 2,777.12 kJ/kg, so hfg = 2,014.44 kJ/kg
- h = 762.68 + 0.9 × 2,014.44 = 2,575.7 kJ/kg
- sf = 2.1384, sfg = 4.4465 kJ/kg K: s = 2.1384 + 0.9 × 4.4465 = 6.1403 kJ/kg K
- vf = 0.001127, vg = 0.19435 m³/kg: v = 0.001127 + 0.9 × (0.19435 − 0.001127) = 0.1750 m³/kg (x vg = 0.1749)
Answer: T 179.89 °C, h 2,575.7 kJ/kg, s 6.1403 kJ/kg K, v 0.1750 m³/kg
Dryness from a throttling calorimeter · A sample from a 12 bar steam main is throttled to 1 bar, where a thermometer reads 115 °C (illustrative readings)
- At 1 bar Tsat = 99.61 °C, so 115 °C is 15.4 K superheated: h2 = 2,706.5 kJ/kg (IF97 Region 2)
- Throttling: h1 = h2 = 2,706.5 kJ/kg
- At 12 bar: hf = 798.5, hfg = 1,985.3 kJ/kg
- x = (2,706.5 − 798.5)/1,985.3 = 0.9611
Answer: Dryness fraction of the steam in the main: 0.961
Boiler efficiency and equivalent evaporation · A boiler makes 5,000 kg/h of steam at 12 bar and 250 °C from feed water at 40 °C, burning 620 kg/h of coal with a calorific value of 26,000 kJ/kg (illustrative)
- Steam: 12 bar, 250 °C is 62.0 K above Tsat 188.0 °C, h = 2,935.7 kJ/kg
- Feed water at 40 °C and 12 bar (compressed liquid): h_fw = 168.6 kJ/kg, against hf 167.5 kJ/kg at 40 °C: the pressure adds 1.1 kJ/kg
- Heat to steam = 5,000 × (2,935.7 − 168.6) = 1,38,35,435 kJ/h; fuel energy = 620 × 26,000 = 1,61,20,000 kJ/h
- η_boiler = 1,38,35,435/1,61,20,000 = 85.8%
- Evaporation = 5,000/620 = 8.06 kg steam per kg coal; equivalent = 8.06 × (2,935.7 − 168.6)/2,257 = 9.89 kg/kg
Answer: Boiler efficiency 85.8%, equivalent evaporation 9.89 kg of steam per kg of coal from and at 100 °C
Rankine cycle: Carnot against Rankine and the effect of boiler pressure, superheat and condenser pressure
Which syllabus covers thisAU ME3451 Unit IVTU BME401 Module 3SPPU not in syllabusMU MEC305 Module 4KTU PBMET604 Module 1
What are the four processes of the Rankine cycle?
Numbering from the condenser exit: 1→2, a pump raises saturated water to boiler pressure; 2→3, the boiler heats, boils and superheats it at constant pressure; 3→4, steam expands in the turbine; 4→1, the condenser turns the exhaust back into water at constant pressure. Efficiency is (turbine work − pump work)/heat added. Because water is nearly incompressible, the pump work is tiny: for 60 bar, 450 °C and 0.1 bar it is 6.0 kJ/kg against 1,174.1 kJ/kg from the turbine, a back work ratio of 0.5%, against a typical 40-80% in a gas turbine.
Why not run a steam plant on the Carnot cycle?
A Carnot vapour cycle inside the dome would add and reject heat at constant temperature, so on paper it is the most efficient. In practice its compressor would have to squeeze a wet mixture, with x = 0.32 for a 60 bar boiler and 0.1 bar condenser, back to saturated liquid: droplets erode blades and the machine would be huge. Its work ratio is low (71% against 99.5% for the Rankine cycle), so small machine losses eat the output, and its turbine expands wet steam. Superheating cannot be done at constant temperature, so the Carnot cycle caps the steam temperature at saturation. Rankine condenses completely and pumps liquid instead.
What do boiler pressure, superheat and condenser pressure do?
Raising boiler pressure at a fixed 500 °C lifts the efficiency (ideal, 0.1 bar condenser) from 36.8% at 40 bar to 40.8% at 120 bar, but the turbine exit gets wetter: x falls from 0.859 to 0.779. More superheat helps both: at 60 bar, going from 400 to 550 °C raises η from 36.9% to 39.1% and x from 0.786 to 0.851. Lowering condenser pressure from 0.2 to 0.05 bar raises η from 35.6% to 39.5%, limited by the cooling water temperature and by air leaking into the vacuum. Designers keep exit dryness above about 0.88 (typical) to protect the last blades.
What is the mean temperature of heat addition?
Heat enters the Rankine cycle over a range of temperatures, from cold feed water to superheated steam. The mean temperature of heat addition Tm is the constant temperature that would add the same heat with the same entropy change: Tm = (h3 − h2)/(s3 − s2). The ideal cycle then behaves like a Carnot engine between Tm and the condenser temperature, η = 1 − T_cond/Tm. For 60 bar, 450 °C and 0.1 bar, Tm is 511.3 K and 1 − 318.96/511.3 = 37.6%. Every improvement, higher pressure, superheat, reheat or feed heating, works by raising Tm.
How do turbine and pump losses change the cycle?
Friction makes real expansion and compression irreversible. The turbine isentropic efficiency is actual over ideal enthalpy drop, and the pump efficiency is ideal over actual work. With a turbine at 0.85 and a pump at 0.80 (typical), the 60 bar, 450 °C, 0.1 bar cycle drops from 37.6% to 31.9%, and the specific steam consumption, 3,600/w_net, rises from 3.08 to 3.63 kg/kWh. The turbine loss reheats the steam, so the exit becomes drier, x 0.810 to 0.883: a small consolation. Real plants also lose pressure in pipes and heat to the surroundings.
A Rankine cycle keeps 500 °C at the turbine inlet and 0.1 bar in the condenser, and the boiler pressure is raised from 40 to 120 bar. The turbine exit dryness
At the same temperature, higher-pressure steam has lower entropy, so the vertical expansion line on the T-s chart lands further inside the dome: x falls from 0.859 to 0.779, while η rises from 36.8% to 40.8%. That wet exhaust is why high-pressure plants add superheat and reheat.
Worked examples
Ideal Rankine cycle at 60 bar and 450 °C · Boiler 60 bar, turbine inlet 450 °C, condenser 0.1 bar, ideal pump and turbine; steam properties IAPWS-IF97
- State 1, saturated water at 0.1 bar: T = 45.81 °C, h1 = 191.81 kJ/kg, v1 = 0.001010 m³/kg
- Pump: w_p = 6.04 kJ/kg (v1 Δp = 0.001010 × 5,990 = 6.05), h2 = 197.86 kJ/kg
- State 3, 60 bar and 450 °C: h3 = 3,302.8 kJ/kg, s3 = 6.7216 kJ/kg K
- State 4 at 0.1 bar with s4 = s3: x4 = (6.7216 − 0.6492)/7.4997 = 0.8097, h4 = 191.81 + 0.8097 × 2,392.1 = 2,128.7 kJ/kg
- w_t = 3,302.8 − 2,128.7 = 1,174.1 kJ/kg, w_net = 1,168.1 kJ/kg, q_in = 3,302.8 − 197.9 = 3,104.9 kJ/kg
- η = 1,168.1/3,104.9 = 37.62%, SSC = 3,600/1,168.1 = 3.082 kg/kWh
- Check: Tm = 3,104.9/(6.7216 − 0.6492) = 511.3 K, 1 − 318.96/511.3 = 37.62%
Answer: η 37.6%, w_net 1,168.1 kJ/kg, SSC 3.08 kg/kWh, exit dryness 0.810 (too wet for a real turbine)
The same cycle with real turbine and pump · As above, turbine isentropic efficiency 0.85, pump efficiency 0.80 (typical)
- Pump: w_p = 6.04/0.80 = 7.55 kJ/kg, h2 = 199.37 kJ/kg
- Turbine: h4 = 3,302.8 − 0.85 × (3,302.8 − 2,128.7) = 2,304.8 kJ/kg, so w_t = 998.0 kJ/kg
- x4 = (2,304.8 − 191.81)/2,392.1 = 0.8833
- w_net = 998.0 − 7.55 = 990.4 kJ/kg, q_in = 3,103.4 kJ/kg, η = 31.91%
- SSC = 3,600/990.4 = 3.635 kg/kWh
Answer: η falls from 37.6% to 31.9%, SSC rises to 3.63 kg/kWh, exit dryness improves to 0.883
Raising the boiler pressure from 40 to 120 bar · Turbine inlet 500 °C, condenser 0.1 bar, ideal cycle
- 40 bar: h3 = 3,445.8 kJ/kg, s3 = 7.0919; x4 = 0.8591; w_net = 1,195.1, q_in = 3,250.0 kJ/kg; η = 36.77%
- 120 bar: h3 = 3,350.0 kJ/kg, s3 = 6.4902; x4 = 0.7788; w_net = 1,283.1, q_in = 3,146.1 kJ/kg; η = 40.78%
- Mean temperature of heat addition: 504.4 K → 538.6 K, pump work 4.0 → 12.1 kJ/kg
- SSC 3.012 → 2.806 kg/kWh
Answer: η 36.8% → 40.8%, but exit dryness 0.859 → 0.779, below the typical 0.88 limit
Reheat and regenerative Rankine cycles with open and closed feedwater heaters
Which syllabus covers thisAU ME3451 Unit IVTU BME401 Module 3SPPU not in syllabusMU MEC305 Module 4KTU PBMET604 Module 1
Why send the steam back to the boiler halfway through the turbine?
Raising boiler pressure lifts efficiency but leaves the turbine exhaust too wet, and water droplets erode the last blades. Reheat expands the steam in a high-pressure turbine, reheats it at a lower pressure and finishes the expansion in a low-pressure turbine. For an ideal cycle at 120 bar and 520 °C with a 0.1 bar condenser, reheating at 25 bar raises the exit dryness from 0.788 to 0.898, the work per kg by 22% and the efficiency by only 1.6 points. Dryness and work are the real reasons; the efficiency gain is a bonus. All steam properties in this chapter are IAPWS-IF97.
How does an open feedwater heater work, and how much steam is bled?
Some steam is bled from the turbine and mixed directly with the condensate in a vessel at the bleed pressure, so the water leaves as saturated liquid at that pressure. Because it mixes, every open heater needs its own pump after it; the same vessel also releases dissolved gases, which is why the open heater is the deaerator. The bleed fraction y comes from the heater's energy balance. Feedwater now enters the boiler hot, so less heat is added at low temperature: for 80 bar, 480 °C with a 5 bar bleed, y = 0.180 and efficiency rises 2.7 points even though each kg of steam does less work.
What is different in a closed feedwater heater?
A closed heater is a shell-and-tube exchanger: feedwater flows in the tubes at boiler pressure, bled steam condenses on the shell side, and the two never mix, so no extra pump is needed. The condensed bleed, the drain, is either pumped forward into the feedwater line or cascaded backward through a trap to a lower-pressure heater or the condenser. The feedwater cannot quite reach the bleed saturation temperature; the shortfall is the terminal temperature difference. In this book's model the drain is throttled to the condenser, and for 140 bar, 540 °C bled at 4 bar the closed heater gives 44.15% against 44.82% for an open heater at the same bleed.
At what pressure should you reheat or bleed?
Sweep it and look. For one open heater the best bleed puts the heater's saturation temperature roughly midway between boiler and condenser saturation: at 80 bar the best is about 8.0 bar (170 °C against a midway 170 °C). For ideal reheat back to the boiler temperature the best reheat pressure ranges from about 14% to 47% of boiler pressure over 60 to 160 bar and 400 to 600 °C; a figure near a quarter is often quoted (typical). Real plants use several heaters, five to eight being common (typical): the Gavin coal plant has seven closed heaters and one open deaerator.
One open feedwater heater is added to an ideal Rankine cycle. Per kg of steam leaving the boiler, the turbine work and the cycle efficiency will
The bled steam leaves the turbine early, so each kg does less work (1137 against 1240 kJ/kg at 80 bar, 480 °C, bleed 5 bar). But the boiler now starts from 152 °C feedwater, so the heat added falls even more and efficiency rises from 39.1% to 41.8%.
Worked examples
Reheat at 25 bar in a 120 bar cycle · Ideal cycle (isentropic turbine and pump), boiler 120 bar and 520 °C, reheat at 25 bar back to 520 °C, condenser 0.1 bar (illustrative); IAPWS-IF97 properties
- Pump: h1 = hf at 0.1 bar = 191.8 kJ/kg, h2 = 203.9 kJ/kg (wp = 12.08 kJ/kg)
- HP turbine: h3 = 3,403.4 kJ/kg, s3 = 6.5584 kJ/kg K; at 25 bar h4 = 2,960.3 kJ/kg (280.1 °C, still superheated)
- Reheat: h5 = 3,507.2 kJ/kg, s5 = 7.3821; LP turbine to 0.1 bar: x6 = 0.898, h6 = 2,339.3 kJ/kg
- wt = (3,403.4 − 2,960.3) + (3,507.2 − 2,339.3) = 1,610.9 kJ/kg; qin = 3,746.3 kJ/kg
- η = (1,610.9 − 12.08)/3,746.3 = 42.68%; without reheat η = 41.09% and x = 0.788
- Specific steam consumption 3600/wnet: 2.252 kg/kWh with reheat, 2.738 without
Answer: η = 42.68% (+1.59 points), exit dryness 0.788 → 0.898, steam rate 2.74 → 2.25 kg/kWh
One open feedwater heater · Ideal cycle, boiler 80 bar and 480 °C, condenser 0.1 bar, steam bled at 5 bar to an open heater (illustrative)
- h1 = 191.8 kJ/kg; pump 1 to 5 bar: h2 = 192.3 kJ/kg; heater exit saturated liquid h3 = 640.2 kJ/kg (151.8 °C); pump 2: h4 = 648.4 kJ/kg
- Turbine: h5 = 3,349.5; bleed at 5 bar h6 = 2,680.3 kJ/kg (x6 = 0.968); exit h7 = 2,109.3 kJ/kg (x7 = 0.802)
- Heater balance y h6 + (1 − y) h2 = h3: y = (640.2 − 192.3)/(2,680.3 − 192.3) = 0.1800
- wt = (3,349.5 − 2,680.3) + 0.8200 × (2,680.3 − 2,109.3) = 1,137.4 kJ/kg; wp = 8.58 kJ/kg
- qin = 3,349.5 − 648.4 = 2,701.2 kJ/kg, η = 1,128.8/2,701.2 = 41.79%
- Simple cycle for comparison: η = 39.12%; searching the bleed pressure gives a best of 8.0 bar (η 41.84%)
Answer: y = 0.180, η = 41.79% against 39.12% (+2.67 points)
One closed heater with its drain trapped to the condenser · Ideal cycle, boiler 140 bar and 540 °C, condenser 0.1 bar, bleed 4 bar to a closed heater; feedwater leaves at the bleed saturation temperature (TTD 0), drain throttled to the condenser (illustrative)
- Pump the condensate straight to 140 bar: h2 = 205.9 kJ/kg; feedwater leaves the heater at 143.6 °C and 140 bar: h3 = 613.5 kJ/kg
- Turbine: h4 = 3,434.2; bleed at 4 bar h5 = 2,586.6 kJ/kg (x5 = 0.929); drain hf = 604.7 kJ/kg
- Heater balance y (h5 − h7) = h3 − h2: y = 407.6/1,981.9 = 0.2057
- Drain throttled to 0.1 bar arrives with x = 0.173; its heat goes to the condenser: qout = 1,575.4 kJ/kg
- wnet = 1,245.3 kJ/kg, qin = 2,820.7 kJ/kg, η = 44.15% (simple 41.88%, open heater at 4 bar 44.82%)
- With a 5 K terminal temperature difference: y = 0.1949, η = 44.01%
Answer: y = 0.206, η = 44.15% (+2.27 points on simple), a little below the open heater's 44.82%
Steam nozzles: critical pressure ratio, choked mass flow, friction and supersaturated flow
Which syllabus covers thisAU ME3451 Unit IIVTU BME401 Module 5SPPU not in syllabusMU MEC305 Module 6KTU PBMET604 Module 1
What does a nozzle do, and which shape do you need?
A nozzle turns the steam's enthalpy into a fast jet that then drives turbine blades. While the flow is subsonic, speeding it up needs a falling area, so a convergent nozzle is used when the back pressure is at or above the critical pressure. Once the flow is sonic, further acceleration needs a rising area, so to expand below the critical pressure you need a convergent-divergent nozzle with a throat. A purely divergent passage only accelerates flow that is already supersonic. The narrowest section, the throat, sets how much steam can pass.
How fast is the jet?
The steady-flow energy equation for an insulated nozzle with a slow inlet says the kinetic energy gained equals the enthalpy lost: V = √(2 Δh) with Δh in J/kg, which is 44.72 √Δh with Δh in kJ/kg. A drop of 100 kJ/kg gives 447 m/s; 400 kJ/kg gives 894 m/s. The isentropic drop comes from IAPWS-IF97 steam properties (the electronic Mollier chart); the area at any section then follows from continuity, A = ṁ v/V.
What is the critical pressure ratio, and why does the flow choke?
Treating the expansion as pv^n = constant, the mass flow per unit area rises as the pressure ratio falls, peaks and would then fall again. The peak is at r* = (2/(n + 1))^(n/(n − 1)): 0.546 for superheated steam (n = 1.3), 0.577 for dry saturated steam (n = 1.135) and 0.528 for air. At that ratio the throat velocity equals the local speed of sound, so pressure signals from downstream can no longer reach upstream. Lowering the back pressure further does not raise the flow: the nozzle is choked.
What does friction do to a nozzle?
Friction turns part of the jet's kinetic energy back into heat inside the steam, so the actual enthalpy drop is smaller than the isentropic one. Nozzle efficiency is the ratio of the two; the velocity coefficient is its square root (0.90 efficiency means 0.949). The reheated steam leaves drier and with a larger specific volume, so the exit area must be bigger than the frictionless design. Most of the friction is taken to act after the throat, which is why the throat is usually sized as isentropic.
What is supersaturated (metastable) flow?
In a fast nozzle the steam crosses the saturation line so quickly that droplets do not have time to form. It keeps expanding as a dry vapour colder than the saturation temperature for its pressure: supersaturated or metastable. The difference between the two temperatures is the degree of undercooling. Condensation finally happens suddenly near the Wilson line, which lies between the 4 and 5% moisture lines and is often taken as 4%. Because the vapour is denser than the equilibrium mixture, more mass flows through the same throat, while the useful enthalpy drop is slightly smaller.
Dry saturated steam flows through a convergent nozzle from 12 bar. The back pressure is lowered from 7 bar to 3 bar. The mass flow will
The flow is choked once the back pressure falls below 0.577 × 12 = 6.93 bar: the throat is then sonic and the pressure beyond it cannot affect the flow. The extra drop happens as an expansion outside the convergent nozzle. To use it you need a divergent section.
Worked examples
Convergent-divergent nozzle for dry saturated steam · Dry saturated steam at 12 bar expands to 1.5 bar, 0.8 kg/s, nozzle efficiency 0.90 with no friction before the throat (illustrative); IAPWS-IF97
- Critical ratio with n = 1.135: 0.5774, throat pressure 6.929 bar; 1.5/12 = 0.125 is far below it, so the nozzle is convergent-divergent
- Inlet: h1 = 2,783.8 kJ/kg, s1 = 6.5217 kJ/kg K; throat (isentropic): x = 0.9600, h = 2,679.7 kJ/kg, v = 0.2644 m³/kg
- Throat velocity 44.72 √104.1 = 456.2 m/s; area = 0.8 × 0.2644/456.2 = 463.7 mm²
- Exit: isentropic drop 360.3 kJ/kg, actual 0.90 × 360.3 = 324.3 kJ/kg, V = 805.3 m/s
- Exit state h = 2,459.5 kJ/kg at 1.5 bar: x = 0.8951 (isentropic would be 0.8789), v = 1.0378 m³/kg
- Exit area = 0.8 × 1.0378/805.3 = 1,031.0 mm², 2.22 times the throat
Answer: Throat 464 mm² at 6.93 bar, exit 1,031 mm², exit velocity 805 m/s
Superheated steam in a convergent nozzle · Steam at 8 bar and 270.4 °C (100 K superheat) expands to 5.6 bar, 0.5 kg/s, nozzle efficiency 0.95 (illustrative)
- 5.6/8 = 0.70 is above the critical ratio 0.546 for superheated steam: a convergent nozzle, not choked, exit pressure 5.6 bar
- h1 = 2,994.3 kJ/kg, s1 = 7.1223; isentropic to 5.6 bar: h = 2,910.5 kJ/kg, drop 83.79 kJ/kg
- Actual drop 0.95 × 83.79 = 79.60 kJ/kg, V = 44.72 √79.60 = 399.0 m/s
- Exit state is still superheated (228.9 °C), v = 0.4041 m³/kg; area = 0.5 × 0.4041/399.0 = 506.4 mm² (diameter 25.4 mm)
- Check with pv^1.3 = constant: Δh = (n/(n − 1)) p1 v1 (1 − r^((n − 1)/n)) = 83.80 kJ/kg, giving 399.0 m/s
Answer: Convergent nozzle, exit 399 m/s, exit (= throat) area 506 mm²
How much steam can a 400 mm² throat pass? · Superheated steam at 20 bar and 312.4 °C (100 K superheat), throat area 400 mm², back pressure low enough to choke (illustrative)
- Inlet specific volume (IF97) v1 = 0.12881 m³/kg
- Choked flux with n = 1.3: G* = √(n p1/v1 (2/(n + 1))^((n + 1)/(n − 1))) = √(1.3 × 20 × 10⁵/0.12881 × 0.3425) = 2629 kg/s m²
- ṁ = 2629 × 400 × 10⁻⁶ = 1.052 kg/s
- IF97 isentropic expansion to 10.91 bar: h drop 145.72 kJ/kg, v = 0.20547 m³/kg, G = 2627 kg/s m², ṁ = 1.051 kg/s
- The IF97 flux, searched over the pressure ratio, peaks at 0.546, close to the n-model's 0.546
Answer: About 1.05 kg/s by the n-model (1.051 kg/s by IF97, 0.1% apart)
Impulse steam turbine: velocity triangles, blade work and the best blade speed ratio
Which syllabus covers thisAU ME3451 Unit IIIVTU not in syllabusSPPU not in syllabusMU not in syllabusKTU PBMET604 Module 2
What makes a turbine an impulse turbine?
In an impulse stage the whole pressure drop happens in the fixed nozzles. The moving blades only turn the high-speed jet, and the force that turns the wheel is the reaction to that change of momentum, like water hitting a curved bucket. The pressure is the same on both sides of the moving blades, so there is no leakage push across them. De Laval's single-stage turbine is the simplest case: one ring of nozzles, one row of blades, a very high wheel speed and therefore reduction gearing.
How do you read the velocity triangles?
Measure angles from the direction the blades move. Steam leaves the nozzle at V1 and angle α1. Subtracting the blade speed U as vectors gives the velocity relative to the blade, Vr1 at angle β1, which is the angle the blade inlet must have. The blade turns the relative flow to β2 at its outlet, with Vr2 = k Vr1 where k is the blade friction factor. Adding U back gives the absolute exit velocity V2. Each velocity splits into a whirl component along U, which does the work, and a flow component along the axis, which carries the steam through.
Where do the work, the efficiency and the axial thrust come from?
Work per kg is U times the change in whirl velocity, U(Vw1 + Vw2), with Vw2 counted positive when it points against U. Blade (diagram) efficiency compares this with the jet's kinetic energy, 2U ΔVw/V1². The change in flow velocity, Vf1 − Vf2, pushes the rotor along its axis and must be taken by a thrust bearing. For α1 = 16°, V1 = 750 m/s, U = 300 m/s and k = 0.88, each kg of steam gives 237.4 kJ at 84.4% blade efficiency with 24.8 N of axial thrust per kg/s.
What is the best blade speed, and what limits the stage efficiency?
For symmetric blades (β2 = β1) the blade efficiency is 2ρ(cos α1 − ρ)(1 + k), with ρ = U/V1. It peaks at ρ = cos α1/2 and the peak is cos²α1 (1 + k)/2, so with α1 = 20° and frictionless blades the best is 88.3% at U/V1 = 0.470; then the steam leaves axially and only its leaving kinetic energy is lost. Stage efficiency multiplies nozzle efficiency by blade efficiency. Blades moving at half the jet speed is the catch: a 1000 m/s jet asks for blade tips near 470 m/s, which is why large turbines compound.
Symmetric frictionless impulse blades, nozzle angle 20°. Which blade speed ratio U/V1 gives the highest blade efficiency?
Efficiency 4ρ(cos α − ρ) peaks at ρ = cos α/2 = 0.470, where it equals cos²α = 0.883 and the exit velocity is axial. 0.94 is the optimum for a 50% reaction stage, and 0.23 for a two-row Curtis stage.
Worked examples
Work and thrust of a single impulse row · Nozzle angle 16°, steam velocity 750 m/s, blade speed 300 m/s, symmetric blades, blade friction factor 0.88, 2 kg/s (illustrative)
- Vw1 = 750 cos 16° = 720.9 m/s, Vf1 = 750 sin 16° = 206.7 m/s
- Relative: Vr1 = √((720.9 − 300)² + 206.7²) = 469.0 m/s at β1 = 26.16°
- Outlet: Vr2 = 0.88 × 469.0 = 412.7 m/s at β2 = 26.16°; Vw2 = 412.7 cos β2 − 300 = 70.4 m/s, Vf2 = 181.9 m/s
- ΔVw = 720.9 + 70.4 = 791.4 m/s; work = 300 × 791.4 = 237.41 kJ/kg
- Blade efficiency 2 × 300 × 791.4/750² = 84.41%; losses: blade friction 24.81 kJ/kg, leaving 19.03 kJ/kg (V2 = 195.1 m/s)
- For 2 kg/s: power 474.8 kW, tangential force 1583 N, axial thrust 2 × (206.7 − 181.9) = 49.6 N
Answer: 237.4 kJ/kg at 84.4% blade efficiency; 475 kW and 49.6 N axial thrust for 2 kg/s
Best blade speed for a 500 m/s jet · Nozzle angle 20°, steam velocity 500 m/s, symmetric blades; frictionless (k = 1) and k = 0.9 (illustrative)
- Optimum U/V1 = cos 20°/2 = 0.4698, so U = 234.9 m/s
- k = 1: η = cos²20° = 88.30%, work 110.38 kJ/kg; Vw2 = 0.0 m/s, the steam leaves axially at 171.0 m/s
- k = 0.9: η = cos²20° × (1 + 0.9)/2 = 83.89%, work 104.86 kJ/kg
- A numerical search of η over U/V1 for k = 0.9 finds the peak at 0.4698: friction does not move the optimum for symmetric blades
Answer: U = 235 m/s; blade efficiency 88.3% frictionless, 83.9% with k = 0.9
Stage efficiency with nozzle losses and unequal blade angles · Isentropic nozzle drop 150 kJ/kg, nozzle efficiency 0.94, nozzle angle 18°, blade speed 220 m/s, k = 0.86, blade outlet angle 3° less than the inlet angle (illustrative)
- V1 = 44.72 √(0.94 × 150) = 531.0 m/s, U/V1 = 0.4143
- β1 = 29.93°, so β2 = 26.93°; Vr1 = 328.9, Vr2 = 282.9 m/s
- Vw1 = 505.0, Vw2 = 32.2 m/s; work = 220 × 537.2 = 118.19 kJ/kg
- Blade efficiency 2 × 220 × 537.2/531.0² = 83.82% (symmetric blades would give 82.72%)
- Stage efficiency 0.94 × 0.8382 = 78.79% = 118.19/150
Answer: Stage efficiency 78.8% (118.2 kJ/kg of the 150 kJ/kg available)
Reaction turbines, degree of reaction, compounding, reheat factor and governing
Which syllabus covers thisAU ME3451 Unit IIIVTU not in syllabusSPPU not in syllabusMU not in syllabusKTU PBMET604 Module 2
How is a reaction stage different from an impulse stage?
In a reaction stage the moving blades are shaped like nozzles too, so the steam keeps expanding and speeding up relative to them; the rotor is pushed both by the turning of the jet and by the reaction of the steam accelerating out of it. Pressure therefore falls across fixed and moving rows alike. The degree of reaction R is the enthalpy drop in the moving blades divided by the drop in the whole stage: 0 for a pure impulse stage, 0.5 when the drop is shared equally.
Why is the 50% reaction (Parsons) stage special, and how does it compare with impulse?
With R = 0.5 the fixed and moving blades can share one profile, and the inlet and outlet triangles are mirror images. Counting the energy supplied as V1²/2 plus the rise in relative kinetic energy in the moving row, the efficiency peaks at U/V1 = cos α1 with a value 2cos²α1/(1 + cos²α1): 93.8% at 20°, above the impulse stage's 88.3% at U/V1 = 0.47 (each on its usual definition). The price is speed: at their optima a reaction stage does work U², an impulse stage 2U², so reaction turbines need more stages, and the pressure difference across moving blades needs tight tip clearances and a balance piston.
Why compound a turbine, and what are the three ways?
Taking a big drop in one impulse stage makes a very fast jet and wants blades at half its speed: expanding steam from 20 bar, 300 °C to 2 bar gives a 958 m/s jet and a best blade speed of 450 m/s at 20°. Velocity compounding (Curtis) keeps one nozzle drop but absorbs the jet in two moving rows with a fixed guide row between, halving the blade speed. Pressure compounding (Rateau) splits the drop over several nozzle-and-wheel stages. Pressure-velocity compounding combines both. Reaction turbines are naturally many-staged.
What are the condition line, stage efficiency and reheat factor?
Plot the actual steam state after each stage on the h-s chart and join them: that is the condition line. Each stage's losses reheat the steam, so the next stage starts at a higher entropy, where the isobars spread out and the available isentropic drop is larger. Summing the stage isentropic drops therefore gives more than the single overall isentropic drop; their ratio is the reheat factor, 1.03 to 1.04 typical. The turbine's overall efficiency is the stage efficiency times the reheat factor: three stages at 75% from 20 bar, 350 °C to 1 bar give RF = 1.038 and 77.8% overall.
How is a steam turbine's speed held constant as the load changes?
A centrifugal (fly-ball) governor senses speed: when load rises the speed falls, the balls drop and, through an oil relay, open the steam supply further. Throttle governing narrows the main valve, which wastes availability in the throttling. Nozzle governing shuts off whole groups of first-stage nozzles (typically three to five or more groups), so the steam that does flow is not throttled, which is better at part load. By-pass governing sends extra steam past the first stages into later ones to carry an overload.
For the same enthalpy drop per stage and each stage at its best U/V1, which needs the higher blade speed?
At its optimum an impulse stage does work 2U² per kg and a 50% reaction stage U². For the steam example (459 kJ/kg in three stages) that is 260 m/s for a Rateau stage against 391 m/s for a Parsons stage, which is why reaction turbines carry more stages.
Worked examples
A 50% reaction stage · Fixed and moving blade exit angle 20°, steam velocity from the fixed row 200 m/s, blade speed 160 m/s, 25 kg/s (illustrative)
- Vw1 = 200 cos 20° = 187.94 m/s, Vf = 68.40 m/s; Vr1 = √((187.94 − 160)² + 68.40²) = 73.89 m/s at β1 = 67.78°
- Symmetric blades: Vr2 = V1 = 200 m/s at 20°, so Vw2 = 200 cos 20° − 160 = 27.94 m/s and V2 = Vr1
- Work = 160 × (187.94 + 27.94) = 34.540 kJ/kg
- Energy supplied = 200²/2 + (200² − 73.89²)/2 = 37.270 kJ/kg, η = 92.68% (best 93.79% at U = 187.9 m/s)
- Enthalpy drop: fixed row 17.270 kJ/kg, moving row 17.270 kJ/kg, so R = 0.50
- Power for 25 kg/s: 25 × 34.540 = 863.5 kW per stage
Answer: 34.54 kJ/kg, η = 92.7%, R = 0.5, 864 kW per stage
Reheat factor of a three-stage turbine · Steam at 20 bar, 350 °C expands to 1 bar in three stages of equal pressure ratio, each with isentropic stage efficiency 0.75 (illustrative); IAPWS-IF97
- Pressure ratio per stage (1/20)^(1/3) = 0.3684: stage exits 7.368, 2.714 and 1 bar
- Overall isentropic drop 20 → 1 bar: 612.0 kJ/kg (h1 = 3,137.6 kJ/kg)
- Stage 1: isentropic 247.5, actual 0.75 × 247.5, h = 2,952.0 kJ/kg
- Stage 2 (from the reheated state): isentropic 209.2, h = 2,795.1; stage 3: isentropic 178.2, h = 2,661.4 kJ/kg (x = 0.994)
- RF = (247.5 + 209.2 + 178.2)/612.0 = 635.0/612.0 = 1.0376
- Turbine efficiency = (3,137.6 − 2,661.4)/612.0 = 77.82% = 0.75 × 1.0376
Answer: Reheat factor 1.038; overall efficiency 77.8% from 75% stages
What compounding does to blade speed · Steam at 20 bar, 300 °C expands isentropically to 2 bar, nozzle angle 20°; each arrangement at its best blade speed, frictionless; wheel to run at 3000 rpm, the two-pole speed on a 50 Hz grid (illustrative)
- Isentropic drop (IF97) 459.0 kJ/kg; one nozzle gives V1 = 44.72 √459.0 = 958.1 m/s
- Single impulse stage: U = V1 cos 20°/2 = 450.2 m/s, mean diameter at 3000 rpm 60U/(πN) = 2.87 m
- Two-row Curtis: U = V1 cos 20°/4 = 225.1 m/s, diameter 1.43 m; the second row's exit is axial and the stage still reaches cos²20° = 88.3%
- Three Rateau stages of 153.0 kJ/kg: V1 = 553.2 m/s, U = 259.9 m/s, diameter 1.65 m
- Three Parsons stages at U/V1 = cos 20° (stage work U²): U = √(153.0 × 1000) = 391.1 m/s, diameter 2.49 m
Answer: Blade speed 450 m/s for one stage, 225 (Curtis), 260 (Rateau ×3), 391 m/s (Parsons ×3)
IC engines: classification, two-stroke and four-stroke, and port timing
Which syllabus covers thisAU ME3451 Unit IVVTU BME401 Module 1SPPU 202048 Unit IIMU MEC502 Module 5KTU PBMET604 Module 3
How are IC engines classified, and what are the main parts?
By ignition: spark ignition (petrol, CNG, LPG) or compression ignition (diesel). By cycle: four-stroke or two-stroke. By cooling: air-cooled (most two-wheelers) or liquid-cooled (most cars and trucks). By layout: single, inline, V or opposed cylinders, and by fuel supply: carburettor, port injection or direct injection. The parts are the same everywhere: a cylinder and head, a piston with rings that seal the gas and scrape oil, a connecting rod and crankshaft that turn the piston's push into torque, and, in a four-stroke, valves opened by a camshaft driven at half crank speed.
How does a two-stroke engine do in one revolution what a four-stroke does in two?
A four-stroke uses separate strokes for intake, compression, power and exhaust, so each cylinder fires once every two revolutions. A crankcase-scavenged two-stroke fires every revolution: as the piston rises it compresses the charge above and draws fresh mixture into the sealed crankcase below; as it falls after combustion it uncovers the exhaust port, then the transfer ports, and the slightly compressed crankcase charge flows up and pushes the burnt gas out. That is scavenging. The price is short-circuiting: some fresh mixture escapes straight out of the exhaust, which is why carburetted two-strokes were thirsty and dirty.
What sets the port timing of a two-stroke, and why must the exhaust open first?
The piston is the valve: a port opens when the crown passes its top edge, so the timing is fixed by the port height and the slider-crank geometry, and it is symmetric about BDC. The exhaust port is taller, so it opens first; during that blowdown the cylinder pressure falls below the crankcase pressure, otherwise burnt gas would blow back into the transfer passages. In a 58 mm stroke, 110 mm rod engine, ports 17 and 12 mm tall open 73° and 61° before BDC, a blowdown of 12°, only 0.33 ms at 6,000 rpm.
How do SI and CI engines differ?
A spark-ignition engine draws in a premixed fuel-air charge, ignites it with a spark and controls load with a throttle that limits the quantity of mixture, keeping the ratio near stoichiometric. A compression-ignition engine draws in air only, compresses it until it is hot enough to ignite fuel injected near TDC, and controls load by the quantity of fuel, with no throttle. Because only air is compressed, a diesel can use compression ratios of about 15 to 22 (typical) against 8 to 12 for petrol (typical), so it is more efficient, but heavier and slower-revving for its power.
Why do real four-stroke valves not open and close exactly at TDC and BDC?
Gas has inertia and the valves need time to lift. The intake valve opens before TDC and closes well after BDC so the moving charge keeps filling the cylinder; the exhaust valve opens before BDC so the pressure blows down before the piston has to push the gas out, and closes after TDC. Near TDC both are open together: the valve overlap. A two-stroke has no valves, which is why port timing replaces valve timing here. The Automobile Engineering book has a valve-timing interactive that shows the overlap and what variable valve timing changes.
A tuner files the top of the exhaust port 2 mm higher and leaves the transfer ports alone. The blowdown angle will
The exhaust opens when the crown passes the port's top edge. A taller port is uncovered earlier, while the transfer ports open at the same angle, so the gap between them grows. In the 58 mm stroke engine, raising the exhaust edge from 17 to 19 mm moves the exhaust opening from 73.1° to 77.5° before BDC, and the blowdown grows from 12.0° to 16.4°.
Worked examples
Port timing of a 150 cc two-stroke · Bore 57 mm, stroke 58 mm (r = 29 mm), connecting rod 110 mm; exhaust port top 17 mm and transfer port top 12 mm above the piston crown at BDC (illustrative)
- Swept volume = π/4 × 5.7² × 5.8 = 148.0 cc
- Exhaust opens when the piston is 58 − 17 = 41 mm from TDC; with q = l + r − x = 98 mm, cos θ = (q² − l² + r²)/(2rq) = (9,604 − 12,100 + 841)/5,684 = −0.2912
- θ = 106.93° after TDC, i.e. 73.07° before BDC; it closes symmetrically at 73.07° after BDC
- Transfer: x = 46 mm, q = 93 mm, cos θ = (8,649 − 12,100 + 841)/5,394 = −0.4839, θ = 118.94°, i.e. 61.06° before BDC
- Blowdown = 118.94 − 106.93 = 12.01°; exhaust open 146.1°, transfer open 122.1°
Answer: Exhaust opens 73.1° before BDC, transfer 61.1° before BDC, blowdown 12.0°, exhaust open for 146.1° of crank
Port height for a chosen exhaust opening, and the time it allows · Same engine; the designer wants the exhaust to open 85° before BDC (illustrative) and asks how long the original 12° blowdown lasts at 6,000 rpm
- 85° before BDC = 95° after TDC: x = 29(1 − cos 95°) + 110 − √(110² − 29² sin² 95°) = 35.39 mm from TDC
- Port top edge = 58 − 35.39 = 22.61 mm above the crown at BDC (it was 17 mm)
- At 6,000 rpm the crank turns 100 rev/s = 36,000°/s
- Original blowdown 12.01° lasts 12.01/36,000 s = 0.334 ms
Answer: Port top 22.6 mm above BDC crown; the 12.0° blowdown lasts only 0.33 ms at 6,000 rpm, which is why high-speed engines need taller exhaust ports
Trapped compression ratio of the two-stroke · Same engine with a geometric compression ratio of 10 over the full stroke (illustrative); compression really starts only when the piston closes the exhaust port
- Clearance volume Vc = Vs/(r − 1) = 148.0/9 = 16.44 cc
- Piston area = π/4 × 5.7² = 25.52 cm²; stroke left after the exhaust closes = 58 − 17 = 41 mm
- Volume trapped = 16.44 + 25.52 × 4.1 = 121.1 cc
- Trapped compression ratio = 121.1/16.44 = 7.36
Answer: Trapped ratio 7.36, well below the geometric 10, because 29% of the stroke is lost to the exhaust port
Fuels and combustion air: stoichiometric and excess air, equivalence ratio and flue gas
Which syllabus covers thisAU ME3451 Unit IVVTU not in syllabusSPPU 202048 Unit VMU not in syllabusKTU PBMET604 Module 4
What makes a good SI fuel and a good CI fuel?
A petrol must vaporise easily and resist autoignition, measured by its octane number; Indian petrol is sold as 91 and 95 RON grades. A diesel must do the opposite: ignite quickly once injected into hot air, measured by its cetane number (48 in the Indian specification since 2000), and it needs lower volatility and enough viscosity to lubricate the pump. Calorific value is quoted two ways: the higher value counts the heat of condensing the water formed, the lower does not, because engines exhaust that water as vapour. Per kg, petrol gives 46.4 and 43.4 MJ, diesel 45.6 and 42.6 MJ.
How much air does it take to burn a fuel completely?
Write the reactions: C + O2 → CO2, H2 + ½O2 → H2O, S + O2 → SO2. Per kg of each element that is 2.664 kg of oxygen for carbon, 7.936 for hydrogen and 0.998 for sulphur, less any oxygen already in the fuel. Dry air is 20.95 % oxygen by volume and 23.14 % by mass (argon counted with the nitrogen), so the minimum air is the oxygen divided by 0.2314. Many textbooks round to 21 % and 23 %, which shifts the answer by under 1 %. Iso-octane needs 15.13 kg of air per kg; C12H23, a common diesel formula, needs 14.67.
What are excess air, equivalence ratio and lambda, and what do lean and rich mean?
Excess air is the air supplied beyond the stoichiometric amount. Lambda is actual air over stoichiometric air; the equivalence ratio φ is actual fuel-air ratio over stoichiometric, so φ = 1/λ. Lean means λ > 1: oxygen is left over. Rich means λ < 1: some carbon leaves as CO. Petrol engines run near λ = 1 for the catalyst, diesels run lean (λ well above 1) and boilers use 10 to 50 % excess air (typical). A mixture burns only between its flammability limits: petrol vapour 1.4 to 7.6 % by volume in air, while stoichiometric iso-octane vapour is 1.65 %.
Why is flue gas analysed dry, and how does the Orsat apparatus work?
A gas sample cooled to room temperature loses most of its water vapour, so classic instruments report the dry composition. The Orsat apparatus passes a measured volume through absorbents in turn: potassium hydroxide takes the CO2, alkaline pyrogallol the O2, cuprous chloride the CO, and the remainder is taken as nitrogen. The dry CO2 tells you the excess air: for methane it is 11.7 % at λ = 1 and falls as air is added, while O2 rises. Too little CO2 means heat wasted heating excess air; any CO means air is short or mixing is poor.
Why is petrol quoted at 14.7 when iso-octane works out at 15.1?
The ratio depends on the hydrogen-to-carbon ratio of the fuel. Iso-octane, C8H18, has 2.25 hydrogen atoms per carbon and needs 15.13 kg of air per kg. Market petrol contains aromatics and olefins with less hydrogen per carbon, so it needs a little less air, and about 14.7 is the value usually used for it (typical). The C12H23 diesel formula gives 14.67, close to the value of about 14.5 quoted for diesel (typical). Ethanol, which already carries oxygen, needs only about 9, so an engine must inject far more of it for the same air.
A boiler's Orsat reading shows dry CO2 falling from 13 % to 9 % with no CO. The air supply has
Each kg of carbon makes the same CO2 whatever the air, but every extra kg of air adds nitrogen and unused oxygen to the dry gas, so the CO2 share falls. For methane, 9.0 % dry CO2 means λ = 1.268, about 27% excess air. A rich mixture would show CO, not lower CO2 with no CO.
Worked examples
Stoichiometric air for iso-octane and for diesel · Petrol modelled as iso-octane C8H18, diesel as C12H23; air 20.946 % O2 by volume, molar mass 28.96 kg/kmol
- C8H18 + 12.5 O2 → 8 CO2 + 9 H2O; air = 12.5/0.20946 = 59.677 kmol per kmol of fuel
- Air mass = 59.677 × 28.964 = 1,728.5 kg per 114.23 kg of fuel, so A/F = 15.13
- C12H23 needs 12 + 23/4 = 17.75 O2 → 12 CO2 + 11.5 H2O; air = 17.75/0.20946 = 84.742 kmol
- Fuel molar mass = 12 × 12.011 + 23 × 1.008 = 167.32; A/F = 84.742 × 28.964/167.32 = 14.67
Answer: Iso-octane 15.13 : 1, diesel (C12H23) 14.67 : 1
Minimum and actual air for a coal, and its dry flue gas · Coal as fired (illustrative): C 70 %, H 4.5 %, O 7 %, N 1.5 %, S 1 %, moisture 4 %, ash 12 % by mass; burnt with 40 % excess air
- O2 needed = 2.664 × 0.70 + 7.936 × 0.045 + 0.998 × 0.01 − 0.07 = 2.162 kg per kg of coal
- Minimum air = 2.162/0.2314 = 9.343 kg; actual air = 1.4 × 9.343 = 13.08 kg
- Dry gas per kg: CO2 0.70/12.011 = 0.0583 kmol, SO2 0.00031, excess O2 0.4 × 0.0676 = 0.0270, N2 0.3575; total 0.4432 kmol
- Dry analysis: CO2 13.15 %, O2 6.10 %, SO2 0.07 %, N2 80.68 %
- Water (0.0245 kmol from hydrogen and moisture) is removed in the dry analysis; counted wet, CO2 falls to 12.46 %
Answer: Minimum air 9.34 kg/kg, actual 13.08 kg/kg; dry flue gas 13.2 % CO2, 6.1 % O2
Excess air from an Orsat reading · Natural gas taken as methane; the dry flue gas shows 9.0 % CO2 and no CO (illustrative reading)
- CH4 + 2λ (O2 + 3.774 N2) → CO2 + 2 H2O + 2(λ − 1) O2 + 7.549λ N2
- Dry moles = 1 + 2(λ − 1) + 7.549λ = 9.549λ − 1, so 100/(9.549λ − 1) = 9.0
- λ = (100/9.0 + 1)/9.549 = 1.2684: excess air 26.8 %, φ = 0.788
- Check: dry O2 = 2 × 0.2684/11.111 = 4.83 %; A/F = 1.2684 × 17.24 = 21.87
Answer: λ = 1.268 (26.8 % excess air), φ = 0.788, A/F 21.9, with 4.8 % O2 in the dry gas
Combustion in SI and CI engines: burn rate, spark advance, knock and the delay period
Which syllabus covers thisAU ME3451 Unit IVVTU BME401 Module 1SPPU 202048 Units III, VMU MEC502 Module 5KTU PBMET604 Module 4
What are the stages of combustion in a spark-ignition engine?
Ricardo described three. First, ignition lag: the spark makes a small flame kernel that grows slowly, with little pressure rise, for the first few per cent of the charge; this takes a roughly fixed time, so more crank degrees at higher speed. Second, flame propagation: a turbulent flame sweeps across the chamber, the pressure rises steeply and most of the mass burns. Third, after-burning: the flame reaches the walls and the last pockets burn slowly as the piston descends. Turbulence, mixture strength and chamber shape decide how fast the second stage goes.
How is the burn rate modelled, and what is MBT spark timing?
The Wiebe function gives the mass fraction burned against crank angle; a = 5 and m = 2 are the values commonly used for petrol, which puts 99.3 % burned at the end of the nominal duration. Fire too late and the gas burns while expanding; too early and the piston compresses burning gas, wasting work. The advance with the most torque is MBT, maximum brake torque timing. In the interactive's single-zone model (compression ratio 10, 50° burn, 3,000 rpm) MBT is about 26° before TDC, with peak pressure about 10° after TDC.
What is knock in an SI engine, and what makes it worse?
As the flame advances it compresses and heats the unburned end gas. If that gas autoignites before the flame arrives, it releases its energy almost at once, and pressure waves ring through the chamber: knock, which can melt pistons. Higher compression ratio, hotter or denser intake, more spark advance, a long flame path and low octane all make it worse; turbulence and faster burning help. Octane number is the percentage of iso-octane in an iso-octane and n-heptane blend that knocks like the fuel. In the interactive's model with 95 RON, the knock integral passes 1 before MBT, so the spark is held at about 23° before TDC, costing 0.3 % of IMEP.
What are the stages of combustion in a diesel engine, and what is diesel knock?
Fuel injected into hot air does not ignite at once. During the delay period it atomises, evaporates and mixes. When it ignites, everything prepared during the delay burns almost together: rapid or premixed combustion, the steep pressure rise. Then fuel burns as fast as it is injected and mixes: controlled combustion. After injection ends, after-burning finishes the job. A long delay piles up fuel, so the premixed burn is violent: diesel knock. It is the opposite of petrol knock, cured by fuel that ignites easily (high cetane), higher compression and hotter air, the very things that cause knock in a petrol engine.
What do cetane number and combustion chamber design do?
Cetane number is the percentage of n-cetane in a blend with alpha-methylnaphthalene (or heptamethylnonane on the newer scale) that has the same ignition delay as the fuel; higher means a shorter delay and quieter running. Chambers follow the fuel: petrol engines use compact pent-roof or hemispherical heads with a central plug to shorten the flame path and resist knock. Diesels use either an open (direct-injection) bowl in the piston with high injection pressure, or a divided pre-chamber or swirl chamber (indirect injection) that mixes well with simpler injection but loses heat, so it needs glow plugs to start.
An engine is running at MBT spark timing. You advance the spark a further 10°. Torque will
At MBT the losses from burning too early and too late balance. More advance moves combustion before TDC, so the piston does extra work compressing hot burning gas and the peak pressure climbs. In the interactive's model (compression ratio 10, 50° burn) MBT is 26° before TDC; going past it lowers IMEP and also raises the knock integral.
Worked examples
Burn angles from the Wiebe function · Wiebe a = 5, m = 2, spark at 20° before TDC, burn duration 50° (burn taken to start at the spark)
- Invert x = 1 − exp(−5u³): u = (−ln(1 − x)/5)^(1/3), θ = −20° + 50u
- 10 % burned: u = (0.1054/5)^(1/3) = 0.2762, θ = −6.19° (before TDC)
- 50 % burned: u = (0.6931/5)^(1/3) = 0.5175, θ = +5.88° after TDC
- 90 % burned: u = (2.3026/5)^(1/3) = 0.7722, θ = +18.61°
- 10-90 % burn takes 24.8°; at the end of the 50° duration x = 1 − e⁻⁵ = 0.9933
Answer: 10 % at −6.2°, 50 % at +5.9°, 90 % at +18.6°; the main burn spans 24.8° of crank
End-gas ignition delay by the Douaud-Eyzat correlation · End gas at 60 bar and 850 K (illustrative), 95 RON petrol, engine at 3,000 rpm; τ = 17.68 (ON/100)^3.402 p^−1.7 exp(3800/T) ms, p in atm
- p = 60 × 10⁵/1,01,325 = 59.22 atm
- τ = 17.68 × 0.95^3.402 × 59.22^−1.7 × exp(3800/850) = 1.26 ms
- At 3,000 rpm the crank turns 18,000°/s = 18° per ms, so τ = 22.7° of crank
- With 91 RON, τ is multiplied by (91/95)^3.402 = 0.864: 1.09 ms
- If the end gas reached 900 K instead, τ = 0.98 ms: 50 K of extra heating cuts the delay by 22 %
Answer: About 1.26 ms (23° of crank); lower octane or hotter end gas shortens it, and if it ends before the flame arrives, the engine knocks
Delay period and spark lag in crank degrees · A diesel with a 1.0 ms ignition delay and fuel injected evenly over 20° of crank; a petrol engine whose flame takes 1.2 ms to establish (both illustrative)
- Crank degrees = time × rpm × 6 / 1,000 (rpm × 360/60 degrees per second, time in ms)
- Diesel delay at 1,500 rpm = 1.0 × 1,500 × 6/1,000 = 9.0°; at 3,000 rpm = 18.0°
- Fuel injected before ignition: 9/20 = 45 % at 1,500 rpm, 90 % at 3,000 rpm if the delay time stayed the same
- Petrol flame lag at 1,500 rpm = 10.8°, at 4,500 rpm = 32.4°: the spark must move earlier as speed rises
Answer: Diesel delay 9° → 18° and petrol lag 10.8° → 32.4° as speed rises; this is why ignition systems advance the spark with speed
Emissions, Bharat Stage norms, after-treatment and engine systems
Which syllabus covers thisAU ME3451 Unit VVTU not in syllabusSPPU 202048 Units IV, VMU MEC502 Module 6KTU PBMET604 Modules 3, 4
Where does each pollutant come from?
Carbon monoxide comes from rich mixtures, where there is not enough oxygen to finish the carbon. Unburned hydrocarbons come from fuel hidden in crevices around the piston rings, flame quenching at cold walls and, in two-strokes, short-circuited charge. Nitrogen oxides form from the air's own nitrogen and oxygen at high flame temperature, so they peak just lean of stoichiometric. Particulate matter is soot from fuel-rich pockets in a diesel spray. CO2 is not a pollutant in the toxic sense but scales with fuel burned. In a diesel, NOx and PM trade off: hotter, faster burning cuts soot but makes NOx, and the reverse.
How are the pollutants measured?
Carbon monoxide and CO2 are measured by non-dispersive infrared (NDIR) absorption: each molecule absorbs its own infrared band, so the dimming of that band gives the concentration. Hydrocarbons are measured with a flame ionisation detector (FID): carbon atoms burnt in a hydrogen flame produce ions, and the current is proportional to the carbon count. NOx is measured by chemiluminescence: NO reacting with ozone emits light. Diesel smoke is measured as opacity with a smoke meter (light through the exhaust) or as particulate mass collected on a filter from diluted exhaust. Type-approval tests run the vehicle on a chassis dynamometer through a fixed driving cycle; truck engines run on an engine dynamometer.
How do catalysts, filters, EGR and SCR clean the exhaust?
A three-way catalyst oxidises CO and HC and reduces NOx at the same time, but only in a narrow window around λ = 1, so petrol engines use an oxygen sensor in closed-loop control. A diesel runs lean, so its oxidation catalyst handles CO and HC only. A diesel particulate filter traps soot in porous walls and burns it off periodically. Exhaust gas recirculation dilutes the charge with inert gas, lowering flame temperature and NOx. Selective catalytic reduction injects a urea solution that becomes ammonia and reduces NOx to nitrogen and water over a catalyst; BS VI trucks rely on it.
What are the Bharat Stage norms, and what changed at BS VI?
India's emission norms follow the European stages for four-wheelers. BS III applied nationwide from April 2010 and BS IV from April 2017; BS V was skipped and BS VI applied from 1 April 2020, with real driving emission limits from April 2023. For a diesel car, BS VI cuts NOx from 0.25 to 0.080 g/km (68 %) and PM from 0.025 to 0.0045 g/km (82 %). Cars are tested on the NEDC, top speed capped at 90 km/h for low-powered vehicles; two-wheelers moved from the India Drive Cycle to the WMTC at BS IV.
How do MPFI, GDI and CRDi supply fuel, and how is the spark made?
Multipoint port fuel injection (MPFI) sprays petrol at each intake port under electronic control, replacing the carburettor and holding λ close to 1. Gasoline direct injection (GDI) sprays into the cylinder itself, cooling the charge and allowing more compression, but it can make soot, which is why BS VI sets a PM limit for it. Common-rail diesel injection (CRDi) keeps fuel at very high pressure in a rail and fires several precisely timed injections per cycle. Spark systems: a battery and coil, a magneto on small engines without a battery, and capacitor-discharge (CDI) or transistorised (TCI) electronic ignition with timing advanced as speed rises.
What do cooling, lubrication, charging, VVT, VGT and HCCI add?
Cooling keeps walls and oil within limits: air fins on small engines, a water jacket and radiator on most others. Lubrication is by splash in small engines or a pressure pump feeding the bearings in most. Supercharging drives a compressor from the crankshaft, turbocharging drives it from exhaust energy; both pack more air into each cycle (the Automobile Engineering book's turbo interactive shows the charge heating and intercooling). Variable valve timing shifts the cams with speed and load; a variable geometry turbine adjusts its vanes so the turbo responds at low speed. HCCI compresses a premixed charge until it autoignites everywhere: high efficiency, low NOx, hard to control.
BS VI cut a diesel car's NOx limit from 0.25 to 0.080 g/km but left CO at 0.50 g/km. Why did CO hardly need tightening?
A diesel always has excess oxygen, so little CO forms, and the oxidation catalyst burns most of what does. NOx and PM are the diesel's hard pollutants, which is why BS VI cut them by 68 % and 82 % and in practice needs EGR or SCR and a particulate filter.
Worked examples
How much did BS VI tighten the limits? · Diesel car (M1) limits from DieselNet, g/km: BS IV NOx 0.25, HC+NOx 0.30, PM 0.025; BS VI NOx 0.080, HC+NOx 0.17, PM 0.0045. Truck engines on the steady-state test, g/kWh: NOx 3.5 → 0.40 (ESC to WHSC)
- NOx: (1 − 0.080/0.25) × 100 = 68 %
- PM: (1 − 0.0045/0.025) × 100 = 82 %; HC+NOx: (1 − 0.17/0.30) × 100 = 43.3 %; CO unchanged at 0.50
- Petrol car NOx: 0.08 → 0.06 g/km, a 25 % cut
- Truck engine NOx: (1 − 0.40/3.5) × 100 = 88.6 %, PM 0.02 → 0.01 g/kWh = 50 % (on a different test cycle, so not exactly like for like)
Answer: Diesel car NOx −68 %, PM −82 %; truck engine NOx −88.6 %
Does this petrol car pass BS VI? · Illustrative type-approval result for a petrol car: CO 0.62, HC 0.071, NOx 0.072 g/km; BS VI petrol limits CO 1.0, HC 0.10, NOx 0.06 g/km; the car covers 12,000 km a year
- CO 0.62 ≤ 1.0: pass; HC 0.071 ≤ 0.10: pass
- NOx 0.072 > 0.06: fail, 20 % over the limit
- A car exactly at the BS VI NOx limit emits 12,000 × 0.06 = 720 g = 0.72 kg a year
- At the BS III petrol limit (0.15 g/km) it would be 1.80 kg: 2.5 times as much
Answer: Fails on NOx (20 % over); a car at the BS VI limit emits 0.72 kg of NOx a year against 1.8 kg at BS III
Urea needed by an SCR system · Truck engine at 150 kW with 6.0 g/kWh engine-out NOx (illustrative), to meet the BS VI WHSC limit of 0.40 g/kWh; NOx counted as NO2 (46.01 g/mol); urea (NH2)2CO + H2O → 2 NH3 + CO2, then 4 NO + 4 NH3 + O2 → 4 N2 + 6 H2O
- NOx to remove = (6.0 − 0.40) × 150 = 840 g/h, a conversion of 93.3 %
- Moles = 840/46.01 = 18.26 mol/h; one NH3 per NOx, and one urea gives two NH3
- Urea = 18.26/2 × 60.06 g/mol = 548 g/h
- Atom check: urea + water (C1 O2 N2 H6) = 2 NH3 + CO2 (N2 H6 C1 O2); 4 NO + 4 NH3 + O2 (N8 O6 H12) = 4 N2 + 6 H2O
Answer: About 548 g of urea per hour (dosed as a water solution) to convert 93 % of the NOx
Engine performance: indicated and brake power, efficiencies, BSFC and the heat balance sheet
Which syllabus covers thisAU ME3451 Unit VVTU BME401 Module 1SPPU 202048 Unit IVMU MEC502 Module 6KTU PBMET604 Module 3
What is the difference between indicated power and brake power, and how is each measured?
Indicated power is the rate at which the gas does work on the pistons. It comes from the indicator (p-V) diagram: its area divided by the swept volume is the indicated mean effective pressure pmi, and IP = pmi L A N n/(60 k) in watts, with pmi in Pa, stroke L in m, piston area A in m², speed N in rpm, n cylinders and k = 2 for a four-stroke (one power stroke every two revolutions), 1 for a two-stroke. Brake power is what reaches the crankshaft, measured on a dynamometer (an eddy-current or hydraulic brake) as torque T at speed N. The difference is friction power, FP = IP − BP.
Which efficiencies describe an engine, and how are they linked?
Mechanical efficiency ηm = BP/IP tells how much of the gas work survives friction and pumping. Indicated thermal efficiency ηith = IP/(ṁf × LCV) and brake thermal efficiency ηbth = BP/(ṁf × LCV) compare power with the fuel's heat; ηbth = ηm × ηith. Volumetric efficiency ηv is the air actually drawn in divided by the air that would fill the swept volume at ambient density, about 85% for the illustrative single-cylinder diesel below. LCV (lower calorific value) is used because the water in the exhaust leaves as vapour; diesel's LCV is 42.6 MJ/kg.
What is BSFC and why do engineers quote it instead of efficiency?
Brake specific fuel consumption is fuel mass per unit of brake energy, in g/kWh. It is measured directly (weigh the fuel, read the dynamometer) and needs no assumed calorific value, so it is the number on test reports and engine maps. With LCV in MJ/kg, ηbth = 3600/(BSFC × LCV): 255 g/kWh of diesel is a brake thermal efficiency of 33.2%. The air-fuel ratio follows from the two measured flows; diesels run lean, so A/F well above the stoichiometric value is normal.
What is a heat balance sheet and what does the unaccounted line mean?
It is an account of where the fuel's heat goes during a steady test: heat supplied ṁf × LCV equals brake power, plus heat to the cooling water (ṁw cp ΔT), plus heat carried out by the exhaust (ṁg cp (Tex − Tambient), with ṁg = air + fuel), plus an unaccounted remainder: radiation and convection from the block, oil cooling, incomplete combustion and measurement error. For the illustrative four-cylinder diesel below the split is 33.2% brake power, 26.5% water, 25.7% exhaust and 14.6% unaccounted. A negative remainder means a reading is wrong.
On a test bed the dynamometer load is raised at constant speed. Mechanical efficiency will
Friction power depends mainly on speed, not load. At constant speed it is roughly fixed, so ηm = BP/(BP + FP) climbs as BP grows; at idle with no load it is zero. That is why part-load operation wastes fuel.
Worked examples
Indicated, brake and friction power of a single-cylinder diesel · Four-stroke, bore 95 mm, stroke 115 mm, indicated mean effective pressure 7.4 bar, 1,500 rpm, brake torque 38 N·m (illustrative test-bed readings)
- Piston area A = π/4 × 0.095² = 7.0882 × 10⁻³ m²; swept volume = A × L = 815.1 cm³
- Four-stroke: N/2 = 750 power strokes per minute. IP = 7.4 × 10⁵ × 0.115 × 7.0882 × 10⁻³ × 1,500/(60 × 2) = 7,540 W = 7.54 kW
- BP = 2π × 1,500 × 38/60,000 = 5.969 kW
- FP = 7.54 − 5.97 = 1.57 kW; ηm = 5.969/7.540 = 79.2%
Answer: IP 7.54 kW, BP 5.97 kW, FP 1.57 kW, mechanical efficiency 79.2%
BSFC, thermal efficiencies, A/F and volumetric efficiency · Same engine and load (BP 5.97 kW, IP 7.54 kW). Fuel 1.52 kg/h of diesel (LCV 42.6 MJ/kg), air 36.5 kg/h, ambient 1.01325 bar and 30 °C
- Heat supplied = 1.52/3,600 × 42,600 = 17.99 kW
- BSFC = 1,520 g/h ÷ 5.969 kW = 254.6 g/kWh; ηbth = 5.969/17.99 = 33.2% (check: 3,600/(254.6 × 42.6) = 33.2%)
- ηith = 7.540/17.99 = 41.9%; A/F = 36.5/1.52 = 24.0
- Air density = 101.325/(0.287 × 303.15) = 1.1646 kg/m³; swept volume rate = 815.1 cm³ × 750 × 60 = 36.68 m³/h
- ηv = 36.5/(1.1646 × 36.68) = 36.5/42.72 = 85.4%
Answer: BSFC 255 g/kWh, ηbth 33.2%, ηith 41.9%, A/F 24.0, ηv 85.4%
Heat balance sheet of a four-cylinder diesel · 2,000 rpm, torque 210 N·m, fuel 11.2 kg/h (LCV 42.6 MJ/kg), cooling water 18 kg/min rising 28 K (cp 4.18 kJ/kg K), A/F 23, exhaust 470 °C, ambient 32 °C (illustrative readings); exhaust treated as air with DieselNet's enthalpy table
- Heat supplied = 11.2/3,600 × 42,600 = 132.53 kW
- BP = 2π × 2,000 × 210/60,000 = 43.98 kW
- Cooling water = 18/60 × 4.18 × 28 = 35.11 kW
- Exhaust flow = 11.2 × (1 + 23)/3,600 = 0.0747 kg/s; h(743 K) − h(305 K) = 761.4 − 305.5 = 455.9 kJ/kg (mean cp 1.041); exhaust heat = 0.0747 × 455.9 = 34.04 kW
- Unaccounted = 132.53 − 43.98 − 35.11 − 34.04 = 19.40 kW
Answer: BP 33.2%, cooling water 26.5%, exhaust 25.7%, unaccounted 14.6% of 132.5 kW
Measuring friction power: Willans line, Morse test, retardation test and performance curves
Which syllabus covers thisAU ME3451 Unit VVTU BME401 Module 1SPPU 202048 Unit IVMU MEC502 Module 6KTU PBMET604 Module 3
How does the Willans line find friction power, and why only for a diesel?
Run the engine at constant speed, measure fuel flow at several loads and plot fuel against brake power. A diesel is governed by the quantity of fuel injected while the air stays roughly the same, so fuel flow is close to proportional to indicated power and the points lie on a nearly straight line. Extend that line back to zero fuel: it cuts the brake-power axis at minus the friction power. A petrol engine is throttled, so pumping loss changes with load and the line bends; extrapolating a curve is unreliable. Even for a diesel the line curves slightly, so the result is an estimate.
How does a Morse test give the indicated power of each cylinder?
It is used on a multi-cylinder petrol engine at constant speed. Measure brake power with all cylinders firing, then cut the spark to one cylinder, reduce the dynamometer load until the speed returns, and read the brake power again. The friction of the dead cylinder is still there, so the drop in brake power equals that cylinder's indicated power. Repeat for each cylinder, add the indicated powers, and subtract the full brake power to get friction power. A cylinder with a much smaller drop has a fault such as a weak spark or a leaking valve.
What are the motoring test and the retardation test?
In a motoring test the fuel is cut and an electric dynamometer drives the engine at the test speed; the power it absorbs approximates friction plus pumping power, though slightly high because a cold, unfired cylinder has different pressures and oil temperature. In a retardation test the engine runs at a speed, the fuel is cut, and the time to slow through a speed band is noted, first with no load and then with a known load torque. Since inertia times deceleration equals torque, the friction torque is Tf = TL t2/(t1 − t2): no inertia needs to be known.
What do the performance curves of an engine look like?
At full throttle against speed, torque rises to a peak at middle speed (best breathing) and then falls as volumetric efficiency and friction worsen; brake power keeps rising past the torque peak and then flattens; BSFC is lowest near the torque peak and rises at both ends. At constant speed against load, brake thermal efficiency climbs from zero at no load and flattens near full load, while BSFC falls and then rises slightly near maximum load where a diesel starts to smoke. These shapes are typical, not universal: they depend on the engine.
In a Morse test, cylinder 3 is cut and the brake power drops by only half as much as for the other cylinders. The most likely conclusion is
The drop in brake power when a cylinder is cut equals that cylinder's indicated power, because its friction remains. A drop half the size means half the indicated power: look for a weak spark, poor compression or a clogged injector on that cylinder.
Worked examples
Morse test on a four-cylinder petrol engine · 3,000 rpm held constant. Brake torque with all cylinders firing 98 N·m; with cylinders 1 to 4 cut in turn: 70.5, 71.2, 69.8 and 70.9 N·m (illustrative)
- BP = 2π × 3,000 × T/60,000 = 0.31416 T kW; all firing: 30.788 kW
- With a cylinder cut: 22.148, 22.368, 21.928, 22.274 kW
- IP of each cylinder = BP − BP(cut): 8.639, 8.419, 8.859, 8.514 kW
- IP = 34.432 kW; FP = 34.432 − 30.788 = 3.644 kW; ηm = 30.788/34.432 = 89.4%
Answer: IP 34.43 kW, FP 3.64 kW, mechanical efficiency 89.4%
Willans line from five test points · Diesel engine at 1,500 rpm. Brake power 5, 10, 15, 20, 25 kW with fuel flow 2.05, 3.10, 4.18, 5.21, 6.32 kg/h (illustrative readings)
- Means: BP 15 kW, fuel 4.172 kg/h
- Least-squares slope = Σ(x − x̄)(y − ȳ)/Σ(x − x̄)² = 53.25/250 = 0.2130 kg/h per kW
- Intercept = 4.172 − 0.2130 × 15 = 0.977 kg/h (fuel needed just to overcome friction)
- Zero fuel at BP = −0.977/0.2130 = −4.59 kW, so FP ≈ 4.59 kW
- At 20 kW: ηm = 20/(20 + 4.59) = 81.3%
Answer: FP ≈ 4.59 kW; ηm 81.3% at 20 kW
Friction power from a retardation test · Fuel cut at 1,550 rpm; the engine slows from 1,550 to 1,450 rpm in 2.1 s with no load and in 0.9 s with a load torque of 36 N·m (illustrative)
- No load: I Δω = Tf t1; with load: I Δω = (Tf + TL) t2
- Tf = TL t2/(t1 − t2) = 36 × 0.9/(2.1 − 0.9) = 27.0 N·m
- Check: Δω = 100 × 2π/60 = 10.472 rad/s; I = 27 × 2.1/10.472 = 5.41 kg m², and (27 + 36) × 0.9/10.472 gives the same
- FP at the mean 1,500 rpm = 2π × 1,500 × 27/60,000 = 4.24 kW
Answer: Friction torque 27 N·m, friction power 4.24 kW at 1,500 rpm
Reciprocating air compressor: work, clearance, volumetric efficiency and free air delivery
Which syllabus covers thisAU not in syllabusVTU BME401 Module 5SPPU 202048 Unit VIMU not in syllabusKTU not in syllabus
Where is compressed air used, and how does a single-stage reciprocating compressor work?
Compressed air drives pneumatic tools, paint guns, rock drills, air brakes on trucks and trains, process controls and the starting of large diesels. A reciprocating compressor is a piston in a cylinder with spring-loaded valves that open on pressure difference. On the outward stroke the suction valve opens and air enters at about atmospheric pressure; on the return stroke both valves stay shut while the air is compressed, then the delivery valve opens and the air is pushed into the receiver at the delivery pressure. Reciprocating machines suit high pressures and modest flows. This chapter takes air as an ideal gas with R 0.287 kJ/kg K and γ 1.4.
Why is isothermal compression the ideal, and how much work do the three processes need?
Work per cycle is the area of the p-V diagram between the curve and the pressure axis. Compression heats the air, raising pressure faster, so the steeper the curve the bigger the area. Isothermal compression (pV constant, heat removed as fast as it is made) needs least work; isentropic (pV^1.4, no heat removed) needs most; real compressors with cooling fins or water jackets sit between, pV^n with n about 1.2 to 1.35. For 3 m³/min from 1 to 8 bar: isothermal 10.4 kW, n = 1.25 12.9 kW, isentropic 14.2 kW.
What does clearance do, and what are volumetric efficiency and free air delivery?
Clearance is the small volume left when the piston reaches the end of its stroke, needed for valves and safety. The air trapped there re-expands on the next suction stroke, and fresh air enters only after its pressure falls to p1, so the effective suction volume is less than the swept volume. Volumetric efficiency ηv = 1 + c − c (p2/p1)^(1/n), with clearance ratio c = Vc/Vs. It falls as the pressure ratio rises and reaches zero at ((1 + c)/c)^n, 42 for c = 0.06 and n = 1.3. Free air delivery is the delivered air expressed as volume at reference inlet conditions; ISO 1217 suggests 1 bar and 20 °C.
How does a real indicator diagram differ, and what are isothermal and mechanical efficiency?
Valves need a pressure difference to open and the air must push through them, so the real suction line sits below p1 and the delivery line above p2, often with a spike as each valve unseats, and the diagram's area grows. Isothermal efficiency is the isothermal work for the same air divided by the actual indicated work; mechanical efficiency is indicated power divided by shaft power. Output is matched to demand by capacity control: start-stop of the motor, unloading by holding the suction valve open, clearance pockets that add clearance volume, or speed control.
A compressor with 6% clearance is asked to deliver at higher and higher pressure. Its free air delivery will
The clearance air re-expands over more of the suction stroke as p2/p1 rises, so ηv = 1 + c − c (p2/p1)^(1/n) falls. With c = 0.06 and n = 1.3 it is 70.7% at 10 bar from 1 bar and reaches zero at a ratio of 41.8: the piston just compresses and re-expands the same air.
Worked examples
Power for isothermal, polytropic and isentropic compression · 3 m³/min of air at 1 bar and 27 °C compressed to 8 bar, no clearance (illustrative)
- p1 V̇1 = 100 kPa × 3/60 m³/s = 5 kW
- Isothermal: 5 × ln 8 = 10.397 kW
- n = 1.25: (1.25/0.25) × 5 × (8^0.2 − 1) = 25 × 0.5157 = 12.893 kW; delivery T = 300.15 × 8^0.2 = 454.9 K
- Isentropic: 3.5 × 5 × (8^0.2857 − 1) = 17.5 × 0.8114 = 14.200 kW; delivery T = 543.7 K
- Isothermal efficiency at n = 1.25: 10.397/12.893 = 80.6%
Answer: Isothermal 10.40 kW, polytropic 12.89 kW, isentropic 14.20 kW
Volumetric efficiency, FAD and power with clearance · Single-acting, bore 110 mm, stroke 130 mm, clearance ratio 0.05, 800 rpm, suction 0.97 bar and 32 °C, delivery 7.5 bar, n = 1.28 for compression and re-expansion; FAD at 1 bar, 20 °C (illustrative)
- Vs = π/4 × 0.11² × 0.13 = 1.2354 litre; p2/p1 = 7.5/0.97 = 7.732
- ηv = 1 + 0.05 − 0.05 × 7.732^(1/1.28) = 1.05 − 0.05 × 4.943 = 0.8029
- Effective suction volume = 0.8029 × 1.2354 = 0.9919 litre per cycle
- Work per cycle = (1.28/0.28) × 97 × 0.9919 × 10⁻³ × (7.732^(0.28/1.28) − 1) = 248.2 J; power = 0.24818 × 800/60 = 3.31 kW
- FAD = 0.9919 litre × 800 × (0.97/1) × (293.15/305.15) = 0.739 m³/min
- Delivery T = 305.15 × 7.732^(0.28/1.28) = 477.3 K (204 °C); isothermal efficiency = ln 7.732 × (1.28 − 1)/1.28 ÷ (7.732^(0.28/1.28) − 1) = 79.3%
Answer: ηv 80.3%, FAD 0.739 m³/min, indicated power 3.31 kW, delivery 204 °C, isothermal efficiency 79.3%
How clearance limits the delivery pressure · n = 1.3, suction 1 bar; clearance ratio 0.06, and for comparison 0.03 (illustrative)
- ηv = 0 when 1 + c = c r^(1/n), so r_max = ((1 + c)/c)^n = (1.06/0.06)^1.3 = 41.8
- At 10 bar with c = 0.06: ηv = 1.06 − 0.06 × 10^(1/1.3) = 1.06 − 0.06 × 5.878 = 0.7073
- With c = 0.03: ηv = 1.03 − 0.03 × 5.878 = 0.8537
Answer: Limit 41.8 bar for c = 0.06; at 10 bar ηv 70.7% (c = 0.06) against 85.4% (c = 0.03)
Multistage compression: optimum intermediate pressure, intercooling and rotary compressors
Which syllabus covers thisAU not in syllabusVTU BME401 Module 5SPPU 202048 Unit VIMU not in syllabusKTU not in syllabus
Why compress in several stages instead of one?
Three reasons. Delivery temperature: one stage from 1 to 25 bar with n = 1.3 heats air from 30 to 364 °C, too hot for lubricating oil and valves. Volumetric efficiency: clearance air re-expands over more of the stroke as the pressure ratio rises, so a single stage delivers less and less. Work: cooling the air between stages at constant pressure brings each stage back near the isothermal, and the area saved on the p-v diagram is real energy, 18.4% for two stages in that example. Stages also let the later cylinders be smaller and stronger.
What is perfect intercooling, and what intermediate pressure needs the least work?
Perfect intercooling cools the air back to the suction temperature T1 at the intermediate pressure, so every stage starts on the isothermal through state 1. Total work is then least when every stage has the same pressure ratio: for two stages p2 = √(p1 p3), for N stages each ratio is (p_final/p1)^(1/N). At this optimum each stage does equal work and delivers at the same temperature. As the number of stages grows the stepped path hugs the isothermal and the work approaches p1 V1 ln(p_final/p1).
What happens with imperfect intercooling, and what does an aftercooler do?
Real intercoolers leave the air a few degrees above suction temperature, limited by cooling-water temperature and cooler size. The next stage then starts to the right of the isothermal and needs more work: cooling only to 45 °C instead of 30 °C costs about 2.5% in the two-stage example. The true optimum then makes every stage deliver at the same temperature, which moves the intermediate pressure up slightly, but the saving is tiny. An aftercooler cools the delivered air before the receiver, so moisture condenses and is drained before it reaches tools and pipes.
How do Roots, vane, screw and scroll compressors differ from a reciprocating one?
A Roots blower has two lobed rotors that carry pockets of air round without squeezing them; the pressure rises only when a pocket opens to the delivery side and high-pressure air flows back into it, so its work is Δp × V, worse than isentropic as the ratio grows (80.0% efficiency at a pressure ratio of 1.8 in the example below). A vane compressor's eccentric rotor shrinks each cell before it opens, giving some internal compression and less back-flow loss (95.9%). Screw and scroll machines compress internally and smoothly with few valves and suit continuous duty: screws in workshops, scrolls in many air conditioners. Centrifugal compressors handle very large flows at modest pressure ratio per stage.
A two-stage compressor with perfect intercooling takes air from 1 bar to 16 bar. The intermediate pressure for minimum work is
With perfect intercooling the total work is least when both stages have the same pressure ratio: √(1 × 16) = 4 bar, a ratio of 4 in each stage. Each stage then does the same work and delivers at the same temperature.
Worked examples
Two stages against one · 0.05 kg/s of air from 1 bar and 30 °C to 25 bar, n = 1.3 in every stage, perfect intercooling (illustrative)
- Intermediate pressure = √(1 × 25) = 5 bar (golden-section minimisation of the total work gives the same)
- One stage: w = (1.3/0.3) × 0.287 × 303.15 × (25^(0.3/1.3) − 1) = 415.4 kJ/kg; delivery 364 °C
- Two stages: w = 2 × (1.3/0.3) × 0.287 × 303.15 × (5^(0.3/1.3) − 1) = 339.1 kJ/kg; each stage delivers at 166 °C
- Saving = 1 − 339.1/415.4 = 18.4%; isothermal limit 0.287 × 303.15 × ln 25 = 280.1 kJ/kg
- Power: one stage 20.77 kW, two stages 16.96 kW
Answer: 5 bar intermediate; 16.96 kW against 20.77 kW, an 18.4% saving; delivery 166 °C instead of 364 °C
Imperfect intercooling · Same compressor, but the intercooler returns the air at 45 °C instead of 30 °C; intermediate pressure kept at 5 bar
- Stage 1 unchanged: 169.6 kJ/kg
- Stage 2 from 318.15 K: (1.3/0.3) × 0.287 × 318.15 × (5^(0.3/1.3) − 1) = 178.0 kJ/kg; total 347.5 kJ/kg
- Extra work = 347.5/339.1 − 1 = 2.47%
- True optimum (equal delivery temperatures): p2 = 5 × (318.15/303.15)^(1.3/0.6) = 5.55 bar, total 347.2 kJ/kg: only 0.33 kJ/kg less
Answer: 347.5 kJ/kg, 2.5% more than perfect intercooling; re-optimising to 5.55 bar saves under 0.1%
Roots blower against a vane compressor · 8 m³/min of air at 1 bar raised to 1.8 bar (γ 1.4). The vane machine compresses internally to 1.4 bar before its cells open (illustrative)
- Isentropic ideal: 3.5 × 100 × (8/60) × (1.8^0.2857 − 1) = 8.534 kW
- Roots (no internal compression): (1.8 − 1) × 100 × 8/60 = 10.667 kW; efficiency 8.534/10.667 = 80.0%
- Vane: isentropic 1 → 1.4 bar, then the cell volume 6.291 m³/min is filled back from 1.4 to 1.8 bar: 3.5 × 100 × (8/60) × (1.4^0.2857 − 1) + 0.4 × 100 × 6.291/60 = 8.903 kW
- Vane efficiency 8.534/8.903 = 95.9%
Answer: Roots 10.67 kW (80.0%), vane 8.90 kW (95.9%), isentropic 8.53 kW
Refrigeration: reversed Carnot, vapour compression, refrigerants and vapour absorption
Which syllabus covers thisAU not in syllabusVTU BME401 Module 4SPPU 202048 Unit IMU not in syllabusKTU not in syllabus
What is the reversed Carnot cycle, and what is a tonne of refrigeration?
Run a Carnot engine backwards and it pumps heat from a cold space at TL to surroundings at TH, using work. Its COP, heat removed per unit work, is TL/(TH − TL) with temperatures in kelvin: 5.26 between −10 °C and 40 °C. No real refrigerator between those temperatures can beat it. Used as a heat pump, the useful output is the heat rejected, so COP_HP = COP_R + 1. Capacity is quoted in tonnes of refrigeration: the cooling rate that freezes one short ton (907 kg) of water at 0 °C in 24 hours. Syllabi take 1 TR = 211 kJ/min = 3.5167 kW.
How does the vapour compression cycle work on the p-h chart?
Four steps. 1-2: the compressor raises saturated or slightly superheated vapour to the condenser pressure; it leaves superheated. 2-3: the condenser rejects heat at constant pressure until the refrigerant is liquid. 3-4: the expansion valve throttles it at constant enthalpy into a cold, wet mixture. 4-1: the evaporator boils it at constant pressure, absorbing heat. On the p-h chart every quantity is a horizontal length: refrigerating effect h1 − h4, compressor work h2 − h1. For R-134a between −10 °C and 40 °C that is 136.3 and 33.8 kJ/kg, a COP of 4.03 against the Carnot 5.26.
How do evaporator and condenser temperature, subcooling and superheating change the COP?
A lower evaporator or a higher condenser temperature widens the lift, so the work per kg rises, the refrigerating effect falls and the COP drops: keep the evaporator as warm and the condenser as cool as the job allows. Subcooling the liquid moves state 3 left, so more of each kilogram can boil: 5 K of subcooling raises the R-134a refrigerating effect in Example 2 by 5.4% at the same work. Superheat at the evaporator exit protects the compressor from liquid; it is useful cooling only if it happens inside the cooled space, and it raises the discharge temperature.
Which refrigerants are used, and why did R-12 and now R-134a have to go?
A good refrigerant has a large latent heat, moderate pressures at the working temperatures, is stable, safe and cheap, and does no harm in the atmosphere. R-12, a CFC with ozone depletion potential 1.0 and a 100-year GWP of 12,500 (IPCC AR6), was phased out under the Montreal Protocol. Its replacement R-134a does not harm the ozone layer but has a GWP of 1,530, so HFCs are now being phased down. The alternatives: R-32 (GWP 771, mildly flammable), R-1234yf (GWP below 1), propane R-290 and isobutane R-600a (single-digit GWP, flammable) and ammonia R-717 (0, toxic, ideal for large plants).
How does a vapour absorption system work without a compressor?
The compressor is replaced by a 'thermal compressor'. Low-pressure vapour from the evaporator is absorbed into a liquid, the solution is pumped to high pressure (pumping a liquid needs little work), and heat in the generator drives the refrigerant back out. Ammonia-water plants use ammonia as refrigerant and need a rectifier to strip water vapour; water-lithium bromide chillers use water as refrigerant, so they cool only above 0 °C. Even ideally, heat at 110 °C with 35 °C surroundings and a 5 °C evaporator gives a COP of only 1.81; real single-effect units typically reach 0.6-0.8. They win where waste heat or steam is cheap.
A refrigerator's evaporator stays at −10 °C. On a hot day its condenser temperature rises from 35 °C to 45 °C. The COP
COP depends on the lift between the two temperatures. Even the reversed Carnot limit falls from 5.85 to 4.78, 18% lower; a real vapour compression cycle loses more, because its throttling loss also grows with the lift. Move the condenser slider in the interactive to see it.
Worked examples
Reversed Carnot limit for a cold store · Cold store held at −18 °C, heat rejected at 35 °C, load 3 TR (illustrative); 1 TR = 3.5167 kW
- COP_R = TL/(TH − TL) = 255.15/(308.15 − 255.15) = 4.814
- Heat removed Q = 3 × 3.5167 = 10.55 kW
- Minimum power W = Q/COP = 10.55/4.814 = 2.191 kW
- Heat rejected = Q + W = 12.74 kW; as a heat pump between the same temperatures COP_HP = 5.814
Answer: No machine can do it with less than 2.19 kW; COP_R = 4.81, COP_HP = 5.81
Simple vapour compression cycle with R-134a · R-134a, evaporator −10 °C, condenser 40 °C, saturated vapour into the compressor, saturated liquid out of the condenser, isentropic compression, capacity 1.5 TR (illustrative). NIST data (IIR reference): at −10 °C hf 186.70, hg 392.67 kJ/kg, sg 1.7333 kJ/kg K, p 0.2006 MPa; at 40 °C hf 256.41 kJ/kg, p 1.0166 MPa
- State 1: h1 = 392.67 kJ/kg, s1 = 1.7333 kJ/kg K; state 3 = 4: h3 = h4 = 256.41 kJ/kg
- State 2: on the 1.0166 MPa isobar, s = 1.7333 lies between 46 °C (s 1.73235, h 426.16) and 47 °C (s 1.73580, h 427.26): T2 = 46.3 °C, h2 = 426.48 kJ/kg
- RE = h1 − h4 = 136.26 kJ/kg; w = h2 − h1 = 33.82 kJ/kg; COP = 136.26/33.82 = 4.03
- ṁ = 1.5 × 3.5167/136.26 = 0.0387 kg/s; compressor power = 0.0387 × 33.82 = 1.31 kW
- Throttle exit dryness x4 = (256.41 − 186.70)/(392.67 − 186.70) = 0.338; pressure ratio 1.0166/0.2006 = 5.07; Carnot COP = 263.15/50 = 5.26
Answer: COP 4.03, 0.0387 kg/s of R-134a, 1.31 kW, discharge 46.3 °C; the Carnot limit is 5.26
Ammonia plant with superheat, subcooling and a real compressor · R-717, evaporator −20 °C (0.1900 MPa), condenser 35 °C (1.3500 MPa), 5 K superheat at the evaporator exit, 5 K subcooling, compressor isentropic efficiency 0.80, 10 TR (illustrative). NIST data (IIR): vapour at −15 °C on the evaporator isobar h 1,449.45 kJ/kg, s 5.9501 kJ/kg K; saturated liquid at 30 °C h 341.57 kJ/kg
- h1 = 1,449.45 kJ/kg; on the 1.3500 MPa isobar s = 5.9501 lies between 130 °C (h 1,748.31) and 131 °C (h 1,750.82): T2s = 130.3 °C, h2s = 1,748.96 kJ/kg
- h2 = h1 + (h2s − h1)/η = 1,449.45 + 299.51/0.80 = 1,823.84 kJ/kg, between the 160 °C and 161 °C rows: discharge at 160.2 °C
- h4 = h3 = 341.57 kJ/kg (liquid at 30 °C, x4 = 0.175); RE = 1,449.45 − 341.57 = 1,107.88 kJ/kg; w = 374.39 kJ/kg; COP = 2.96
- ṁ = 10 × 3.5167/1,107.88 = 0.0317 kg/s; power = 11.88 kW; Carnot COP = 253.15/55 = 4.60
Answer: COP 2.96, only 0.0317 kg/s of ammonia for 10 TR, 11.9 kW, discharge 160 °C: ammonia's refrigerating effect per kg is 8.1 times R-134a's, but its discharge runs hot
Psychrometry and air-conditioning processes: the psychrometric chart, cooling, humidifying and mixing
Which syllabus covers thisAU not in syllabusVTU BME401 Module 4SPPU 202048 Unit IMU not in syllabusKTU not in syllabus
What do dry-bulb, wet-bulb, dew point, specific humidity and relative humidity measure?
Moist air is dry air plus water vapour, both treated as ideal gases at 101.325 kPa. Dry-bulb is the ordinary temperature. Specific humidity ω is kg of vapour per kg of dry air. Relative humidity is the vapour pressure over the saturation pressure at the same temperature; degree of saturation is ω over the saturated ω. Dew point is where the vapour would start to condense on cooling. Wet-bulb is the temperature a wetted thermometer settles at as evaporation cools it. Air at 34 °C and 55% holds 18.5 g/kg, with a dew point of 23.7 °C and a wet-bulb of 26.3 °C.
How do you read the psychrometric chart?
Dry-bulb runs along the bottom, specific humidity up the right side. The curved top edge is saturation (100% RH); the curves below it are lower relative humidities. Lines sloping down to the right are constant enthalpy, almost the same as constant wet-bulb. Any two properties fix a point and the chart gives the rest: go straight left to the saturation curve for the dew point, follow the sloping line up to it for the wet-bulb. Processes become lines: horizontal for sensible heating and cooling, along the wet-bulb line for evaporative cooling, straight lines for mixing.
What happens in a cooling coil, and what are the bypass factor and apparatus dew point?
Sensible heating or cooling changes only the dry-bulb, so ω stays fixed and the point moves horizontally; heating 34 °C, 55% air by 10 K takes 10.4 kJ per kg of dry air. A cooling coil whose surface is below the air's dew point also condenses water. Model it as if a fraction BF of the air bypasses the coil untouched while the rest leaves saturated at the coil surface temperature, the apparatus dew point (ADP). The leaving state then lies on the straight line from the inlet to the ADP, a fraction BF of the way back from the ADP. A smaller BF means a deeper coil.
How do humidifying, evaporative cooling and mixing show on the chart?
Heating with humidification (steam or spray) moves the point up and to the right, as winter comfort needs. An evaporative cooler sprays recirculated water into dry air: the water's evaporation takes heat from the air, so the dry-bulb falls and ω rises along a constant wet-bulb line, ending at the wet-bulb temperature at best. It works well in dry heat (40 °C, 20% air reaches 24.7 °C in an 85% effective cooler) but not in humid air. Adiabatic mixing of two streams conserves dry air, water and energy, so the mixed point lies on the straight line between them, closer to the larger stream.
What does a summer air-conditioning system do to the air?
Hot humid outdoor air is mixed with return air from the room, then passed over a cooling coil whose surface is below the dew point, so it is cooled and dehumidified together. The coil leaves the air nearly saturated and cooler than the room needs, so it absorbs both the room's sensible heat (people, lights, sunshine) and its latent heat (moisture from people and cooking) as it warms back up. If the leaving air is too cold or the coil removes too much water, a reheater trims the supply temperature. A 1.5 TR coil handling 34 °C, 55% air with ADP 11 °C treats about 0.125 kg/s of dry air.
What does a winter air-conditioning system do to the air?
Cold outdoor air holds very little water, so once it is heated to room temperature its relative humidity falls far below comfort, drying skin and throats. Winter air conditioning therefore heats and humidifies: a preheating coil, then a humidifier (steam injection, or a water spray that also cools the air a little), then a reheating coil to reach the supply temperature. On the chart the path goes right (heating), up along a near wet-bulb line or steeply up (humidification), and right again. The supply state is chosen so the air absorbs the room's heat loss and moisture balance.
Hot, dry air passes through an evaporative cooler (a wetted pad). Which property of the air stays nearly constant?
The heat to evaporate the water comes from the air itself, so the air's enthalpy stays almost constant and the process follows a constant wet-bulb line: 40 °C, 20% air keeps a wet-bulb of 22.0 °C while its dry-bulb falls to 24.7 °C and its specific humidity rises from 9.2 to 15.6 g/kg.
Worked examples
Properties of humid summer air · Air at 34 °C dry-bulb, 55% RH, 101.325 kPa (illustrative); saturation pressure from IAPWS-IF97
- psat(34 °C) = 5.325 kPa, so pv = 0.55 × 5.325 = 2.929 kPa
- ω = 0.622 × 2.929/(101.325 − 2.929) = 0.01851 kg/kg = 18.51 g/kg
- h = 1.005 × 34 + 0.01851 × (2501 + 1.88 × 34) = 81.65 kJ/kg dry air
- Dew point: the temperature whose psat is 2.929 kPa = 23.68 °C; degree of saturation = 0.01851/0.03450 = 0.537
- Wet-bulb: solve h1 + (ωs − ω1) × 4.186 tw = hs(tw) by bisection: tw = 26.32 °C
Answer: ω 18.51 g/kg, h 81.7 kJ/kg, dew point 23.7 °C, wet-bulb 26.3 °C
Cooling and dehumidifying coil · The 34 °C, 55% air of Example 1 (ω 18.51 g/kg, h 81.65 kJ/kg) over a coil with ADP 11 °C and bypass factor 0.15; per kg/s of dry air; condensate leaves at 11 °C
- Saturated air at the ADP: ωA = 8.17 g/kg, hA = 31.65 kJ/kg
- Leaving ω2 = 0.15 × 18.51 + 0.85 × 8.17 = 9.72 g/kg; h2 = 0.15 × 81.65 + 0.85 × 31.65 = 39.15 kJ/kg
- t2 = (h2 − 2501 ω2)/(1.005 + 1.88 ω2) = 14.51 °C (the shortcut ADP + BF(t1 − ADP) gives 14.45 °C), RH2 = 94.3%
- Water removed = 8.79 g/kg; coil load = h1 − h2 − (ω1 − ω2) × 4.186 × 11 = 42.10 kW per kg/s
- A 1.5 TR (5.275 kW) coil could treat 5.275/42.10 = 0.1253 kg/s of this air
Answer: Air leaves at 14.5 °C and 94% RH; the coil removes 42.1 kW and 8.79 g of water per kg/s of dry air
Mixing return air with fresh air · Return air 25 °C, 50% RH at 2.4 kg/s dry air mixed adiabatically with fresh air at 34 °C, 55% RH (ω 18.51 g/kg, h 81.65 kJ/kg) at 0.6 kg/s (illustrative)
- Return air: ω = 9.88 g/kg, h = 50.31 kJ/kg
- Water balance: ω3 = (2.4 × 9.88 + 0.6 × 18.51)/3.0 = 11.61 g/kg
- Energy balance: h3 = (2.4 × 50.31 + 0.6 × 81.65)/3.0 = 56.58 kJ/kg
- t3 = (h3 − 2501 ω3)/(1.005 + 1.88 ω3) = 26.82 °C (the dry-air-weighted average is 26.80 °C); RH3 = 52.6%
Answer: Mixed air at 26.82 °C, 11.61 g/kg, 53% RH, on the straight line between the two states, 20% of the way from the return air
Evaporative cooler on a dry afternoon · Air at 40 °C, 20% RH (illustrative dry heat), 2 kg/s of dry air through a cooler of effectiveness 0.85
- Inlet: ω = 9.20 g/kg, h = 63.90 kJ/kg, wet-bulb 22.03 °C
- t2 = 40 − 0.85 × (40 − 22.03) = 24.72 °C
- Adiabatic saturation line: h2 = h1 + (ω2 − ω1) × 4.186 × 22.03, so ω2 = 15.56 g/kg, RH2 = 79.3%
- Water evaporated = 2 × (15.56 − 9.20) g/s = 45.8 kg/h
Answer: Air leaves at 24.7 °C and 79% RH, using 46 kg of water an hour; the wet-bulb stays at 22.0 °C
Keep going
- Otto, Diesel and dual cycle calculator
- Rankine cycle calculator (IAPWS-IF97 steam)
- Adiabatic flame temperature calculator
- IC Engine Analyst course (Python and Cantera)
- HVAC Systems Flow Analysis course
- GATE Mechanical thermodynamics questions
- Automobile Engineering interactive book
- Heat and Mass Transfer interactive book
- Fluid Mechanics interactive book
- All Skill-Lync interactive books
Recommended reading
- Thermal Engineering, M. M. Rathore
- Internal Combustion Engines, V. Ganesan
- A Course in Thermal Engineering, S. Domkundwar, C. P. Kothandaraman, A. Domkundwar
- Basic and Applied Thermodynamics, P. K. Nag
- Thermodynamics: An Engineering Approach, Y. A. Cengel, M. A. Boles
- Refrigeration and Air Conditioning, C. P. Arora
- Internal Combustion Engine Fundamentals, J. B. Heywood
How this book was made
Chapters follow the official syllabi listed above. Every interactive's formulas and every worked-example number were checked by script. Explanations, animations and examples are original to Skill-Lync. Topics informed by MIT OpenCourseWare 2.005 (Thermal-Fluids Engineering I), CC BY-NC-SA. All explanations, animations and examples are original to Skill-Lync; MIT does not endorse this page.