Section modulus calculator for any cross-section

Get the elastic section modulus S (to the top and bottom fibres), the plastic section modulus Z, the second moment of area, centroid, principal axes and bending stress of an I-beam, T, channel, angle, box, tube or round bar, or of any shape you type in as x, y coordinates, holes included. A thin-wall mode handles sheet-metal sections such as the car hood of Skill-Lync's section modulus challenge, and "Check my numbers" tests the I and y in a hood report. Free, no sign-up, runs in your browser.

Checked against textbook formulas and grid integration (38 checks) · Updated 20 Nov 2026

Sharp corners, no root radii, so a rolled section's handbook values come out 1 to 3% different. x is horizontal, bending about the x-axis is the usual vertical load.

Sₓ elastic (min)5,91,395 mm³I/c with c = 150 mm
Zₓ plastic6,70,752 mm³shape factor 1.134
σ max = M/Sₓ84.5 MPaat M = 50 kN·m
I-beam 150 × 300 mm with its centroid and neutral axis
sectionelastic neutral axisplastic neutral axiscentroid
Area5,808mm²
Centroid x̄75mm
Centroid ȳ150mm
Iₓ (about the centroid)8.871 × 10⁷mm⁴
I_y67,61,776mm⁴
Iₓᵧ (product)0mm⁴
Sₓ to the top fibre5,91,395mm³
Sₓ to the bottom fibre5,91,395mm³
Zₓ plastic6,70,752mm³
S_y (smaller side)90,157mm³
Z_y plastic1,39,416mm³
I₁, I₂ principal8.871 × 10⁷ / 67,61,776mm⁴
rₓ, r_y radius of gyration123.6 / 34.12mm

Principal axis 1 at 0.0° from x. Plastic neutral axis at y = 150 mm.

What is section modulus?

Section modulus S is the property of a beam's cross-section that sets its bending stress: the largest stress is the bending moment divided by S. It equals the second moment of area I about the neutral axis divided by c, the distance from that axis to the farthest fibre, and has units of length cubed (mm³ or m³).

Two sections with the same I can have different S: a deep, thin one has a large c. And one section has two values when the centroid is off-centre, one to the top fibre and one to the bottom. Design uses the smaller, because that fibre yields first. Steel codes call it S (AISC 360) or Wel (Eurocode 3).

Section modulus formulas for common shapes

For bending about the horizontal axis through the centroid, sharp corners:

SectionElastic SPlastic ZShape factor Z/S
Rectangle b × h1.5
Solid circle, diameter d1.698
Tube, outer D, inner d1.38 (50 × 4 mm)
Box B × H, inside b × h1.27 (100 × 200 × 10)
I-beam, flanges b × t_f, web t_w, depth h1.13 (150 × 300)

Worked example: an I-beam 150 mm wide and 300 mm deep with 12 mm flanges and an 8 mm web. I = [150 × 300³ − 142 × 276³]/12 = 8.871 × 10⁷ mm⁴, c = 150 mm, so S = 5,91,395 mm³. Under M = 50 kN·m the outer fibres see 50 × 10⁶ / 5,91,395 = 84.5 MPa. That is the calculator's opening case.

What is the difference between elastic and plastic section modulus?

Elastic S tells you when the first fibre yields. Keep loading a ductile beam and the yielded zone spreads inwards until the whole section is at the yield stress, half in tension and half in compression. The axis that splits the area in two equal halves is the plastic neutral axis, and the plastic section modulus Z is the first moment of the two halves about it:

For the I-beam above Z = 6,70,752 mm³ and the shape factor is 1.134: most of its area is already in the flanges, far from the axis, so there is little left to gain after first yield. A rectangle gains 50%. Plastic Z is what Eurocode 3 (Wpl) and AISC 360 use for the bending resistance of compact steel sections; elastic S is the limit for slender sections and for parts that must not yield at all.

When the section is not symmetric the two neutral axes part company. In a 120 × 150 mm T-section (15 mm flange, 10 mm web) the centroid is 110.4 mm above the web tip, but the plastic neutral axis is up in the flange at 136.88 mm, because the web alone holds less than half the area. S is 1,62,030 mm³ to the flange and 58,205 mm³ to the web tip; Z = 1,04,203 mm³.

How do you calculate the section modulus of an irregular shape?

Trace the outline as a polygon of points (xi, yi), in order. The shoelace formulas, which come from Green's theorem, give the area and the second moment about the x-axis exactly for any polygon, convex or not:

The centroid comes the same way from the first moments. A hole is a loop traced the other way round, so its area and inertia subtract. Then move the inertia to the centroid and, if the shape has no axis of symmetry, find the principal axes:

Finally S = I/c with c from the centroid to the farthest point. The "Any shape" tab does all of this, finds the plastic neutral axis by bisection on the area and clips the polygon there for Z. A curved edge is fine as many short segments: a circle drawn as 720 points (with the same area as the circle) matches πd⁴/64 to better than one part in a million. For an angle section with unequal legs, the product of inertia is not zero and the principal axes are tilted: a 100 × 75 × 10 mm angle has I1 = 20,01,578 and I2 = 4,26,064 mm⁴, with axis 1 at 61.2° from the long leg.

The hood section modulus challenge: what goes wrong

"Section Modulus calculation and optimization" is a challenge in Skill-Lync's automotive sheet metal design courses: take a cross-section through the hood you modelled in CATIA V5, find its section modulus, then change the design so the section modulus goes up. 1,896 public student reports carry that title. We read 40 of them on 20 Nov 2026.

Almost all follow the same steps: intersect the outer and inner panels with a plane, join the two curves at the ends, fill the closed profile, run CATIA's Measure Inertia, take the smaller principal moment as I, and divide it by y. In 31 of the 40 reports, y is half the section's length (or the whole of it): values from 238 to 903 mm, for sections that are a few tens of millimetres deep.

That pairs the wrong two numbers. The smaller principal moment belongs to bending across the thin direction of the section, the way a hood bends when you press on it, so its extreme fibre is the farthest point from the centroid across the thickness. Half the length is the extreme fibre for the other axis, the one that goes with the larger moment. To see how large the error is we drew an illustrative section 880 mm long and 45 mm deep (crowned outer skin, flat inner panel):

The hood section filled in, as a closed CATIA profile: centroid, elastic neutral axis and extreme-fibre distancesvertical scale ×5.2
The section filled in, the way the reports measure it. Green: centroid and elastic neutral axis. Vertical scale exaggerated so the 45 mm depth is visible.
  • Filled profile, correct y: Imin = 48,34,047 mm⁴, centroid 20.6 mm above the inner panel, farthest fibre 24.4 mm away, S = 1,98,191 mm³.
  • Filled profile, y = L/2 = 440 mm: S = 10,986 mm³, 18.0 times too small.

The second problem is the fill itself. A filled profile treats the hood as a solid block 45 mm thick. A real hood is two steel sheets less than a millimetre thick with air between them, and only the sheets carry load. Draw the same section as sheets, a 0.7 mm skin and a 0.65 mm inner panel (two reports in our sample state 0.7 and 0.75 mm), and the numbers change:

The same hood section as two steel sheets, 0.7 mm outer skin and 0.65 mm inner panelvertical scale ×5.1
The same section as two sheets: 0.7 mm outer skin and 0.65 mm inner panel, joined at the hem. The sheet thickness is drawn to the same exaggerated vertical scale.
  • Sheets: A = 1,201 mm² of steel, I = 4,71,138 mm⁴ (10.3 times less than the filled profile), c = 24.0 mm, S = 19,615 mm³, plastic Z = 22,724 mm³.
  • Two errors in the reports pull in opposite directions (filled area up, y = L/2 down), so a report's final S can land in a plausible range by accident. Neither number on its own is the hood's section modulus.

In CATIA, Measure Inertia also gives the centre of gravity G and the directions of the principal axes. Measure the distance from G to the farthest point of the section along the direction perpendicular to the axis of the moment you use. To include sheet thickness, measure a thin surface strip of the real thickness per panel, or type the panel centre lines into the "Any shape" tab with "t = 0.7".

How do you increase the section modulus of a hood?

Depth beats thickness. A sheet's contribution to I grows with the square of its distance from the neutral axis but only linearly with its thickness. On the illustrative section, two-sheet model:

ChangeS (mm³)S changeSteel added
As drawn (0.7 + 0.65 mm, 45 mm deep)19,615––
Offset the inner panel 0.5 mm away (what most reports do)19,905+1.5%+0.0%
Inner panel 5 mm deeper22,533+14.9%+0.3%
Outer skin 0.7 → 0.8 mm21,870+11.5%+7.3%
Both sheets 0.1 mm thicker22,397+14.2%+14.8%

Moving the inner panel 5 mm deeper raises S by 14.9% for 0.3% more steel. Making both sheets 0.1 mm thicker raises it by about the same (14.2%) but adds 14.8% mass. In a real hood the depth is limited by the engine and pedestrian-protection clearance under the bonnet, which is why inner panels get beads, ribs and cut-outs rather than just more depth.

Which mistakes does "Check my numbers" catch?

  • y = half (or all) of the section length with Imin, the axis mix-up above, and the value you would get pairing the length with Imax instead.
  • m⁴ read as mm⁴. CATIA often shows inertia in m⁴, and 1.4 × 10⁻⁶ m⁴ is 1.4 × 10⁶ mm⁴. Reports in our sample write "1.4169e-06 mm^4".
  • Arithmetic slips, including a result off by an exact power of ten, and a y larger than the section's depth.
  • Given the depth h, the range the weak-axis S must fall in: between I/h and I/(h/2).

What this calculator does not cover

  • Local buckling of thin walls. Thin sheet in compression buckles before it yields, so steel and cold-formed codes use a reduced effective section (Eurocode 3 Part 1-3, AISI S100). S here is the full gross section.
  • Torsion and shear. No torsion constant J, warping constant or shear centre; S is for bending only.
  • Thin-wall joints. Each sheet is a chain of rectangles, so overlaps at corners count twice; fine while t is small next to the other dimensions.
  • A hood is not a beam. A section modulus compares cross-sections; the real stiffness of a hood also depends on its 3D curvature, the hem and mastic joints between the panels, and the hinges and latch. Check it with FEA.
  • Root radii. Rolled sections have fillets the "Standard shape" tab leaves out; use the handbook values (IS 808, EN 10365, AISC) for design.
Learn automotive sheet metal design

The hood section modulus challenge is part of Skill-Lync's automotive sheet metal design courses in CATIA V5, next to the hood, fender, roof and back-door projects.

Frequently asked questions

What is section modulus?

Section modulus S is a property of a beam's cross-section that links the bending moment to the largest bending stress: σ = M/S. It is the second moment of area I divided by c, the distance from the neutral axis to the farthest fibre. Units are length cubed (mm³). A bigger S means a lower stress for the same moment.

What is the formula for section modulus?

S = I/c. For a rectangle b × h bending about its long side, S = bh²/6; for a solid circle, S = πd³/32; for a tube, S = π(D⁴ − d⁴)/(32D). The plastic section modulus is Z = bh²/4 for a rectangle and d³/6 for a circle. For example a 150 × 300 mm I-beam with 12 mm flanges and an 8 mm web has S = 5,91,395 mm³ and Z = 6,70,752 mm³.

What is the difference between elastic and plastic section modulus?

Elastic S = I/c gives the moment at which the outermost fibre first yields, M_y = f_y·S. Plastic Z is the first moment of area of both halves about the equal-area axis and gives the moment when the whole section has yielded, M_p = f_y·Z. Z/S is the shape factor: 1.5 for a rectangle, 1.70 for a round bar and about 1.13 for an I-beam.

How do you calculate the section modulus of an irregular shape?

Describe the outline as a polygon of x, y points (holes as their own loops), compute area, centroid and second moment with the polygon (shoelace) formulas, move I to the centroid with the parallel axis theorem, and divide by the distance from the centroid to the farthest point. Paste the coordinates into this calculator and it does all of that, plus the plastic modulus.

Why is the section modulus different at the top and bottom of a T-section?

Because the centroid is not at mid-depth, so the top and bottom fibres are at different distances c. For a 120 × 150 mm tee (15 mm flange, 10 mm web), the centroid is 110.4 mm above the web tip: S = 1,62,030 mm³ to the flange and 58,205 mm³ to the web tip. Design uses the smaller one, because that fibre reaches yield first.

What value of y should I use for the hood section modulus?

The distance from the section's centroid to its farthest point, measured perpendicular to the axis whose moment of inertia you use. With CATIA's smaller principal moment (the hood bending under a vertical load), that is the distance across the thin direction, about 24.4 mm for a 45 mm deep section. Half the section's length (440 mm for an 880 mm section) goes with the larger principal moment instead. 31 of the 40 reports we read mixed the two.

Related on Skill-Lync

Sources

  • J. M. Gere, B. J. Goodno, Mechanics of Materials, 9th ed., Cengage, 2018: flexure formula, section modulus, plastic moment and shape factors.
  • W. C. Young, R. G. Budynas, A. M. Sadegh, Roark's Formulas for Stress and Strain, 8th ed., McGraw-Hill, 2012: properties of plane sections.
  • EN 1993-1-1 (Eurocode 3), elastic and plastic section moduli Wel, Wpl and section classes; EN 1993-1-3 for cold-formed thin-gauge members. ANSI/AISC 360-22 for S and Z.
  • Dassault Systèmes, CATIA V5 documentation, Measure Inertia: principal moments, axes and centre of gravity of a surface or profile.
  • Skill-Lync, sample of 40 public student reports titled "Section Modulus calculation and optimization", read 20 Nov 2026: the I, y and S each report used.
  • Skill-Lync, scripts/verify/section.py: 38 checks of the polygon formulas against closed forms (rectangle, box, circle, tube, I, T, unequal angle), against grid integration (a random polygon with a hole and the filled hood section), and of the thin-wall hood against a sum of rotated rectangles. This page recomputes its numbers with the browser code and checks them against that script at build time.
Free counselling

From a hood section to a BIW design career.

Sheet metal design, section properties and CATIA V5 surfacing are what automotive body teams test for. A Skill-Lync counsellor can map the course that fits the role you want.