Structural Modelling using Etabs 2018
Answer:
- Typical floor plan – The location and thickness of the brick walls and the use of the
space (for estimating live load) can be obtained from this plan - A building section through the staircase and lift core is provided
- Parking layout in the ground floor – the column/shear wall arrangement must not
obstruct entry/exit of vehicles.
STEP 1: Grid data

STEP 2: Storey data

Step 3: Material properties
COLUMNS
BEAMS
SLABS



SHEAR WALL

STEP 4: Changing Orientation and adjustment of shear walls and columns accordingly



STEP 5 : Adjustment of slab sections

STEP 6 : Providing support = Fixed support

View of sections


STEP 7: Defining Load Patterns

STEP 8: Assinging Loads Live load, Brick wall,Floor finish


STEP 9: Providing the Mass source

STEP 10: Defining Earthquake loads

Ta = (0.09*24)/squareroot of d = 4.5 seconds in both x and Y directions

STEP 11: Assigning Diaphragm

STEP 12: Giving PIER LABELS

STEP 13: Defining Response Spectrum Analysis


STEP 14:
Comparision of BASE REACTIONS using Equvivalent Lateral force method vs Modal Response Spectrum Analysis
Base shear for Eqx and Eq y is 3913.65KN
For MRSA to get Scale factor = 3913.65/24583 = 0.16
For MRSA to get Scale factor = 3913.65/680 = 5.75
Eqx,Eqy values should be approximately equal to RSx ,RSy


STEP 15 : Obtaining the same values for both as per step 14
This Analysis is RUN only after deleting the EQx and EQy.
Obtained approx values for RSx and RSy in comparision with EQx and EQy
STEP 16: Fundamental Time period of the modes is checked for the modes
No proper result for any type of load combinations for UX and UY
Using MRSA No proper result

Using EQ loads No proper result for UX and UY

Using Gravity loads No proper result for UX and UY


No proper result even after the analysis is obtained by using gravity loads (that is only DL,LL,Brick wall,Floor finish) + EQ loads in X and Y direction and the Beam at the opening between GRID B and C

other analysis is also done without Beam between GRID B and C
But still the value is same
also there is no proper modal participating mass ratios
In UX,UY direcctions in both the cases.

STEP 17: Check the BASE SHEAR for the EQx to make a way such that the total Lateral force in X direction is taken by the Shear walls is 75 to 80%
Here I got approx 61%
therefore the resizing of the model to be done for the Analyis of Building
That is the sizes of the Shear walls need to be increased.
SEE THE CALCULATION BELOW in calculator
Use Fx here


STEP 18: Check for Axial load Ratio for columns it should not be greater than 0.4
For columns
For Load combination 27 to 38 we have 0.9 DL
Therefore these load combinations are taken into account for the calculation of axial load ratio
The maximum load in a particular selected combination is taken and calculated for Axial load ratio
2741*1000/400/600/30=0.38 (approx to 0.4)
So it is almost good axial load ratio
Use Fz here


STEP 19: Check for Axial load Ratio for Shear walls it should not be greater than 0.28
For shear walls
For Load combination 15 to 26 we have 1.5 DL + 1.5 LL
Therefore these load combinations are taken into account for the calculation of axial load ratio
The maximum load in a particular selected combination is taken and calculated for Axial load ratio
2302*1000/400/600/30=0.32 > 0.28
So it is good axial load ratio
Use Fz here