  1. Typical floor plan – The location and thickness of the brick walls and the use of the
    space (for estimating live load) can be obtained from this plan
  2. A building section through the staircase and lift core is provided
  3. Parking layout in the ground floor – the column/shear wall arrangement must not
    obstruct entry/exit of vehicles.

STEP 1: Grid data

STEP 2: Storey data

Step 3: Material properties

COLUMNS

BEAMS

SLABS

SHEAR WALL

STEP 4: Changing Orientation and adjustment of shear walls and columns accordingly

STEP 5 : Adjustment of slab sections

STEP 6 : Providing support = Fixed support

View of sections

STEP 7: Defining Load Patterns

STEP 8: Assinging Loads Live load, Brick wall,Floor finish

STEP 9: Providing the Mass source

STEP 10: Defining Earthquake loads

Ta = (0.09*24)/squareroot of d = 4.5 seconds in both x and Y directions

STEP 11: Assigning Diaphragm

STEP 12: Giving PIER LABELS

STEP 13: Defining Response Spectrum Analysis

STEP 14:

Comparision of BASE REACTIONS using Equvivalent Lateral force method vs Modal Response Spectrum Analysis

Base shear for Eqx and Eq y is 3913.65KN

For MRSA to get Scale factor = 3913.65/24583 = 0.16

For MRSA to get Scale factor = 3913.65/680 = 5.75

Eqx,Eqy values should be approximately equal to RSx ,RSy

STEP 15 : Obtaining the same values for both as per step 14

This Analysis is RUN only after deleting the EQx and EQy.

Obtained approx values for RSx and RSy in comparision with EQx and EQy

STEP 16: Fundamental Time period of the modes is checked for the modes

No proper result for any type of load combinations for UX and UY

Using MRSA No proper result

Using EQ loads No proper result for UX and UY

Using Gravity loads No proper result for UX and UY

No proper result even after the analysis is obtained by using gravity loads (that is only DL,LL,Brick wall,Floor finish) + EQ loads in X and Y direction and the Beam at the opening between GRID B and C

other analysis is also done without Beam between GRID B and C

But still the value is same

also there is no proper modal participating mass ratios

In UX,UY direcctions in both the cases.

STEP 17: Check the BASE SHEAR for the EQx to make a way such that the total Lateral force in X direction is taken by the Shear walls is 75 to 80%

Here I got approx 61%

therefore the resizing of the model to be done for the Analyis of Building

That is the sizes of the Shear walls need to be increased.

SEE THE CALCULATION BELOW in calculator

Use Fx here

STEP 18: Check for Axial load Ratio for columns it should not be greater than 0.4

For columns

For Load combination 27 to 38 we have 0.9 DL

Therefore these load combinations are taken into account for the calculation of axial load ratio

The maximum load in a particular selected combination is taken and calculated for Axial load ratio

2741*1000/400/600/30=0.38 (approx to 0.4)

So it is almost good axial load ratio

Use Fz here

STEP 19: Check for Axial load Ratio for Shear walls it should not be greater than 0.28

For shear walls

For Load combination 15 to 26 we have 1.5 DL + 1.5 LL

Therefore these load combinations are taken into account for the calculation of axial load ratio

The maximum load in a particular selected combination is taken and calculated for Axial load ratio

2302*1000/400/600/30=0.32 > 0.28

So it is good axial load ratio

Use Fz here

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.