Challenge

Structural Modelling using Etabs 2018

The architectural drawings for a G+7 residential building in zone 5 has been provided. The floor plan is the same for all 7 floor levels. Possible column positions have also been provided. Conceptualize a framing plan layout and then model the building in Etabs. The following architectural drawings have been provided:

  • Typical floor plan – The location and thickness of the brick walls and the use of the
    space (for estimating live load) can be obtained from this plan
  • A building section through the staircase and lift core is provided
  • Parking layout in the ground floor – the column/shear wall arrangement must not
    obstruct entry/exit of vehicles.
    The following loadings are to be taken into account:
  • Brickwall made of AAC blocks
  • Finishes – floor tiles of 75 mm thickness
  • Live loads as per IS 875 part 2
  • Water tank of 20 KL above the staircase at Mumty level
  • Lift Machine room at mumty level above lift core

AIM

To model and analyze the G+7 Residential building at given architectural drawings by using Etabs Software.

PROCEDURE

STEP-1

  • Open the new model in Etabs.
  • Then open a another Tab of Given G+7 building model as included a floor plan, architectural plan, Typical cross sectional plan and elevation plan.
  • To analyze and observe the data from given model.
  • To set the Grid and story formation by custom.
  • X-direction in A,B,C &D and Y-direction in 1,2,3,4&5 at given base dimension.
  • The story are designed by G+7, each floor have 3 m in height.

STEP-2

  • To add Material properties of section for steel and concrete
  • Go to Define > Material properties > ADD.

STEP-3

  • To add the section properties of Beam, column and slab.
  • Go to section properties > frame > choose bram or column
  • Here used beam size is B 250 mm x 500mm
  • The column Size is C 400mm x 400mm, C 400 x 600.
  • To create slab section of Slab 115, slab 125, slab 150mm thickness.
  • Specially we add staircase slab of 200mm thickness.

STEP-4

  • To create a shear wall of this structure to protect the more lateral forces Zone.
  • Wall > section properties > wall section.
  • For here used, wall 300 thick.
  • The shear wall are covered as symmetric in nature for withstand the lateral shear force action.

STEP-5

  • After completing the addition of all materials of required in modeling.
  • Then we start to view the floor plan.
  • To select the Quick Column for selecting the required dimension.
  • Then, similarly to add the process of beam.
  • For most concentration about to adding the beam, because we read the given plan and understand the appropriate requirement of place to add beam.
  • If we want to delete or adding new beam inside the frame area.
  • Choose To Divide and Joint action for fixing the beam layout like our given plan.

STEP-6

  • Next, we add the slab @ thickness of slab 115.
  • Go to First floor, select all Stories after to add slab.
  • Then, go to base floor deleted the slab @ base.

STEP-7

  • To add the Shear wall of all Boundary condition and base point and mid portion of building as like a symmetric in nature.
  • Thickness of shear wall is 300mm.

STEP-8

  • Go to base plan and select one strory.
  • After select the all joints.
  • ASSIGN > Joints > Restraints > Fixed joints.

STEP-9

  • Then, most important factors of addition of load .
  • Define > load patterns > add the load 0f Dead, Live, Brickwall and Finishes.
  • Addition of brick wall load > Assign > Frame load > Distributed load > brick wall is 3.5 KN/m.
  • As the reference IS 1893 : 2016.

STEP-10

  • Then addition of Live @ different categories with the reference of IS 875 :PART 2.
  • Here assigned live of moving platform area is 3 KN/ m^2 and other room areas we put 2 KN/m^2.

STEP-11

  • To assist the Live load Reduction factor.
  • For this model is G+7, so definitely we need to consider the reduction factor.

STEP-12

  • Then, to add the earthquake load.
  • We need to natural period Ts = 0.49, as we find this from IS 1893:2016.
  • Next, add the Earthquake load of positive and negative of both direction.

STEP-13

  • To assign the Mass source with the condition of Specified load patterns
  • To reference of IS 1893:2016, Clause 7.3.1

STEP-14

  • The same we assign the Diaphragm of all stories.
  • Assign > shell > Diaphragm > D1 > apply.

STEP-15

  • Given the name to all pier of shear wall as like p1, p2, p3, p4, p5, p6, p7 & p8
  • Assign > shell > pier label @ selected wall.

STEP-16

  • To check and consideration of LOAD Combination @ all factors.

STEP-17

  • Model cases to finf the direction of different mode shapes.
  • Here we choosen 20 mode shapes.

STEP-18

  • Then , to check the analysis of all load cases.
  • RUN the analysis of model.

STEP-17

  • To view the Model spectrum analysis.
  • Define > Function > add the respected factors.
  • Choose function type > add new function with the reference of 1893:2016.
  • Then, to choose Load cases for adding all load cases into the both direction of response reduction factor.
  • RSx and RSy.
  • After adding this load, make the load combination as similarly we add this response spectrum load and check it.

STEP-18

  • As well as we get the base shear value @ all loads, on there we need to know the spectrum value for we considering the scale factor value.
  • Then, Re-run the analysis, to check the all base shear, combination, model shapes.
  • And also we get the view Story drift of maximum value as our model.

RESULTS

Finally, we analyze the model of G+7 are successful.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.