Challenge

Sketch a G+1 residential plan according to Vaastu Shastra and Calculation of Loads as per IS code

Important structural drawings required for site are :-

centre line drawing, footing and column layout with reinforcement details , plinth beam layout with reinforcemnet details, FF beam and slab details with reinforcement details, stair and headroom reinforcemnet details.

assume beams of sizes 200mm x 300 mm and columns of size 200mm x300mm, column height =4.5m, beam length=3m

dead loads

beam - 25x0.2x0.3x3=4.5 kN

column- 25x0.2x0.3x4.5=6.75 kN

slab - 25x0.12=3 kN/m2

wall load acting on beam = 20x0.2x4.5=18 kN/m

live loads

all room and kitchen -2kN/m2

bathroom /toilets = 2kN/m2

stair and store=3kN/m2