Given -

Design only a Main Frame with Lean (Grid 2) & Gable Frame without Lean (Grid 15)

• Assume purlin load as 8.77 kg/m = 0.086 KN/m.

• Assume Gantry girder wt. = 158.24 kg/m = 1.55 KN/m.

• Assume Rail weight = 53 kg/m = 0.5179 KN/m.

Building Parameters: -

1

Building Width=30000.00 mm

Out to Out of Steel

2

Building Length

140000.00 mm

Center to Center of Steel Column

3

Building Height=11100.00 mm

Clear Height from FFL

4

Roof Slope=1:10

5

Column Base

Fixed Base

Assumed

To control Deflection

6

Bay Spacing (in mm)

Main frame with Rafters:14@10000

Center to Center of Steel Column

7

Roof Bracing

Diagonal Angle Bracing

8

Wall Bracing

Portal Bracing and above Angle Bracing

Up to 6.5m Portal Bracing

9

End Wall Type

Rigid Frame

Assumed

GENERAL PARAMETERS

Loads & Design

1. Dead Load=0.14 KN/m2

Assumed

2. Coil Load=0.15 KN/m2

False ceiling load for Roof extension alone

3. Live Load=0.75 KN/m2

Code:IS 875 (Part 2) -2015

4.Wind Load

Wind Speed=180 KMPH

Code:IS 875 (Part 3) - 2015

K1 =1.00

Code:IS 875

(50 years of mean probable design life)

K2 =0.94

Code:IS 875

(Terrain Category 3)

K3 =1.00

Code:IS 875

(Upwind slope is less than 3°)

K4 =1.15

Code:IS 875 (Cyclone Zone)

Building Condition

Medium Permeability

Code:IS 875 (Part 3) - 2015

5.Seismic Zone

Zone III

Code:IS 1893-2015 (Part 4)

6. Loads applied as per:IS 875 - 2015

7.Primary Member design

IS 800: 2007

8.Cold Form Design AISI 2001

Assumed

• Procdure:

A) For main frame and gable frame:

Open staad -> define nodes and beams as per given data -> Go to translation assign bay specing.

For Area 1 - 30 m width.

roof slope = 1/10 = 0.1.

Height of roof in top level = 1.5 m.

• Add walls -> Add wall sheeting -> add roof sheeting.

• Add properties -> go properties section database ->add and assign section to structure.

Go to support -> create support -> add and assign support -> fixed base and pinned base.

• Go to loading -> add load defination and load case details -> assign loads to

structure.

• Total D.L. =

4.5+ 1.5 +1.5 +0.75 = 8.25 KN/m.

• Total L.L. = 22.5+ 7.5 +3.75 + 7.5 = 41.25 KN/m.

• Total Coll load = 0.15 x 30 = 4.5 KN/m.

Total wind load =184 KMPH= 50 m/s.

• Internal pressure coefficiant = +/- 0.5.

• External pressure coefficient:

-0.9

-0.4

-0.8

-0.4

• As per given data

Design wind speed = Vb x k1 x k2 x k3 x k4.

= 50 x 1 x 0.94 x 1 x 1.15.

= 54.05 m/s.

• Wind pressure = 0.6 x 54.05^2.

• 1.75 KN/m^2.

• As per IS 875 Wind direction factor kd = 1

Area averaging factor ka = 0.83 .

• Combination factor kc = 0.9

Design wind pressure = 1.75 x 1 x 0.83 x0.9= 1.307 KN/m^2.

• Wind load = 1.307 x 11.1 = 14.50 KN/m.

• O+CPI = 14.50+ 0.5 0.9 = 14.10 KN/m.

• 14.50+ 0.5 -0.4 = 14.6 KN/m.

• O - CPI = 14.50 - c 0.5-0.9 .9=13 KN/m.

• 90 + CPl = 14.50 + 0.5 - 0.8 = 14KN / m .

• 9O - CPI = 14.50 - 0 -0.8=13.2 KN/m.

• 14.50-0.5 0.4 = 13.6 KN/m.

• Seismic load =

EQ + X.

EQ - x.

EQ + Z.

EQ - Z.

• Add load combinations -> go to load combination add as per strength design and servicebility criteria.

• Go to design -> add design parameters ->Use IS 800: 2007.

• After run analysis and check deflection and section safe results.

B) For gable frame and gable frame.

Open staad -> define nodes and beams as per given data -> Go to translation assign bay specing.

For gable frame we analysis and design for one frame.

• For Area 1 - 30 m width.

• roof slope - 1/10 = 0.1.

Height of roof in top level = 1.5 m.

Add walls -> Add wall sheeting -> add roof sheeting

Add properties-> go properties section database ->add and assign section to structure.

• Go to support -> create support -> add and assign support -> fixed base and pinned base.

• Go to loading -> add load defination and load case details -> assign loads to structure.

• Total D.L.=4.5+1.5+1.5+0.75=8.25 KN/m.

Total L.L.=22.5+7.5+3.75+7.5=41.25 KN/m.

• Total Coll load =0.15*30=4.5 KN/m .

• Total wind load = 184 KMPH = 50 m/s.

• Internal pressure coefficiant = +/- 0.5.

• External pressure coefficiant =

-0.9

-0.4

-0.8

-0.4

• Combination factor kc = 0.9 .

Design wind pressure = 1.75 x 1 x 0.83 x 0.9. • 14.50-0.5 -0.4 = 13.6 KN/m.

• 90-CPI = .5-0.8=13.2 KN/m.

As per given data

Design wind speed = Vb x k1 x k2 x k3 x k4.

= 50 x 1x 0.94 x 1 x 1.15.

= 54.05 m/s.

Wind pressure = 0.6 x 54.05^2= 1.75 KN/m^2.

• as per IS 875 Wind direction factor kd = 1

• Area averaging factor ka = 0.83 .

• 1.307 KN/m^2.

• Wind load = 1.307 x 11.1 = 14.50 KN/m.

• O+CPI = 14.50+ 0.5 0.9 = 14.10 KN/m.

• 14.50 + 0.5 0.4 = 14.6 KN/m.

• O - CPI = 14.50 0.5 0.9 = 13KN / m .

• 9O + CPI = 14.50 -0.8=14 KN/m.

= 14.50 +0.5 0.4 = 14.6 KN/m.

. = 14.50 - 0.5 -0.4 = 13.6 KN/m.

Seismic load =

• EQ + X.

• EQ - X.

• EQ + Z.

• EQ - Z.

Add load combinations -> go to load combination add as per strength design and servicebility criteria.

Go to design -> add design parameters -> Use IS 800: 2007.

After run analysis and check deflection and section safe results.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.