Challenge

Project 1

Project 1

1. Design a multi-storey Residential Building located in Bangalore using STAAD Pro Connect Edition. The specification must be as follows:

Building floors

G + 6 + R

Plan dimension

B = 25m ,  L = 16m

Storey Height

h = 3.5m

Soil 

Hard soil

Use

Residential Purpose

Safe Bearing Capacity

180 kN/m2

Maximum slab thickness

150mm

Assume suitable sections for structural elements. Follow IS456, IS1893 and IS 875

  1. Prepare a Design Basis Report for the project
  2. Create structural model using STAAD Pro Connect Edition
  3. Prepare DL, LL, WL and EQL load calculations as per IS 875 standards
  4. Design slab element using MS – Excel
  5. Design beam and column element using STAAD RCDC. Attach the design calculation report.
  6. Design Foundations using STAAD Foundation.
  7. Prepare bar bending schedule for beam and column using STAAD RCDC
  8. Attach necessary sketches and drawings wherever required.
  9. All stipulations, assumptions and design parameter must adhere to Indian Standards.

AIM:

To design a multi-storey Residential Building located in Bangalore using STAAD Pro

INTRODUCTION:

STAAD Pro is a popular structural analysis application known for analysis, diverse applications of use, interoperability, and time-saving capabilities. It helps structural engineers perform 3D structural analysis and design for both steel and concrete structures.

PROCEDURE:

Design Basis Report:

Given data:

Building Floors : G+6+R

Plan Dimension : B=25m, L=16m

Story Height : h = 3.5m

Soil : Hard soil 

<!-- [if gte msEquation 12]>𝑍2.𝑆𝑎𝑔𝑅𝐼<![endif]--><!-- [if !msEquation]--><!--[endif]-->

Use : Residential purpose

Safe Bearing Capacity : 180 kN/m2

Maximum slab thickness : 150mm

Assume:

Beam size = 300mm X 450mm

Column size = 600mm X 600mm

Load Calculations:

Dead Load on Floor: (IS 875 Part-)

(Unit weight of concrete = 25 kN/m2)

Dead load due to slab = 0.15 x 25 = 3.75 kN/m2

Partitions : 1.5 kN/m2

Floor Finish : 2.5 kN/m2

Miscellaneous : 1 kN/m2

Total Floor Load = 8.75 kN/m2

Dead Load on Roof: (IS 875 part-1)

Dead load on roof slab = 3.75 kN/m2

Water proofing = 0.5 kN/m2

MEP services = 0.5 kN/m2

Miscellaneous = 0.5 kN/m2

Total Roof load = 5.25 kN/m2

Live Load: (IS 875 Part-2)

For residential building, LL = 3 kN/m2

For roof, LL = 1.5 kN/m2

Wind Load: (IS 875 Part-3)

Calculation of Wind Load (IS 875 - Part 3)    
               
Design Wind Speed    Vz = Vb k1 k2 k3 k4   m/s
Basic Wind Speed   Vb = 33 m/s  
Probability factor   k1 = 1  
Terrain factor , Category   for k2 = Category 4, Class B
Topography factor   k3 = 1  
Design Wind Pressure   Pz = 0.6 Vz2  
               
               
    Height k2  Vz  Pz Pz in kN  
    3.5 0.76 25 377.40 0.38  
    7.0 0.76 25 377.40 0.38  
    10.5 0.76 25 377.40 0.38  
    14.0 0.76 25 377.40 0.38  
    17.5 0.76 25 377.40 0.38  
    21.0 0.77 25 387.40 0.39  
    24.5 0.83 27 450.13 0.45  
    26.0 0.86 28 483.25 0.48  

Seismic Load:

Calculation of seismic load (IS 1893:2016 part-1) 

                 
Design Base Shear     VB = Ah W  kN    
Design Horizontal Acceleration Coefficient        
        Ah = ((Z/2).(Sa/g))/(R/I)    
                 
Zone factor     Z = 0.1 (Banglore: zone II, CL-6.4.2, TL-3)
Soil Condition factor , Sa / g     <!-- [if gte vml 1]> Bitmap <![endif]--><!-- [if !vml]-->
<!-- [if gte msEquation 12]>0.09h𝑑<![endif]--><!-- [if !msEquation]-->0.09h/√d<!--[endif]-->
   
        T =      
                 
Height of building     h = 26m    
Base dimension of building   Along X = 16m    
        Along Z = 25m    
                 
        T along X = 0.59s    
        T along Z = 0.47s    
        Sa / g  = 2.325 2.906  
                 
Response Reduction Factor   R = 5    
Importance Factor     I = 1    
                 
 Horizontal Acceleration Coefficient Ah = 0.0232    
        Ah = 2.3248  %    
                 
Seismic Weight              
Area of Each floor     A = 400 m2    
Due to Dead Loads  , Typical Floor DL = 8.75 kN/m2    
        W DL = 3500 kN    
Due to Dead Loads  ,Roof    DL roof = 5.25 kN/m2    
        ` = 2100 kN    
Due to Live Loads , Typical Floor LL = 3 kN/m2    
        W LL = 600 kN    
                 
                 
Due to Live Loads , Roof   LL = 3 kN/m2    
        W LL = 0 kN    
                 
Total Seismic Weight   W = 30800 kN    
                 
Design Base Shear   VB = 716.03 kN    
                 
                 
Lateral Force at Different Levels          
    <!-- [if gte vml 1]> Bitmap <![endif]--><!-- [if !vml]-->
 
   
 
<!--[endif]--><!-- [if !mso & vml]><![endif]-->
     
         
         
         
         
         
Storey level Wi  hi Wihi2 ki Lateral Force    
(kN) (m)     Qx Qz    
Roof 2100 26 1419600 0.17 120.28 120.28    
7th 4100 24.5 2461025 0.29 208.51 208.51    
6th 4100 21 1808100 0.21 153.19 153.19    
5th 4100 17.5 1255625 0.15 106.39 106.39    
4th 4100 14 803600 0.10 68.09 68.09    
3rd 4100 10.5 452025 0.05 38.30 38.30    
2nd 4100 7 200900 0.02 17.02 17.02    
1st 4100 3.5 50225 0.01 4.26 4.26    
    ∑ 8451100 1.00 716.0342 716.0342    
                 

Design slab element using MS – Excel:

Design of Slab (IS 456):    
               
  Span Shorter Direction (Clear) ly = 5.00 m
  Span Longer Direction (Clear) lx = 4.00 m
  Live Load on the Slab  LL = 3.00 kN / m2
  Compressive stength of concrete  fck = 30 N / mm2
  Yield strength of steel  fy = 415 N / mm2
  Unit weight of concrete Ƴc = 25.00 kN / m3
  Unit weight of floor finish 100 mm Ƴ = 22.00 kN / m3
  Clear concrete cover    = 25.00 mm
  Bearing of slab   B = 250.00 mm
               
Cl 24.1 Span to effective depth ratio l/d = 32  
  Minimum effective depth d = 150.00 mm
  Overall depth    D = 181.00 mm
  Provide Overall depth D = 150.00 mm
  Dia of bars for short direction Φ = 12 mm
  Dia of bars for long direction Φ = 12 mm
  Effective Depth   d = 119.00 mm
  Loading on the slab        
  Dead Load of the slab (DL)     3.75 kN / m2
  Super Dead Load       4.00 kN / m2
  Live Load on the slab       3.00 kN / m2
  Total Load on the slab (TL)     10.75 kN / m2
  Design Load = (Total Load x Load Factor i.e. 1.5) 16.13 kN / m2
  Effective Span   lx = 5.12 m
        ly = 4.12 m
  Ratio     ly/lx = 0.805 Two Way
T26/27              
      1.0 ax 1.10 ay  
For negative moments (at top) 0.047 0.035279 0.053 0.047  
For positive moments (at bottom) 0.035 0.025232 0.04 0.035  
               
BM per unit width of slab   Mx = ax w lx2 My = ay w lx2
  For negative moments (at top) 14.91   19.86 KN-m/m
  For positive moments (at bottom) 10.66   14.79 KN-m/m
  Shear force , V 0.5wlx 41.27     kN/m
               
To check the effective depth of slab        
        Mu,lim = 0.138fckbd2
        d = 60.01 mm
               
Depth of slab for shear force          
T20       τc,max = 3.5 N/mm2
        τc = 0.29  
Cl 40.2.1       k = 1.3  D=150mm
        τc = 0.377 N/mm2
        τv = Vu / bd  
          = 0.35 N/mm2
        τv <      τc <  τc,max  
        0.35 0.38 3.5  
          SAFE    
               
Determination of areas of steel          
        Mu = 0.87fyAstd(1-Astfy/fckbd)
For Negative moments   Mu Top = 14.91  
        Ast = 434.56 mm2/m
               
For Positive moments   Mu Bot = 10.66  
        Ast = 310.81 mm2/m
               
Determination of distribution steel        
        Astmin = 0.12bd  
            142.8 mm2
               
Selection of reinforcing bars          
    Area of bars (Top steel) = 113.04 mm2
      Spacing = 260  
          = 240 mm
      Provide 12mm bars at a spacing 240mm  
               
    Area of bars (Bottom steel) = 113.04 mm2
      Spacing = 364  
          = 300 mm
      Provide 12mm bars at a spacing 300mm  
               

Create structural model using STAAD Pro Connect Edition:

  • Open STAAD Pro software and first we need to create a frame layout
  • Select structural wizard option

  • Change the model type in 'Frame models' then select the Bay frame option

  • The selected parameter dialog box is appeared now define the parameters as what we want and click apply

- Then merge in to STAAD model and also create a roof in normal method

- Now create the beam properties and materials

- The same procedure to follow the create the column properties and materials

- Now assign to the columns and beams using select option in parallel Y

- The beams have been assigned to the selected parallel X and Z asssign to it

- Create a support select fixed support option

- Add seismic load, so first loading tab and click new option, the dialog box will be appeared

- Click generate option the seismic parameter dialog box is appeared and fill the details were given

- Next add the seismic self weight

- Now select the Wind definition option and click add button, give the name and click add. 

- Add wind exposures

- Now craete load case details, add the Earthquake load in the X and -X direction

- Now add the earthquake load in Z and -Z direction

- Add the wind case in X and Z direction

X - Windward

-X - Leeward

Z - windward

-Z - Leeward

- Now define the dead load and live load. Click load case details and select add option to add dead load, live load. first assign the selfweight in dead load. Then assign the dead load of floor

- Now assign the dead load of roof

- Now assign the Live load on floor

- Then Live load on roof

- Now Add load combination and select Auto load combination option

- Here now all the loads has been applied successfully, noe run the analysis

- Shear Force

- Bending moment

- Click the Report tab

- Right click on the mouse there is 3D rendering option and click that

Design beam and column element using STAAD RCDC:

- In the STAAD Pro model there is a option called RCDC to design the beam and column. Create a new project and fill the detail

- After creating new project the beam details as shown

- Go to setting tab > click General and Reinforcement and fill the data

- Again go to setting tab > Rebar curtailment

- Now acquire the load combination

- Import the load combination

- Go to design tab > click Auto design option

- Now check the failure diagnostics, go to Reports tab > Failure diagnostics 

- None of the beams have failed

- Next click Repots > design summary

- Go to Report > Elevation 

- And now we going to design the column

- Create the new project

- go to setting > General and Reinforcement

- Now acquire the load combination

- Import that load combination

- Now check the failur diagnostics click Reports > Failure diagnostics 

- There is No failed columns

- Go to report > Elevation option

 

- Go to report tab > Design summary

Design Foundations using STAAD Foundation:

- In STAAD Pro model there is a Foundation design option

- Click STAAD foundation advanced

- Generate the load combination

- Create the job information

- Concrete and Reinforcement

- Isolated Footing design

- Detail ans Schedule drawing

- GA drawing

Prepare bar bending schedule for beam and column using STAAD RCDC:

Bar Bending Schedule for Beam:

 Bar Bending Schedule for Column:

 

RESULT:

Hence the beams and columns are designed using RCDC, Foundation are designed using STAAD foundation, all the tasks are successfully performed and necessary files are attached.