Modelling of 25 storey building with the specified properties using ETABS

  • Aim: To Model a 25 Storey on ETABS With structural Properties as Specified Below. Ground Floor or Plinth Floor Level Can Be Taken at a Height of 1.5 Meters from the base. Each of the Successive 25 storeys has a storey height of 3 Metres
  • Structural Element Sizes:
  • Beams: 300 × 400 mm
  • Columns: 800 × 800 mm
  • Slab: 150 mm thick
  • Material Properties
  • Grade of Concrete : M30
  • Grade of Steel Reinforcement Bars : Fe 415
  • Loading
  • Dead Load on beams from infill wall : 10 kN/m (Let us assume the same for roof floor in view of parapet)
  • Live load on floor : 3 kN/m2 (Let us assume the same for roof floor)
  1. a) Buildings are assumed to be pinned at the base
  1. b) All columns in all storey are of the same size
  1. c) All beams in all storeys are of the same size
  1. d) Building is located on Soil type-II and in Zone-III. Assume other factors if required.
  • To Carry out the following exercises:
  • Check if the translational fundamental natural period of vibration in both the x and y direction is approximately:
  • Tx1= 4.4 second Ty1= 4.2 second
  • This check will help confirm if modelling is done correctly. Some deviations from the above values is possible (± 2%). But any major deviation will suggest an error in modelling.
  • Check if the following provision in Table 5 of IS 1893 (part 1) – 2016, on torsional irregularity satisfied:
  • The natural period corresponding to the torsional mode of oscillation must be less than the two fundamental translational modes of oscillation along each principal plan directions.
  • Check if the two provisions of clause 7 in Table 6 (shown below) of IS 1893 (part 1) – 2016, regarding vertical irregularity is satisfied
  • Procedure:
  • Open the ETABS Application and Click on the New Model Option From the File Menu
  • Now in the Model Initiation Window Desired Units, Design Codes Which are to be Used was selected and then Click ok
  • In New Model Quick Templates Under Grid Dimensions Select the Custom Grid Spacing and then Click edit Grid Data
  • The Grid dimensions Was Inserted according to question as follows and Click Ok
  • In New Model Quick Templates under Story dimensions Select the Custom Story Data and then Click Edit Story Data
  • Now Input the storey Details as given In Question and Story 1 was Selected as the Master Story and was applied to rest story From 2nd Story to roof and then Click ok.
  • The Plan and 3D View of all the data’s Which we have given till now is shown on the Image Below
  • Now to Define the Properties of elements go to define menu and then select Material Properties. The Grade of Concrete was Selected and Click ok
  • The Material Property data Dialogue Box will Show Up Ensure all the data’s are Correct and then Click Ok at the Bottom
  • Similarly HYSD 500 and HYSD 415 Steel Was Added
  • Steel and Concrete properties was added to the list now as shown and then Click Ok
  • Now, We Need to add the frame Members I.e. Beams, Columns and Slabs. Go to Define Tb>Section Properties>Frame Sections
  • Frame Properties window Opens and in that go to add new Material Property
  • The Reinforcement Details and Cover to the Reinforcement is also Provided
  • Similarly add Column to the list by providing the reinforcement details
  • Hence the Materials added to the list is as given below
  • Next we have to add the slab details. For this go to define tab> section Property> slab sections. Box Opens in the edit the Slab Properties
  • So all the Properties Frame members have been added correctly, now we have to place the structural Members
  • For this choose quick draw column option from the tools available at the left side of the screen and place the columns at all the grid intersections
  • Since columns extends throughout the height of the structure so care should be taken to check whether columns are assigned to all storeys
  • Next we have to place the position of beams, for this also quick draw beams option can be choosen
  • Now we have to create the slabs for this initially change the all storeys option to similar storeys which may exclude the base
  • Then choose quick draw floor or wall option to easily draw the floor slabs
  • Next we have to assign loads to the frame for this go define tab>Load Patterns> Define Load Patterns Dialogue box appears. Then apply the Loads .
  • Now Provide the Mass source Value to Calculate the Seismic weight
  • We Need to define the Load Combination For this Go define>Load Combination. Provided the Default Load Combination Itself
  • Choose Concrete Frame Design and Click
  • Select all the Floors. Select>Object Type>Floors. Hence all the Floors are Selected
  • Then Go to Assign > Shell Loads > Uniform> Live Loads> 3Kn/m^2>Apply>Ok.
  • Select all the Floors Select Object Type Beams . Hence all the Beams are Selected
  • Then Go to assign Frame Loads Distributed>Load Patterns>Brick Wall Load>Load>10 Kn/m>apply ok
  • We have to keep the support as pinned so for this select all joints by keeping in view the base storey
  • Then go to assign>Joint>restraint>select Pinned Joint
  • Go to analysis tab>Check Model>Its Checked for any Errors and Warnings
  • Now the Model Can be analysed for this, Go to analysis>run Analysis.
  • Hence , analysis has been Completed
  • Now, we need to check the details given in the question
  • So, for this initially go to display tab show tables>analysis result>Structure Out put>Model Information> Model Periods and Frequencies
  • Check if the translational fundamental natural period of vibration in both the x and y direction is approximately: Tx1= 3.7 second Ty1= 3.9 second
  • This check will help confirm if modelling is done correctly. Some deviations from the above values is possible (± 2%). But any major deviation will suggest an error in modelling.
  • This check will help confirm if modelling is done correctly. Some deviations from the above values is possible (± 2%). But any major deviation will suggest an error in modelling.

    • Check if the following provision in Table 5 of IS 1893 (part 1) – 2016, on torsional irregularity satisfied:
    • Tx1= 3.7 second Ty1= 3.9 second
  • Hence its Verified that the natural Period Corresponding to the torsional mode of oscillation is less than the natural period corresponding to two translational modes of oscillation

  • Now model Participation ratios to be taken for this got o display tab>show tables>analysis result>Structure Output>Model Information>Modal Participating Mass ratios

  • Check if the two provisions of clause 7 in Table 6 (shown below) of IS 1893 (part 1) – 2016, regarding vertical irregularity is satisfied
  • Modal Mass participation ratios of first three modes in x direction is obtained as obtained are
  • 1st =0.2038
  • 2nd = 0.8004
  • 3rd= 0
  • Summing these three we get 0.8004+0.2036+0=1.004=100%.65% hence satisfied the Criteria
  • Now the Difference between x and Y time Period is Given by 3.912-3.756=0.156=3.98% hence satisfied the Criteria
  • Check the Provision on inter storey Drift Limitations in Clause 7.11.1.1 Satisfied
  • Please Note that this Check is for serviceability limit state and hence is for situation when structure is subjected to unfactored seismic base shear
  • For Obtaining the story drift graph go to display >story response plots>Change the Display type to Max to Story drift> Load Case Combo

  • Here the maximum storey drift obtained is 0.0027 which is less than 0.004 hence local Provision is satisfied

  • Model a 25 storey building on ETABS with structural properties as specified Checks also Carried out. The Structure Satisfies all the Codal

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.