Identification of Cracks
What is the mode of failure or damage of the beams in the figure above? Are the damages repairable? Elaborate
Question1:
a) observations:
- concrete spalled beyond the reinforcement it may cause rupture.
- concrete crushed and reinforcement exposed.
- The beam top looks safe being slab supports there.
- the crack develops from the bottom of the top means rebar yielding occurs in the support bottom only.
answers:
- its forms of flexural failure due to reverse stress during an earthquake,
- top compression is managed by slab but bottom compression is not satisfied with provided reinforcement.
- during stress reversal and support top experience compression, bottom experience tension,
- since the reinforcement got yielded, it can not be replaced.
b) observations:
- cracks along the beam-column edge.
- cracks seem to have developed through the structure as it looks much wider.
- beams look separated from the column points,
- concrete is not severely crushed.
answers:
- its beam pull-out failure it happens due to insufficient development length of reinforcement joints.
- during earthquake conditions, these conditions make the beam detach from the column.
- providing the anchorage length between two existing concrete is very difficult. son not repairable.
c) observations:
- cracks are exactly at the joint of the column beam,
- cracks in the beam developed through its entire width.
- the slab also developed more cracks along the beam width direction.
answers:
- its a plastic hinge failure,
- the damage occurred only in the joint zone,
- cyclic lateral loading and stress reversal at the joints led to the damage,
- even the slab participated to its best to handle the tension but was unable to control the damage,
- the joint can be strengthened.
2)
a) observations:
- concrete damaged at top of the column,
- concrete damaged all along the face of the column face,
- beams are safe,
- the location of the column looks at the edge of the building.
- no walls are built along the column means it is probably on the ground floor. for parking car movement access.
answers:
- it is a plastic hinge failure,
- due to the absence of an infill wall on the ground floor, the plastic hinge formed at top of ground story column during lateral movement,
- based on the development of crushed concrete it can be either repairable or nonrepairable.
b) observations:
- concrete developed complete breaking diagonally,
- longitudinal reinforcement is intact.
- shear reinforcement spacing looks wider.
answers:
- its pure shear failure,
- inadequate shear reinforcement compels concrete to take all the shear stresses.
c)observations:
- column failed completely,
- failure at top of the column,
- there are two slabs connected to the column probably one at mid-height of the column.
answers:
- it is a short column failure,
- an additional slab or beam connected to a column in mid-height leads to this effect.
- this leads to failure, especially if the connections are unintentional and not accounted for in the design.