Challenge

Identification of Cracks

What is the mode of failure or damage of the beams in the figure above? Are the damages repairable? Elaborate

Question1:

a) observations:

  • concrete spalled beyond the reinforcement it may cause rupture.
  • concrete crushed and reinforcement exposed.
  • The beam top looks safe being slab supports there.
  • the crack develops from the bottom of the top means rebar yielding occurs in the support bottom only.

answers:

  • its forms of flexural failure due to reverse stress during an earthquake,
  • top compression is managed by slab but bottom compression is not satisfied with provided reinforcement.
  • during stress reversal and support top experience compression, bottom experience tension,
  • since the reinforcement got yielded, it can not be replaced.

b) observations:

  • cracks along the beam-column edge.
  • cracks seem to have developed through the structure as it looks much wider.
  • beams look separated from the column points,
  • concrete is not severely crushed.

answers:

  • its beam pull-out failure it happens due to insufficient development length of reinforcement joints.
  • during earthquake conditions, these conditions make the beam detach from the column.
  • providing the anchorage length between two existing concrete is very difficult. son not repairable.

c) observations:

  • cracks are exactly at the joint of the column beam,
  • cracks in the beam developed through its entire width.
  • the slab also developed more cracks along the beam width direction.

answers:

  • its a plastic hinge failure,
  • the damage occurred only in the joint zone,
  • cyclic lateral loading and stress reversal at the joints led to the damage,
  • even the slab participated to its best to handle the tension but was unable to control the damage,
  • the joint can be strengthened.

2)

a) observations:

  • concrete damaged at top of the column,
  • concrete damaged all along the face of the column face,
  • beams are safe,
  • the location of the column looks at the edge of the building.
  • no walls are built along the column means it is probably on the ground floor. for parking car movement access.

answers:

  • it is a plastic hinge failure,
  • due to the absence of an infill wall on the ground floor, the plastic hinge formed at top of ground story column during lateral movement,
  • based on the development of crushed concrete it can be either repairable or nonrepairable.

b) observations:

  • concrete developed complete breaking diagonally,
  • longitudinal reinforcement is intact.
  • shear reinforcement spacing looks wider.

answers:

  • its pure shear failure,
  • inadequate shear reinforcement compels concrete to take all the shear stresses.

c)observations:

  • column failed completely,
  • failure at top of the column,
  • there are two slabs connected to the column probably one at mid-height of the column.

answers:

  • it is a short column failure,
  • an additional slab or beam connected to a column in mid-height leads to this effect.
  • this leads to failure, especially if the connections are unintentional and not accounted for in the design.