Challenge

Foundation Design using SAFE

1.

INTRODUCTION :

The aim of the challenge is isolated footing design as per the manual calculation done already.

PROCEDURE:

A. ) PROCEDURE TO MODEL, ANALYSE AND DESIGN THE ISOLATED FOOTING ON SAFE :

Step 1 :

  • Creating a new model

Step 2 :

  • Using the default Pre-sets window single footing is created.
  • Assumed concrete footing thickness is 800mm.

Step 3:

MATERIAL DEFINITION :

Concrete property - M25 grade

Modulus of elasticity - E=25000 N/mm^2.

Rebar property - Fe500

Step 4:

SECTIONAL PROPERTY:

  • For footing slab MAT type property and 800mm thick considered.
  • For stiffened member Slab stiff type property considered.

Step 5:

LOAD ASSIGNMENT:

  • Defining Load Pattern - Dead and Live Load.

Step 6:

CREATE LOAD COMBINATION:

Dead - 1.5

Live - 1..5

Step 7:

ANALYSIS :

Performed Analysis

Displacement - The deflection obtained is 6mm only which is allowable minimum deflection.

Step 8:

SLAB DESIGN:

  • X Direction Strip (Reinforcement Required)

  • Y Direction Strip (Reinforcement Required)

2.

INTRODUCTION :

The aim of the challenge is Pile and Pile cap design along with column as per the given values.

PROCEDURE:

B. ) PROCEDURE TO MODEL, ANALYSE AND DESIGN THE PILE CAP ON SAFE :

STEP 1 :

Creating a new model

STEP 2:

  • Using the Grid tab the Pile cap slab is created.
  • Given concrete pile cap slab thickness is 500mm.

STEP 3:

  • The created Pile Cap slab at a size of 4mx4m in a thickness of 500mm.

STEP 4:

MATERIAL DEFINITION :

  • Concrete property - M25 grade
  • Modulus of elasticity - E=25000 N/mm^2.
  • Rebar property - Fe500

STEP : 5

SECTIONAL PROPERTY:

  • For Pile and Pile Cap type property 500mm thick considered.
  • For stiffened member Slab stiff type property considered.

STEP 6:

Then the Reference points are then marked at the appropriate distances.

STEP : 7

  • The Piles and Column slabs are drawn around the Reference points.
  • The appropriate properties should be selected before applying.

STEP : 8

  • The spring load should be calculated as per the formula and apply for all the piles +z direction

STEP : 9

  • Likewise the unfactored load for the column should also be applied in -z direction.

STEP 10:

  • The clear cover spaces and Bar sizes should be customized in the Preference tab.

  • After analysisng the Result of the Analysed Slab due to the acting load of Piles and Columns.

SLAB DESIGN:

  • X Direction Strip (Reinforcement Required)
  • Y Direction Strip (Reinforcement Required)