Design of Shallow Foundation (Isolated Footings)
AIM=Design a square footing for a column size of 400x400. The compression axial load for the load combination of (1.5 DL + 1.5 LL) is 2000 KN. The safe soil bearing capacity is 150 KN/m2 at a depth of 2 metres below E.G.L. Participants are free to go for either a tapered or stepped footing. Besides the total axial load, also account for the self-weight of the footing and soil above it. Assume M25 concrete grade.
- Steps involved in ooting design
- calculation of gross soil pressure for footing area
- calculation of Net soil pressure for flexure and shear design
- Initial depth of footing calculation
- Flexural Reinforcement calculation
- One way shear check
- Two way shear check
- Unfactored Load with surcharge+self weight of footing /allowable soil pressure
A =(2000/1.5 x 1.1)/150
A= 9.78 M^2
Here 1.5 is the factor use to calculate Factored laod
For square footing
B=sqrt 9.78
B =3.12 m
Hence consider 3.20m sided islolated footing
- Net soil pressure and intial footing depth
=Factored load /actual area of footing
= 2000/(3.2x3.2)
Pn = 195.3 KN/m^2
Assume depth pf footing 500mm and check it for bearing stress as per IS 456:2000 Clause 34.4

=Sqrt(Footing base bearing area/loaded area)

Permissible bearig stress 0.45 Fck =0.45x25 (M25)
= 11.25 N/mm^2
permissible bearing stress multiplied with area factor =11.25x2 =22.5 N/mm^2
Actual bearing stress at the column base
= (2000x1000)/(400x400)
= 12.5 N/mm^2
12.5 N/mm^2 actual stress is less than permissible stress 22.5 N/mm^2 Hence OK
We can proceed with depth 500mm footing for further design checks
if we assume 50mm cover for footing the effective depth d shall be taken as (500-50) =450mm
- Flexural Reinforcement
Conversion of net pressure intpo uniformly distributed load
= 195.3x3.2
= 625 KN/m
Bending moment due to UDL over cantilever section
M =WL^2/2
M= (652x1.61.6)/2
M=800 KN-M
Reinforcement Calculation as per the 456:2000

Assume Fy=500 N/mm^2
After calculation get Ast=5146 mm^2
if we provide 16 mm bar with 125 mm spacing
than actual rebar provided =(3200/125x201)
Ast provided = 5146mm^2
- One way shear check
one way shear check at the distance d from face of the column
Shear force in teh one way shaded area
=0.95x3.2x195.3
= 593.7 KN
Design shear at one way cut face
= 593.7x1000/(3200x450)
= 0.412 N/mm^2
Shear stress capacity of section as per IS 456:2000
=0.425N/mm^2
Design shear stress is less than the shear capacity Hence ok
- Two way shear ( Punching shear ) Check
In two way shear critical section lies at the distance d/2 from face of the column
So 450/2 =225mm
Shear force in the two way shaded area
= (3.2x3.2)-(0.85x.85)x 195.3
=1859 KN
Design shear stress at two way cut face
tau v =1859x1000/(3400x450)
= 1.215 N/mm^2
Shear stress capacity of the section as per IS 456:2000
=0.25 Sqrt Fck
=0.25 x sqrt 25
=1.25 N/mm^2
Design shear is less than shear capacity (Hence Ok)
DETAILS OF REINFORCEMENT OF THE FOOTING