Challenge

Concept on positioning of Columns

1)

INVESTIGATION of the framing paln with respect to symmetry in X-direction:

If we split the plan vertically half,it will look mirrored .so we conclude the given plan is symmetric in X-direction

INVESTIGATION of the framing paln with respect to symmetry in Y-direction:

If we split the plan vertically half,it will look mirrored .so we conclude the given plan is symmetric in Y-direction

INVESTIGATION of the framing paln with respect to redundancy in X-direction

The columns in x-direction are comparatively more and evenly spaced .so the structure is more redundant in X-direction .Expect the top and bottom column rows are having quite longer spans

INVESTIGATION of the framing paln with respect to redundancy in Y-direction:

The columns in Y-direction are comparatively lesser but evenly spaced . so the structure is redundant but lesser than that of in X-direction

INVESTIGATION with respect to Bi- directional stiffness:

  • The columns in horizontal direction are connected with straight to straight beams.This means,any lateral load (seismic force in x direction) passing from left end of the buildiing will have its path straight till it reaches right end of the building so no or less possibility of force diversion takes place
  • The columns in vertical direction are not connected with straight to straight beams.so a lateral load passing from south side of building will get diverted to east & west direction to reach next bay. There will be major force diversion takes place with seismic force in y -direction .The framing plan is weak with respect to bi directional stiffenss in Y- direction

INVESTIGATION of the framing paln with respect to ductility:

  • Prima facie,the aspect ratio of the plan clearly hints more column in X-direction compared to Y-direction .It will result in higher stiffness of the building in X-direction,which would reduce ductility in x-axis
  • Moreover ,the x-force will easily pass from one bay to its next due to beam allignment .whereas,the y -force will struggle to pass through .The north south beams are arranged in zig-zag which leads to a discontinous bracing.
  • We can conclude that the given framing plan is more ductile in Y-direction than that of in X-direction

2)

  • vertical irregularity:The building plan area is large in bottom stories.The floor plan areas are getting reduced with increase in height .These building offsets has to be crosschecked with reference to IS-1893-2016 Table 6 serial number (111)
  • soft storey:The building has uncovered opening space in 6th floor .As there is non occcupancy or a partition wall,this will lead to a plastic hinge formation at the columns (with reference to IS-1893-2016 FIGURE 4A).This has to be checked and sufficiently designed
  • slopy base:The building is constructed on a sloping ground at on side .This will lead to significant variations in the stiffness (withb reference to IS -1893-2016 figure 5E) few levels may be subjected to soft storey mechanism.

3)

  • open ground floor- This denotes soft storey mechanism acting in the building
  • Rooms along 2 bays are separated by an open corridor :The bays filled with rooms will have higher mass compared to the middle bay left open for corridor .This includes mass irregularity along height uniformly.
  • Two short sides covered with infill walls:This means the buildings left and right sides periphery is more stiffer during seismic forces (especially along North-South )
  • Staircase portion at left top corner :usually staircase and lift portions are stiffer than other parts because of concentrated concrete elements .so the staircase portion contains more stiffness in the provided building plan
  • No framing connection along Y direction:we could see no structural beams provided along the vertical direction between columns.This makes the building more vulnerable during the North South seismic force.
  • Beams connected along column minor axis :The columns are having longer dimension in Y-direction.This means they are more stiffer along Y-direction.This means they are more stiffer along Y -direction .But the beams are running only along X-direction which would attract much lesser lateral forces and hardly transfers it.
  • Variation in column size :The internal columns are having higher sizes compared to exterior columns(This is common because of higher load demands) But this will lead to significant differences in lateral drift of columns.so the concrete floor might have suffered heavy out of plane shear which would led to collapse.