← Previous lessonFree lesson 3 of 3 · lesson 3 of 66

Unlock all 66 lessons of Structural Stability of Lateral ForcesFull course ₹40,000 · paid

Price & syllabus
Free lesson · 20 min · no payment

Buckling Modes and Frame Stability Under Lateral Loads

A free lesson from Skill-Lync's Structural Stability of Lateral Forces course, on Grow by Skill-Lync · Last updated 16 Nov 2026 · Session: “Understanding Global and Local Instabilities in Structural Engineering”

What will you learn in this free Structural Stability of Lateral Forces lesson?

The instructor covers buckling: Euler critical load for pinned, cantilever and fixed ends, flexural torsional, lateral torsional and plate buckling, with IS 800-2007 width-to-thickness limits. The lesson then compares frames with sway prevented and sway permitted, using infinitely stiff and infinitely flexible beams.

  • Euler critical buckling load and end restraints
  • Flexural torsional and lateral torsional buckling
  • Plate buckling limits from IS 800-2007
  • Column buckling in sway and non-sway frames

What comes after lesson 3?

Later in Skill-Lync's Structural Stability of Lateral Forces course (paid): lesson 4, Introduction to Frame Behavior Under Lateral Loads; lesson 5, Structural Stability for Lateral Forces; lesson 6, Construction Phase Loadings and Structural Considerations. The full course has 66 lessons (17 h 43 min of video); see the course overview or its price and syllabus.

Lesson transcript

Machine transcript of the lesson audio (lightly cleaned). Technical terms may contain errors; the video is the reference.

Global instabilities. So continuing on the global instabilities topic, as the loads on a structure increases, its stiffness decreases. Stiffness of the structure decreases due to the following reasons. The first one being inelasticity of material. The second one is due to significant geometrical deformations. The maximum load capacity of the structure is attained when its stiffness becomes zero. This is referred to as the neutral equilibrium state of the structure. When the stiffness of the structure becomes negative, then the structure becomes unstable. Buckling of the frame is a function of buckling of its individual elements.

Buckling of the structure is defined as the transitional state of an element from its stable equilibrium state to an unstable one. Buckling can be described as a dynamic process that happens when a loss in the equilibrium path takes place. The load that triggers buckling in a compression element is referred to as the critical buckling load. Therefore, structural engineers should always be of an interest in order to find out the critical buckling load of the individual elements as well as the structure as an overall and make sure that the loads that the individual elements are subjected to as well as the overall structure do not exceed the critical buckling loads.

Otherwise, the structure will be categorized as an unstable structure. The theoretical buckling load is calculated as a characteristic or eigenvalue of some eigenboundary value problem from various mathematical models that we spoke about previously. The structural phase after buckling is referred to as the post-buckling response of a structure, and the structure becomes in an either neutral or unstable equilibrium state. Plastic hinges form in slender columns after experiencing significant plastic deflections. Numerous structural configurations are typically governed by buckling. The slide on the right-hand side illustrates the various buckling instabilities that can occur in a structure.

These are local buckling, the figure on the very left-hand side, overall flexural buckling, and torgenal buckling. So, buckling occurs at a local element level. So, there is the buckling at a local element level, and there is buckling at a global element, global structural level. The one that we are talking about in this slide are the local element buckling modes. Again, the buckling types in steel structures are oler buckling, flexural torgenal buckling, lateral torgenal buckling, plates local buckling. A common, so, now we are going to talk about oler buckling, which is a type of a local buckling that happen at an individual element level.

It is a common phenomena that occurs in long axially loaded elements under compression. It is defined as the load at which an axially loaded column can no longer become straight, and this is referred to as the critical oler buckling load, p-cret. So, this is when your element can no longer maintain its straightness. The oler critical buckling load is considerably dependent on the effective buckling length of the column, that in turn is dependent on its end restraint. So, the longer your column is, the more susceptible it is going to be to the oler buckling load.

Also, the end restraint of a column govern its susceptibility to oler buckling load. For example, whether it is freely supported at the end, so it can't leave a column, pinned at the bottom and the top, or fixed at the bottom and the top. Oler buckling load, continuing on this topic, the longer, i.e. the more slender the column is, with fewer restraint along its height, the more it is susceptible to this buckling mode. When a column attains its yield strength before its critical buckling load, then it is referred to as a stocky column, and buckling will not take place, since the column failed due to it reaching its design capacity rather than its buckling limit load.

The figures on this slide demonstrate the oler buckling load, so you see you have a slender or a long compression member. When we apply compression force F to this member, it will start to buckle. The moment it no longer becomes straight, this is what we refer to as the critical buckling load of the element. So this is the load when the element can no longer maintain its straightness. We can see we can plot the relationship between the stress in the element against its slenderness ratio, so L divided by R.

So for slender columns, long columns, you can see that peak crit is of a lower value, so that means at the lower load, you can buckle the column. And then there is intermediate and short, which are referred to as stocky columns, it will fail before it reaches its buckling load. So you can utilize its full design capacity strength. The two figures on the right hand side illustrate the various restrained conditions at the end of the element, and their effect on the buckling load. So you can see for a figure A, where both ends are pinned, you can see peak crit value is equal to pi squared EI divided by the length of the element squared.

When it is cantilevering column, you can see that peak crit reduces in value to quarter, and you can see another restraining condition, where you have it as fixed and a roller, and that increases it by four times of the value of when both ends are pinned. So for a pinned column, the critical buckling load is equal to pi squared EI divided by L squared. And then we account for the restrained conditions by modifying this value according to the various restraining conditions that we are dealing with.

Now, speaking about the other type of local or individual element level buckling, which is the flexural torsional buckling, it is a common phenomenon that occur in sections with very low torsional restraints, such as cruciform columns. Open steel sections loaded in compressions with sheer center eccentric to their centroids are susceptible to this mode of buckling. Examples for such sections are T's, channels, single and double angles, as well as asymmetric I sections. So, this mode of buckling is characterized by simultaneous bending, as well as twisting, warping are the main characteristics of this buckling instability mode.

You can see the figure on the right-hand side, illustrates this buckling mode. So, the shear center is away from the centroid of the element, where the load is applied. And this is what makes the individual element susceptible to this mode of buckling. So, flexural torsional buckling is analogous to Euler buckling, but with additional twist. This is due to the eccentricity between the shear center and the geometrical centroid of the element. Typically, the flexural torsional buckling load is lower in value in comparison to the Euler buckling load.

Lateral torsional buckling, which is the third element buckling mode. It commonly occurs in members in bending about the major axis such as beams. This buckling instability mode is influenced by lateral and torsional deformations of beams, due to the compression experienced by the compression flange of the beam. Then, the Thank you. The longer the span of a beam with fewer restraints along its length, the more susceptible it is to lateral torginal buckling. So the longer the beam becomes with fewer restraints to its compression flange, the more susceptible it is going to be to lateral torginal buckling.

The figure illustrates the phenomena that happen when lateral torginal buckling takes place. You can see this beam is subjected to bending about its major axis, with no restraint for its compression top flange along its length, and therefore lateral torginal buckling took place. Lateral torginal buckling is highly dependent on the unrestrained length of a beam that in turn is dependent on its support conditions. Another individual buckling mode is called plates buckling. This commonly occurs in plate and shell elements, so in the web of a beam or flange of a beam, so at individual plates level rather than at the whole element level.

Unrestrained plates in relation to their out-of-plane axes are susceptible to this mode of buckling instability. For example, webs and flanges of I-steel cross-sections. Steel design codes specify limits to prevent this mode of instability. These limits are a function of the used material yield strength, so various codes deal with this issue by specifying a maximum width-to-thickness ratio for the individual elements that make up a member. And as long as you are within these ranges, this mode of instability can be avoided. So you can see on the right-hand side, this figure is taken from IS, from the Indian standard code, IS 800-2007.

You can see the various limits for class 1 plastic, class 2 compact, class 3 semi-compact. And depending on the elements that you are using and whether it is in compression, bending or tension, these are the limits that you need to abide by. And the limit itself is a function of the material yield strength used. So again, this table is taken from IS 800-2007 and illustrates the various width-to-thickness limits imposed by the code. So now we are going to talk about frame buckling mode, which is the overall buckling behavior of the structure or frame rather than looking at its individual members.

Buckling modes that we discussed previously assume that a member exists in isolation. However, in real structures, multiple elements work together in harmony in order to support the applied loads on the structure. Ends of the elements in real structures are neither fully pinned or fixed. Instead, they are elastically restrained by adjacent members they are framed to. Buckling interactions between elements in a frame is dependent on their joint connectivity. So the connections between, for example, a column and beam in a frame can either be pinned, semi-rigid or rigid.

Pinned connections, there is very low buckling interactivity between the various individual members that make up the whole structure. Semi-rigid, we can say that there is some interactivity that will occur between buckling of the various individual elements and how this will affect the overall buckling of the overall frame. Rigid connections, this is when you have, for example, fully moment connection between the beam and the column. Then you will have significant interactivity between the buckling of the various individual members that make up the whole frame. Consequently, in rigidly jointed frame, it makes sense to assess the stability of the entire frame to evaluate the critical load of one or two members that are parts of a larger framework.

An example of a side sway prevented frame is a brace frame, so when you have diagonally tension members or that acting compression as well. In such frames, the top end of each column is restrained elastically by the beam it is rigidly framed to. Therefore, buckling of the column is not just a function of its own stiffness, but the stiffness of the beam it is connected to. The beam stiffness can either be infinitely stiff or infinitely flexible, as these represent the upper and lower boundary of the stiffness of the beam.

So you can either have a very stiff beam that is connected to the column or a beam that is not stiff that is also connected to the top of the column. When the beam is infinitely stiff, it must maintain its straightness, whilst deformations of the frame take place. So it will not bend. It will maintain its straightness when the overall frame bends. Thus, columns behave as if they have a fixed end on either side. So the figure on the right hand side illustrates the buckling or the deformed shape of the overall frame for an infinitely stiff beam against a beam that its stiffness more or less is equal to zero.

You can see on the left hand side figure, the beam at the top, because we are assuming that it is infinitely stiff, it remains straight, and therefore the columns, we can think about them as if they are fixed at both at their bottom and top. However, the figure on the right hand side is where we are assuming that the stiffness of the beam is more or less equal to zero. That means we can think more or less about it that the column is fixed at its bottom and free at its top.

And this is why we can see that the critical buckling load for the case when the beam is infinitely stiff is much more higher than that when the beam is infinitely going to equal to zero, infinitely small. So concerning the case where the stiffness of the beam is assumed to be zero, i.e. the case on the right hand side, top ends of the columns will then behave as if they were pinned. In actual structures, the stiffness of the beam is somewhere between the upper and lower boundaries.

So in real structures, the connectivity between the top of the column and the beam is somewhere between an infinitely stiff beam and a beam where its stiffness is more or less equal to zero. The other type of frames are where side sway are permitted to occur. Concerning side sway-permitted frames and assuming that the beam is infinitely stiff, then the top ends of columns translations will be allowed. However, rotations will not be permitted. Therefore, each column critical load will be equivalent to the Oler load of a column pinned at both ends.

Meanwhile, for infinitely flexible beam stiffness, i.e. the stiffness is more or less equal to zero, rotations as well as translations at the top ends of the columns will be permitted. So at the top of the column where the column is connected to the beam, the column is allowed to rotate in a side sway-permitted frame. And therefore, the lateral deflections will be much more higher than frames where side sway movements are not permitted. So for example, frames where there is a diagonal bracing elements that resist the sway of the frame.

Therefore, each column inside the frame will behave as if it is a cantilever column. So in these frames, each column can be thought of as a cantilever column. So fixed at the base and free to move at the top. And again, we can investigate the effect of the stiffness of the beam by considering two frames. One frame where we are assuming that the stiffness of the beam is infinitely large. Another frame where we are assessing whereby the stiffness of the beam is infinitely small. And we can see that the critical buckling load for the case where the stiffness of the beam is infinitely large.

The buckling load is much more higher than that of the same frame where we assume that the stiffness of the beam is infinitely small.

Want the rest of Structural Stability of Lateral Forces?

Get the full course syllabus and fees.

The full course is paid (₹40,000). We'll send the syllabus and call you back within one working day.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Full course · paid

Unlock the full Structural Stability of Lateral Forces course

The remaining 63 lessons, mentor-reviewed projects and a certificate come with the paid course (₹40,000). Leave your details: we'll send the syllabus and fees and call you back.

Get the syllabus and fees

A counsellor calls you back within one working day.

By submitting you agree to our Terms and Privacy Policy.

Grow by Skill-Lync · free lesson

Start watching

Free, no payment. Leave your details once and every free lesson on Grow plays straight away. A Skill-Lync counsellor may call you about the full Structural Stability of Lateral Forces course.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.