← Previous lessonFree lesson 6 of 6 · lesson 20 of 57

Unlock all 57 lessons of Frontiers in Biomedical EngineeringFull course ₹40,000 · paid

Price & syllabus
Free lesson · 24 min · no payment

Biomedical Data Acquisition, Sensors, Alarms and Instrument Characteristics

A free lesson from Skill-Lync's Frontiers in Biomedical Engineering course, on Grow by Skill-Lync · Last updated 16 Nov 2026 · Session: “Module 7 Session 3 - Introduction to Biomedical Instrumentation”

What will you learn in this free Frontiers in Biomedical Engineering lesson?

The instructor draws the block diagram of a biomedical acquisition system, from sensors and amplifiers through filtering to display for the doctor. It compares active and passive sensors, lists sensor selection factors such as linearity and response time, explains alarm design with heart rate limits, and ends on static and dynamic characteristics.

  • Stages of a biomedical data acquisition system
  • Active versus passive sensors
  • Sensor selection factors: stability, linearity, response
  • Static and dynamic characteristics of instruments

What comes after lesson 20?

Later in Skill-Lync's Frontiers in Biomedical Engineering course (paid): lesson 21, Module 7 Session 4 - Introduction to Biomedical Instrumentation; lesson 22, Module 8 Session 1 - Bioelectric Signals; lesson 23, Module 8 Session 2 - Bioelectric Signals. The full course has 57 lessons (20 h 27 min of video); see the course overview or its price and syllabus.

Lesson transcript

Machine transcript of the lesson audio (lightly cleaned). Technical terms may contain errors; the video is the reference.

Now let us see what all the components of an biomedical instrumentation system. So the basic general block diagram of an biomedical acquisition and interpretation system is, we have the subject on whom the measurements are going to be carried out, the sensors are placed on the subject, and the data is going to be acquired. This data, as I already mentioned, is going to be corrupted with a lot of noise, and these all are very raw in form, and this data needs to be preprocessed. So preprocessing can be amplification, it can be filtering, the preprocessing stage consists of amplification, filtering, as these signals are very raw in nature, they are corrupted with a lot of noises, these noises are required to be removed, and then a clean and a good quality signals are going to be presented.

So basically we carry out some kind of an amplification, and these amplified signals are going to be filtered from all the unwanted noises, and then it is going to be given it for further analysis. Now from this processed signals, information is going to be extracted. So from this information, the data is going to be presented to the doctor or to a consulting person, and now the interpretation is going to happen based on the physiological signals acquired and then displayed. Now the interpretation takes place, whether the conditions are normal or abnormal conditions.

Then the interpretation is a very very important stage based on the acquired data and the processed signals. It should be of good diagnostic quality for a doctor to interpret and then give his opinion on the person's health condition. Now let's further break down this generic biomedical data acquisition system into a more detailed data acquisition system. Here we again have the patient, we have the transducers. The transducers and sensors are going to be put onto the subject or the patient, and then there is going to be an amplifier.

These are the amplifiers which does the pre-amplification of the signals to a desired signal level, so that they can be amplified further and then filtered. Basically at the front end, we need to have an isolation stage, because the patients are likely to get some kind of a leakage current, which will likely to flow back to the patient and induce a micro and a macro shock. So we need to isolate these electronics from the patient, and then we should avoid the flow of any current to the patient, so that the patient or the operator or the doctor should not get some kind of a macro or a micro shock.

So there should be an isolation amplifier. Isolations are achieved by multiple techniques, which we will be covering at the later stage. So isolation amplifier forms the front end, and then we have the further amplification, and the amplification and filtering is going to be done. Here the amplification is done in such a way that the data can be digitized to a level which can be easily interpreted, and the filtering is going to restrict the signal to the band of frequencies what is of interest to us. Then we have the analog to digital converters.

The advantage of analog to digital converters is we can manipulate further the data in the digital domain. We can do further processing. Noise removal techniques of higher orders can be implemented here, and we can use digital filtering techniques to remove artifacts like motion artifacts or baseline wonders. Much complicated algorithms can be applied. And also when we have the data in the digital domain, it is very advantageous for you to do a lot of pattern recognition techniques or artificial intelligence techniques to detect any kind of an abnormal events or some components which is of very much of interest.

And from the data, analysis of further is going to be done where the features of the data is going to be extracted. Any kind of features which are going to be recognized or to be extracted will be carried out. And then we are going to do some kind of a pattern recognition or classification or any kind of an automatic diagnostic decisions which are going to be required. And these are going to be presented to the doctor. And these will be helpful for the doctor to take any kind of a decision.

All these analysis are going to be carried out based on the previous history, what has been stored, and then the events which are recorded, and also based on the previous history of the patient, and also in the previous experiences of treating a similar patient. So if you see here, the block is now restricted to signal data acquisition which forms from the transducer to the ADC. And then we have the signal processing block where we are going to do digital filtering and then do some kind of an detection of events and components.

Then further we have the signal analysis which we are going to do the analysis for any events and future extraction will be done. And then pattern recognition and classification and any diagnostic decisions for any automatic classification can be done here. And this data is going to be presented to the doctor for any kind of an treatment or any kind of an diagnostic information. And the doctor will find it very easy to carry out any interpretation on this data. Now let's further go more into the details of the generic block diagram of the biomedical data acquisition system.

So we have the measurement. The measurement is nothing but the biopotential signals or body temperature, blood pressure, you are trying to measure the heart rate or the pulse rate, respiration rate or it can be any other parameters like the blood flow which we are trying to measure. These are the measurements. And there are so many sensors and transducers which are going to be used to measure those measurements. And many of the sensors are going to be for each one of the physiological conditions we are going to have separate sensors or transducers.

And next is the signal conditioning and the isolation circuits. And the conditioned signals are going to be digitized and processed. And then it is going to be displayed. And also the data is going to be stored for further retrieval and then for further analysis. And also the data is going to be communicated to a remote places for any kind of an remote consultation, telemedicine or even analysis or for remote storage purposes. Also when these physiological signals go beyond some kind of limits, a predetermined limits, there is an alarm system which is being generated.

The alarms can be visual alarms or it can be an audible alarms. And also I was mentioning about the isolation. The isolation is to protect the patients from any macro or micro shocks. The isolations can be for both the signals and the power. And also the power can be operated from the mains or can be operated from a battery. This battery power supply also needs to be isolated so that there is no any kind of a shock to the patient or to the doctor who is operating on or who is going to be looking at the patient or recording any signals from the patient.

And one more important block is the feedback system. In case there is going to be any kind of a feedback which is going to be given in the form of a stimulus or it can be a visual and audible inputs to the patient. So the feedback is going to be automatically generated and there is an actuator which is going to deliver the feedback to the human system. And further again any variations in the physiological parameters are going to be again measured. And again this process continues.

So this is the complete block diagram of a human system. And for acquiring all this data and then processing, there is a centralized controller which is available. A very good powerful processor is available which is going to control and coordinate all these activities of data acquisition, displaying and generating alarms, storing the data, retrieval, communicating the data to a remote locations and also it is going to give some kind of a feedback to the user when an abnormal conditions are going to be there. And one more important function or feature which is to be added in this instrumentation system is the need for calibration.

Basically this calibration signal is going to see that whether all your signal conditioning circuitries are functioning as per the required specifications. So you give in calibration inputs at regular intervals and calibrate the equipment and then use them so that all your measurement values are measured correctly which can be calibrated using an calibration signals. Especially it is very very useful for getting a good diagnostic ECG or EEG signals or any physiological signals. So calibration is very very important and periodic calibration of the equipment is very very much mandatory in a physiological monitoring instrumentation systems.

Now let us take up the block of the measureant. What is this measureant is about? Basically measureant is nothing but it is the physiological body parameter or quantity under observation which is going to be measured. The measureant can be a biopotential signal like a ECG, EEG, PPG, EMG, body temperature, blood pressure, respiratory parameters, heart rate, pulse rate or blood flow. Basically it is very important for diagnosis and cure and monitoring and rehabilitation purposes. Basically the next block is the sensors and the transducers. The sensors and transducers basically they sense or detect the physiological parameters or input under observation which is of interest and they convert them into a suitable electrical form for measurement and recording.

Example some of the sensors or transducers are the thermistors, thermocouples for temperature measurements, piezoelectric or strain gauges for blood pressure measurements, they can be Doppler or ultrasound sensors for blood flow measurements or biopotential electrodes for recording of ECG, EEG and other physiological or biopotential signals. Basically the sensors can be either active sensors or they can be an passive sensors. What is this active sensors? The active sensors basically require external power for their operation which is called as an excitation signal. That signal will be modified by the sensor to produce an output signal.

Basically the active sensors sometimes are called as parametric sensors because their properties change in response to the external effect and these properties can be subsequently converted into an electrical signals. Next is the passive sensors. A passive sensor gives electrical output in response to External stimulus. Basically, they will not require any excitation or any energy source to function. They gather radiation that is emitted or reflected by the object or surrounding areas. Sometimes that is basically and reflected sunlight is the most common source of radiation measured by these passive sensors. Examples of passive sensors are film photography, IR sources, charge couple devices, radiometers, thermocouples, photodiodes, piezoelectric sensors. These are some of the passive sensors.

The next classification of sensors is the absolute and relative sensors. What is an absolute sensor? Basically, an absolute sensor detects a stimulus in reference to an absolute physical scale that is independent of the measurement condition. Example of an absolute sensor is a thermistor. Basically, a temperature sensitive resistor. Its electrical resistance is directly proportional to the temperature in either degree Celsius or in degree Kelvin. A relative sensor will produce a signal that relates to some kind of physical case. For example, a thermocouple. Here, we will be maintaining a hot junction and a cold junction. So, the temperature at the hot junction is going to be measured in relation to the temperature maintained at the cold junction.

Further, the sensors are also classified based on the material being used. They can be inorganic or organic sensors. Like inorganic materials, if they are used, they are classified as an inorganic sensors. Basically, based on the semiconductor conducting or based on the biological substance. In case they use an organic material, they are classified as an organic sensor. Also, based on the detection mechanism, the sensors are classified. It can be used for biological, chemical, electric, electromagnetic, heat, temperature, mechanical displacement, or radioactivity, radiation purposes. The sensors can be classified. Again, based on the phenomena of conversion, the sensors can be classified as physical sensors, chemical sensors, or biological sensors.

Like physical sensors are further classified into thermoelectric effect, photoelectric, photomagnetic, magnetoelectric, thermoelastic, photoelastic, thermo-optic methods. Chemical classifications like chemical classifications like chemical transformation, physical transformation, electrochemical process, spectroscopy, like biological conversion phenomena in case they are used, biochemical transformation, physical transformation, spectroscopy. These are some of the classification based on the physical phenomena. Again, the sensors can be classified based on the field of application. They can be based on for the application where it is going to be used. So, suppose if the sensors are used for agriculture purpose, they are classified as agricultural sensors, civil engineering and construction for structural monitoring, energy-related applications for energy and power, manufacturing, military applications, scientific instruments, automotive applications, domestic appliances, space applications, environmental applications, and it can be used for marine applications.

Like that, based on the field of applications, the sensors can be classified. We have seen the classification of sensors. Now, how do you select the sensors? What are the factors you should consider when we are going to select a sensor for a particular application? There may be a wide variety of sensors meant for measuring one physiological condition or a parameter or meant for sensing one physical measurements to be done. You will see that there will be many sensors available. What are the factors you should consider?

Basically, there are three factors which we need to consider. One is the environmental factors, economic factors, and the sensor characteristics. The environmental factors, what all we should consider is what is the temperature range we are looking at, what are its effects on humidity, corrosion, in case you are going to use it in some kind of corrosive liquid or corrosive environments. What is the size of the sensor we are looking at, how small it should be, how big it should be, what is the size it can be used in that location, and what all the protection mechanisms it is required.

Suppose the range is going to be over-ranged, what is the range protection we need to give in? Suppose it is going to be used in an electromagnetic environment, what all kind of interferences are going to be there? What all kind of electromagnetic clearances it needs to undergo, how much of power it is going to consume, what is the power requirement for it? Also, whether the sensor has got some kind of a self-test capability so that its function can be tested easily. Economic factors like how much costly it is, whether it is affordable, whether it is going to be available, whether these sensors will be available in the near future, what will be the lifetime of these sensors, which are all very, very critical factors, because this is going to decide your return on investment on the sensors.

And other sensor characteristics like sensitivity, what is the sensitivity of the sensor, what is the range it can operate on, what is the stability of the sensor, how repeatable will be the values when you are going to have multiple times the recording done on the same item or same measurement parameter, what is the linearity of the sensor, how much of error the sensor is going to add to your measurements, what is the response time of these sensors, what is the frequency response, like that we need to consider many factors before considering to choose a sensor for any particular applications.

The next block in the human instrument interface system is the signal conditioning portion. Basically, the signal conditioning is the output of the sensor as a transducer, which are required to be converted into a form suitable for measuring and then displaying it for the operator to look at the values. So, the following are the functions of the signal conditioner. Basically, it carries out amplification, it carries out noise filtering, it does a frequency response matching, it does signal isolation, it does power isolation, it has got protection circuits, and then it is going to give the condition signal to the display for the operator to have in a suitable form, so that he can interpret the data, so that the further action on the physiological parameters can be carried out.

So, for signal conditioning, the next stage is going to be the analog to digital conversion. The analog signals which have been conditioned will be given to the analog to digital converters. Basically, analog signals cannot be directly displayed on modern scopes because digital signals have got a lot of advantages where the manipulations of data is very easy, and handling of digital signals for storage and remote transmissions are quite useful. So, it is always necessary to convert the data into a digital format before it is being displayed or stored.

And also, the need for processing the data and digitally to remove the noises and other extraction of parameters such as the features, or if you are going to use some kind of techniques like artificial intelligence onto this data, or an expert system is likely to be used onto this, then the data has to be in digital domain. And while digitizing these signals, always we should ensure that we are going to follow some kind of an standard rules, which are like the Nyquist sampling theorem is to be followed, so that these signals are going to be reproduced very well post the digitization process.

So, we need to adhere to the Nyquist sampling theorem, and there are various methods of analog to digital conversion, and the most common being the successive approximation. Successive approximation ADC is a very commonly used ADC, and flash ADC is also used. Again, based on the processor what it supports, we can use any type of an analog to digital conversion for converting the data into a digital format. Post the analog to digital conversion, next is the processing stage. Now, the analog signals which are processed, and then conditioned is going to be now processed for any kind of a future extraction or for noise removals.

Now, digital processing is further carried out on these signals. What all the processing which we do is the noise removal, basically the baseline wander, tremors, and the motion artifact. Again, we do a lot of computations on the signals, like for example, on the ECG signal, we calculate the heart rate. If it is a PPG signal, we calculate the pulse rate. And from the ECG signals acquired, if there are some kind of an abnormalities being seen, we can use these techniques of pattern recognition to calculate various types of arrhythmias.

And also, heart rate variability and its parameters can be computed and displayed. And real-time signal processing is very, very important. And computation of all the parameters in real-time is very important. So, it is always necessary to do processing using a digital signal processor. If there are going to be any delay in reporting any kind of an abnormality on arrhythmia, it will lead into some kind of a dangerous situation for the patient. So, there is no delay which is to be reported. So, the real-time processing is very, very critical in this kind of a system.

Post-processing, the data is to be displayed on an output device. So, the display provides the visual or graphical representation of the input signals. It can be physiological or any parameters that has been measured, which are where under observation. The output also can be represented in a 3D format. Otherwise, most commonly, the data is going to be given on a hard copy in the form of an printouts. And also, the display can be a CRO or a storage oscilloscope. It can be an LCD or it can be on computer monitors.

Or an hard copy can be taken on the printers. The other component in the system is the alarm system. The basic alarm system consists of an audible or a visual output, which is generated when there is any kind of a parameter which is under observation or monitoring, goes above or below the safe range of values. For example, if you take the heart rate, in case of tachycardia, in case the heart, you can set the values. If the heart rate goes above 140 beats per minute, we can generate alarms.

Or it can be an bradic idea where the heart rate goes less than 40 beats per minute. Or in case the blood pressure values are going out of range, whether a low blood pressure is reported or a very high blood pressure is reported, alarms can be generated. So, alarms are of different types. Alarms can be audible or visual. Audible alarm system. Like by the use of the piezoelectric buses, visual alarms can be in the form of change of a screen color where the parameters are being displayed or some kind of an flashing or a blinking indication of the heart rate value with the changed colors, maybe in a red color or something like that can be given so that it is visually seen and the person can be immediately attended to.

The next in the MAN instrumentation system is the data storage and retrieval. Basically, storage of the process data is very, very important because all the physiological and physical parameters are stored in a medium. Very commonly nowadays, the flash drives are very commonly used or the solid state devices are very commonly used. Earlier, tape drives were used and hard disks were also used. Now, for quicker recovery and then for easier access, the solid state devices are very popular. Basically, storage is done to study the patient's history of its medical conditions.

Also, these data are stored for any remote diagnosis requirements. Also, we can see from the earlier data stored what was the analysis of the disease earlier and what were the treatments given earlier and what is the progress of the treatment and whether there is any need for change in the medication or any change in the treatment procedure itself is required. So, that is how this data is stored and retrieved. Also, this data is going to be very useful for studying any kind of a particular disease and then it can be stored continuously and then we can see if any kind of an artificial intelligence can be used on this data.

And then we can try to see how the disease is now progressing or whether the person's recovery is happening in a full manner or whether the disease is not responding to any kind of an medication. Such kind of an analysis can be carried out using this data which has been stored in the hard disk. The next block is the data communications. Basically, data communication can be for storage into a centralized storage databases or into a storage service which are placed in a centralized location. Or this data can be transmitted for remote consultation to an expert doctor for telemedicine applications.

This again, the data communication can be for short range communication or it can be for long range communication and also we should ensure that when the data is going to be communicated, the data has to be encrypted, the security of the data has to be maintained, the data at the remote location, the doctor is supposed to maintain the data confidentiality and secrecy and there should not be any chance for any manipulation of the data of the patient's data which has been sent to the remote location.

And in case it is being stored at the remote locations, authentication should be there for the person to only read the data, not to manipulate the data at any levels. Now, let's take up the next topic which is on the characteristics of instruments. So, what are the characteristics of instruments? Basically, the performance of an instrument is described by means of an quantitative qualities termed as characteristics. These characteristics can be static and dynamic characteristics. So, what are the static and dynamic characteristics? What is the static characteristics?

These characteristics pertain to a system where the quantities to be measured are constant. Or they vary very slowly with time. For example, the temperature. Even if you take the temperature of a human body, the variations are very very slow with respect to time. What are the dynamic characteristics? Dynamic characteristics are performance criteria is based on the dynamic relationship. They, in fact, vary very rapidly with the quantities. Example is the heart rate, which is a highly dynamic characteristics. They vary very fast with respect to time. And the parameters are going to change based on the human condition.

And also, with respect to time, they are very dynamically changing. And the parameters, if you see, they vary from one particular time to another time, like in the person's resting condition, or walking, or when he is running. The heart rate is going to vary very dynamically when compared to any other parameters. The heart rate is going to vary from the location to another time to another time. The heart rate is going to vary from the same time, like in the person's resting condition. The heart rate is going to vary from the same time.

Want the rest of Frontiers in Biomedical Engineering?

Get the full course syllabus and fees.

The full course is paid (₹40,000). We'll send the syllabus and call you back within one working day.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Full course · paid

Unlock the full Frontiers in Biomedical Engineering course

The remaining 51 lessons, mentor-reviewed projects and a certificate come with the paid course (₹40,000). Leave your details: we'll send the syllabus and fees and call you back.

Get the syllabus and fees

A counsellor calls you back within one working day.

By submitting you agree to our Terms and Privacy Policy.

Grow by Skill-Lync · free lesson

Start watching

Free, no payment. Leave your details once and every free lesson on Grow plays straight away. A Skill-Lync counsellor may call you about the full Frontiers in Biomedical Engineering course.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.