Converter Efficiency, Buck Converter Duty Cycle and Ripple Sizing
A free lesson from Skill-Lync's Design Concepts of Power Electronic Converters for Industries course, on Grow by Skill-Lync · Last updated 16 Nov 2026 · Session: “Week 1 Session 3”
What will you learn in this free Design Concepts of Power Electronic Converters for Industries lesson?
Defines converter efficiency and power loss and why 97 to 98 percent efficiency matters. Then derives the buck converter output from PWM duty cycle using energy conservation, and covers ripple in inductors and capacitors for sizing DC link parts.
- Efficiency and power loss equations
- PWM duty cycle controlling a switch
- Buck converter output voltage and current relation
- Ripple limits for sizing inductors and capacitors
What comes after lesson 3?
Later in Skill-Lync's Design Concepts of Power Electronic Converters for Industries course (paid): lesson 4, Week 1 Session 4; lesson 5, Week 2 Session 1; lesson 6, Week 2 Session 2. The full course has 55 lessons (24 h 51 min of video); see the course overview or its price and syllabus.
Lesson transcript
Machine transcript of the lesson audio (lightly cleaned). Technical terms may contain errors; the video is the reference.
Hi everyone, welcome back. So, next we will continue on same week 1 on power electronics design. So, as we looked initially, one of the major objectives of the power electronics is to achieve the maximum efficiency. So, the efficiency is pretty simple again. We are trying to derive the efficiency based upon certain output and input power. So, efficiency is a function of output divided by input power where you can generate a certain output. So, taking in the power loss, which is the difference between your input minus output, and then you can regenerate those equations.
So, power loss is basically P output times 1 divided by efficiency minus 1. The major goal here is to achieve maximum efficiency, which also results into lower power loss and smaller size of the converter. And the lower power loss would basically correspond to lower temperature that's generated and very high performance. So, this is very important when selecting and designing your power converters and the power switches as well. Generally, the power converters are loss limited. So, you can provide or convert a certain kilowatts or hundreds of kilowatts of energy into another form of energy by incurring a very small amount of losses.
So, that's where I said the power converters can be designed to achieve an efficiency of 97-98%. I mean, that's really amazing, right? You can convert 100 kilowatts into 90 kilowatts with just losing 2 kilowatts of energy, which is, again, not feasible with any sort of other systems because you are limited on the efficiency. So, high efficiency is the key. We are converting an input power to an output power. And the efficiency and losses, they vary, again, with respect to the output power. So, I just plotted the same equation on the other slide.
The P output divided by P loss is a function of efficiency. So, as our P out by P loss increases, our efficiency also increases. This is basically meaning if we are able to contain our power losses to a smaller number, we will be able to generate higher power output. So, moving to the next slide here, let's take an example for a DC-DC converter and see how all of the different numbers play out. So, looking into an input source here, so 200 volts that's available on to the input of DC.
And we are trying to convert this into a 100-volt output. So, right now, again, I have introduced different converters. And then here you can see we are stepping down this voltage from 200 volts to 100 volts. So, this is a step-down converter. Really, right? And we'll see how to generate it. Again, you can use different things to provide or generate a 100-volt output. And that's what I'll show you. And then we'll see why to use power electronics. You can use different things over here. So, and I'm using a 10-ohm load here.
So, the current that's flowing into this is 10 amps based upon 100 volts. And we are designing a very low-power 1-kilowatt converter. So, how to realize this converter? Let's look into the first method. Maybe using a dissipative sort of strategy or using a resistor voltage divider. So, you can put a resistor over here and you have got input voltage, one resistance over here. This is the load resistance and use the voltage divider circuit to generate 100 volts. So, what would we do in this particular method?
We want the voltage drop across this to be 100 volts. So, if there is 100 volts drop here, naturally the voltage that's available here would be 100 volts. But what happens here, if we are flowing 10 amps into the circuit at 200 volts, the input power is 2 kilowatts. The output that we get is 1 kilowatt. And we are losing about 1 kilowatt. So, that's the thing you see. If we use a voltage divider sort of circuitry, we are using about 50%. So, resistors, they burn a lot of energy and generate heat and this is not preferred for power electronics.
So, that's not used. Let's look into another topology and then see if that would be preferred. So, using a series pass regulator. So, now we have a 200 volt input. We are using a linear amplifier where we generate a reference of 100 volts and try to control and turn on this amplifier whenever there is a feedback available. So, the amplifier here is also drawing that 100 volts because it is working on a PWM with 50% duty cycle. So, this is also not preferred because we are losing about 1 kilowatt of power in the system where there is just 1 kilowatt more available.
So, the passive devices have to be selected properly based upon their forward voltage drop and switching characteristics. So, certainly you can use a passive device which has a lower voltage drop and be able to control the switching such a way that you can achieve a higher sort of voltage output. And that is where the power electronics comes into play where you are operating it with a certain PWM input which is operating so fast. So, we are losing very low. So, we are only losing about a few percentage, not 50% over here.
Okay. So, again, if we extend that topology and just use a switch. So, use of a single pole double throw switch. So, using a single pole double throw switch results into a pulsating output which depends upon the turn on and turn off time of the switch. And we will look into the picture next where the output voltage is basically the duty cycle of that switch multiplied by the input voltage. And this basically means that longer the switch is on, higher the output voltage we have got.
So, to achieve 100 volts from 200 volts, you basically want this duty cycle to be at 50%. Right. So, you get the input voltage. So, we have got 200 volts over here, 100 volts over here, and I am using basically a single pole double throw switch which is put over here in case you want the output to flow and then connect it over here if you don't want the output to be flowing to the 200 volts. So, what will happen in this case, when the switch is on or connected to the position 1, you would basically get the same voltage as the input.
So, VG. When switch is connected to the 2, there is no potential difference at all. So, that's going to be 0. And then, again, it will be VG. So, if we look on an average voltage, which is available, it will be D times of VG, where D is the duty cycle on how that switch is controlled. So, if the switch is at 50% control, then we will be generating that output at 100 volts. So, this on time here is referred as a D times of TS, and then the off time is 1 minus D times of TS, where TS is the sampling time or switching time.
Okay. And, again, the output here will relate depending upon the duty cycle. The duty cycle is between 0 and 1. So, you can basically provide an output which is equal to the input at the most. or lower than the input. The TS corresponds to the switching period, and FS corresponds to the switching frequency, which is defined as 1 divided by TS. So, again, higher the switching frequency, the higher the possibility that you can generate a very good waveform on the output. So, all of these above parameters can be controlled to achieve the required voltage output.
And, this method here is limited to the switching frequency, because there is going to be significant ripples that's present in the output. So, here, we are switching at a certain rate where you can see the waveform is switching between plus 200 and 0, plus 200 and 0. So, higher the switching frequency, there is going to be ripples like this. That's going to be between the plus 200 and 0. So, there is a lot of ripples here. The output here can be taken in from this waveform.
And, if we apply and then try to get the output voltage, the output is basically an average value. So, 1 by T and looking at it into instantaneous voltage. So, that results into a D times of VG. Okay. So, let's see if we add a low-pass filter to it, then what happens? Because we did talk that there will be higher ripples in the system if we just use the switching or the switch at a certain frequency. So, now, I have implemented an LC low-pass filter in the system where the switch is again between 1 and 2 and then we are...
In the output that goes to the VT. So for removing of the switching harmonics, the LC filters are added, which is basically, now we can consider it as a lossless circuit for now, but certainly there is nothing as an ideal lossless circuit. But for analysis purposes and understanding, let's assume that these two do not have any losses at all. So there is typically an ESR within the capacitor and also a resistance within the inductor coils. The coil resistance here and the capacitor resistance, they contribute to the losses and take out a certain fraction of efficiency.
But now for a lossless system, for a 2kW input, you are basically generating a 2kW output because the loss is really small. So what's the benefit of including the LC filter? You can increase the overall efficiency and also reduce the peak-to-peak ripple because now it's smooth and then you can basically generate it. And you can choose the cutoff frequency for the filter, which is smaller than the switching frequency. So it is going to filter out those switching frequency noise or our output and make it a smooth frequency or our DC output.
And this converter is basically the buck converter. So we have seen how we step from a resistor divider to a regulator circuit to a switch and then using passive filters to get a buck converter. So this is how the technology has evolved and then we implement different power electronic systems. So again, this is not a very good or ideal system without controls. So in the next slide, we introduce some controls in it and see how this would work. There is VG, which is the input power.
We have got a MOSFET over here, which is the switch. And then we got LC filter. We have got a diode. So it's preventing the current flowing in into the direction. And it also lets the inductor current flow or a free wheel into the diode. And we are taking in the feedback here from the output. So there is typically a current sensor that's used. We are taking in. We are controlling and then getting that sensor gain of that fed that is based upon the voltage. So the voltage feedback is over here.
The input voltage is over here. The error is generated. And then we use a compensator and PI gain. So we are able to control this to generate a controlled VC sort of waveform, which can be fed into the pulse width modulator or PWM modulator, which can drive this MOSFET. So the delta here, the output from PWM is going to look like this, which is going to vary between DTS and TS based upon the difference between the reference and the actual value. So how the signal error evolves and what the difference is, the switches are going to be on and off at a certain timing.
So we can basically control the output at a forward rate. So we reviewed earlier that the controls are integral part of an efficient and stable power converter. So it's very important to use the controls in a closed loop to be able to derive your output. Certain applications don't need to be complicated where you don't really need a controller. So that's okay. You can generate an input relationship without using any controls or complex microcontrollers. Yes, a lot of systems, about 70%, they need very good accuracy. So you need to be using a controls here.
So expanding a little bit on the previous slide here, the controls implementation, it does demand using of some analog or registered controls for power electronics. So we will review in the upcoming modules and look at the devices that it's used and in the coming week two and week three and see how different switching methods and the PWM strategies are used as well. So that's all on the power electronics devices. Now I change the gears and we will dive into steady state analysis. So steady state analysis is, as I mentioned before, it's one of the circuit theories that's used to be able to use the equations and derive your circuit parameters.
And those parameters are used in sizing the power electronic converter. So even though, again, I have mentioned you need to know certain basics, I will quickly go through some of the basics of the circuit theory and then we'll go into an example and then see how to use and be able to design a controller. So KCL, KVL and periodic steady state, these will be the three different theories which we will go through. And these are pretty basic. So again, I did not understand a lot of time on this.
And then we will go into some of the complex. With KCL, which is also known as Kirchhoff's current law, we are looking at a node where the current is flowing in and the theory is that the sum of the current at that particular node is equals to zero. So sigma i, j is equals to zero for over a period of time. So those currents would be coming in or going out. It does not matter. You can add them and then that should result into a zero.
This theory applies to the instantaneous values and also to the average values. So it can be derived from the law of conservation of charges that, okay, this is the total current or sigma i is going to be zero. So this is the time domain. And then you can have a discrete domain as well. The law is always true. Next, looking into KVL, we have got a similar method over here. Here, if I have a bunch of different voltage sources connected to a certain node, the overall sum of the voltage is going to be zero.
So that's the resultant of the voltage in this particular node is going to be zero. And the sigma VK here defines the voltage, which would be zero. Next, the periodic steady state, which is time importance in power electronics. Here, we will make, look at the circuit and make certain assumptions on how a signal or a time varying model will perform. And this is important to implement a variable flow models or average value models. So the system returns to the starting or same point at each of the node or cycle.
The beginning of the node matches the end. So, well, and in short, if I say in a periodic steady state, if we consider an example where the voltage across an inductor is LDI DT. So, again, looking into an average space here, I want to do a periodic analysis of the voltage, which is, so these brackets in here represents the average value. The DI DT, the change over time, is considered as zero. So, for an average value model, we will look into and then not look and we'll see that the voltage is going to be zero.
For an instantaneous time varying models, the DI DT cannot be ignored. But for an average value models, we do ignore the time varying terms and then some of the differential terms. So, therefore, the inductor average voltage across an inductor, which is zero, that means that the DI DT across an inductor is basically zero. So, looking at the difference of the currents, we can equate it to zero. Similarly, the voltage across the capacitor, average voltage is also zero. So, average of DVC by DT is equals to zero.
So, we'll consider an example in the next slide and then see how that comes through. The steady state analysis, here we're looking into a circuit which has an AC source, which is, say, V sine omega T. And then a diode, which is basically allowing the current to flow into one direction and basically acting as a kind of a rectifier. We've got an inductor where energy is stored and then we've got a resistive load. This is a very simple rectifier. Again, it's only doing an half wave.
So, a filter should be first added to a circuit to smoothen the ripple. So, that's how an inductor is used to be able to smoothen some of the ripple. And next, we will look into the equations and see how to do the analysis in a periodic steady state or a PSS model. So, to analyze the converter in a PSS, we need to understand the following equations. The average KCL, the sum of the currents across a node is zero. The KVL average, sum of the voltage across a node is zero.
And we know that the voltage across an inductor is LDI dt. For a periodic steady state, we assume that the DI dt is zero. That is, there is no change of voltage across the inductor. And similarly, the current across capacitor can be given as I equals to C dV by dt. So, that's the current across the capacitor. And in periodic steady state, we assume, again, the dV by dt is zero. So, I equals to C dV by dt, and then there is basically no change. So, as the current across the capacitor is zero, we consider then dV by dt equals to zero.
So, if the circuit is lossless, the input and output are basically same. So, again, in the previous example that we considered, we have added to a switch to design a buck converter, an LC low-pass filter, which is smoothening the ripples that's generated. And that will be all summed down to zero. The steady state analysis, again, continuing upon the previous slide, the power conversion here, let's consider the DC-DC converter where output voltage here is pulsating. And then change. With the duty cycle. So we've got a voltage source where the voltage is greater than zero. It is filtered. So the voltage that we have available on at this point over here across this particular point is filtered using the capacitor. So it's more stable. We can handle some transients. And we've got a switch here, which is changing between these two states. And we've got an LC filter, which is filtering that signal out. So we are generating a certain DC.
Maybe another DC voltage waveform, which is of different magnitude. And the voltage, the V2 is the output voltage. So the Q of T indicates the switch on and off. So we are switching from one to zero, one to zero in the switch. The PWM duty cycle is basically controlling the switch. And then we are generating an output. The voltage is also going to vary based upon that. Whenever the switch is on again, we are seeing the same voltage appear. V2 is equals to V1. So we are seeing a voltage V1 and then zero, then V1.
So the overall average voltage is basically duty cycle times of V1, right? And then where the D is again, the duty ratio that's defined. So if we look into the circuit again, this is basically a buck converter where we are going to prove that the energy is conserved inside the buck converter. And from the law of conservation of energy, it does not matter which circuit you are operating or working with. The total energy has to be conserved. So there are certain assumptions that are being done for simplicity again, because I don't want to dive into non-ideal conditions and then make everything so complex. For now, our goal is to just understand these concepts and you can always expand them for non-ideal cases.
So as we know, the output voltage is basically duty cycle times of input voltage. So this converter that we looked in the previous slide here, which is switch, filter and voltage, this is basically a buck converter, right? So this is the buck converter. And similarly, the output current is inversely proportional to the duty cycle, because if we are generating a voltage, which is stepped down, the current has to be stepped up because we are at the end, we are going to conserve the overall energy. So let's see how to derive those. So for our calculation purposes, let's assume that the L and Cs are very big. So if L and Cs are very big, the voltage across the capacitor VCT is, as a function of time, is basically VC.
The current into the inductor is IL of T, which is equals to IL. In periodic study state, we have already looked into the voltage across that inductor, the LDI DT is basically zero. So if we, again, try to derive the equations from the previous slide, the voltage across the inductor here is, the voltage VL is basically V1 minus V2, right? And the current across the capacitor would be IL and I2 and IC. So IC is IL minus I2. So we will be using those two. So whenever the switch is on, if the voltage is V1 minus V2 times of DT. So that's the on time. Whenever it is off, the switch is off, the voltage across the inductor is going to be minus V2 because there is no V1.
So it's zero minus V2. So again, if we solve this equation, it's basically saying that DV1T minus V2 is equals to zero. So the V2 output voltage is basically D times of V1. So this proves that the voltage across the output is a function of DT cycle, which is D times of V1. And considering the currents, the current, overall of the current into the capacitor, the steady state is zero. So I1 is basically equals to I2. So the current across the capacitor is I1 minus I2 times of DT.
This is the on current. And again, if we subtract this, the I1 is basically D times of I2. So if I2 is our output and I1 is input, so output current is basically inversely proportional to the input. So if we multiply these two equations here, V2 and I2, we'll see that V2 times of I2 is equals to V1 times of I1 because D and Ds, they get cancelled. So that basically concludes that the energy is conserved into the circuit and that is always true from the law.
Okay. Looking into the following, again, a similar circuit here, we are implementing the buck converter with voltage input, voltage output and using a capacitor to filter and using an LC filter. The switch implementation here is, again, a buck converter. And the buck converter here is also known as a direct converter. So for a direct converter, it basically means in one switch state, there is a DC path that exists between the input and output. So when the switch is on, then we know that the DC current is going to flow or DC voltage is going to exist on the output.
And similarly, when the switch is off, there is going to be the voltage across the output, which is going to be zero. So if we change the location of source and load, then the switch equations are going to be changed. So kind of doing a similar analysis as we have done before. The voltage across inductor is zero. The V1 minus V2 into 1 minus DT plus V1 DT equals to zero. This is considering the location of the source and load being changed. So output here is basically V1 divided by 1 minus D.
So again, the output here is going to change as the duty cycle changes. So if duty cycle was 0.1, you can see the output here is V1 divided by 0.9. So output here is higher than the input. So just by changing the equations and how this operates and location of the switch, we are able to generate a different topology. Now we are able to increase the voltage with the duty cycle. So, I mean, this is now a boost converter where you can get higher voltage based upon a given input voltage.
So this is basically the switch implementation. We are changing the way the switch is connected. And by conversion of power or energy, we know that if V2 is this, then I2 is supposed to be 1 minus D into I1. Because when you multiply V2 and I2, it should be equals to V1 into I1. So again, there is really no need to derive all the periodic steady state. You can use the law of conservation of energy or power into this. So kind of summary here and how to design and size your filter.
The ripple components and filter sizing, the selection of the filter component will depend upon the ripple and the frequency which was ignored previously. So right now for the equations, we have assumed that our inductors and capacitors are huge. So since the inductors and capacitors are huge, we did not consider them to be very impacting to our equations. But in an ideal scenario, again, that's not the case. We are, we'd have to size our filter such that they can be working and filtering down to a certain frequency ranges.
So we'll have to calculate those ripple components and how to get those values. So let's approximately calculate the ripple components. In order to eliminate the second order effects, there are certain assumptions that are made. So the average or delta peak to peak inductor current is zero. That's assuming again that the inductor is basically going to carry all the ripple. So there are two different assumptions that's done. One is considering that all the ripple goes into the inductor or all the ripple goes into the capacitor. So if we consider that the all ripple goes into the capacitor, then the delta Ipp is basically zero.
There is no peak to peak current ripple in the inductor because we are saying that the whole energy here in this particular circuit, the current is going to come like this. So if I highlight and then drive, so again, the current is going to be going from this particular load. It will go into the switch. When the switch is on, the current will go into the capacitor and it dives into the load and the capacitor, right? So if we consider that all of the ripple components, so the output over here is going to be a certain sort of ripples on the top of the DC waveform.
So if this is our DC waveform and it's going to have some sort of ripples in here. So there is going to be a plus or minus 2 amps or so, and we are saying that the whole current is being absorbed by the capacitor. So this does not see any sort of ripple. Similarly, the voltage is considered here as zero. So we are assuming that the whole voltage ripple is absorbed by the inductor itself. So that's how we size and drive this particular filter. Okay, so let me get rid of these things on the slides.
So the voltage across the capacitor is zero. So all the voltage ripple goes into the inductor. Those are the assumptions that we make. So again, example, the boost converter here. So we talked that for a boost converter, you would have to see that the switching here, the switch position is changed. So this is disconnected over here. Now the voltage across the input when the switch is open will go directly into the load. When the switch is closed, the current is going to freeway into the diode and into the switch.
So this is the ratio. And we are taking in the energy stored inside the inductor to drive the power to the load. So that's assuming the L tends to infinity, then the inductance is very huge. So we can consider a very simple model here that we have got a current source, which has a capacitor and then the voltage. And that is how we will derive the capacitor sizing. And we will do similar study for the inductor sizing as well. So assuming that the L is tending to infinity, so it's a big inductor.
So this is acting as a current source really at this point. So that's the current source, which is feeding into the capacitor. We are assuming that the diode is conducting here, right? So that's basically the current source, which is feeding into this, and that's getting the V2. So far, we have neglected all the ripple components, and we assumed a very big passive filter for demonstrating theory. So that was done, so you can understand how the voltage input and output relations look like. But in real application, we need to also size the inductors and capacitors.
So let's look into a realistic implementation where the capacitor has to be sized properly to meet a certain voltage ripple. And we will see the ripples in the voltage and current waveforms and then also evaluate the ripple voltage across capacitor. And then we can model the rest of the circuit as a current source. So that's what we have done. We have modeled that as a current source. So we've got current source and then capacitor and voltage. If we look into the current, it is basically going to change depending on the duty cycle and switch between a minus certain value to a plus certain value here.
So the actual waveform here is going to be different. This is the waveform of the current when the switch is on, it's carrying. When the switch is off, there is zero current. This is the typical waveform without any sort of filtering. Once we add the inductor in here, there is going to be slope like this. It's not a flat one because the di dt is going to impact. So there is going to be di dt. So it's going to do this followed by this. So there is going to be, let me draw that.
So there will be a waveform which will be observed like this. And this magnitude here is referred as the peak-to-peak current ripple. So this ripple here is basically one of the design criterias that designers use to size their inductors. Because if we look into the voltage across inductor, it is L di by dt. And we are trying to minimize the voltage and current ripples across the devices. So the voltage ripple across capacitor and current ripple. So on a time scale, this can be expressed as L into delta i by delta t.
So the delta i is basically described as V into delta t by L. So delta i is a function V into delta t divided by L. So the larger the inductor that we size, the lower the ripple is going to be. So that does not mean you can size an inductor which can be a big enough like 1 mH or something which can sustain and then give you a ripple to be lower because it's going to be a bulky inductor in that case. Design in the inductor, I think there is also a ripple which is considered in mind to be designing of a decent size of 5% or typically a 10% ripple is used as a design target.
So this is typically used. So you can design your converter with a decent enough inductor which is not huge. Okay. So that is the calculations that we use for the generation here. And the next I'll erase this so we can dive a little bit into the capacity. Okay. Great. So now we look into the capacitor. The voltage across the capacitor is really this, right? So the current through the capacitor is described as C dV by dt. Making a similar approximation here on a very short instantaneous of time, we are looking at C delta V divided by delta t.
So the voltage ripple here across the capacitor can be expressed as IC into delta t divided by C. So you can see this is a factor of the current into the capacitor divided by capacitance. So higher the capacitance, the lower is going to be voltage ripple. So you can size the capacitance such that the voltage ripple is minimized. And typically, again, the design target here is to keep the voltage ripple to be lower. So there might be a requirement to keep your voltage ripple as low as 0.5 volts or even 1 volt depending upon how accurate you want the system to be.
And that's how they have to be sized such that you can minimize your voltage and current ripples. And this is, again, instantaneous calculations. So let me, again, get rid of these equations here. So I'll show you next how to be able to deriving these based upon the switching and then how turn on and turn off times basically impact it. So if we assume all the ripple current as a capacitor is small, then the current across the capacitor is C dV by dt. And let's consider, again, we are looking at the switching equation here.
So that was an instantaneous equation that I showed you earlier. But now let's look into the switching. So 0 to dt, the current here is basically I by C into 1 minus d times of I1 because we look that the current into the capacitor is basically 1 minus d times of I1, which is the source current. So delta Vc is going to be 1 minus d into dt divided by C. So if we want to size the capacitor, we take the C here, so C should be greater than 1 minus d times of dt divided by delta Vc peak to peak into I1.
So I1 is the source current, D is the duty cycle, T is the time period, which is defined by the switching frequency. And delta Vc is the amount of the ripple that we are looking at. So this is the capacitor sizing and next we will dive and see there is another passive component, right? That's the inductor. So if we consider the inductor, inductor basically creates the current ripple, which is filtered to the some extent by the capacitor. But there is also some ripple in the current and the load still.
So we will consider the current ripple by modeling a source impedance here. So we will have a source impedance connected in the circuit as shown below and see how to get your current ripple. The voltage, again, there is going to be a change of the voltage across the inductor as di dt is not going to be flat. And then in Vim and V, we know that the physics is not going to allow just the flat value. So let's replace the Vz with equivalent source and eliminate some of the DC quantities.
So here the current I1, which is the current going into the inductor. And we've got the inductor over here and this is the voltage. So this is a simple model, which is considering the current flow into the inductor. So we've got the, again, the switching waveform, which is the voltage, dv2 is the top, 1 minus d into v2 is the bottom, when it is off versus on. So it's going to change as such. That's the voltage with respect to time. If we consider the current with respect to time, there is going to be a peak-to-peak change in the current at every time when the switch is, the inductor is on or off based upon the switch conditions, there is going to be a di dt switch.
So there is a current, which is going to oscillate, and there is going to be a peak-to-peak ripple of delta Ipp. So the delta Ipp here is, let's consider there is no drop across the source impedance. The source impedance is 2 pi times of F into omega, so F L. And delta Ipp, that's the ripple current across the inductor, which can be expressed as 1 by L times of 1 minus. D into V2 into DT. So again from V here is LDI DT as we looked into the voltage across the inductor is going to be V LDI DT and from the previous equations that we saw the voltage across inductor is nothing but 1 minus D into V2 which is the V2 is the output voltage and 1 minus D is the D2 cycle.
So if you integrate 0 to DT and then take L over here into the denominator we can derive the ripple as delta ILPP is D into 1 minus D into T divided by L into V2. So that's the ripple current across the inductor. So again we will get rid of these things here from the slides. So we got the ripple current and then these two points are mainly used to size your inductor. So again so therefore we need an inductor which is larger than D into 1 minus D into T divided by delta IPP into V2.
So we have got some theoretical values now right. So amazing we have got L and C and know how to calculate them for our boost converter or buck converter. So the theory doesn't really end there. We have got the equations we know how to size them but there's another metric which is used for sizing. So this is the energy stored within the inductor or capacitor because there is going to be certain energy stored. There is also resistance within the inductor. There is also resistance within the coil of the inductor which is attached.
So wire resistance, coil resistance. Then within the capacitor we have got the ESR of the capacitor. So equivalent series resistance. So there is going to be all sorts of power loss that can happen. So we have to consider the amount of energy stored which determines the total power loss. Then the physical size is important which is determined by optimizing the energy storage and package constraint and material properties. So again in this lecture we will not go into designing these things but the part of this course we will look into later on in coming weeks on how to design the inductor, how to select your capacitor, how to select your capacitor for a DC link sort of application and to be able to size and what are different technologies that's available within these capacitors.
So we will look into all those things so and be able to simulate them and understand if we are designing a system that can really work. So you want to design something that can work not just based on theory and equations for an exam. So to determine the peak energy storage requirements we must consider the ripples in the waveform. So the ripple ratios here for the capacitor is basically delta V divided by 2. So delta Vcc is the total ripple voltage across the capacitor by 2 indicates the half of the ripple and divided by Vc would basically show the voltage across the capacitor.
Similarly across the inductor is delta I divided by 2 I minus L which again shows how the equivalent ripple can be generated across the capacitor or inductor both. So again we looked into the voltage ripple or current ripple and they basically vary in such a way that the ripple is on y axis and time and then you are seeing a certain switch here. So there is either a di dt or dv dt that's changing here with respect to time and x is our mean value and then the overall delta x by 2 and minus delta x by 2 are the ripples on the positive or negative side of that mean value.
So specification of allowed ripple current and within the power converter is important so you can size your inductors and capacitor accordingly. So when we are working on a problem or a design we will basically be targeted to provide a certain ripple current accuracy say 5% and 10% handling and then a voltage ripple of typically say 1 volt or something and then you would be sizing your capacitor such a way that we can achieve it. So therefore the peak voltage across the voltage across the voltage across the capacitor is basically Vc times of 1 plus Rc and these are taking in the previous equations in the slide.
So an Il is basically Il into times of 1 plus Rl where Rc and Rl are the ripple ratios. So again solving this equation over here you can get these equations to be able to derive this. And so from our previous results for a boost converter you can derive your passive component L and C as these two values so 1 minus D into dt into I1 by the ripple factor over here times of Vc and similarly for inductor. D into 1 minus D into T divided by 2 Rl I into V2.
So that does finish and wrap up our KCL, KVL and periodic study state analysis and we will take a pause here and we will continue again on CCM and DCM modes within this next session for the same week 1.