Challenge

Week 5 Challenge

1)

ANS:-

AIM:- To generate manual wind loading in the design report based IS code as per the following input.

TOOLS REQUIRED:

  1. IS code book.
  2. Calculator.
  3. Ms Excel.

PROCEDURE:-

  • First we have to open Microsoft Excel and enter the require values for calculation.
  • Now we should check required standard values from IS code book.
  • Now w should measure the dimensions of the project in terms of length,breadth and height.
  • Now assume basic wind speed as 39m/s (Given).
  • Now calculate the wind direction in both the directions i.e.X(+Cpi)&Y(-Cpi) directions.
  • Now we should calculate.
  • External pressure co-efficient.
  • Internal pressure co-efficient.
  • Net pressure Co-efficient.
  • Design wind pressure for wall.
  • Loading to be applied on the wall.

RESULT:-

Therefore by following above procedure we can obtain all the required values & then we can start the manual calculation procedure successfully.

2)

ANS:-

To create the required loadings on the model as per above calculations.

PROCEDURE:-

  • Firstly we should open the previous file in order to apply the wind loads to the project .

  • Now select load cases option from tool bar and then add required 8 wind loads.
  • The required 8 wind loads are as follows.
  • wind+y+cpi.
  • wind+y-cpi.
  • wind-y+cpi.
  • wind-y-cpi.
  • wind+x+cpi.
  • wind+x-cpi.
  • wind-x+cpi.
  • wind-x-cpi. as shown below.

  • After adding the required loads,now apply those loads to the structure.
  • Now set the directions for face C & D to global X.
  • Now set the directions for face A & B global Y.

  • NOw set the directions for roof component to global Z.
  • Then apply +cpi and -cpi values to all other sides.
  • Selecting Frame D and selecting the wind+y+cpi applying the load of 0.24 on face A,similarly selecting Frame D and selecting the wind+y-cpi applying the load of 1.44 on face A.

  • Selecting Frame A and selecting the wind+Y+cpi applying the load of -0.9 on Face B.

  • and similarly Selecting Frame A and selecting the wind+y-cpi applying the load of .3 on face B.
  • Selecting the frame 2 and frame 8 and selecting the wind+y+cpi applying the load of 1.32 on face C and Face D.

  • Selecting frame 2 and Frame 8 and selecting the wind+y-cpi applying the load of -0.12 on face C and Face D.

  • Applying Roof loads of -1.44 and O on both the roof tops on both sides.

RESULT:-

Therefore the wind loads are successfully applied on the model.

3)

ANS:-

AIM:- To create a separate model and generate wind loading using wind wizard.

PROCEDURE:-

  • Firstly on the workspace create a model of your choice.

  • That is to create the grid and assign the columns,beams as per the requirement for the building.

  • Now select the wind wizard option and you will be directed to a dialouge box on the workspace.

  • Now select next and finish because all the values of the structure are already taken by the software itself and there is no values that you have to change.
  • Click ok and the work is done.

RESULT:-

Hence by following the above procedure we will be able to crate a seperate model and generate wind loading using wind wizard.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.