Challenge

Week 3 Challenge

1.Calculate dead load in design report based on IS code and apply dead load on the model Finishes of 50mm Slab thickness as per the design Brick wall load Roofing load finish load=0.5*24=1.2kN/m2 slab load will be generated within the software brickwall+cement plaster thickness 230mm, brickwall loadingGL-1st floor-0.23*20*3.2=14.72kN/m3 same for 1st floor-roof level roof level-(paraphet wall height is 900mm and thickness 155mm)=0.155*0.9*20=2.79kN/m3 roofing load-finish floor-1.2kN/m2

2.Calculate live load in design report based on IS code and apply dead load on the model As per IS 875:part 3,live load for Rc offcie building are : office=3 KN/m^2 reception=3 KN/m^2 meeting room/conferece room-4 kN/m3 equipment room =10 KN/m^2 Toilets=2 KN/m^2 Store room = 5 KN/m^2 Staircase =3=4 KN/m^2 Lobby =3 KN/m^2 cooridor=4 KN/m^2 Roof (accessible)=1.5 KN/m^2

3.Generate manual wind loading in the design report based IS code as per the following input Basic wind speed = 50m/s Terrain category 2 As per IS-875:part3,

GIVEN: basic parameter basic wind speed-39 m/s terrain category-2 probable design period of building-50 years class of strcuture -A dimensions of the building greater horizontal dimension-19.225m lesser horizontal dimension-10.7m height of the building-6.4m width of frmae-1,grid A to B-6m ratio of wall and roof-coefficient wall-l/w=1.8 wall-h/w=0.6 roof-h/w=0.6 2/4 / topography factor,k3-1 risk co-efficient,k1-1(50 years) up to 10m height, terrain factor(k2)-1 important factor for cyclonic,k4-1.15 design wind speed,V2=Vb*k1*k2*k3*k4 39*1*1*1*1.15=44.85 m/s design wind pressure,Pz=0.6*vz^2/1000 0.6*44.85*44.85/1000=1.207 kN/m2 internal pressure cooefficient=0.5(20% opening as per c;ause 6.2.3.3) internal pressure coo-efficient=-0.5 wind loading calculationwind load acting along X-direction(face A) +cpi -cpi height at different level <=10m external pressure coefficient, Cpe -0.5 -0.5 internal pressure coo-eficient, Cpi 0.5 -0.5 net pressure coefficient, Cp -1 0 design wind pressure for wall 1.207 1.207 loading to be applied on the wall -1.207 0 wind loading along X-direction(face B) +cpi -cpi height at different level <=10m external pressure coefficient, Cpe -0.5 -0.5 internal pressure coeficient, Cpi 0.5 -0.5 net pressure coefficient,Cp -1 0 design wind pressure for wall 1.207 1.207 loading to be applied on the wall -1.207 0 wind loading along X-direction(face C) +cpi -cpi height at different level <=10m external pressure coefficient,Cpe 0.7 0.7 internal pressure coeficient, Cpi 0.5 -0.5 net pressure coefficient,Cp 0.2 1.2 design wind pressure for wall 1.207 1.207 loading to be applied on the wall 0.24 1.45 wind loading along X-direction(face D) +cpi -cpi height at different level <=10m external pressure coefficient,Cpe -0.1 -0.1 internal pressure coeficient, Cpi 0.5 -0.5 net pressure coefficient,Cp -0.6 0.4 design wind pressure for wall 1.207 1.207 loading to be applied on the wall -0.72 0.483 wind load in Y directionswind load acting along Y-direction(face A) +cpi -cpi height at different level <=10m external pressure coefficient, Cpe 0.7 0.7 internal pressure coeficient,Cpi 0.5 -0.5 net pressure coefficient,Cp 0.2 1.2 design wind pressure for wall 1.207 1.207 loading to be applied on the wall 0.24 1.45 wind load acting along Y-direction(face B) +cpi -cpi height at different level <=10m external pressure coefficient,Cpe -0.3 -0.3 internal pressure coeficient,Cpi 0.5 -0.5 net pressure coefficient,Cp -0.8 0.2 design wind pressure for wall 1.207 1.207 loading to be applied on the wall -0.96 0.24 wind load acting along Y-direction(face C) +cpi -cpi height at different level <=10m external pressure coefficient,Cpe -0.7 -0.7 internal pressure coeficient,Cpi 0.5 -0.5 net pressure coefficient,Cp -1.2 -0.2 design wind pressure for wall 1.207 1.207 loading to be applied on the wall -1.45 -0.24 wind load acting along Y-direction(face D) +cpi -cpi height at different level <=10m external pressure coefficient,Cpe -0.7 -0.7 internal pressure coeficient,Cpi 0.5 -0.5 net pressure coefficient,Cp -1.2 -0.2 design wind pressure for wall 1.207 1.207 loading to be applied on the wall -1.45 -0.24 AIM:Based on the above calculation apply the loadings on the model.

PROCEDURE: go to load toolbar,define load cases. generate load combinations. for dead load,finish load-select area load and enter 1.2kN/m2. for brickwall load,select full UDL/point UDL and enter the repective value. for live load,select area load and enter value as per IS code book. for wind loads,first add wall panels. select area load and respective direction of building face,enter the value an select on wall panel. RESULT: The calculated loads are applied on the model successfully

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.