Week 3 Challenge
Task – 3: Distillation
- Determine the total number of possible different column configuration for separating each of the individual component in the below mentioned composition. Explain at least 4 possible configuration
- Ethane- 0.3 mol%
- n-Pentane-0.2 mol%
- n-Hexane – 0.2 mol%
- n-Heptane-0.3 mol %
Column configuration: 1
In configuration: 1,
- Light key component is Ethane.
- Heavy key component is n-Pentane.
From T-100 ethane was separated as a distillate 1 (99.0% pure) and the rest of the components as Bottoms 1 are sent to the second column named as T-101 where n-pentane (99.9% pure) was separated as a distillate 1.1 and remaining components are in bottom product 1.1.
For T-100,
Minimum Reflux ratio = 0.185 and External Reflux ratio = 0.28.
The performance of the column is shown in below.
For T-101,
Minimum Reflux ratio = 1.907 and External Reflux ratio = 2.7.
The performance of the column is shown in below.
Column configuration: 2
In configuration: 2,
- Light key component is n-Pentane.
- Heavy key component is n-Hexane.
From T-102 Ethane & n-Pentane was separated as a distillate 2 and the rest of the components as Bottom products 2. Then distillate 2 is again fed to column T-104 where Ethen is taken out from top and n-Pentane is separated from bottom (only 40.9% pure). Then the bottom product 2 is fed to the column T-103 where we obtained n-Hexane (99.9% pure) as distillate and rest at bottom.
For T-102,
Minimum Reflux ratio = 0.405 and External Reflux ratio = 1.0.
The performance of the column is shown in below.
For T-104,
Minimum Reflux ratio = 0.002 and External Reflux ratio = 1.2
The performance of the column is shown in below.
For T-103,
Minimum Reflux ratio = 2.631 and External Reflux ratio = 3.2
The performance of the column is shown in below.
Column configuration: 3
In configuration: 3,
- Light key component is n-Hexane.
- Heavy key component is n-Heptane.
From T-105 n-Heptane was separated as Bottom product 3 (99.9% pure) and the rest of the components as distillate 3 which are sent to the second column named as T-106 where n-Hexane (99.7% pure) was separated as bottom product 3.1 and remaining components are in the distillate 3.1.
For T-105,
Minimum Reflux ratio = 0.339 and External Reflux ratio = 0.51
The performance of the column is shown in below.
For T-106,
Minimum Reflux ratio = 0.182 and External Reflux ratio = 0.32
The performance of the column is shown in below.
Column configuration: 4
In configuration: 4, n-Pentane was separated from the mixture. As shown in the below flowsheet, n-Pentane is taken out from bottom product 4 of the column T-107 and the rest of the light key components are separated from the distillate 4.
For T-107,
Minimum Reflux ratio = 0.329 and External Reflux ratio = 0.5
The performance of the column is shown in below.
Task -2,
- Based on the composition provided in s.no-1 and feed condition of 45°C and 2 barg pressure, determine
- number of stages,
- Optimum feed stage location
- condenser duty,
- reboiler duty,
- vapor loading at each stage,
- liquid loading at each stage
to separate out 99.5 mol% of ethane and 98.5 mol % of n-pentane using distillation column with column operating pressure of 2 barg.
Answer: The short-cut column profile for this task is shown below.
The feed containing all the four components is fed to the column T-108 where ethane is separated (99.5% pure) from the distillate section and the remaining components are in the bottom product. Later the bottom product of T-108 is fed to T-109 to separate n-Pentane. The n-Pentane in distillate-1 is further fed to column T-110 as it still contains Ethane. From T-110, it achieved 99.5% pure Ethane in distillate-2 and 99.5% n-Pentane in bottom product-2. The reflux ratios and performance of all three columns is given below.
Column T-108,
Minimum Reflux ratio = 0.199 and External Reflux ratio = 0.28
The performance of the column is shown in below.
Column T-109,
Minimum Reflux ratio = 1.899 and External Reflux ratio = 2.7
The performance of the column is shown in below.
Column T-109,
Minimum Reflux ratio = 0.5 and External Reflux ratio = 0.75
The performance of the column is shown in below.
Actual distillation,
At column T-111,
- number of stages - 10
- Optimum feed stage location - 4
- condenser duty – 5.067e+005 KJ/h
- reboiler duty – 6.386e+005 KJ/h
The vapour and liquid loading at each stage of the column is given below
At T-112,
- number of stages - 31
- Optimum feed stage location - 17
- condenser duty – 1.38e+006 KJ/h
- reboiler duty – 1.53e+006 KJ/h
The vapour and liquid loading at each stage of the column is given below,
At T-113,
- number of stages - 8
- Optimum feed stage location - 5
- condenser duty – 15231 KJ/h
- reboiler duty – 43173 KJ/h
The vapour and liquid loading at each stage of the column is given below,