1.1) The primary load cases to be considered for design are Dead Load Live Load/Imposed Load, Wind Load and  Earthquake Load.

1.2) ONE WAY SLAB : The one-way slab is a slab, which is supported by parallel walls or beams, and whose length to breadth ratio is equal to or greater than two and it bends in only one direction (spanning direction) while it is transferring the loads to the two supporting walls or beams, because of its geometry.

1.3) Assuming that the steel weighs 7,850 kg/m⊃3;, a cubic metre of steel would weigh 7,850 kg. To calculate the unit weight of steel, divide the steel's weight by the steel's volume. In this example, the unit weight of steel would be 7,850 kg/m⊃3;, i.e. the steel weight to volume ratio with the SI unit: Kg/m⊃3;

1.4) RCC Sections like beam, column, RCC wall and steel sections like T-sections , I-sections can be defined using sections properties in staad pro.

1.5) The beams that are connecting columns for transferring loads of a structure directly to the columns are known as primary beams. Usually, primary beams are shear-connected or simply supported and they are provided in a regular building structure.

2.1) 

Loading

The structure must be designed to resist the gravitational and lateral forces, both permanent and transient that will be sustained during construction and during the expected useful life of the structure (from 60 to 100 years). Probability will be used to consider the simultaneous occurrence of different combinations of gravity with either wind or earthquake forces. The limit states method uses prescribed factors.

Sequential Loading

For dead loads, the construction sequence should be considered to be the worst case. It is usual to shore the freshly placed floor upon several previously cast floors. The construction loads on the supporting floors due to the weight of wet concrete and its formwork will greatly exceed the loads of normal service conditions. These loads must be calculated considering the sequence of construction and the rate of erection. However, the designer rarely knows who the contractor will be, nor his method of construction.

Strength and Stability

The primary requirement of the ultimate limit state of design procedure is that the structure has adequate strength to resist and remain stable under the worst probable loads during its lifetime.
This includes all critical load combinations, augmented moments from second-order deflections (P-Delta) plus an adequate reserve; study all critical members whose failure may lead to a progressive collapse of part or the whole structure. Finally, the whole building must be checked against toppling as a rigid body about one edge of the base. Moments are taken about that edge with the resisting moment of the dead weight of the structure to be greater than the overturning moment by an acceptable factor of safety.

Stiffness

The lateral stiffness is a major consideration in the design of a tall building. Under the ultimate limit state, the lateral deflections must be limited to prevent 2nd-order P-Delta effects from gravity loading to be large enough to precipitate a collapse. In addition, serviceability requires these deflections not to affect elevator rails, doors, glass partitions, and prevent dynamic motions to cause discomfort to the occupants and sensitive equipment. This is one of the major differences of tall buildings with respect to low-rise buildings.

Drift Limitations

The parameter that measures the lateral stiffness is the drift index. It is defined as the ratio of the maximum deflection at the top of the building to the total height. In addition, each floor has an index called the inter-story drift index which checks for localized excessive deformation. There is no national code requirement for the drift index. Different countries use from 0.001 to 0.005. For example, for an office building this would mean a range of 6 to 20 inches in a 33 story building. Lower values are used for hotels and condominiums because the noise and discomfort at those levels are unacceptable. For conventional structures, the preferred range is 0.0015 to 0.0030 (in other words, from 1/650 to 1/350).

Human Comfort

Buildings subjected to both lateral and torsional deflections (plus vortex shedding and other usual effects) may induce in their human occupants from discomfort to acute nausea. These are major factors in the final design of the building.

Creep, Shrinkage and Temperature

In very tall buildings, the cumulative vertical movements due to creep and shrinkage may cause distress in the structure and induce forces into horizontal elements especially in the upper regions of the building. During the construction phase, elastic shortening will occur in the vertical elements of the lower levels due to the additional loads imposed by the upper floors as they are completed. Cumulative differential movements will affect the stresses in the subsequent structure, especially in the building that includes both in-situ and pre-cast components. Buildings subjected to large temperature variations between their external faces and the internal core, and that are restrained, will experience induced stresses in the members connecting both.

Fire

One of the most extreme conditions placed upon a building is fire. It is a primary concern during design. Temperature range and its duration must be estimated from its probable cause and the materials present in the building that could provide fuel for its continuation. Also of interest are possible sources of ventilation, and egress from alterative paths must be considered.
The behavior of the different structural components must be known. For example, mild steel at 700°C is only 15% of the yield strength at 20°C, and its elastic modulus drops to only 45% of its original value.

The Effect of the Foundations upon the Building

Minor movements of the foundations are greatly exaggerated by a tall building, leading to very large inclinations of the tower. This topic is complex, and will be treated later.

2.2) 

LOAD TRANSFER MECHANISM IN A STRUCATURAL SYSTEM

 

LOAD TRANSFER MECHANISM IN A STRUCATURAL SYSTEM
The process of transfer of exposed load from one structural element to the other structural element is called as load transfer mechanism. Load transfer mechanism basically depends on the elements on which load transfers, this is referred to as load path. Based on the load path the pattern of load transfer mechanism varies which in turn depend on the type of load which the structure has to transfer.
 
Generally there are two types of load paths they are
1.     Gravity load path
2.     Lateral load path
 
Gravity load path: In this type of load path the vertical gravity load; which includes the dead load of the structure and live load on the structure acts on the slab are efficiently transferred to beams, from beams it is then transferred to columns and from columns to the supports, finally from the supports to the underlying earth.
 
The load transfer mechanism of gravity load path is generally shown by the figure below
  Pattern of load transfer in gravity load path
1.     In case of transfer of the load from slab to the adjacent beams the triangular or trapezoidal pattern is followed, which in turn causes additional torsional moment on the beam at its ends.
 
2.     The loads received by the slabs on the beams at the joints will causes in bending of the beam and the results to form 3 reactions at its end position  
 
·        One in vertical direction - Acts as an axial load on the neighboring column.
·        One in horizontal direction – Acts as a shear force on the neighboring column.
·      Moment at the end of the beam - Acts as a bending moment on the neighboring column.
 
3.     The loads on the columns transfer to the supports efficiently and further to the foundation soil. The structure can be said to be stable if the upward pressure by the foundation soil is equally resisted by the load on the structure.
 
Lateral load pattern: In this type of load path the lateral loads; which are the earthquake loads and wind loads are transferred efficiently through the building. The components of the lateral load paths are
 
a.     Horizontal components such as roof, floor and foundation.
 
b.     Vertical components such as shear wall and frames.
Pattern of load transfer in Lateral load path
1.     Roofs and floors which are also called as diaphragms; transfers load to the shear walls(also termed as the primary load resisting elements).
2.     Shear walls can also resist the gravity loads efficiently and further transfers the collective load to the foundation; inturn foundation collects loads from all the stories and then transfers it into the underlying soil.
 
3.1)  In a one-way slab, the main source of load transmission is the longer direction. On the other hand, in the two-way slab, the shorter and larger sides are the main source for transmission of load. In a one-way slab, the bending moment occurs in a singular direction, while in a two-way slab it occurs in both directions.
 
3.2) Secondary Beam: A horizontal beam connecting primary beams (simply supported or shear connected.) Function: It will transfer the load to the primary beam and not directly connected to the columns.
 
3.3) The primary load cases are Dead load , Live load , wind load , earthquake load etc.
DEAD LOAD : IS 875 PART 1
LIVE LOAD :   IS 875 PART 2
WIND LOAD : IS 875 PART 3
EARTHQUAKE LOAD : IS 1893:2016
 
4) 
STAAD.Pro Physical Modeler Analytical STAAD.Pro Modeling User Interface
1. Select the members which all have the same section. 1. Add the profile you want to use from the Section Database.
2. Select the Section tool in the Assign properties group on the Member ribbon tab. 2. Select the member property in the Properties dialog.
3. Select the profile to use and click OK. 3. Use the cursor to click on members with this property.
5) Make a frame model in STAAD.Pro, comprising of two or more consecutive beams.
  1. Select two or more colinear, interconnected beams in th emodel. Refer the pre-requisites of the analytical members for details.
  2. Either:

    Select the Form Member tool in the Physical Member toolbar

    or

    Right-click and select Form Member from the pop-up context menu.

The details of the formed Physical Member can be seen in the General | Physical Member page at the right pane of the window.