Structural Modelling using Etabs 2018

This is a comprehensive structural modeling and design challenge for a G+7 residential building in Seismic Zone V, with an emphasis on integrating architectural functionality and seismic performance. Let’s break this down step-by-step, from conceptual framing to ETABS modeling and analysis verification, as per IS 1893:2016 and IS 13920:2016.


🏗️ Step 1: Conceptual Framing Plan Layout

📌 Inputs from Architectural Drawings:

  • Floor Plan (repeated for 7 floors): includes brick wall layout and usage (for live load estimates)

  • Section through Staircase & Lift Core: defines vertical circulation and potential shear wall zone

  • Ground Floor Parking Layout: defines clear zones—columns/shear walls cannot obstruct vehicle movement

🔍 Initial Design Strategy:

✅ Column Placement:

  • Start with column grid shown in floor plan

  • Adjust column positions in parking level to ensure:

    • No obstructions at entry/exit ramps

    • Avoid columns in drive aisles

  • Ensure symmetry (or near-symmetry) to reduce torsion

  • Use minimum eccentricity in column layout w.r.t. building mass center

✅ Shear Wall Placement:

  • Place shear walls in:

    • Stair core

    • Lift shaft walls

    • End walls or side walls (if architecturally acceptable)

  • Extend from foundation to mumty level

  • Use C-shaped or L-shaped walls at stair/lift core for added stiffness

✅ Beam Layout:

  • Align beams with wall lines where possible

  • Connect all columns with beams for rigid frame action

  • Consider beam-free areas over parking where flat slab or transfer beams may be used

✅ Slab Type:

  • Use waffle slab or conventional RCC slab, depending on span and architectural needs


📏 Step 2: Load Calculations

🧱 Dead Load:

  • AAC Block Walls (assumed 150 mm thick): ~3.5 to 4 kN/m

  • Floor Finish: 75 mm tiles → ~1.8 kN/m²

  • RCC slab (150 mm): 3.75 kN/m²

🚶 Live Load: as per IS 875 Part 2

  • Residential: 2.0 kN/m²

  • Corridors/staircase: 3.0 kN/m²

  • Parking: 2.5–5.0 kN/m² depending on type

🛢️ Other Loads:

  • Water Tank: 20 KL = 200 kN → Apply point load on roof slab over staircase

  • Lift Machine Room: Apply extra UDL/point loads at mumty level


🧠 Step 3: Model in ETABS

3.1 Define Geometry:

  • Create floor levels (Plinth + 7 Storeys + Mumty)

  • Define gridlines as per architectural plan

3.2 Define Materials:

  • Concrete: M30 (or M35 if preferred)

  • Steel: Fe500

  • AAC block: user-defined material for wall loading

3.3 Define Load Patterns:

  • DEAD

  • LIVE

  • WALL LOAD

  • FINISHES

  • SEISMIC_X

  • SEISMIC_Y

3.4 Assign Section Properties:

  • Beams: 300×450 mm (adjust later)

  • Columns: 600×600 mm or 750×750 mm (adjust based on axial load)

  • Shear Walls: 250–300 mm thickness (core walls, external L/C walls)

  • Slab: 150 mm thick

3.5 Load Assignments:

  • Use uniform line loads for walls

  • Assign area loads for finishes/live loads

  • Use shell area loads for water tank/lift room as additional superimposed dead loads


🧪 Step 4: Response Spectrum Analysis (RSA)

4.1 Define Seismic Parameters (IS 1893:2016 – Zone V):

  • Zone factor (Z) = 0.36

  • Importance Factor (I) = 1.0 (residential)

  • Response Reduction Factor (R) = 5 (SMRF)

  • Soil Type: Site-specific (assume Medium - Type II)

  • Damping: 5%

4.2 Load Combinations:

Use auto-generated combinations with RSA:

  • DL + LL

  • DL + EQx

  • DL – EQx

  • DL + EQy

  • DL – EQy

  • DL + LL + EQx...


🧮 Step 5: Check Code Compliance & Design Output

✔ Inter-storey Drift:

  • Check that inter-storey drift ≤ 0.004h (h = storey height)

✔ Irregularities:

  • Plan irregularity: Check eccentricity between center of mass and stiffness < 0.15

  • Vertical irregularity:

    • Check for sudden stiffness/strength reduction in vertical elements

    • Ensure consistent column/shear wall layout floor to floor

✔ Shear Wall Requirements:

  • Ensure shear wall area ≥ 0.0025 of plan area per floor

  • Shear wall height-to-length ratio within limits

✔ Column Axial Load Ratio:

  • Confirm P/fckAg < 0.4–0.5 (for compression-controlled columns)

  • Adjust column sizes where axial demand is high

✔ Moment of Inertia:

  • Use effective moment of inertia:

    • Beams: I_eff = 0.35 I_gross

    • Columns: I_eff = 0.7 I_gross

    • Shear walls: as per stiffness modifiers in IS 1893


📐 Step 6: Refine Model

  • Resize elements based on ETABS outputs (deflections, forces, utilization ratios)

  • Add or shift shear walls if torsional irregularity or drift too high

  • Avoid placing heavy walls asymmetrically

  • Rerun analysis each time and iterate until IS code compliance is met


🧾 Final Deliverables

✅ Structural Model Checks:

  • ✅ All code checks (IS 456, IS 13920, IS 1893) passed

  • ✅ Acceptable drift, stiffness irregularities

  • ✅ All elements within design limits

  • ✅ Proper shear wall placement & ductile detailing

✅ Drawings/Exports (from ETABS):

  • Plan & elevation views of beams/columns/walls

  • Reinforcement detailing (AutoCAD or ETABS export)

  • ETABS .EDB model file with saved load combinations and design results