Sketch a G+1 residential plan according to Vaastu Shastra and Calculation of Loads as per IS code
AIM : To sketch a plan of G+1 floor residential building according to Vaastu Shastra and listing down the names of the structural drawings required to be provided to the construction site.
INTRODUCTION TO VAASTU SHASTRA :-
Vaastu Shastra :-
Vastu Shastra is the Ancient Indian Science of architecture and acts as a guideline to design your home in the way that enhances positive energy.
Our nature is abundant with powerhouses of energy sources like the Sun, Wind, Moon, Water, Earth and Fire.
A good home needs to radiate the right kind of energy.
A person dwelling in a house comes under the influence of a specific energy field.
Architectural changes are not possible for a ready to move in house.
Significance of Eight directions :-
Four cardinal direction are North, South, East and West.
Four intercardinal direction are North-east, North-west, South-east and South-west.
Each direction signifies an aspect of life and is governed by various gods as per Vaastu Shatra.
North - Wealth
South - Dharma.
- West and East - Overall prosperity
Basic principles of Vastu Shastra :-
- Shape :-
Rooms should be preferably be square or rectangle.
- Room Basics :-
Rooms should be airy, well lit, bright and clean.
- Home center :-
Centre of the house should be an empty space.
- Stairs and Furniture :-
Heavy furniture should be kept in the south-west direction.
- Water :-
Avoid keeping plants and water features in the bedroom.
- Dining Table :-
Dining space should be near the kitchen and not near the main door.
- Mirror placement :-
Mirror facing the bed is strictly not allowed. Mirrors in the bedroom need to be placed in such a way that the bed cannot be seen.
Auspicious directions as per Vastu Shastra :-
- Kitchen :-
South-east is the best direction fo kitchen.
North-east to be avoided.
- Staircase :-
South-west is the best for stairs.
North-east to be avoided.
- Toilet :-
North-west is the best.
North-east to be avoided.
- Master Bedroom :-
South-west is the best.
- Guest Room :-
North-west is the best.
- Living Room :-
North-west is the best.
- Over Head Tanks :-
West is the best.
- Under ground Tanks :-
North-east is the best.
South-west to be avoided.
PROCEDURE :-
SKETCH OF GROUND FLOOR PLAN :-
Dimensions of Ground Floor plan :-
Drawing/Living Room - 4.76m * 3.8m
Dining Room - 4.5m * 3.5m
Bed Room - 4.5m * 4m
Store Room - 3.5m * 2.8m
Wash Room - 2.5m * 3.5m
Guest Room - 4.2m * 3.3m
Kitchen - 3.2m * 3.8m
Parking Area - 6.23m * 3.5m
Pooja Room - 2.8m * 3.5m
SKETCH OF FIRST FLOOR PLAN :-
Dimensions of First Floor Plan
Bed Room 1 - 4.5m * 4m
Toilet - 3.5m * 2.5m
Study Room - 3m * 3.3m
Bed Room 2 - 4m * 3.5m
Terrance - 13.69m * 4m.
Other Dimensions :-
Other Dimensions :-
Thickness of External/Internal Wall - 0.23m (230mm)
Thickness of slab - 0.25m (250mm)
Dimensions of column - 0.3m * 0.3m
Dimensions of beam - 0.3m * .45m
Height of the wall of Ground floor - 4m
Height of the wall of First floor - 3.5m.
Calculation of loads :-
1) Dead load Calculations :-
A) Dead load of Columns :-
- Dimension of column = 0.3m * 0.3m (300mm * 300mm)
- Height of column = (Slab thickness X 2) + Height of wall for ground floor + Height of wall for first floor
= (0.25 X 2) + 4 + 3.5 = 8 m .
- Total volume of one Column = 0.3 * 0.3 * 8
= 0.72 m3"
- Unit weight of RCC = 25 KN/m3" (as Conforming from IS 875 : Part-1)
- Dead load of one column = Volume of Column * Unit Weight of RCC
= 0.72 * 25
= 18 KN.
B) Dead load of Beams :-
- Dimension of Beam = 0.3m * 0.45m (300mm X 450mm)
- Total volume of Beam per meter length = 0.3 * 0.45 * 1
= 0.135 m3
- Unit weight of RCC = 25 KN/m3 (as Conforming from IS 875 : Part-1)
- Dead load of Beam per unit meter length = 25 X 0.135
= 3.375 KN.
C) Dead load of Slabs :-
- Slab is always designed for the span of 1 m2 Hence, assume size of slab as 1m * 1m
- Thickness of slab = 0.25 m (250 mm)
- Unit weight of RCC = 25 KN/m3 (as Conforming from IS 875 : Part-1)
- Total volume of Slab per Sq.meter span area = 1m * 1m * 0.25m
= 0.25m3
- Dead Load of slab per Sq.m span area = 0.25 X 25
= 6.25 KN.
D) Dead load of Walls :-
- Thickness of External/Internal wall = 0.23m (230mm)
- Unit Weight of Brick Masonry = 20 KN/m3 (as Conforming from IS 875 : Part-1)
- Height of Ground floor wall = 4 m
- Dead Load of Ground floor wall per unit meter Length = Volume of wall per meter length * Unit weight of Brick Masonry
= 4 * 0.23 * 1 *20 = 18.4 KN .
- Height of First floor wall = 3.5 m
- Dead Load of First floor wall per unit meter Length = Volume of wall per meter length * Unit weight of Brick Masonry
= 3.5 * 0.23 * 1 * 20
= 16.1 KN
- Total Weight of both Ground and First Floor Walls per unit meter Length = 18.4 + 16.1
= 34.5 KN.
2) Live load Calculations :-
As per IS -875 Part-2, for residential building, Live Loads are taken as :-
- Living/Dining - 2 KN/m2
- Kitchen - 2 KN/m2
- Bed Room - 2 KN/m2
- Wash Room - 2 KN/m2
- Toilet - 2 KN/m2
- Store Room - 2 KN/m2
- Terrace - 3 KN/m2
- Staircase - 3 KN/m2
3) Wind load Calculations :-
- If the height of the building is more then 10 meters then building need to be designed for wind load.
- But, in this case, Height of the building is 8 meters. Thus, Wind Load need not to be considered.
The names of the structural drawings required to be provided to the site for construction are :-
- Centre line drawing
- Footing and column layout with reinforcement details
- Column schedule with reinforcement details
- Plinth beam layout with reinforcement details
- Each floor beam layout with reinforcement details
- Lift pit and head room with reinforcement details
- Each Floor plans
- Foundation plan
- Block plan
- Roof slab layout
- Column layout
- Column sections
- Septic tank detail.
- Overhead water tank detail
- Furniture plan
- Road drainage plan
- Setting out plan
- Section drawings of buildings
- Plumbing details
- Electrification details
Results :-
- The plan of G+1 Floor Residential Building is prepared with consideration of Concept of Vaastu Shastra.
- The load calculations are done as per the IS code considerations.
References and IS codes used for the design :-
- IS 875 :1987 (Part 1) for Dead load
- IS 875 :1987 (Part 2) for Live load
- IS 875 :1987 (Part 3) for Wind load
- IS 456 :2000 for Reinforced Concrete