Challenge

Project 2_Design & Analysis of a Hostel building at Guwahati, Assam

Aim - To carryout modelling, analysis, design, and preparation of construction drawings of a G+3 RCC building situated in Guwahati Assam.

Introduction 

  • ETABS is an engineering software product that caters to multi strorey building analysis and design.
  • SAFE represents the state of art in three dimensional finfite element technologies for structural engineering.
  • Here, in this project we are carrying out the design analysis of a G+3 building situated in Guwahati,
  • Assam using ETABS software and then foundation design is carried out using SAFE software

Procedure 

Step 1)

  • Open the Etabs software from deskstop icon
  • Once software is open - Click on New model 

 

Step 2)

  • Once you click on New model
  • A Model Initialization setting will open
  • Select - Metric SI units
  • Select section database - Indian
  • Select Steel code - IS 800-2007
  • Select Concrete design code - IS 456-2000

 

Step 3)

  • Once you click Okay
  • A following dialog box of grid settings will open
  • In New Model Quick templates under grid dimensions select the custom grid spacing

  • Once you click on Custom grid spacing
  • Click on Display grid data as spacing

 

  • Now input the storey details
  • As given in question and Story 1 was selected as the Master story
  • Click on Okay.

 

Step 5)

  • Once you click on Okay
  • A plan and 3D view of model is created in model space

Step 6)

  • Now we have to define the materia properties
  • Click on Define
  • Click on Material properties

 

  • Add New material as Concrete
  • Select Grade of conccrete -
  • Standard as Indian
  • Click on Okay.

 

  • Click on okay
  • The remaining data is as per IS Code

 

  • Similarly we have to define the materia properties for Steel
  • Click on Define
  • Click on Material properties
  • Select New material as Rebar
  • Select Grade of Steel - HYHD -
  • Standard as Indian
  • Click on Ok

 

  • Click on Okay
  • The remaining data is as per IS code

 

  • Material properties is added

 

Step 8)

  • Now we have to Define the section properties (Column and Beam)
  • Click on Define
  • Select - Section properties
  • Click on Frame Section

 

  • Click on Okay.
  • Click on Add new property
  • Select Rectangular shape

 

  • Give property name Beam - 400x500(given)
  • Material type - M25
  • Section Shape - Concrete Rectangular
  • Depth - 500 mm
  • Width - 400 mm

  • Click on Modify / show Rebar
  • Select M3 Design Only (Beam)
  • Select the rebar materials as HYHD Fe415 in both the direction
  • Click on okay.

 

  • Similarly we have to follow the same steps for Column also.
  • Property name - Column 550 x 550 mm
  • Material - M25
  • Depth - 550 mm
  • Width - 550 mm

 

  • Click on Modify / show Rebar
  • Select M3 Design Only (Column)
  • Select the Rebar materials as HYHD Fe415 in both the direction
  • Click on okay.

 

Step 9)

  • Now we have to define Slab
  • Click on Define
  • Select Section Properties - Select Slab properties
  • Click on Slab Section
  • Give property nam e- Slab 150
  • Slab material - M30
  • Modeling Type - Membrane
  • Type - Slab
  • Thickness - 150 mm

 

Step 10)

  • Now we have keep the 3D view also to see the properties
  • Now we have to add the columns and beams
  • Click on Quick Draw Column option
  • Select the Column properties which we have defined earlier
  • Draw the columns at the grids as shown in below
  • Note that - All stories option should be selected which is at the Bottom
  • Similarly we have to draw beams also
  • Select Quick Draw Beam option
  • Select the Beam properties which we have defined earlier
  • Draw the beam as shown below

 

Step 11)

  • Now we have to add the slabs
  • Select Quick draw floor
  • Draw the slabs as shown below

 

Step 12)

  • Now we have to assign the loads
  • Select Define
  • Click on load patterns
  • Define load pattern dialogue box will open
  • Add the Following loads and Select the IS code for Seismic Case as IS -1893

 

  • The direction and eccentricity were selected as the X direction
  • The Response Reduction Factor R was taken as 5
  • Seismic zone is 5 so Z=0.36
  • Soil type was taken as III
  • Importance factor for residential building with less than 200 is taken 1 and time period is taken as 0.2

 

Step 13)

  • Now we have to assign the loads to the strucure -
  • AAC block load - 3.5 kn/m2

 

 

  • Live loads were applied to slabs next.
  • As per IS 875 in residential buildings its 2kn/m^2 for rooms 

 

 

Floor Finish

  • In the same way select slabs to assign floor finish which is 1 Kn/m^2

 

Step 14)

  • Now we have to assign Mass source
  • For that Define menu- mass sourceoptions to open the mass source dialogue box.

 

  • Now select Modify mass source data option and click OK
  • Now mass source datawas provided as shown and load patternwas also added to it.
  • For live load upto 3kn/m2-we have to assumed some fraction of live load i.e 25%

 

Step 15)

  • Now we haey to assign diaphragm
  • In assign menuselect Shellfollowed by Diaphragm to open the shell Assignment diaphragm dialogue box
  • Select D1 from the diaphragm assignments and click apply followed by OK.

 

  • The Diaphragm D1 is applied and is as shown below.

 

Step 16)

  • Now we have to add the load combinations

 

  • Click on Add default Design Combo

 

Step 17)

  • Now we have to create a Modal analysis 
  • For that define tab-modal cases and select modify
  • Enter the data's as shown in image.
  • Maximum number as 20.

 

Step 18)

  • New function was defined as per the IS 1893 for response spectrum analysis.
  • After selecting the response spectrum the new tab is visible,
  • In that we choose IS 1893:2016 from the "Choose function type" and click on the Modify /Show option as shown below

 

 

  • Two load cases was defined for response spectrum analysis and set default scale factor initially

 

 

Step 19)

  • Now we have to check the model for errors,go to Analysis tab and select check model.

 

Step 20)

  • iNow Run the model
  • Click on Run Analysis

 

Step 21)

Modal Participation ratio:-

  • Modal number check for that go to Display-Show Tables-Analysis Results-Structure Output-Modal Information-Modal mass participation ratio.
  • According to IS 1873 clause 7.1, the natural period corresponding to fundamental torsional mode of oscillation
  • should not be greater than sum of two fundamental translational mode of oscillation (Tx+Ty>Txy)-from table 0.789+0.749=1.534>0.745. hence no torsional irregularity.
  • IS 1873-clause 7.1, table 6 the firstthree modes contribution should be more than 65% of mass participation factor in each principal plan direction. Here it is 0.71>0.65.
  • Here Tx=0.789 and Ty=0.749, differ by 4%, hence conclude that building is irrregular in mode of oscillation in two principal plan direction.
  • From modal number, maximum required is 13 number as it captures more than 90% of mass in all 6 degrees of freedom.

Storey response plot:

  • For this go to Display-Story Response Plot-Maximum Storey drift
  • Here storey response for maximum storey drift is less than 0.004 for both X and Y

 

 

  • Beam Design Check
  • Click on beam design check

 

  • Check for Beam Shear reinforcement
  • Column Longitudinal Reinforcement

 

  • Column Shear Reinforcement
  • Beam Reinforcement details

 

  • Column Reinfocement Details

 

  • Design of Foundation - Pile foundation

 

Step 1)

  • In order to export the ETABS model into SAFE click on file - Export - Story as SAFE V12.f2k file option
  • Once you click on this option folowing diaog box will open

 

  • Select Story as Base
  • Now Save the file to desired location

 

Step 2)

Given data:

  • Column of size:- 550mm *550 mm ii) pile has a load carrying capacity of 280KN
  • Pile length-16 m and dia of pile -500 mm
  • SBC-150kN/m^2

Step 3)

  • Number of piles=Total Axial load/pile capacity= (1.5DL+1.5LL)/280= numbers
  • Piles in the springs are defined as spring so for that the spring constant

Step 4)

  • K=EA/L E=5000(fck)^0.5=5000(25)^0.5=250 00 N/mm^2
  • Area of pile =22/7*d^2=3.142* (500)^2/4=196375m^2
  • L-10000m K=25000*0.7855/16=306835.9N/mm
  • =419
  • Spacing of the piles as per clause number 6.6.2 of IS 2911
  • the spacing between the piles =2.5dia of the piles

                                            =2.5*500=1250mm

Step 5)

  • We can see that all the grids are exported to the safe.

Step 6)

  • Now we have to assign the Material proprties
  • Define - Material Properties
  • Click on Add new materials

 

  • Once you click Add new material add the following parameters
  • Material Type-Concrete
  • Grade- M25

 

 

  • Simialarly add the rebar properties

 

Step 7)

  • Now we have to define Slab properties
  • In pile cap we have to define 3 slabs properties
  • For Pile Foting
  • For Column
  • For Pile cap

 

 

 

Step 8)

  • Once slab proerties are defined
  • Now we have to start the modeling
  • Select Quick draw slab options

Step 9)

  • Now we have to add Springs to the pile because it behaves like a spring
  • Click on Assign - Support Data - point springs
  • Spring Constant from above calculation is taken as
  • Add Spring Constant 419 kn/mm
  • Select - Compression Only

 

Step 11)

  • Check the model
  • And Run the analysis

 

  • Check for Displacement - We found that Displacement is less than allowable settlement
  • i.e 0.8 25mm

 

Step 12)

  • Now we have to add the Design Strips
  • Click on Edit - Add/Edit Design Strips
  • Add the strips in both X and Y direction

 

 

Step 13)

  • Run the model again
  • Click on Display - Show slab Design

 

  • Similarly in B direction

 

Results:-

  • G+3 hostel was designed and analysed in ETABS
  • Foundations was designed and analysed in SAFE
  • All the check are done as per IS 13920-2016
  • Column Detail Reinforcement

  • Beam Reinforcement

  • Pile Cap Reinforcement

Your portfolio, next