QUESTION : Develop general arrangement for the RC office building. Analyze and design the building as per IS standard code in TEKLA STRUCTURAL DESIGNER. Refer the attached plan and elevation. The building to be designed for dead, live, wind and seismic loading. Report of each member to be generated and extract drawings…
Sachin Kumar
updated on 12 Dec 2022
QUESTION :
Develop general arrangement for the RC office building. Analyze and design the building as per IS standard code in TEKLA STRUCTURAL DESIGNER. Refer the attached plan and elevation. The building to be designed for dead, live, wind and seismic loading.
Report of each member to be generated and extract drawings for structural plans, beam reinforcement details from the software.
ANSWER :
AIM : To develop a model as per the given plan and analyze and design the structure.
TOOLS USED : Paint.
. Manage property sets.
. Construction levels.
. Grids.
. Columns.
. Beams.
. REports.
. Model report.
. Show report.
.Interactive design.
. Slabs on beams.
. Frames.
. Roof panels.
. Wall panels.
. Loads.
. Loadcases.
. Seismic wizard.
PROCEDURE :1. Take the screenshots of the plan and open them in paint.
2. Draw the positions of columns and beams in paint.
3. Open tekla file and create the construction levels for the structure according to the plan.
. Construct horizontal and vertical grid lines.
5. Select the size of the concrete column section used in the construction as per the requirement.
6. Go to manage property sets and create members used for the modeling.
7. Go to model tab and insert concrete columns in the structure.
8. Go to model tab and select the beams tool and draw the beams as per the plan.
9. We can check the structure in 3D for neat view.
10. Repeat the same process for the the levels as per the plan.
12. Go to 3D view to get a clear view of the slabs inserted.
13. Insert frams which will be helpful while applying loads on the structure.
14. Add wall panels to the structure.
15. Repeat the same step for all the walls.
16. Go to loads and create new load cases.
17. Add the dead load on the beams.
18. Add the dead loads on the slabs.
19. Repeat the same step for all the floors.
20. Add live load on the structure for all the floors.
21. Do the wind load calculation for all the sides for both X and Y ( including both +Cpi and -Cpi values).
22. Start applying the wind loads on the structure.
23. the same process for all the sides.
28. Add loads which will be applied are visible now.
34. Check eachand every coumn and perform interactive design.
35. Now we can model the structure by pressing on model report to obtain the reports.
RESULT : With the above steps we can design and model the structuer as per the given plan. We can add loads ( dead, live, wind and seismic) on the structure and analyze the structure.
Leave a comment
Thanks for choosing to leave a comment. Please keep in mind that all the comments are moderated as per our comment policy, and your email will not be published for privacy reasons. Please leave a personal & meaningful conversation.
Other comments...
Project 2
1. Design a Warehouse Building located in Chennai using STAAD Pro Connect Edition. The specification must be as follows: Width 30m Length50m Eave Height 9m Bay spacing 6m Soil type Medium Safe Bearing Capacity 200 kN/m2 Roof slope 1 in 12 Assume suitable sections for structural elements. Follow IS800:2007, IS1893 and IS…
24 Jan 2023 01:20 PM IST
Project 1
1. Design a multi-storey Residential Building located in Bangalore using STAAD Pro Connect Edition. The specification must be as follows: Building floors G + 6 + R Plan dimension B = 25m , L = 16m Storey Height h = 3.5m Soil Hard soil Use Residential Purpose Safe Bearing Capacity 180…
16 Jan 2023 03:12 PM IST
Week 3 Challenge
1. 1. State the primary load cases to be considered for design. ANSWER: . Dead Load (IS-875: PART1) . Live Load (IS-875: PART2) . Wind Load (IS-875: PART3) . Snow Load (IS-875: PART4) . Seismic Load (IS 1893: 2016) 2. What is a One – Way slab? ANSWER: One way slab is the slab in which the ratio of its longer…
09 Jan 2023 02:29 PM IST
Week 2 Challenge
1. How will you assign Circular section to column? AIM:To assign Circular section to column INTRODUCTION: Columns are defined as vertical load-bearing members supporting axial compressive loads chiefly. This structural member is used to transmit the load of the structure to the foundation. In reinforced concrete buildings…
09 Jan 2023 09:15 AM IST
Related Courses
Skill-Lync offers industry relevant advanced engineering courses for engineering students by partnering with industry experts.
© 2025 Skill-Lync Inc. All Rights Reserved.