Project 1_Comparative study of different storey buildings for Seismic forces

as per project1 4 bays along the length direction and 3 bays along width direction, make a 2 story building by selecting the edit story and grid option.

  • define the material m30 and steel fe415.
  • define the columns 400*400mm and beams 300*400mm, slab 150mmas per given.
  • assign these define properties to the model A.

.

  • define the loads, dead load,live load, wall load and sesmic forces in x and y direction.
  • assign these loads to the model by selecting beams to wall loads and selecting slab to live load.
  • assigning diaphragm to the slabs

run analysis of model A.

  • Create a model B by save as the model A.
  • Add three more floors to the model A ,same properties of model A .

  • assigning diaphragm to the slabs.
  • run analysis of model B.

model C as same as model B but need to change the column size.

  • modify the existing column 550*300 mm. change the direction by asign local axis changing the angle to change the direction of column.

model D as same as model C but need to change the direction by selecting the local axis as zero.

  • for model E need to change the column sizes and 5 more floors.
  • define the column size as 400*400mm from 6th to 10th floor.
  • hidden the beams and floor by selecting the set display option.
  • go to view and set building view as 6 th to 10th floor, select all the columns assign the property.

run analysis

  • for model F need to change the column size as 600*600mm from base to top,same as model E.
  • for model G there is a three types of columns 800*800mm from base to 10th floor,and 600*600mm from 10th to 20th floor,remaning 5 floors are 400*500mm.
  • go to edit story option add 15 floors to previous 10 floors.
  • assign the 800*800 to all columns from top to bottom.
  • goto set building view limits 10th to 10th floor and hide the beams and floors.
  • select the columns and assign the 600*600mm property.

  • assign the top 5 floors as 400*400mm same as above.
  • assign diaphargm and run analysis.

for model H assign the same column size from base to top floor 800*800mm.

run the analysis and the model J and k increase the mass load as 10% and 20%,and run the analysis and it shows the difference in natural period and dynamic characteristic of building.

Results are shown below,

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.