Identification of Cracks
1)a)
OBSERVATION:
- crack developed along the width of the beam and concrete get crushed in compression jone.
- reinforcement get exposed to atmospher, reinforcement rusted in spalled concrete place.
- crack expand in column and slab.
- beam located at the corner.
- column has only beam to trasfer the load.
- cracks are develope from bottom to top of the beam, rebar yield occur at the bottom.
CONCLUSION:
- it is flexural failure due to stress reversal during earthquake.
- top of the beam express compression and bottom tension.
SOLUTION:
- it can not be repairable.
1)b)
OBSERVATION:
- crack developed along the edge of the beam and column and it is spalled concrete.
- looks like beam saperate from column.
- concrete is not severely crushed.
CONCLUSION:
- this failure developes insufficient development length.
- during the earthquake the hiruzontal displacements will occur then it under goes the worest condition.
SOLUTION:
- providing of anchorage length between the existing column and beam is difficult so it can not be repairable.
1)c)
OBSERVATION:
- crack developed at the beam and column joint.
- beam cracked along the width.
- slab is also cracked.
- concrete is not severely crushed.
CONCLUSION:
- it is a plastic hinge failure.
- stress reversal and cyclic loads leads to damage structure at joints.
- slab is also takes more tension if it undergoes more cracks it will get damaged.
SOLUTION:
- it can be a repairable.
2)a)
OBSERVATION:
- concrete damaged all around the column.
- damage occur at bottom of beam and top of column.
- there is no wall under the beam since it look like ground floor which is used for parking.
- reinforcement is exposed at some place.
- beams donot have any damage.
- concrete is not severely crushed.
CONCLUSION:
- it is a plastic hinge failure.
- it is a soft storey failure as we consider that it is a parking area plastic hinge forms at top of ground floor building.
SOLUTION:
- it can be a repairable.
2)b)
OBSERVATION:
- concrete is severely crushed.
- column breakage diagonally.
- rainforcement get exposed to atmospher.
- spacing of stirrups is more.
- cracks occur at bottom to top of column.
CONCLUSION:
- it is a shear failure.
- there is a indufficient spacing between the stirrups
SOLUTION:
- it can be a repairable.
2)c)
OBSERVATION:
- concrete is severely crushed.
- column failed completely.
- failure at the top of column.
- there is two slabs connected to column.
- slab to slab there is less distance it leads to short column failure.
- woden piles are placed for support after the column failure, avoid the entair failure of structure
CONCLUSION:
- it is a brittle failure.
- mazzanine floor slab or beam connected at mid height of column leads to this effect
SOLUTION:
- it can be a repairable.