Project 1_Analyze and design a steel building to 10T CRANE as per IS standard code using TEKLA STRUCTURAL DESIGNER.
Analyze and design a steel building to 10T CRANE as per IS standard code in TEKLA STRUCTURAL DESIGNER. Refer the attached plan and elevation. Provide bracings and moment connection for lateral stability.
Consider dead, live, equipment and wind loading. Consider the brick wall loading for 150mm thick and 1.5 KN per sq m for wall and roof cladding.
Assume wind loading basic speed as 39m/s
Report of each member to be generated and extract drawings of structural plans from the software.
OPEN TEKLA SOFTWARE
MAKE
CONSTRUCTION LEVEL


GROUND FL0OR BEAM ND SLAB



SLAB ON FIRST FLOOR LEVEL

WITH BRACING



LOADING

WIND LOAD
WIND WIZARD



AGAIN



WIND LOAD CALCULATION
BASiC WIND SPEED = 39 M/S aas per is 875 part 3
K1= 1.0
K2=1.0
K3= 1.0
K4= 1.15
VZ = VB *K1*K2*K3*K4
44.85 M/S
DESIGN WIND PRESSURE = Pd = 0.6*Vz *Vz
= 0.6*44.85*44.85 = 1.206 kn /m2
h/W =0.31
l/w= 2.36
CPI VALUE


(0+INTERNAL)
WND LOAD FOR WALL IN ANGLE FOR FACE A
+cpi -cpi
EXTERNAL PRESSURE COFFFICIENT +0.7 +0.7
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT 0.2 1.2
DESIGN WIND PRESSURE 0.2*1.206 1.2*1.206
WND LOAD FOR WALL IN ANGLE FOR FACE B
+cpi -cpi
EXTERNAL PRESSURE COFFFICIENT -0.25 -0.25
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT -0.75 +0.25
DESIGN WIND PRESSURE -0..75*1.206 +0.25*1.206
WIND LOAD FOR WALL IN ANGLE FOR FACE C AND D
+cpi -cpi
EXTERNAL PRESSURE COFFFICIENT -0.6 -0.6
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT -1.1 -0.1
DESIGN WIND PRESSURE -1.1*1.206 -0.1*1.206
(90 + INTERNAL )
WND LOAD FOR WALL IN ANGLE FOR FACE A
+cpi -cpi
EXTERNAL PRESSURE COFFFICIENT -0.5 -0.5
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT -1 0
DESIGN WIND PRESSURE -1*1.206 0*1.206
WND LOAD FOR WALL IN ANGLE FOR FACE B
+cpi -cpi
EXTERNAL PRESSURE COFFFICIENT -0.5 -0.5
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT -1 0
DESIGN WIND PRESSURE -1*1.206 0*1.206
WND LOAD FOR WALL IN ANGLE FOR FACE C
+cpi -cpi
EXTERNAL PRESSURE COFFFICIENT +0.7 +0.7
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT 0.2 1.2
DESIGN WIND PRESSURE 0.2*1.206 1.2*1.206
WIND LOAD FOR WALL IN ANGLE FOR FACE A
+cpi -cpi
EXTERNAL PRESSURE COFFFICIENT -0.1 -0.1
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT -0.6 +0.4
DESIGN WIND PRESSURE -0.6*1.206 +0.4*1.206
FOR SLOPE AREA
ANGLE = 18
(O +INTERNAL)
WIND LOAD FOR SLOPE FOR FACE EF
+cpi -cpi
EXTERNAL PRESSURE COFFFICIENT -0.56 -0.56
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT -1 -0.1
DESIGN WIND PRESSURE -1*1.206 -0.1*1.206
WIND LOAD FOR SLOPE FOR FACE GH +cpi -cpi
EXTERNAL PRESSURE COFFFICIENT -0.4 -0.4
INTERNAL PRESSURE COFFCIENT +0.5 -0.5
NET PRESSURE COEFICIENT -1 -0.1
DESIGN WIND PRESSURE -1*1.206 -0.1*1.206