Introduction to National Building Code and Steps in a Construction project
1 A set of standards that are uniform to all structures
It protects the construction safety
Modern construction methods
Provides building standards
2 Residential buildings
Educational buildings
Assembly buildings
Institutional buidings
Mercantile buildings
Business buildings
Storage buildings
Industrial buildings
Hazardous buildings
3 Initiation
Planning
Execution
Closure
4 Construction
Finance and estimating
Contracts and bid
Geotechnical
Managements
Structural
Surveying
5 Four unit appartments
School with capacity of 1000 students
A single unit shop
Multi storey shopping complex
Steel machine factory
Four unit appartments - Group A Residential building
School with capacity of 1000 students - Group B Educational building
A single unit shop - Group E Mercandile building
Multi storey shopping complex - Group E Mercandile
Steel machine factory - Group H Industrial building
6 Design Team
Helps to finalise the plan
Evaluationaries in the project
Implementation the designs
Management Team
Accomplishment of the project
Execute the design
Achieves the satisfactory comletion of the project
7 Height limitations -
Area limitations -
Room sizing
Wall height
Thickness based on fire life and safety
Passageway requirements
HEIGHT LIMITATIONS
As per NBC 2005, clause C-2.5 the height of the building shall not exceed 15m (page no. 43)
For buidings up to the height of 15m, there is no need to provide lifts
Housinng for the low-income group shall preferbly be upto a maximum of 2 storeys
Building for housing beyond 15m in height should be resorted to in exceptional circumstances and it should be governed by provisions laid down the circle
AREA LIMITATION
According to NBC 2005, the minimum plot size with the ground coverage not exceeding 75%, shall not be less than 40 sq.m in small and medium town and not less than 30 sq.m in metropolitan area
The minimum plot size with ground coverage and exceeding 75% shall not be less than 40m2 in the small and medium town and not less than 30m2 in the metropolitan city plot sizes below 30 m2 but not less than 15 m2 may be permitted in case of cluster planning , however in such case the ground coverage and FSI shall be 100% and 2% resp..
Room sizing

Wall Height
According to NBC 2005; Clause F-3.4, the minimum height of rooms and spaces should be
Habitable room-2.75m
Kitchen-2.6m
Bath/water closet \-2.2m
Corridors-2.1m
Thickness based on fire and life safety
The thickness for masonry walls is given by table 2 of fire and life safety section of NBC 2005

Passageway requirements
As per NBC 2005, tab 1