Identification of Cracks
Ans 1a:
- Its is a form of Flexural Failure due to reversal of stress during earthquake.
- During Stress reversal, support top experiences Compression and Bottom experiences tension.
- Top compression is managed by Slab advantage. Bottom tension was not satisfied by the provided reinforcement.
- Since the reinforcement got yielded, it cannot be repaired.
Ans 1b:
- Its Beam pull out failure due to insufficient developement length of reinforcement in Joints.
- During Earthquake, the horizontal movement of structure makes this condition worse and detached the beam member from column.
- Providing anchorage length between two exixting concrete is very difficult. So not repairable.
Ans 1c:
- It's a Plastic hinge failure.
- The damage occured only in the joint zone firstof all.
- Cyclic lateral loading & stress reversal at the joints led to the damage.
- Even the slab participated to its best to handle the tension ( Slab is severely cracked means it has undergone tension with its flange condiction). But unable to control the damage.
- The joints can be strengthened.
Ans 2a:
- It's a Soft storey failure, Technically Plastic hinge formation.
- Due to absence of infill walls at ground floor, the plastic hinge forms at the top of ground storey columns during Lateral movement.
- Based on the development of crush of concrete it can either be repairable or non-reoairable.
Ans 2b:
- Its a pure shear failure.
- Inadequate shear reinforcement compels concrete takes all the shear stress.
Ans 2c:
- It's a short column failure
- An additional slab or a beam connceted to a column in mid-height leads to this effect.
- This leds to failure especially if the connection is unintentional and not accounted in design.
- The failure given is not at all repairable.