Identification of Cracks
1.(a)
- It's form of flexural failure due to reversal of stress during earthquake
- During stress reversal, support top experiences compression and bottom experiences tension
- Top compression is managed by slab advantage. Bottom tension was not satisfied by the provided reinforcement
- Since the reinforcement got yielded, it can not be repaired
1.(b)
- Its beam pull out failure due to insufficient development length of reinforcement in joints
- During earthquake, the horizontal movement of structure makes this condition worse and detached the beam member from column
- Providing Anchorage length between the two existing concrete is very difficult. So not repairable
1.(c)
- It's a plastic hinge failure
- The damage occurred only in the joint zone first of all
- Cyclic lateral loading and stress reversal at the joints led to the damage
- Even the slab participated to It's best to handle the tension slab is severely cracked means it has undergone tension with its flange condition but unable to control the damage
- The joint can be strengthened
2.(a)
- It's a soft storey failure, technically plastic hinge formation.
- Due to absence of infill walls at the ground floor, the plastic hinge forms at the top of ground storey columns during lateral movement
- Based on the development of crush of concrete, it can either be repairable or non repairable
2.(b)
- it's a pure shear failure
- Inadequate shear reinforcement compels concrete takes all the shear stresses
2.(c)
- It's a short column failure
- An additional slab or a beam connected to a column in mid height leads to this effect
- This leads to failure especially if the connection is unintentional and not accounted in design
- The failure given in the picture is not at all repairable