Challenge

Identification of Cracks

1. (A) OBSERVATION

  • concrete crused and the the reinforcement is exposed.
  • concrete spalled beyond the reinforcement which may be a sign of rupture.
  • beam top portion looks safe beacause of the flange advantage fronm slab.
  • the crack develops from bottom to top means rebar yeilding occurs in suppports bottom only.

ANSWER -

  • it form of flexural failure due to reversal of stress during earthquake.
  • during strees reversal support top experince compression and bottom experinces tension.
  • top compression is managed by slab advantages bottom tension was not satisfied by the provided reinforcement.
  • since the reinforceemnt got yeilded , it can not repaired.

1 (B) OBSEVATION-

  • CRACK ALONG BEAM - COLOUUMN EDGE.
  • CRACKS SEEM TO HAVE DEVELOPED THROUGH THE STUCTURE AS IT LOOKS MUCH WIDER.
  • BEAM LOOKS SEPERATED FROM COLOUMN AT JOINTS.
  • CONCRETE IS NOT SEVERLY CRUSED.

ANSWER-

  • its beam pull out failure due to insufficient development of reinforcement developement length of reinforcement in joints.
  • during earthquakethe horizontal movement of stucture makes this condition worse and detached the beam menmber fronm column.
  • provinding anchorage length between two existing concrte is very difficults so not reiplarable.

1 (C) OBSERVATION-

  • CREACKS ARE EXCTLY AT THE JOINT OF COLOUMN BEAM.
  • CRACKS IN BEAM DEVELPOED THROUGH ITS ENTIRE WIDTH.
  • SLAB ALSO DEVELPOED MORE CRACKS ALONG BEAM WIDTH DIRECTION.

ANSWER-

  • it is plastic hinge failure.
  • the damage occured only in the joint zone first of all.
  • cylinc lateral loading and stress reversal at the joint led to the damage.

2.(A) OBSERVATION-

  • concrete damaged at top of the column.
  • concrete damaged all around the column face.
  • beams are safe.
  • the location of column looks at edge of the building.
  • no wall are built along the coloumn means probebly at ground floor. for parking car movement acess.

ANSWER-

  • it is a soft story failure.technically plastic hinge formation.
  • due to absesse of infill wall at the ground floor, the plastic hingeforms at the top of ground story during lateral movement.
  • based on the development of crush of concrete it can eighter be repairble or non- repairble.

2. (B) OBSERVATION-

  • CONcrete developed completly breakage diagonally.
  • longitudanal reinforcement are intact.
  • shear rainforcementspacing looks wider.

ANSWER-

it is pure shear failure.

inadequate shear reinforcement compels concrete takes all the shear stress.

2. (C) OBSERVATION-

  • COLUMN FAILED COMPLETLY.
  • failure at the top of column.
  • there are two slbs connected to the column.
  • the wooden piels might be postfailure supports after column failed.

ANSWER-

  • it is short column failure.
  • an additional slab or a beam connecterd to a coloumn in mid height leads to this feilds.
  • this lead to failureespecially if the connection is unitenisonal and not accounted in design.
Your portfolio, next