Identification of Cracks

1)What is the mode of failure or damage of the beams in the figure above? Are the damages repairable? Elaborate

a)

  • By observation its seen like the concrete is crushed and reinforcement is exposed
  • Concrete is broken beyond the reinforcement it is sign of rupture
  • In the image its seen the beam top portion is safe because of the flange of the slab
  • The crack occurs from bottom to top
  • It is form of Flexural Failure due to reversal of stress during earthquake
  • During stress reversal, support top experiences tension
  • Top compression is managed by slab advantage. Bottom tension was not satisfied by the provided reinforcement
  • Since the reinforcement got yielded it can not be repaired

b)

  • The cracks is along Beam-Column edge
  • Cracks seem to have developed through the structural as it looks much wider
  • Beam look sepa1rated from the column at joint
  • Concrete is not severely crushed
  • Its beam pull out failure due to insufficient development length of reinforcement in joint
  • During earthquake the horizontal movement of structure makes this condition worse and detached the beam member from column
  • Providing anchorage length between two existing concrete is very difficult. So not repairable

c)

  • Crakes are exactly at the joint of column-beam
  • Cracks in beam developed through its entire width
  • Slab also developed more cracks along the beam width direction
  • It’s a plastic hinge failure
  • The damage occurred only in the joint zone first of all
  • Cycle lateral loading & stress reversal at the joint led to the damage
  • Even the slab participated to its best to handle the tension but unable to control the damage
  • The joint can be strengthened

2)

a)

  • Concrete damage at top of a column
  • Concrete damaged all around the column face
  • Beam are safe
  • The location of column looks at edge of the building
  • No wall are built along the column means it is probable at ground floor for parking car movement access
  • It is soft story failure technically plastic hinge formation
  • Due to absence of infill wall at the ground floor the plastic hinge forms at the top of ground story column during lateral movement
  • Based on the development of crush of concrete it can either be repairable or non-repairable

b)

  • Concrete developed completely breakage diagonally
  • Longitudinal reinforcement are intact
  • Shear reinforcement spacing looks wider
  • It is pure shear failure
  • Inadequate shear reinforcement compels concrete takes all the shear stresses
  • It is not repairable

c)

  • It is short column failure
  • Failure at top of the column
  • Column failed completely
  • An additional slab or beam connected to a column in mid-height leads to this effect
  • This leads to failure especially if the connection is unintentional and not accounted in design
  • The failure give in the picture in not at all repairable