Identification of Cracks
- IDENTIFIAION OF CRACKS
- What is the mode of failure or damage of the beams in the figure above? Are the damages repairable? Elaborate ?
- QUESTION : 1 (A)

- ANSWER :
- Mode of failure is given below :
- It is the form of flexural failure and it is developed at the bottom of the beam shown in above picture .
- this failure is occuer due to reversal of stress during earthquake .
- we see that above picture the only beam failure at bottom and column is not disturbed .
- During the stress reversal support top experiences copmpession and bottom experriences tension .
- The top compression is managed by slab advantages as shown above picture and bottom compression is not satisfied by provided reinforcement
- the reinforcement is yielded
- This is non repairable
- QUESTION : 1 (B)

- ANSWER :
- In above picture we see that the crackes are developed at beam column edges
- we see that the beam is not connected to the column .
- It is the beam pull out failure and such failure is occur due to insufficient developement length of reinforcement in joints.
- the beam is not attached to the column .
- during the earthquake the horizontal movement of structure makes this condition worse and detached the beam member from column .
- if we think about repair so that we have to provide the anchorage length between two existion concrete member and it is very difficults , so that it is not repairable .
- QUESTION : 1 (C)

- ANSWER :
- In above picture we see that the crackes are developed at the joints of column beam
- the crakes in beam are developed through its entire width .
- also slab is developed the more crackes
- This is the plastic hinged type of failure
- the major damage is occer only in joints zone
- the joints can be repairable
- QUESTION : 2
- What is the mode of failure or damage of the beams in the figure above? Are the damages repairable? Elaborate ?
- QUESTION : 2 (A)

- ANSWER :
- In above picture we see that concrete damage around the column faces
- the above beam is safe .
- in the picture the this is the column is at ground floor or basement of the building no walls are provided around the wall
- this failure is occer due to soft story failure or due to plastic hinged formation .
- during lateral movement the absence of infill walls the plastic hinged is formed at the top of the column .
- it can be either repariable or non repairable .
- QUESTION : 2 (B)

- ANSWER :
- In above picture the concrete developed complete brakages diagonally
- the spacing of shear reinforcement is too wider and less amount of shear rebar is provided .
- it is the pure shear failure
- inadiquate shear reinforcement compels concrete takes all the shere stresses
- it is non repariable
- QUESTION : 2 (C)

- ANSWER :
- In above picture we see that column is completely failled
- there are two slabes are connected to the one column .
- It is short column failure
- the failure is occur due to slab are provided at mid height it is not accoding to codel provision .
- this type of failure is not repairable .