AIM: To perform parametric study on Gate Valve by setting the opening from 10% to 80%

In this challenge parametric study is performed on a Gate Valve model by setting the opening from 10mm to 80mm. Simulation is done in ANSYS Fluent and Variation of parameters like mass flow rate, Flow coefficient and flow factor is studied.

Flow Coefficient: The flow coefficient of a device is relative measure of its efficiency at allowing fluid flow.It describes the relationship between the pressure drop across an orifice valve or other assembly and the corresponding flow rate.

Mathematically the flow coefficient Cv (or flow-capacity rating of valve) can be expressed as :

`Cv = Qsqrt((SG)/(DeltaP)`

where Q is volumetric flow rate in gallons per minute

SG is specific gravity of the fluid

and `DeltaP` is pressure drop across the valve in psi

Flow factor is metric equivalent of Flow coefficient where

Q is in cubic metre/hour

and `DeltaP` is pressure drop across the valve in bars

Flow coefficient = 1.156* Flow Factor

Case 1: Gate Opening = 10mm

  • Geometry

  • Residuals
  • Mass Flow rate
  • Results
Mass Flow Rate (kg/s) Flow Factor Flow Coefficient
0.139 49.3 56.99

Case 2: Gate Opening = 20mm

  • Geometry

  • Residuals
  • Mass Flow rate
  • Results
Mass Flow Rate (kg/s) Flow Factor Flow Coefficient
0.217 77.9 90.06

Case 3: Gate Opening = 30mm

  • Geometry

  • Residuals
  • Mass Flow rate
  • Results
Mass Flow Rate (kg/s) Flow Factor Flow Coefficient
0.328 118.29 136.74

Case 4: Gate Opening = 40mm

  • Geometry

  • Residuals
  • Mass Flow rate
  • Results
Mass Flow Rate (kg/s) Flow Factor Flow Coefficient
0.43 158.75 183.52

Case 5: Gate Opening = 50mm

  • Geometry

  • Residuals
  • Mass Flow rate
  • Results
Mass Flow Rate (kg/s) Flow Factor Flow Coefficient
0.534 217.68 251.64

Case 6: Gate Opening = 0mm

  • Geometry

  • Residuals
  • Mass Flow rate
  • Results
Mass Flow Rate (kg/s) Flow Factor Flow Coefficient
0.619 284.38 328.75

Case 7: Gate Opening = 70mm

  • Geometry

  • Residuals
  • Mass Flow rate
  • Results
Mass Flow Rate (kg/s) Flow Factor Flow Coefficient
0.693 386.05 446.28

Case 8: Gate Opening = 80mm

  • Geometry

  • Residuals
  • Mass Flow rate
  • Results
Mass Flow Rate (kg/s) Flow Factor Flow Coefficient
0.744 524.63 606.47

Comparison

From the graph we can see that as the gate opening increases the values of both Flow factor and Flow coefficient increases. This means that with increase in gate opening the efficiency of fluid flow also increases

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.