Gate Valve Parametric Study
AIM: To perform parametric study on Gate Valve by setting the opening from 10% to 80%
In this challenge parametric study is performed on a Gate Valve model by setting the opening from 10mm to 80mm. Simulation is done in ANSYS Fluent and Variation of parameters like mass flow rate, Flow coefficient and flow factor is studied.
Flow Coefficient: The flow coefficient of a device is relative measure of its efficiency at allowing fluid flow.It describes the relationship between the pressure drop across an orifice valve or other assembly and the corresponding flow rate.
Mathematically the flow coefficient Cv (or flow-capacity rating of valve) can be expressed as :
`Cv = Qsqrt((SG)/(DeltaP)`
where Q is volumetric flow rate in gallons per minute
SG is specific gravity of the fluid
and `DeltaP` is pressure drop across the valve in psi
Flow factor is metric equivalent of Flow coefficient where
Q is in cubic metre/hour
and `DeltaP` is pressure drop across the valve in bars
Flow coefficient = 1.156* Flow Factor
Case 1: Gate Opening = 10mm
- Geometry
- Residuals
- Mass Flow rate
- Results
| Mass Flow Rate (kg/s) | Flow Factor | Flow Coefficient |
| 0.139 | 49.3 | 56.99 |
Case 2: Gate Opening = 20mm
- Geometry
- Residuals
- Mass Flow rate
- Results
| Mass Flow Rate (kg/s) | Flow Factor | Flow Coefficient |
| 0.217 | 77.9 | 90.06 |
Case 3: Gate Opening = 30mm
- Geometry
- Residuals
- Mass Flow rate
- Results
| Mass Flow Rate (kg/s) | Flow Factor | Flow Coefficient |
| 0.328 | 118.29 | 136.74 |
Case 4: Gate Opening = 40mm
- Geometry
- Residuals
- Mass Flow rate
- Results
| Mass Flow Rate (kg/s) | Flow Factor | Flow Coefficient |
| 0.43 | 158.75 | 183.52 |
Case 5: Gate Opening = 50mm
- Geometry
- Residuals
- Mass Flow rate
- Results
| Mass Flow Rate (kg/s) | Flow Factor | Flow Coefficient |
| 0.534 | 217.68 | 251.64 |
Case 6: Gate Opening = 0mm
- Geometry
- Residuals
- Mass Flow rate
- Results
| Mass Flow Rate (kg/s) | Flow Factor | Flow Coefficient |
| 0.619 | 284.38 | 328.75 |
Case 7: Gate Opening = 70mm
- Geometry
- Residuals
- Mass Flow rate
- Results
| Mass Flow Rate (kg/s) | Flow Factor | Flow Coefficient |
| 0.693 | 386.05 | 446.28 |
Case 8: Gate Opening = 80mm
- Geometry
- Residuals
- Mass Flow rate
- Results
| Mass Flow Rate (kg/s) | Flow Factor | Flow Coefficient |
| 0.744 | 524.63 | 606.47 |
Comparison
From the graph we can see that as the gate opening increases the values of both Flow factor and Flow coefficient increases. This means that with increase in gate opening the efficiency of fluid flow also increases