Challenge

Concept on positioning of Columns

Q1-

1.Symmetry-
it is observed that distribution of a mass stiffness is across the plan has good symmetrical aspect.

this tends to reduce the horizontal displacement to both of the two orthogonal horizontal direction

it also has a good uniformity also

2.redundancy-

there are missing structural element in the Periphery of the plant this causes the uneven distribution of earthquake action effect in nonlinear range across the plan

the energy dissipation across the structure is very low whitch result is non reliable structure

3.bidirectional stiffness-

the building plan may not be able to register the horizontal seismic action in the shorter direction and also the resistance and stiffness in the shorter direction y-axis is less than compare the two longer direction x axis

4.ductility-

the building may not be able to resist the elastic earthquake forces in shorter direction y axis So it may result in inelastic response

the reduction in design force In the shorter direction why axis is to be compensated by ductility

Q2-

The possible type of irregularities for the given structure are soft storey irregularity
1. STiff and strong upper floor due to machinery field
2. The column in a one storey is longer than the above


Some provision to avoid the irregularities are-

The building is torsionally irregular so the building framing must be revised

the mass irregularity is avoided by providing lightweight concrete low weight machinery or by providing structure with more wood material

the structure should be built in a well symmetric manner

the column which are provided on the structure should be of same size and height through out the building the weight of the building

from ground floor should decrease towards top

Q3-

Structure is a not symmetry

largest length is provided hence Low ductility

in this building there is no proper placement of masonry infill walls

in this building redundancy in the vertical direction is not provided properly

in the framed structure capable of transfering of load from one diretion to another of the foundation's structure

the coloumns in this layout is closely spaced,resulting in formation of short paths For the transfer of stresses which is an important factor of earthquake resistant
The interaction of the staircase with other parts of 3D structure, specifically the interaction with beam, Coloumn and shear wall, result in pattern of deformation that are not typically studied during design process
The increased strength and stiffness of structure of in the stairway region for e.g. will influence the seismic torsional distress of the structure during and may lead to Shear failure to of the staircase or other structural element

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.