Section Modulus Calculation for Hood design
SECTION MODULUS OF HOOD
section modulus is termed as the ratio of second moment of area and distance from N.A (Neutral axis) to the extreme fiber. Also it is the measure of strength of given member.
Neutral Axis plane- ZY plane
S = Section Modulus
I = Moment of Inertia
Y = distance between the nuteral axis and the extreme end of the object
for Initial Hood design
y = 431.5mm
Max MOI- 4.637177310e+006 mm4 = 4637177.31
Min MOI- 1.343127270e+004 mm4= 13431.2727
section modulus ,S = I/y
taking Min MOI
= 13431.2727/431.5
=31.127 mm3
After Hood design modifications,
Max MOI- 4.706881366e+006 mm4 = 4706881.366
Min MOI- 1.364686572e+004 mm4=13646.86572
section modulus ,S = I/y
taking Min MOI
=13646.86572/431.5
=31.63mm3
Changes Done:
The gap between Outer panel and Inner panel has been reduced , tis induced the increase in section modulus,Thus the strength of Hood increase as well.