Indian Medical Devices Rules 2017: Chapters and Key Definitions
A free lesson from Skill-Lync's Regulatory Process, Standards and Certifications for Medical Devices course, on Grow by Skill-Lync · Last updated 16 Nov 2026 · Session: “Module 1 Session 1 - Overview of Indian MDR2017 Part I”
What will you learn in this free Regulatory Process, Standards and Certifications for Medical Devices lesson?
The instructor outlines the first six chapters of the Medical Devices Rules 2017, which took effect on 1 January 2018 and derive from the Drugs and Cosmetics Act of 1940. The lesson then defines terms used throughout, including authorizing agent, central licensing authority, conformity assessment, notified body and post-market surveillance.
- Six chapters of the Indian MDR 2017
- Roots in the Drugs and Cosmetics Act 1940
- Definitions such as authorizing agent and notified body
- Long term use means more than 30 days
What comes after lesson 1?
The next free lesson is lesson 2, “Manufacturing Licences Under MDR 2017: Forms, Audits and Timelines” (32 min). Later in Skill-Lync's Regulatory Process, Standards and Certifications for Medical Devices course (paid): lesson 4, Module 2 Session 1 - Overview of Indian MDR2017 Part II; lesson 5, Module 2 Session 2 - Overview of Indian MDR2017 Part II; lesson 6, Module 2 Session 3 - Overview of Indian MDR2017 Part II. The full course has 51 lessons (22 h 57 min of video); see the course overview or its price and syllabus.
Lesson transcript
Machine transcript of the lesson audio (lightly cleaned). Technical terms may contain errors; the video is the reference.
Hello everyone. Today we are going to talk about Regulatory Process of Medical Devices, Module 1, which is about the overview of Indian MDR 2017, that is Medical Devices Rules, 2017, Part 1. So, what this Part 1 actually consists of? The Part 1 consists of six chapters. The chapter 1 talks about the preliminary, which is majorly on the title, application and definitions, then the regulations of medical devices, wherein we talk about classification, grouping, essential principles, and also product standards. Then comes the authorities, who are responsible for maintaining this regulation in the country, in where they are involved in licensing, and also what are the officers who are controlling these activities, and also the accrediting notified bodies, which are responsible for auditing the Medical Devices Manufacturing Units.
Then the chapter 4 talks about manufacturing of medical devices for the sale and also the distribution within the country. So, what are the procedures, what are the forms, what are the legal obligation a manufacturer has to go through the authorities, the officers, and the bodies, in order to bring out the product in the market for sale and also for distribution. The chapter 5 exclusively talks about how to sell the products, once it is in the local market, how we can import this product and what are the requirements for the import of medical devices outside the country.
Then of course the labeling requirements, which need to fulfill all the products qualified to be sold in the country. So, through these contents, what will be our objectives of this learning? So, we will be knowing what are the medical devices, rules to them, sovereign which exists, what are the authorities and the functional bodies that are responsible for these medical devices to be in the market. And what are the roles and responsibilities as a manufacturer who wants to go through the regulations and also the procedures for getting the manufacturing license, test license, also import licenses.
Then finally the requirements of labeling for the medical device. So, this gives a comprehensive knowledge of what we need to go preliminary in order to get the medical device in the market as per the medical devices through 2017 in India. So, let us quickly go to the chapter 1 which talks about the preliminary. So, what this covers is the short title and the commencement. So, what is it called and from when it got into effect. Then the application part where it applies. Then the terms or the definition with respect to medical devices regulations wherein we use this term across all the modules.
So, that it is easy for us to understand in what context we are using this terminology. So, the short title comes as Medical Devices Rule 2017 or Indian MDI 2017. So, this rules has been coming to existence from Jan 1st 2018. So, the root of these regulations comes from Drugs and Cosmetic Act of 1940. So, what this Drugs and Cosmetic Act of 1940 covers are mainly the medical devices which are used for in vitro diagnosis, surgical dressings, surgical bandages, etc. Not only it is directly involved in diagnosis but actually it is also inclusive of all other mechanical contraceptives such as condoms, tubal rings, drugs, disinfectants and insecticides. So, these are the major things that are covered in this regulatory medical devices act wherein other devices that are notified in time to time apart from the above which I have stated here also will be part of the Drugs and Cosmetic Act of 1940.
So, now we shall see the definition. So, how will we see these terms? We will be seeing these terms across all the modules as I said before. So, that it will be easy for you to understand what context we are talking about. The first one is active medical devices. These are nothing but medical devices which need external source like an electrical energy and other source of energy to function. So, simple as simple as that. So, this medical devices need such kind of force to act in a human animal or any other bodies. Okay. Next is the authorizing agent. This is a person who is appointed by any foreign company as a representative to import medical devices from India.
So, this is the authorizing agent. So, this is the authorizing agent we are talking about. She will be the representative of the foreign company. I mean the overseas manufacturer. So, she will be importing the product and he will be duly licensed by the manufacturer there and he will have a registration of some kind here also. So, it will be taking place legally. So, he will be the representative for this manufacturer. Next is the body orifice as we already know. These are natural opening in the body. We know natural opening are like nose, mouth and ears but actually eyeball surface is also called as natural opening or any other artificial opening.
Some people may have struggling. Some people may have struggling following substances. So, that they will have a orifice in the neck. So, those are called tracheostomy. So, those are also considered as body orifice since for the rest of the time they will be having this orifice permanently. Hence, this also comes under this topic. Next one is the central licensing authority. Next one is the central licensing authority. So, this will be the only one that is nothing but the drug controller general of India shortly called as DCGI. This is appointed by the government of India. He will be the central licensing authority and everybody will be falling under this central licensing authority.
Next one is the central licensing authority. Next one is the conformity assessment. So, this is nothing but the examination of evidence. So, whatever the manufacturer is claiming as safe and very secure to perform a medical device, we need to perform certain examination in order to fulfill that requirement. So, whenever a manufacturer calls this device is safe for use, the conformity assessment, the conformity assessment will take place in order to ensure whatever the claim made by the manufacturer is true. Thus, it will also conform the principles of safety and performance of the medical device.
So, the license license. License here is very, very narrowed down to the licenses that is granted for various activities in manufacturing, sale and distribution of the medical devices. So, there are various forms like MD5, MD6 will be dealing in the further modules and details will be given there. So, those are called as licenses. So, this will be duly signed by the person who is the person who is getting this license. So, it is very confined to certain activities of medical devices manufactured. Next one is the long term use. The long term use is nothing but for any intended use, any intended continuous use of medical device more than 30 days. So, if it exists 30 days, then it is automatically called as long term use.
Next one is the medical device grouping. So, this is also an important criteria. So, the grouping, how it takes place. So, in the further chapter, we will be dealing the types of grouping the medical devices undergo in MDR 2017. But medical device grouping majorly tends to grouping of medical devices based on the intended use and the technology which is common between medical devices. And they can be classified into several groups based on their characteristics. So, intended use plays a vital part in grouping of these medical devices and also the technology involved.
Now, the notified body. This is nothing but, this can be a private corporate also or another legal entity which is registered under the rule 13 which we will be seeing in the upcoming slides. This authority will be given by the accrediting body to carry out the audit in the manufacturing side. Now, the client is using the Pioneer State's Strange Engine Engine Power to carry out the audit of the audit. Now, the participant is the first information on the eingele of the audit at the end of the unit.
In order to fulfill the conformity of the medical devices with respect to the standards. So, notified body are nothing but representative of the accrediting body. In order to ensure that medical devices manufactured in a particular site are going by the regulations, simple as that. So, the primary purpose of the notified body is to audit the manufacturing site and to confirm the safety and performance of medical device. Next one is post-market surveillance. So, post-market surveillance is nothing but once the product is in market, the product need to be analyzed again for its safety and performance.
So, whenever the product is out, there should be a process implemented into ensuring the safety and performance medical devices so that the product doesn't get outdated with the trend or any improvements need to be done or customer is facing anything out of the product that is in the market, this post-market surveillance will play a vital part in determining those. Predicative device. Predicative device. Predicative device is nothing but it's the first of its kind. It means there are no other similar devices with respect to intended use, design or material by which it is constructed.
So, it will be the first of the kind devices which does not have any predecessors or similar devices which has been done previously. It will be the first of the kind in the market, those are called predicate devices. These devices need to go through several tests and licensing in order to be in the market since they don't have anything similar to in the market. And of course, this is a novel device since it is the first in the market. Hence, safety and security of the user need to be ensured whenever there is a predicate device in the market.
Next one is the recall. Recall by its word not only includes the device that is marketed to be called back. It also includes removal of the medical devices and stopping of the medical devices at various level. At various level means when they are in the manufacturing sector or in the supplier or in the authorized agent, they can also do recall at various stages provided there is an incident reported on the medical device. So, such activities can only be taken there is a serious incident that has not taken place in the market.
Now that we completed the definition part, let us see the chapter 2 which deals about the regulations of medical devices. So, what this chapter 2 consists of? This consists of mainly four things. One is the classification of medical device which is very, very critical in order to place the medical devices on various categories on their risk-based classification. Next one is the grouping of medical device. So, this grouping is preliminary done by the government themselves. So, they publish these guidelines time to time in order to group these medical devices and they publish it online also in order to showcase the members so that where we stand in terms of guidelines for this device grouping.
Next is the essential principles for manufacturing medical devices. Again, this will be published by the Ministry of Health and Safety. Again, so wherever there is a change in the technology or the approach to medical device that shall be also notified by this Ministry in the websites. So, that everything is up to date in terms of medical devices. The last one is the product standards which are a requirement for medical device manufacturing. So, all the manufacturing of medical devices need to follow certain standards in order to qualify the medical device in the market.
So, these standards can be through certain agencies which provide standards or if there are no other standards exclusive for the product itself, the manufacturer shall set their own standards which shall be validated by the notified body or any other authority of the medical devices. So, we shall see in detail about these regulations of medical devices. So, the classification as I told you. So, there are four different types of classification for the medical devices as per part one of the first schedule which we will be seeing in the upcoming courses.
Next, in vitro diagnostic medical devices also classified under part two of the first schedule. So, there are four different categories based on the risk. Class A, Class B, Class C and Class D in which Class D being the highest risk and Class A being the least risk. So, how they are categorizing these four different types of medical devices? So, preliminarily, the central licensing authority will classify based on the intended use which is mentioned in the rule two. Next one is the very critical which is the sub rule three.
So, which basically classifies the risk based method of approaching these medical devices. So, the highest risk which the medical device can exhibit which can be categorized into Class D. So, these various classification are already published by the CDSCO. So, the CDSCO are the Central Drug Standards and Control Organization which have their website in which all the updates regarding medical devices classification will be posted in their site. So, as I told you, the Class D will be the highest risk and Class A will be the lowest risk.
According to classification method and the rule, these products will be classified. So, this will be studied in the upcoming chapters. So, just we can know that there are four different classes of classification of medical devices. So, these are some of the examples. Alcohol swabs and bandages comes in Class A. Invasive needles comes under Class B which are low moderate risk. And nebulizers and nebulizers and root canal devices also comes under Class C. So, the Class C and D are determined by various parameters. So, of course, there is a patient in the other end when we use the medical devices.
But the level of risk that this medical devices has and its involvement and intended use will determine whether it falls in Class C and Class D. Because these two categories are always classed under high risk. So, these are moderately high risk. Whereas Class D, by the diagram itself, it can show that it is high risk because it is very integral part of the body and without which there is a risk of fatality also. So, according to this, these products are classified so that whenever we are considering manufacturing these medical devices.
So, we need to take the precautionary steps and the licensing requirement from the first place itself. Because all the major, until and unless it is a predicative device, all the existing medical device fall under these four categories. So, accordingly, the risk of the manufacturer will vary. So, it is also very easy for the notifying or any authority to control the medical device according to its risk classification. Now, the grouping. So, the grouping is mainly issued time to time by the Ministry of Health and Family Welfare.
This is the Central Government Institute which regulates this grouping activity and they published this list now and then in their website. So, this is a very critical thing which is applied for import licensing, manufacturing sales and distribution licensing. So, this grouping is very, very critical in order to get the license for manufacturing of medical devices, also distribution and sales. So, what are these principles which are required for the medical devices? Preliminally, the principles are based on the safety and performance of the medical devices. Again, the Central Government Ministry of Health and Family Welfare.
So, I will summarize the mechanism of medical devices that I am going through the system. So, first, we will be able to control the technology that I am using. So, I will have to go with, so I think, so I will use the telephone to my medical devices. We'll do change this essential principle based on the contemporary scientific and technological knowledge. So, whenever there is an upgrade in the knowledge of scientific community and it has been published, the Ministry of Health and Family Affairs will take responsibility of amending these principles of manufacturing the medical devices. Sometimes it may be considered risky to manufacture certain medical devices. Hence, the Ministry will publish in such a way that this is stopped or recalled for future or if it is less riskier to manufacture medical devices, the Ministry of Health and Family Welfare will promote this activity in order to encourage the medical device production. So, it varies depending upon safety and performance of the medical device. So, now comes the main part. In order to manufacture any medical device, we need to perform certain standards. So, these standards, who will lay down these standards? So, for India, there is a Bureau of Indian Standards which has n number of standards for manufacturing a particular medical device. So, there may be a unique or novel medical device that has been done by the manufacturer.
So, no problem. So, that time the manufacturer may also set up a standard which will be evaluated for conformity by the notified body. So, there are two types of standards. One is already existing standards by the Indian standard, Bureau of Indian standards and also standard established by the manufacturer which in turn validated by this Bureau of Standards also. So, these are the standards in terms of India. But, there are other international standards which can be laid down for all the products across the world. So, mainly there are two organizations which heavily involved in deriving the standards for medical devices. One is the International Organization for Standardization that is ISO. Next is the International Electro-Technical Commission that is IEC. This is majorly involved in the instrument and software part.
So, other pharmacopinial standards are also there because this may depend on the type of medical devices which we are manufacturing. Hence, the standards applied accordingly. Hence, the standards will be an important requirement for any medical device manufacturing. So, all the manufacturing should be carried out by the standards in order to fulfill, in order to ease the workload of the authorities to examine your processes. If you confirm that these are made by International Standard or Bureau of Indian Standard, it will be very easy for the authority to confirm the product being carried out by safety standards. Or else, if you are producing any novel standard, it has to be validated again. If it is validated, fine. This will be the new standard for the upcoming products in the same lineage. Hence, product standards are an inevitable part. So, that concludes the chapter 2 of this module. Now, let us see the chapter 3. What are the authorities, officers and the various bodies responsible for medical devices manufacturing? So, this chapter predominantly deals about who are the licensing authorities who are responsible for, of course, giving the license for various activities of medical devices manufacturing.
Then, not only the licensing authority will themselves only give the license, they can delegate their power to other authorities in order to other authorities in order to get their recommendation for licensing. Since India is a bigger sector and we do not have that much of licensing authorities across all the places. So, there is a delegation of power to certain authorities by this licensing authority in order to carry out this licensing activities with ease. Again, they will appoint certain controlling officers in order to execute these activities. So, that comes the next part. And also, there are national accreditation bodies which accreditate this notified body which we learnt in the previous section to carry out audit in the medical devices manufacturing sector to ensure the safety and performance of medical devices. So, these accreditation bodies also we will be seeing and what are their functions. Then, what this accreditation body does to notified bodies and what are the powers that the notified body has, we will be seeing in the rule 13. Again, in the rule 14, we will explain about the duties of the notified body. Again, the procedure which has to be adopted by the notified body in order to ensure the conformity has been reached. Then, what are the fee structures with the notified body can charge.
Then, finally, whether the notified bodies are qualified enough, where they are licensed, they have to get the license from the accreditation body. What are the rules they have to follow in order to have the registration going for themselves. Then, the medical testing officers and medical devices officers. So, what is the difference? And these people will be from the notified body to carry out all the activities required for conformity of the assessment. Next is the central medical device testing laboratories, which are required as a part of samples need to be sent and ensured that these are serving the requirement as per the manufacturer's claim. So, all these topics will be dealt here under now in the chapter 3. So, the licensing authority, the central licensing authority.
So, we learnt about the central licensing authority, which is nothing but the DCGI or the competent authority for putting all the rules related to import, manufacturing, clinical investigation, clinical performance and coordination with the state authorities also. So, all these activities will come under the central licensing authority. So, they will be the ultimatum for all the activities carried out by the medical device with respect to import, manufacture, clinical investigation, clinical performance and also coordination with the state licensing authority. So, all this activity directly falls under the licensing authorities. So, for central, it's a central licensing authority, as well as for state. If the state is a licensing authority, again, the central will coordinate with the state licensing authority. So, if there is something related to the sale and manufacture of medical devices, the state licensing authorities also has a particular set of regulation in order to sale or distribute the medical devices. Mostly, it will be same as the central licensing authority. So, this will be effectively coordinated again, what we saw in the rule seven. So, the last point will be the coordination of the state licensing authority. So, there, central licensing authority in some cases or many circumstances, they can delegate the power also to the state licensing authority in order to establish licensing.
So, as I told before, the central licensing authorities can give in writing and delegate powers to other officers or organizations. Okay. So, when it comes to officers, so the EAD, usually we call as assistant ranks controller. So, the person who is in those ranking and above him are being interested with these powers for issuing the license. So, what this person will do once he gets the power, exercise the power is like, he will be licensing authority in name of the central licensing authority. So, he will be issuing those things by the power entrusted by the central licensing authority. So, this is the main delegation of power which we were talking about. So, this controlling officers who are nothing but this officer who has been dedicated the power and they will be executing the activities as per the regulation. So, all the functions which is subordinated by the central licensing authority, the drug controller general of India, DCGI, authority. That's what the central authority is. So, what they will do is they will interest this power and all the controlling officer will be ensuring that these functions have been carried out properly by the manufacturer. So, now national accreditation body. So, what are these? These are nothing but the designated institute or a government agency.
The designated institute or a government agency. Which will aid the notified body in order to ensure the performance compliance of all the medical devices manufacturers. So, they will have N number of competent person for performing this function. That means, the national accreditation body shall have some representative who will be entrusting certain activities to notified bodies, which will in turn audit the manufacturing unit so that all the performance and safety standards are met by the manufacturer. So, the notified body will give the recommendation to the accrediting body in order to fulfill the licensing or any other standard approval required for the manufacturer.
So, this will be predominantly central government organization. So, they will be responsible in giving the license to the notified bodies. So, again, all the things which I spoke now are mentioned here in this slide. So, the national accreditation body will be carrying out the assessment of the entity which applied for the accreditation, issue a certificate to such entity in respect to specific categories of standards for which such entity has been assessed and found qualified. So, this can be directly done by the national accreditation body or through the notified body, but the accrediting body will not act as a notified body.
So, the notified body will be under the control of accrediting body in order to check the performance compliance of all the manufacturers of medical devices. So, this is exactly the function of national accrediting body. So, they will be having the conformity activities and they lay down the standards for all the accreditation. So, this will be ensured by the notified bodies to prepare procedure based on the accreditation given by the national accrediting body. And what they will do is, they will ensure that the notified body is periodically assessed in order to fall under the conformance of the accrediting body.
So, not only this directs the notified body, also keeps in check that these notified bodies are up to date so that they are carrying out the activities as suggested by the national accrediting body. So, shortly, this accrediting body will be the controlling body for notified bodies. So, in order to issue a certificate or execute a performance conformance assessment, accrediting body will direct the notified body in order to ensure these are achieved properly. So, now, what are these notified bodies will do as directed by the accreditation body?
So, these are nothing but the corporate body, this can be a private body also, which will seek the accreditation from the national accrediting body in order to carry out the audit in the manufacturing sectors. So, that the conformity assessment has been ensured by the manufacturer shall be checked by this notified body. So, once the notified body gets accreditation from the accrediting body, they will really really carry out the audit for the class A and class B of the medical device to verify the conformance. So, once they register with the central licensing authorities and they carry out the audit, they will recommend the central licensing authorities to qualify this manufacturing unit to manufacture medical devices.
So, in order to do that, they have to first register their validities for two years, then they have a special form called MD1. So, if you want to be a notified body, you need to qualify and register yourself into the national accrediting body and what are the things needed needs to be full feed to registration by MD1. So, through the online portal, there are a couple of fees also in order to qualify to be a notified body. So, this is the outline of the form which is available online, which you can get it from the CDSEO website.
So, it will have all the details in order to register yourself as a notified body. Again, you have to go through certain pre-qualification in order to be as a notified body. So, after your application, so what happens is the central licensing authority will examine the file. So, whatever appeal you are making and they will revert to you back within 45 days. So, whenever the application is made, so notified body will issue a registration certificate in form MD2. Once the notified body has registration with the accrediting body, the registration certificate will be issued by the accrediting body.
So, once the registration certificate is issued, hence the notified body will be qualified to perform the roles that has been entrusted to the notified body. So, this has some validations also. It is valid for two years and it has to fulfill all the regulation and conformity which a notified body has to undergrow. So, if it misses certain rules or any registration fees which need to be provided initially once the registration certificate has been issued. Again, this registration certificate also will be cancelled. So, notified body has to be vigilant about this registration certificate.
So, that once the rejection has also appeared, they can reappeal but they have to make sure in the first place that they get the registration as and when the central licensing authority registers for the certification. So, this is the MD2 form for the notified body so that they get registered and they are good to perform the audit. Now, once they got the registration, they are officially notified body. So, what are their duties? The preliminary duty of any notified body is to conduct the audit for class A and class B.
So, this audit will be carried out as per the regulation and procedures which the accrediting body has already laid down. So, they will conduct this audit to the manufacturer whenever the manufacturer appeals to notified body and they calls for the audit in order to get the conformity of the assessment. So, there are specific application again alerted by the state authorities so that they go into the portal register and call for the audit. Again, this audit shall be only made with respect to domestic manufacturing site because the regulation applies only to the local area.
If it is state compliant, we have to do it in the state. So, that the manufacturing site for class A and class B medical device complies with the respective relevant regulations. So, the notified body, once they conduct the audit in the domestic area, in this case, it is the central area that India, outside India, it cannot apply. So, that is what they are meaning here. So, that once a notified body is doing the audit, they shall have a standard operating procedure. They will identify, review and resolve any cases of a conflict that the manufacturer is claiming to have.
Once they found it, it is responsible to the notified body to record and they have to make a decision based on the evidences. So, first thing they have to conduct the audit. The audit has to be as per the rules and it should be domestic manufacturing area. Then they will provide identification, review and resolution during the course of audit and they will record those activities. And finally, they will come up with the plan of actions and decisions made based on the observation. So, what are the procedures they will follow?
These are in detail in part two of the third schedule. But anyways, the major parts that they will do is, first is the technical review of the respective documents, especially the documents which pertaining to the quality. The quality manual, the policy, everything. Then the quality QMS is the very major thing that needs to be reviewed by the notified body. And they should be checked with the complaints with the standards. So, again, they have to collect the evidences wherever they establish the conformity of. So, then we will do it in detail.
So, we are going to come up with the monitoring and report through the control results. So, this is our date. So, there's nine months after a draw and we will be available at the recipient of the So, this is what we are going to take. So, if we are going to go through their visibility. So, there's the four others have to be a성 of this thinking that we want to make of the examination. So, wherever they say that it's okay, whereas a notified body is concurring, yes, they are following, they should collect the evidences to back their claim also during the audit. So, again, the preliminary quality design documents during the assessment. So, they have to take the samples and do the required examinations. And also, they have to record this, all these post-approval changes also.
Again, the assessment conformity of the product and the process standards as per provisions of these rules also need to be followed by the notified body. Now that they completed the audit, everything is fine. It is the responsibility of notified body to inform the manufacturer about the observed. If there are no non-compliances, fine. They have to say there are no non-compliance observed or if non-compliance is observed. So, they have to inform the manufacturer, they have to inform the manufacturer and they have to give the audit report copy with the evidence showing that it is non-compliant. So, whenever there is a non-compliance that it is a non-compliance, it is a non-compliance. So, it is the responsibility of notified body to identify what is observable or rectifiable non-compliance, inform the manufacturer to rectify it in due course of time so that it becomes compliance.
And they can recommend for certification to the non-compliance. So, it is not only finding the non-compliance but also giving time to the manufacturer to rectify it. This is the main tool of notified body again after the audit. So, once everything is done, they are given the information to the manufacturer. So, they have to give this report whatever happened to the state light sensing authority, whatever audit copy and the non-compliance observed and a copy to the manufacturer also about the audit. In other terms, in other terms, they have to be totally transparent on whatever they have done in terms of audit for the manufacturing sector.
They have to give the same information to the state licensing authority as well as the manufacturer in order to comply with the manufacturing procedure. Again, notified body does not come for fee. We have to have some fees for the applicant to the services rendered. Again, these fees are, again, they are just made by the central government, how we have to charge them and everything because the service is little costlier. Hence, hence, there will be fees charged by the notified body in order to perform this audit.
So, now that the notified body has performed a roles and regulation, it is the responsibility to notified body to renew their registration now and then and also comply with the requirements of the updating body during their tenure of registration also. So, if they are not complying with any of the rules laid by the accrediting body, there is a chance of cancellation of or suspension of the registered certificate of the notified body also. So, whenever we are checking with the notified body, we have to ensure that they are not getting any sorts of suspensions or cancellation in their tenure of activities.
So, again, this rarely happens because notified body usually will comply with all the requirements of the accredited body. If at all something happens, they can reappeal to the central government and the central government can also like give an opportunity to revert back all these cancellations or suspensions. So, again, they will do some verification and audit activity in order to restore the registration done by the notified body. So, again, if the registration timing like two years has been expired, the responsibility of the notified body to renew their registration with the central licensing authority or else the licensing authority is deemed to again cancel.
Because of expiration of notified body. Again, this two years tenure, they are doing it because of the increasing technology that is happening in the medical devices. They have to be up to par so that all the activities carried out in the audits are up to date so that they have to refresh their way of assessment based on the new standards. There are new versions of standards comes yearly basis or also whenever there is a requirement. So, this notified body's responsibility to be at par and also they have to be registering again and again with the central licensing authority in order to ensure that they are competent enough to do the audit.
So, there are two main people which are involved in audit activities who will be representing this notified body. One is the medical device testing officer. The other one is medical device officer. So, the major difference is again the testing officer usually performs a testing of wherever the sample has been taken and the medical devices are obviously act as an inspector for the medical devices. So, this is the main differences and these people are designated by the central government in order to carry out. So, if there is an activity which need to be ensured or tested, these people will be sent and the samples will be sent to them for testing or they will take the sample themselves during the audit and they will ensure that all activities are performed under the compliance of medical devices regulation 2017.
And the sample qualifies through the testing and it will be inspected by the officer also and ensure that all the performance complaints are taking place as per the regulations. So, now that we saw the chapter 3 and their importance, let us move to chapter 4 in the next segment. So, this is the kypenic Agora but for everyone, we don't know that the answer is at all, so they just want to look like the prawn spaces are coming by for a moment. All, let us check that out, so the limits are coming.
There we are looking at the user taken care of course and again we're only going to see under the nickname Landesregierung where we are coming.