← Previous lessonFree lesson 3 of 3 · lesson 3 of 48

Unlock all 48 lessons of Design of Sheds with GantryFull course ₹40,000 · paid

Price & syllabus
Free lesson · 33 min · no payment

Bracing Patterns, Crane Girder Supports and Vendor Drawings

A free lesson from Skill-Lync's Design of Sheds with Gantry course, on Grow by Skill-Lync · Last updated 16 Nov 2026 · Session: “Designing Gantry Structures: Bracing Patterns in Steel Gantry Structures”

What will you learn in this free Design of Sheds with Gantry lesson?

The instructor compares concentrically braced frames (X, diagonal, V, inverted V, K) with eccentrically braced frames, and explains braced bay placement and expansion joints, citing 230 m for a covered building under IS 800. The lesson then covers crane girder sections, lateral horizontal trusses, crane stops and how to read crane vendor drawings.

  • Concentric versus eccentric braced frames
  • Placing braced bays and expansion joints
  • Crane girder sections and lateral trusses
  • Crane stops and vendor drawing data

What comes after lesson 3?

Later in Skill-Lync's Design of Sheds with Gantry course (paid): lesson 4, Design of Gantry Girders; lesson 5, Specifications and Selection Criteria for Crane Rails as per Indian Standards; lesson 6, Design of Gantry Girders: Detailed Overview and Calculations. The full course has 48 lessons (21 h 46 min of video); see the course overview or its price and syllabus.

Lesson transcript

Machine transcript of the lesson audio (lightly cleaned). Technical terms may contain errors; the video is the reference.

Hello everyone. I welcome you back to the course, first week course on Design Shelter with Gantry. Now in the first session of this course, in the first two parts we covered introduction of Gantry structures or steel with Gantry structures, different components of the Gantry structure and also basic geometry patterns we discussed like column spacing, orientation of column, base, base split configurations, roof slope, all these things we covered as of now. In this third part of the session, we will be discussing the remaining parts and the first one is bracing pattern. Bracing serve of mainly two types. One is this concentrically braced frames and second one is eccentrically braced frames. Okay. First we will go with concentrically braced frames. We will discuss about this. In concentrically braced frames, bracing serve connected at the main joints in the structure.

They are joined at the beam column junction. Bracing are connected at the beam column junctions or even if it is connected at the beam also, both the bracings will come and join at the same working point or same joint. In this one, because of bracing joints are same, there will not be any residual movements in the mainframe columns or beams. It provides very good strength and stiffness at very low cost. Because of this bracing joining at the same locations, we can have very small size beams or small size columns and all entire lateral loads and even the vertical loads will be transferred through these bracings to the foundation.

So, it will bypass the load transfer from the main beams and to the foundation. So, it will bypass the load transfer from the main beams and columns through these bracings and to the foundation. By this way, we will get very economical column and beam sizes. But the other part is because of this, the structure will be very stiffer one and it will be rigid and because of this, ductility will be very limited in concentrically braced frames and also it has some difficulties in architectural planning also.

Now, we will see different types of concentrically braced frames. The first one is X braced frame. You can see bracings are connected in X shape and the next one is diagonal braces. These two are both diagonal braces. Compared to these two diagonal braces frames, X bracing will provide more stiffer and it is preferable in high seismic zones to have X bracing because in seismic zones there will be chances of stress reversals and these X bracing will help in having more ductility in case of stress reversals.

And then we have V type bracing and then we have V type bracing. Inverted V type bracing also we call this A type bracing also we can call and then we have K type braces. In all these things, if you can observe in V and A type bracing or inverted V bracing, beams or bracings are connected to the center of the beams. Because of this action, forces will be transferred to the beam and from beam to the column bracing junction. So, there will be some forces in the axial forces in the beams as well, these tie members as well, in this type of arrangement, bracing arrangement.

All these aspects, load transfer phenomena or when we need to go for A type bracing or V type bracing or X type bracing, all these more details we will cover it in the further sessions when we discuss, when we go into the detailed design part. Which one is preferable in which case, all those things we can actually see with examples, we can go ahead. One aspect of I can tell in which shape we can go for based on the shed height and column spacing is the angle of inclination of the bracing with the horizontal.

It is ideally, it should be around 45 degrees, say maybe 30 degrees to 60 degrees also we can provide. But, if it is more steeper, then we need to change the bracing arrangement. We may have to go for X type bracing or in some cases, we may have to go for A type bracing based on those angle of bracing. You see in this, this one is just representation principles I have given, but these bracings are very steep, the angle of inclination with the horizontal is very less.

These type of bracings, we should avoid it, because in this bracing, the major load will be in the horizontal direction, it will not transfer forces properly. So, even the connections also will be very difficult. We need to provide a gusset connection, very big gusset connection for this one. So, these type of restrictions, we need to consider before selecting the proper bracing pattern for our particular case. And then, we have another bracing type, eccentrically braced frames or and neve braced frames. So, in this eccentrically braced frames, bracing members are arranged so that their ends do not meet concentrically on a main member.

Rather, they are separated by a small margin and this part of this will act as a ductile link. So, what is ductile link? Because of this ductile link, what happens is, when there is earthquake forces, which are actually more than what we consider. The structure, because of this weak link, will yield first. And this is a small link. Because of this yielding, structural ductility will be very more. And this, because of yielding, there is lot of energy dissipation in the structure. And the structure will perform better in case of seismic, high seismic forces.

So, that's why, eccentrically braced frames are suggested and recommended also in high seismic zones. But, as far as sheds with crane girders or open sheds without crane girders, these have very less seismic mass. Hence, the lateral loads, when compared to the wind loads, will be on lower side, even in high seismic zones like the seismic zone 4 and seismic zone 5. So, these eccentrically braced frames will come into picture mostly in the structural buildings, not like shed type structures. But, we can say multi-story buildings or buildings which have marginal floors or intermediate floors with concrete slab.

Where we have, because of that concrete slab, seismic mass will be high. And in these cases, it is preferred to go with eccentrically braced frames instead of concentrically braced frames in high seismic zones. Especially in seismic zone 4 and 5 as per Indian point of view. Now, you can see the pictures. The first one is inverted V-shaped bracings. Here, you can see there is a small gap. Both the bracings are not connected and there is a small gap. This gap is called weak link. And, this link will act as a ductile yielding element during high seismic.

So, this will allow the dissipation of energy by yielding during high seismic actions. That's why these bracings patterns are preferable in high seismic zones. I hope you understood the difference between the concentrically braced frames and eccentrically braced frames. Now, we come to the bracing base. I have shown you couple of stratified cells in the last sessions. The bracing frames, we generally provide at least two bracing bases in a normal shed type structure. Say, anything above 50 meters or 50 meters to 100 meters. Which generally provide at least two bases along the length of the shed.

It also depends, the number of bracing bases also depends on the wind velocity or wind zone, wind loads. And, also seismic loads in case of, if the structure is high seismic zone and there is a high seismic mass is there. In that case, even seismic loads will govern the bracing pattern. And, also if we have a very weak foundations, means very weak soil, then having only one more two base of braced bay will lead to the entire horizontal force will be transferred to that base only.

And, because of that high horizontal forces, there is a chance that we may not accommodate the footings at that location. So, we may have to add another bay or two base of vertical bracing and plan bracing so that horizontal loads will be evenly distributed throughout the length of the building. I will show the strat model to discuss this point again so that you can understand it better. You see this strat file that we discussed in the earlier parts of the session. In this strat file, we have three base of bracings.

This is like almost like 70 to 80 meter length. We have provided the bracing at different locations. We can move these bracings here and there or located. At least, it is ideally bracing should be provided at the ends, not exactly at the ends. At least one. Alternative to the end, may be in this here. Also we need to look at the service point of view or the occupancy point of view so that there will not be any pipe entry at the bracing location or vehicle entries. We need to check that one and avoid those bays for bracing planning. Those wherever we provide the vertical bracing or horizontal bracing, the base should be clear of any equipment or for any future point of future maintenance requirement point of view.

We should need, things need to be taken care while deciding the braced bay positions. We will go back. Another important point in that affects the bracing pattern or bracing bay's location is the location of expansion joints. Expansion joints are provided so that the building will expand it freely due to differences in temperature without causing any internal forces in the building. As per IS800 code, when the buildings or size of the building exceeds 230 meter for covered building, one expansion joint shall be provided. If it is not possible, then we need to design the structure for temperature loads as well.

And for open type of structures, where it is not covered by side seating like pipe racks and everything, this expansion joint shall be provided every 150 meter length. And expansion joint also provided whenever there is abrupt changes in plan of the building. Like in some places, like in some places, the width of the building is changing from 30 meters to 10 meter at one place. It is preferable to provide expansion joint at these locations so that building will behave properly and there will not be any horizontal torsion because of these differences in plans.

And we will see what the Indian clauses are saying about this. Now, you see in this picture, question of bracing from expansion joint shall not exceed 90 meter, okay, from either end. And here, two base of bracings are provided for entire length of 230. So, these are the minimum two base of bracings shall be provided for 230 meter length of the covered building. But we may have to, in practical, we may have to provide some additional bracings to transfer the lateral loads effectively through the length of the building.

And this clause is again for covered building. If you are having only one bracing, then the maximum length of the structure without any expansion joints is only 180 meter. Now, coming to the next part of the course, in this session, we are also covering, we are also discussing about the crane supporting arrangement and crane vendor drawing details. So, this is a sample stair models. In this, we are showing the roof is not a portal frame, it is a roof truss type brayer. You can see the plan bracings also and even the vertical bracing here.

There are two base of vertical bracings are provided, each at the ends of the, which is actually preferable. And even the plan bracings also, the continuous plan bracings are also there at the top. Then, you can see one more thing. There is a one crane girder lateral lattice girder arrangement is there. This horizontal truss arrangement is to provide lateral support to the crane girder. I will explain you better way. These are the typical crane supporting arrangements based on the capacity of the cranes. So, if you have, say in this case, the crane capacities are less, say 10 tons only, 2 tons, 5 tons, 10 tons only.

We can have a simple bracket type connection for supporting the crane girder. And it can be laterally supported at the column locations. If the column spacing is very huge, then we may have to go for another eye section to increase the lateral capacity of the crane girder. And for a little higher capacity of cranes, say 50 tons, say about 50 tons, we may have to increase the column size also. Or we may have to provide a laser type column or batten type columns, wherein the crane girder will sit on part of the column.

For a very heavy cranes also, that is very much needed. But in some industrial practices, these columns may not be possible to provide at all the location. But it is always preferable for a very heavy cranes to have arrangements something similar to this. Now, proper crane girder beams profiles. Generally, all the crane girder will be basically I sections or W sections. And this will be with a rail type arrangement, where on this rail, the crane gantry will move. Gantry wheels will move. This arrangement is similar to the normal railway wagons moving under rails.

But again, when the lateral, when the crane capacity is high, because of this transverse loads, this crane girders needs to be stiffened in the lateral direction as well. To take care of the compression forces at the top flange and lateral forces from the moving crane. For small type cranes, we can actually go with the simple I section columns, I section beams for a grain girder. For real, say 10 tons or 15 tons or 20 tons crane girders, crane capacities, we may have to use, we may have to stiffen the top flange, which will be under compression in the center of the beam, center of the girder.

And the bottom flange will be always under tension. So, the flange will not buckle in tension, but the top flange, which is under compression at the mid-span of the girder. And because of that high compression, if there is no lateral support, the top flange may buckle. And to avoid that, it is preferable to strengthen that part of the flange. Instead of the whole section, it is economical to provide only to strengthen the top part of the flange. If we can strengthen this by providing a channel section like this, and also we can provide a double angle sections on both sides of the flange.

But this is the most preferable one. And these are the roll sections and this is the plate girder type. Instead of a standard ISMB sections or ISW sections of American standards, you can use a plate girder type also. If the sizes of the standard sections are not possible because of high loads and larger spans of the crane girders. And this is one more type of crane girders built up section, but with top flange is replaced by a channel section. This will again give the higher strength in lateral fixability at the top flange, which is under compression.

Again, sometimes when for say 50 tons crane girders or 100 ton crane girders, the horizontal load at the top flange is very, very huge. So, even with the channel section, it is not economical to keep on increasing the thickness of the top flange or providing the channels may not be sufficient. And for a larger span crane girders, we may have to provide a horizontal truss to provide lateral stability to the top flange of the crane girders. And these are the two arrangements, typical arrangements. This is a continuous plate, it will provide some sort of lateral stability and then we can have a continuous gusset plate with a horizontal bracings also.

That what we saw in the earlier STAD model of picture here. You can see these are the STAD, actually a horizontal truss is provided to the crane beam or crane girders to the structural beam. This, along the column line, there is a structural beam is connected and between these two, there is a horizontal truss type arrangement is given. The truss type arrangement will give lateral stability to the crane beam and it will not allow large deflections in the horizontal directions. It will take care of those lateral stability and lateral strength for the crane girders, which is normally weak in minor axis direction.

That is why this is very important for, at least for the large crane capacity sizes. And also, this one, for large crane capacity, we require a maintenance platform also at the top. So, that this will act as a dual purpose for both for lateral stability and for a platform, maintenance platform also we can use this one. This one, again, I am showing this a typical, not a typical one, but one of the crane bracket arrangement come and plan horizontal truss arrangement we are showing. Okay. This is for a 100 ton crane in a thermal power plant building.

Here you can see this is the column size of 1200 and there is a small bracket projection of 550. They have given a cantilever beam and on top of it, this is crane girder is 1400 deep crane girder. These are spanning actually about 12 meter spanning is there and it is a 110 cranes. That's why we are, we need to have a such deep crane girder beams. And further, top flange definitely has to be provided with a lateral truss, horizontal truss to have a good lateral stability.

Here, that truss is provided here. This is a I-beam that is connected from the column column, main building column to column. So, this will act as that one. Again, as shown in the start file, this is the actually part plan showing the horizontal plan bracing of the crane girder. This CGA1 is the crane girder and this is the actual, there will be a platform also is there and UB533 is a member connecting. These two columns and this there will be a horizontal bracing pattern so that it can have a little stability. We are all showing these typical drawings so that you can understand the how the drawings needs to be prepared how the drawing looks final output looks and when you go into the detail designs then you will appreciate all these things then you will get to know more details how to design all these aspects all these components of the platform.

platforms, lateral horizontal trusses everything. Then another important aspect which we generally ignore but it is very important to consider is the crane stops. So what is crane stops and what is his use? Why it is so important? The main function of crane stop is to be able to sustain medium impact without appreciable damage to the structure or to the crane girder itself. This crane stop must be capable of sustaining the load and the full impact and preventing the crane from leaving the runway. We know these are all electrically operated cranes and operation will be done manually. So we need to move the cranes from one side to the other side.

During the operation if the man who operates the crane if he fails to stop the crane at the end and if there is no stopper at the end of the crane girder the entire crane will move and fall down from the end of the crane girder. This will have devastating effect on the personnel and on the safety of the structure overall also. So that is why this crane stop needs to be considered very seriously and we should not ignore this crane stop details. This actual this aspect is generally ignored by all the engineers and what they do is they do the structural design perfectly. They do the crane girder design also perfectly but they ignore the importance of this crane stops.

These are the typical details. For a small capacitive crane stops something looks like this. For a higher capacitive crane we need to have something like slot beam flange. Some bolts will be kept to keep this flange type arrangement intact with the main girder so that it will not fall down and it will not move this stop arrangement also. And also there has to be some ductility type arrangement also has to be so that it can absorb this moving impact without damaging the main structure and crane beam as well. These are the typical arrangement. This one more item it is there is one wooden block also can be given like this. What this wooden block helps is to absorb the energy and dissipates it. This moving crane it acts as a dissipation energy.

So it will instead of a steel and it will instead of a steel and the wooden block will help it so that it will have absorption energy and it will dissipate the this energy moving kinetic energy and then in coming to the crane vendor drawings. These are the crane vendor drawings are the drawings which are provided to us the civil engineers so that we can take the appropriate loads onto the crane girders and onto the main structure based on these crane vendor drawings. Crane drawings are like single girder EOT cranes and single girder under slung EOT cranes. What you mean by single girder is for lower capacity cranes say up to 10 ton or even of sometimes up to 15 tons also there will be only single girder supporting the crane motor and grab arrangement hoist only there will be only one crane girder will be there this one and it is supported two wheels on two wheels on each side. These wheels will move on the crane rails or in case of under slung EOT cranes these wheels will move on the bottom flange of the beams.

These type of under slung cranes we will not see in the shed type structures but in some arrangements in some type of building structures in some floors these type of cranes are also used. I have shown this one also so that you will not be surprised when you come across this type of under slung EOT cranes. So here also under this is overhead single girder EOT cranes. Here also you can see there is only one girder is there on which motor is there and there is a small working frame will be there on which you can have electrical cables and platform also will be there but this is basically a single girder crane gantry or you can say.

And then we have double girder EOT cranes where weight of the cranes lifting capacity is very high. So you can't have a single girder. If you provide single girder then that depth of the single girder has to be very very high and also the motor since the motor capacities and width of the size of the motors are very high. You can't support every machinery equipment required for that operation for movement. You can't support it on the single girder. So you need to go for double girder. Here you can see there are two girders. One girder is here one girder is here on which all motor all other associated equipments are supported here and this one will go and at the ends it will go and support it on the rails.

And this entire gantry system will move on the rails. And these are typical data they provide from the vendors. This I have shown from standard typical catalogs. I have taken this snaps and I am showing here. So these are the typical 30 ton capacity lifting weight is there based on the spans of the rail to rail span. This is the rail to rail distance is the span based on different spans height of the clear height that also need to be considered because based on that the roof framing arrangement that column height will be decided and we also need to have a clear height for lifting height from here to the ground level. That also has to be there but that is to be designed by the architect or mechanical piping requirement based on that requirement that will be given.

Given that height of the minimum hook height will not be given by crane window. And there will be some other parameters like S3, S3 and minimum edge distance from the crane rail to the hook. So that this hook will not move further from here. It can come only up to this place. So you can't lift some equipment is there from this location. You can't lift using that hoist. Based on that we need to actually place the location of equipment ground floor or any measuring floors. We need to place those position of those equipments also accordingly. So that it can be lifted and more for maintenance purpose or replacement purpose as well.

Again this is one more typical detail from the crane window drawing. All these things we need to have study. Here you can see there will be a distance top of rail from the floor, finished floor level. This also we need to find out. And there is one more item is lift. This lift is actually more important. Based on this lift this top of rail will be decided. If we have to lift minimum height of let's say 5 meter based on this 5 meter this HR dimension will be provided with the crane vendor.

And based on that we need to find out. And based on that we need to design the top of rail level after getting to know the crane girdle design also. Before that we need to design the crane girdle and we need to arrive at the probable depth of the crane girdle. Based on that we can arrive the top of rail. And after the top of rail there is one more factor called H1. This factor is clear distance from the top of rail to the roof. Based on this H1 distance we will decide the roof height.

So that if there is any rafter plans we need to plan accordingly on this. At least column should go up to this point. And then only rafter will start moving or even the roof truss. So the clear height shall be compulsorily maintained. These are all different of sample only it is given. And then there is one wheel load component is also given. Based on that there are so for this crane on the side there are two wheels on each side of the rail. So maximum load on the wheel they generally provide in the crane vendor drawing. Based on this we can actually arrive at the maximum forces in the crane girdle and design it the crane girdle accordingly.

The design of crane girdle will be covered in the next few sessions. So more details about this loading, wheel load, wheel load locations everything will be covered in there. So from crane vendor drawing we need to take the crane capacity and span of the crane wheel base so that we can do the crane girdle design accordingly. Similarly the type of girder as I explained earlier. Single girder or double girder crane. Maintenance platform requirements. If there is any maintenance platform is required then we need to have a minimum width of the platform and also clearance height for maintenance platform.

The men has to go there. So at least 2.1 meter height clearance shall be there to the roof of the structure from the maintenance platform. These all the things we need to consider before deciding the crane girdle support arrangement roof height also. So So So Summary of this session, complete week's session. We discussed this completely in three parts. In the first part, we covered introduction part and what exactly is the gantry structure looks like that we note. And then we coming to the geometry of the crane shed with gantry, columns, spacings, we discussed what are the governing factors in deciding the column spacings, orientation of columns.

So, orientation of main columns, orientation of gabeland columns that we discussed. The thumb rules for member sizing, which is basically applicable for beams and even for purlins also we can use those thumb rules. In case of columns, if there is only axial loads, there is some formulas are given. So, we can refer to those and decide we can arrive at the preliminary column sizes as well. If the moment is also governing for portal frame type, then the column sizes we can go, initial sizes we can arrive based on the beam sizes. At least, the column size shall be equal to the beam sizes.

Then we also discussed about the slope of the roof, different types of slopes and the advantages of cambering effect because of that slope and minimum angle of the slope to be maintained based on different factors that we discussed. And important topic of base plate configuration, how it affects the structural arrangement itself completely and even the deflections, all those things will mainly depends on the base plate configuration. And also, another important topic is basing pattern, where we need to keep the bracings, how many base we need to have, what type of bracing pattern, X bracing, A bracing, inverted A, V bracing, V other concentrically braced frames or eccentrically braced frames.

All these things we have discussed and crane supporting arrangement, crane vendor drawing study also we covered in this part of the session. So, hopefully you can now say that basic, you can now say that you know the what exactly is a steel shed with gantry structure, how it looks like, what are the main components of the sheds, this structure types and what are the governing factors which we need to take care while deciding the general arrangement, framing arrangement and what are the other safety factors that we need to keep in mind before proceeding for the detailed design and the next sessions we can cover more detail into the particular design things.

So, thank you everyone. Bye.

Want the rest of Design of Sheds with Gantry?

Get the full course syllabus and fees.

The full course is paid (₹40,000). We'll send the syllabus and call you back within one working day.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Full course · paid

Unlock the full Design of Sheds with Gantry course

The remaining 45 lessons, mentor-reviewed projects and a certificate come with the paid course (₹40,000). Leave your details: we'll send the syllabus and fees and call you back.

Get the syllabus and fees

A counsellor calls you back within one working day.

By submitting you agree to our Terms and Privacy Policy.

Grow by Skill-Lync · free lesson

Start watching

Free, no payment. Leave your details once and every free lesson on Grow plays straight away. A Skill-Lync counsellor may call you about the full Design of Sheds with Gantry course.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.