The instructor gives thumb rules for initial sizes of beams, trusses, columns and purlins, then explains how rainfall, dust and cladding set the roof slope. A 2D STAAD comparison of cambered and flat frames shows 97 mm against 120 mm deflection, followed by pinned, fixed and one-axis fixed base plates, anchor bolts and shear keys.

  • Thumb rules for beam, truss and column sizes
  • How roof slope and camber reduce deflection
  • Pinned and fixed base plate arrangements
  • Anchor bolts, pipe sleeves and shear keys

What comes after lesson 2?

The next free lesson is lesson 3, “Bracing Patterns, Crane Girder Supports and Vendor Drawings” (33 min). Later in Skill-Lync's Design of Sheds with Gantry course (paid): lesson 4, Design of Gantry Girders; lesson 5, Specifications and Selection Criteria for Crane Rails as per Indian Standards; lesson 6, Design of Gantry Girders: Detailed Overview and Calculations. The full course has 48 lessons (21 h 46 min of video); see the course overview or its price and syllabus.

Lesson transcript

Machine transcript of the lesson audio (lightly cleaned). Technical terms may contain errors; the video is the reference.

Hello, welcome back everyone. Now coming to the first session of this course, Design of Sheds with Gantry. In the first part, we covered the column location and column spacing and orientation of columns. Now we will go into the other parts of this session. That is, first we will go to the thumb rules for member sizing. These are the thumb rules for deciding the initial member sizes like size of beams, size of columns, even the size of the roof purlins or the vertical bracings. We can actually decide preliminary sizes of these members based on some thumb rules.

Here this table actually shows the thumb rules for deciding the member sizes, main beam sizes and these are based on the conference held in Los Angeles in year 2000, North American Steel Construction Conference. And this suggested to size the beam sizes, depth of the beam shall be in the range of L over 20 to L over 30 for span range of 0 feet to 75 feet or you can say in meters 0 to 20 meter spans. We can use these thumb rules for starting with the design of, detailed design for earlier beam sizes.

And you can see here in this for different type of systems also there, they have shown steel beam, steel joists also there, floor members. The floor members are like carrying floor loads is like mezzanine floors or any other intermediate floors they have given. This table is not only restricted to the Gantry structure, shed type structures, because of that they have given all these ratios, those number rules for even for other structures, we can follow these things, even joist girders, plate girders, you will come to know about all these terms joist beam, plate girders, beam, joist girders, all those things you will come to know in the further sessions or in a way, if you go and study different type of steel structures, then these joist girders, steel joist, plate girders beams will be, you will come across those things.

In this case, for us, steel beam, roof members and steel truss also is one of the important thing. If you are going with the steel shed with the truss arrangement, the truss, depth of the truss, we need to decide. And it generally, depth of the truss will be span over 10 to span over 12, 13, in that range it will be there. Unless you have very, very light wind, where you can reduce the truss depth, but even we can actually reduce the depth of the truss, if there is any service requirement, but it will not be economical, we need to have a higher beam sizes and it will lead to higher material weights.

The higher truss depth, you will get more economical sizes of the beam, but it should not be very high. Ideally, it will be span over 10, will give you a better truss member sizes. Then coming to the columns, the design of columns will be mainly governed by axial capacity of the columns. And also, especially in case of portal frames, movement will also come into picture. Not only the axial capacity of the column, the movement also will govern. In that case, if the movement is the governing thing, then the column sizes will mostly be based on the size of the beam that is being connected to the column.

Otherwise, if it is a truss type thing and the columns are resisting mainly the axial loads, then in that case, these are the basic thumb rules we can follow to arrive at the minimum initial column sizes. And these are actually based on the area of the section, not on the depth of the section or width of the section. Actually, again, these thumb rules are arrived from the same conference. And since it is a US, they have given in both the units. It's like SI units and KSAS also they have given.

Again, for this 250 MPa, you can use this formula P is approximately area times 22 minus 0.10 KL by R ratio. That is a slenderness ratio. You might be knowing already this what is slenderness ratio. And for higher grade of steel, you require different area because the strength of the steel is very high. So, you can actually read, you can, we will, it will lead to the lesser size of column for the same axial capacities. Here again, in this formulas, P is the actual axial load coming onto the column and A is the area of the section.

So, in this, we need to find the area of the section base after getting the primary axial load coming onto the column. So, we can arrive at the column area of the steel column required and you can actually initially decide the size of the column based on that area. And the same principle that used for beams, we can actually use for purlins also because those are also flexible members to carry the vertical loads only. If purlins generally will be of like ISMC channel sections or even nowadays using coal formed jet purlins also, which are very economical, which will give you the very lesser weight for higher capacities.

Okay. Coming to the next point is slope of roof. Roof slope also depends on many aspects like rainfall intensity of that area because the higher the rainfall intensity, we need to give a higher slopes. If we provide a very flat roof like with a minimum slope, when the high rain comes, then the sheeting will not be able to support the drain water and it will even the drain water gutter system and downs downward spouts will also will not meet the design requirements. So, based on that also, we need to decide what is the minimum slope to be followed.

The other aspect is even in the snow falls areas, generally that is also one more governing thing. And one more aspect in that consideration is the dust filling, especially in the industrial structures like power plants and cement plants. There is a lot of dust formation in the air and it will go and accumulate on the roof. If the roof is very flat, even if the rain water may go very easily downward, but this dust will accumulate if the roof slope is very less and it will lead to the additional load onto the structure.

So, especially in those type of industrial structures like power plants, cement plants, wherever there is a scope of dust formation, even in some cases coal mining areas also. So, there we need to have higher slope roof so that the dust will not accumulate on top of the roof. And one more aspect that governs the roof slope is cladding type also. There are different type of roof sheeting is available. That is a galvanized steel sheeting also there and asbestos sheeting will be there. So, based on this, if it is a steel sheeting, galvanized steel sheeting, nowadays many places they are being used.

We can have a lesser slope, but for the same conditions, if we are using asbestos sheeting, then we need to have a higher slope so that rain water will easily go down. One thing and the other thing is regarding this sand, dust accumulation at the top. These are all the things which governs the roof slope. And then coming to the angle of the roof slope, in general, it will be like 5 degrees to 15 degrees. It will be in the range of that one. For normal shed type structures that we are dealing, right, we are concentrating on, it will be mostly around 5 to 6 degrees.

If you see in terms of horizontal height over horizontal width, it is 1 over 10. That will be mostly ideally we can actually start with that. But in case we can actually go for a little bit more slope if we want some optimization in terms of steel because of that cambering, you will get some more additional advantages. But with the higher slopes, this point is actually, this is the next point is the same thing. This cambering helps in countering the vertical deflections. The higher the camber, you will get less vertical deflection.

I will show this point with you in a start example model. Here you can see, I have modeled for illustration purpose only, 2D frames only actually I have used. And we are analyzing it only for dead and live load. You can see the one frame is with some slope. This is a slope cambered roof. The other one is a flat roof. We will go to the post-processing. You can see the deflections. Difference in deflections. I will, you can see the flatter portion will have higher deflection than the camber one.

That's why if you have one more frame with a higher camber, then the deflection will come down and also the many movements and shear. Process in the members also will come down because of that. If you can see this one also. For this case, no, we don't. Graphs. Okay. You see here, the many moments. You can see actually this is okay in Kip, Sinches is there. You can see the columns. These have 978 moment is there. In this case, it is 1063. Not a lot of difference, but there is some difference is there. For a flat roof, it is will be higher. For a cambered one, the moments will be less. Even if you see the compare the span moments also, this is 444. In this case, it is 332.

So, this significant difference is here with the span moments. So, that's why we can actually even optimize this even rafter also for a cambered one. So, that's why this slope of the roof will help not only in the carrying the to avoid the rainwater accumulation on top of the roof and also sand dust or any industrial dust accumulation, but also it will help in economy also. It will reduce the deflection also. So, that's why in some cases, normally we will go for a roof of the slope as 1 in 10 ratio, but in some cases, if you need to have lesser deflection, if you want to reduce the structural economy, structural weight, we can actually go for a little higher slope also, but it should not be too high.

So, that's why? So, that it will look very awkwardly to the visible eyes. Again, coming back to the deflection part. Here, you can see the actual deflected shapes, deflection values for both the cases. One with the cambered one, one other with the flat roof. The cambered one, we have 97 mm. The flat roof, it has 120. So, that's like 25% difference is there. So, that's why it's always preferred to have a minimum camber. But if you still want to have more economy and want to reduce the deflections for serviceability point of view, you can actually go for a little higher slope also.

And coming to the different roof shapes. This one, if you in the picture shown, it is a monoslope pitched roof and you can see that one. There is only one directional roof is there. This is a monoslope pitched roof as discussed earlier. This one is a dual pitched roof. This is a very, very common type of roof. What we can see in any general 95% of the structures will be of this shape. Even the old houses also are of pitched roof type only. This is one type of roof. This is one type of roof. And then we have multi-pitch, multi-bayer roof systems also will be there. This type of systems, we will come across mostly in warehouses, convention halls also, where multiple conventions will be there in each bay.

These are different types of roof framing arrangements. In this case, actually what I have shown in this picture is there is no crane girder. But this is for illustration purpose only I was showing. This is like multiple base of roof pitched roofs are there. And then we have flat roofs also. These are generally not much used in especially in the shed type structures for the obvious reasons that it will lead to the higher deflections, not economical. And there is also a chance of dust accumulation at the roof level.

But these can be used where the area of the roof is very small span of the main span of the column spacing is very less. Because this will for construction point of view, these are actually very easy. The all the members will be straight. The connections will be a lot easier than the pitched roof type. So simple connections like this is a parking shed type structures. We can go for still, we can go for flat roof type shutters. Now coming to the next point is base plate configuration.

This is one of the most important aspect of the industrial sheds with gantry structures. Base plate, we have different types of base plate configurations. That is one pinned connections, fixed connection and fixed butt connections. These are the three types of connections generally will be adopted for the column base plate anchoring to the foundation pedestal. What is pinned connection? Pinned connection is a free to rotate. It will not transfer any moments to the base. So pinned base is means that only. It will not transfer any moment from the column to the base.

To the base of the pedestal or to the top of the pedestal or to the top of the pedestal. In this we have shown couple of typical base plate, pinned base plate connection plans. So it's a two bolt pinned base one. So four bolt pinned base one. And this is a from a typical actually drawing how it looks like. It's not even you can see the details of the dia of the anchor bolt, thickness of the plate. There will be some stiffness to connect to the bracing.

Bracing members or to decrease the size of the base plate. We will provide some stiffness also if required. You can see observe the stiffener shape here. This will have two purposes. These stiffeners. One purpose is to connect the vertical bracing any vertical bracing. There will be some vertical bracing. It will be connected in this direction and the other purpose will be to increase the capacity of the base plate and thereby to reduce the thickness required thickness of the base plate. If you don't have any stiffener here, the plate will bend differently and more movement will occur in the plate. But if we have stiffness, then the base plate will be less. That is why we provide stiffness whenever the length of the base plate from the column is very high.

Then we go for additional stiffness to restrict the thickness of the base plate. And one more option is this two bolt type pin is normally not used for industrial columns, shed columns. But these can be used for small staircase support framing arrangement or some internal small post, not for a big means normal like structure type. This type of minimum four bolts will be provided. Even though if the requirement is only two bolts, we still go for four bolts for a normal structure, all the main columns.

And then we have fixed base plate type arrangement. Here the anchor bolts, you can observe it the difference between pinned and fixed. In the pinned base plate, anchor bolts are shown within the flange or within the column section. So, this D is very less. Because of the lesser value of D, this connection will not provide resistance against moment. And even the C value also anyway, this column itself is weak in the minor axis direction. So, it will not transfer any forces to the pedestal. But in the main direction as well, since the bolts are provided inside the flanges within the column depth, the movement resistance provided by these two bolts, liver arm from these two bolts is very, very less.

In practical, we can ignore that one and call this as a pin root connection, pin root base plate connection. While coming to the fixed base, you can see here, bolts are provided at the outer edge of the B and the column flanges. For I section, you can see here, the bolts are provided B and the column. Here, the depth, liver arm between the bolt columns is D. That is higher than the column depth. And this will provide, this will give resistance against moment. And because of that, this base plate will provide resistance against rotation for the column. And because of that, pedestals will be subjected to the moment as well as axial forces.

Even in here also, you can see that one. And one more observation from here is, you can see bolts are in the minor axis direction also. There is a significant liver arm is there. Because of that, movement will be resistant, movement resistance will be generated even in the minor axis direction. But for I section, since the I column itself is very weak, it will not transfer any significant amount of moment in the minor axis direction. But for box type of sections or HSS sections or some star-shaped sections, they are strong in both the axis direction. They will carry the moment in both the direction.

So, because of this lever arms. So, because of this lever arms, the base plate orient, this configuration will lead to the movement transfer to the pedestal in both the axis, about both the axis. You see here, this is a typical star type column base plate detail. In this, because of this lever arm. Both the direction, there is bolt to bolt distances, 450 m in this direction, this 450 m in this direction as well. Because of this lever arm, there will be pull and push in one of the bolts and because of that, this base plate arrangement will act as a fix in both the axis.

The same here also, for box section also, there is a significant amount of distance between these two bolts. But in this case, this central portion, the central two bolts will not act in resisting the moment. about this axis, but it will act in resisting the moment about this axis, but these two bolts will not participate. But all the bolts will participate in carrying the tensile force and shear forces. You can see one more example in this. This is a box type of column. This is a built-up box section where you can see the bolt on all four sides of the section.

But the major bending moment will be in the, this is again is a rectangular type box section. Box section is very strong about this axis. Hence, there are higher number of bolts in this direction and this bolt to bolt distance is very high. This will provide a lot of fixity to the column in this direction and some fixity will be there in this direction also because there are three plus threes. So, three bolts on one side and three bolts on another side. It will provide some fixity even in the other direction also.

So, these are the typical examples where base plates are fixed in both the directions. And then we have fixed but base plates also wherein the base plate configuration is in such a way that it will resist the moment about one major axis, but it will not resist the moment about minor axis. These are the few examples you can see. These are only two bolts are there, but this practically, it is only for illustration purpose. I am saying this practically we don't use this type of anchoring arrangement.

Minimum four bolts we use. Again, if you see here also, this lever on me from outer to outer of bolts is very high. So, it will provide some fixity. You can see the typical elevation sections also. Same here. We have three bolts. These are the different type of base plate configurations. I will show one third example also to explain you more detail so that you can appreciate the worth of defenses it will make. Again, coming to the old stratifil that I showed you earlier. This is the same industrial warehouse shed wherein we have different type of columns, base plate fixity type.

You can see here, these all the main columns are fixed but type. In the sense that they are fixed in one direction and pinned in another direction. These are fixed in a major axis direction and pinned in minor axis direction. And then we have few more columns like in the Gabelian columns which are pinned here. You can see that one, right? If you say that these are pinned type base plates. The first one, we have three types of columns, three types of base plate configuration, fixed pin and fixed butt.

In this structure, there is no base plate which is fixed in both the direction. Only two types are there in this structure. I will select one Gabelian frame. You can see here and I will show you 3D model also. You can see here. This is fixed about the major axis of the column. Same in the main column. These two columns are pinned. So, if you can see the bending moment diagrams also, I am showing you, since this is a earthquake load case in X direction, there are no movements in this column.

You can see the, since there is fixity is there, there are bending moments in the column at the base. Yes, there are no movements in the M-Y direction. Okay, when you go to the N-Z direction, instead of that, I will select primary wind load case. Yes, there will be some movement. If you select this, you see, not M-Y, since the orientation of the column is like this. You can see here. Yes, this is for wind loads. On this Gabelian columns, wind direction will be different. On this main columns, wind direction will be different.

Because of this closed building, the wind application is like this. You can see, this orientation is different. That is why it is bending in the other direction. Since this joint is a pinned one, there is no movement whatsoever here. And here also, at the top, they have released it. Even in the F-X, this axial, vertical axial direction also, they are released. So that, top raft loads from the raft will not be transferred to the Gabelian columns. So, this column actually will act as a beam. Basically, vertical beam resisting the horizontal loads only.

There will not be any axial loads, any significant axial loads. You can see here, there are no, not a big deal. If you see here, this is okay. Vertical means only this is a wind loads. So, the loads are less. That's what the basic arrangement of column orientation and basic base plate configuration result into this one. I will go to again modeling. So, what will happen if I change this to base pinner type connection? What will happen is, it will deflect more. And then, since it is a crane type structure, it will lead to higher deflection.

And the deflections will be out of allowable limits. That's why, they have kept a movement base at the main columns, at the base, in the major axis direction. Hopefully, you will understand this, the importance of base plate configuration. Actual importance of base plate configuration in terms of structural behavior itself. And how it will affect the transfer of loads from the roof and from the crane girder to the foundation. If you provide pinner base completely, then only the vertical and the horizontal loads only will come onto the pedestal.

If you provide a fixed base, in addition to the vertical loads and horizontal loads, even movement also will be transferred to the pedestal. But what is the difference between these two is, if you provide a fixed base in the main portal frame direction, it will reduce the deflection of the lateral deflection, horizontal deflection, which will help in limiting the allowable deflection for crane girders. As far as possible, for all the gantry structures, sheds with gantry structure, this is the way we need to go ahead. Unless the height of the structure is very less and lateral loads are very, very less, in that case, we can actually even afford with a pinner base column also.

But for all the crane sheds, it is generally preferable to have a fixed base at the main column basis. And for sheds without any gantry, the deflection is not a big issue because allowable deflections, we can go up to height over 150. So, that is not a stringent, that is a very good amount of deflection they are allowing it, as per the coda provisions also. In that case, we can actually provide a pinner base and provide a tapered column also. We can provide with a lesser size column at the base and higher size column at the top.

So, I will show you these type of structures in the later sessions that you will appreciate the importance of this base plate configuration again. Next, we will go to the bracing pattern next. Next, before going to the bracing pattern, I want to show you a few other base plate details. How actual drawing in the actual structures, how it look like base plate configurations. This is an again fixed, but base plate type typical drawing. This is for a huge, huge columns actually. It's not for a small shed.

This is for a thermal power plant, powerhouse building column base plate I am showing here. That's why these columns are very high size. Even the bolts are also very high. For reducing the column means base plate thickness, they have provided multiple stiffness. These multiple stiffnesses. You don't generally need to have it. And then these are the typical anchor bolt details. That also you need to understand this how anchor bolts are provided into the concrete. These are all generally for all these type of structures. It will be cast in situ anchor bolts. Cast in situ means this anchor bolts need to be installed during concrete pouring of the pedestals itself. There will be concrete anchors also will be there.

But they will be generally used for very smaller load. They will not have any risk. They will not have the capacity of those bolts will be very, very small. So they will not use for entire main buildings columns, maybe for staircases, for other small sheds, parking sheds. Even those are also very small sheds. We can use post anchors. But these are the cast in situ anchor. And you can see the typical detail of anchor bolt into the concrete. And you can see different standard details of anchor bolt. The projection of anchor bolt beyond the concrete embedment length.

And there is a pipe sleeve also is provided. This is a general standard practice industrial sheds. Some locations, they avoid this. This is actually provided to have a allowance for moving the base plate while installing, while erecting the column. Okay. Since the concreting, while doing the concreting, they might slightly shift the anchor bolts. They may not position the anchor bolt into the concrete framework correctly. So this pipe sleeve will help in adjusting the anchor bolt slightly. It will not move like maybe 10 amount, 15 amount difference is there. Then we can actually take advantage of this pipe sleeve so that the base plate will fit into this anchor bolts directly.

These are typical schedule of the anchor bolts. I am just going through this so that you will get an idea how the typical industry standard drawings will look like. More on this you will get to know in the later sessions while doing the actual designs of any shed that is a project we are going to assign you to you. This one more point I would like to discuss is that the base plate is shear key. This shear key is actually provided when there is a huge horizontal force being transferred from the column to the pedestal in addition to the tension and moment.

So if there is a huge moment and that leads to higher number of bolts. In addition to the moment or tension, if you have very huge horizontal load, that also has to be resisted by anchor bolts, then number of anchors will increase very much. And to accommodate the number of anchor bolts, we need to have higher base plate size also. To reduce these things, we provide a shear key. This concept actually is similar to the shear key we provide for a retaining wall. RC retaining walls also, this concept is there.

Again, you will come to know more about this in the further sessions. So just I am briefing you how it look like, what are the different base plate types and those things. So as of now, in this part of the session, we covered thumb rules for member sizing. So what are the thumb rules based on which we can actually initiate the member sizes before going to the detail design. And then we gone through the different type of roof slopes and the advantages of having a cambering roof slope. And then we saw different base plate configurations.

And we also saw a lot of industrial practice, industrial standard, shear key, industrial standard base plate configuration drawings, actual sketches also have shown. And the standard model also what is the difference between pinnard and fixed moment. So all these things we have covered in this part of the session. In the next part, that is third part of this session, we will discuss the next three points that is bracing pattern and crane supporting arrangement, crane vendor drawing studies, and then summary part of this session. I hope you understand all these things like three parts, term rules for member sizing, roof slopes, base plate configuration, basic pattern.

Okay, thank you. We will cover the next three points in the next part of this session. Thank you. Thank you. Thank you.

Want the rest of Design of Sheds with Gantry?

Get the full course syllabus and fees.

The full course is paid (₹40,000). We'll send the syllabus and call you back within one working day.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Full course · paid

Unlock the full Design of Sheds with Gantry course

The remaining 45 lessons, mentor-reviewed projects and a certificate come with the paid course (₹40,000). Leave your details: we'll send the syllabus and fees and call you back.

Get the syllabus and fees

A counsellor calls you back within one working day.

By submitting you agree to our Terms and Privacy Policy.

Grow by Skill-Lync · free lesson

Start watching

Free, no payment. Leave your details once and every free lesson on Grow plays straight away. A Skill-Lync counsellor may call you about the full Design of Sheds with Gantry course.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.