Hydraulics and Pneumatics cover
Interactive book · Semester 4-7

Hydraulics and Pneumatics

Size the pumps, cylinders and valves of a 400 kN press, run it through a cycle, then build a pneumatic sequence and find the fault in a circuit

24 chapters, 24 interactives, few words. This book covers the hydraulics and pneumatics (fluid power) course of mechanical engineering: Pascal's law, hydraulic oils, lines and filters, gear, vane and piston pumps, pump control, cylinders, cushioning, hydraulic motors and hydrostatic drives, direction, pressure and flow control valves, servo and proportional valves, regenerative, speed control, accumulator and press circuits, compressed air, pneumatic actuators, the cascade method, electro-pneumatics and troubleshooting. One oil, one 400 kN press and one pneumatic fixture run through the whole book, so the numbers in one chapter carry into the next.

  • AUME3492Hydraulics and Pneumatics
  • VTUBME702Hydraulics and Pneumatics
  • SPPU302054Fluid Power and Control Laboratory
  • MUMESBL601Measurements and Automation (Group C: automation)
  • KTUMET424Industrial Hydraulics

By Skill-Lync · Updated 24 Nov 2026 · 24 chapters · 24 interactives · free, no sign-up

Chapter 1

Fluid power systems: hydraulics, pneumatics and Pascal's law

Which syllabus covers thisAU ME3492 Unit I (fluid power, advantages, Pascal's law, work, power and torque)VTU BME702 Module 1 (fluid power system, Pascal's law)SPPU 302054 Practical 1 (fluid power fundamentals)MU not in syllabusKTU MET424 Module 1 (classification, basic components)

What is a fluid power system, and what are its parts?

Fluid power moves and pushes things with a liquid (hydraulics) or air (pneumatics) under pressure. THE PRESS in this book has every part. A prime mover, a 1,450 rpm electric motor, turns two pumps of 8 and 32 cm³/rev that deliver 53.36 L/min of oil. Valves decide where the oil goes, how hard it may push (a relief valve set at 210 bar) and how fast. The actuator, a 160 mm bore cylinder, turns pressure into force. A tank stores and cools the oil, and lines carry it between them.

What does Pascal's law say, and what does a hydraulic jack trade for its force?

Pressure applied to a trapped liquid acts equally everywhere in it. Push a 16 mm plunger and the same pressure acts on a 63 mm ram, so the force grows by the area ratio, 15.5 times, and a 10:1 lever adds another 10. A 322 N hand force lifts 50 kN at 160 bar. Nothing is free: the oil pushed out by one 25 mm plunger stroke lifts the ram only 1.61 mm, so 100 mm of lift takes 63 strokes. Work in equals work out, 80.6 J per stroke.

Pascal's law at work: a hydraulic jack and a press multiply force, and what they trade for it in stroke, flow and power: interactive loads as you scroll

How are force, speed, power and torque linked in a hydraulic system?

Pressure times area gives force; flow divided by area gives speed; pressure times flow gives power. THE PRESS makes 400 kN at 198.94 bar on its 160 mm cylinder. The small pump's 10.672 L/min moves it at 8.85 mm/s, so the power is 3.54 kW, the same as 400 kN × 8.85 mm/s. The pump shaft needs a torque of Vg Δp/(2π ηm) = 28.1 N·m. Both pumps at full pressure would need 17.7 kW of hydraulic power, which is why the press presses on the small pump only.

What are the advantages and limits of hydraulics against pneumatics and electric drives?

Hydraulics gives the most force for its size: the same 63 mm bore makes 1.87 kN on 6 bar shop air but 65.5 kN at 210 bar. Oil is stiff: its bulk modulus of about 1.5 GPa is 2,139 times air's 0.7 MPa at 6 bar, so a hydraulic cylinder holds position and air springs. A relief valve makes overload safe. The price is leaks, fire risk, filtration and heat: THE PRESS turns 4.77 kW into heat during every dwell. Pneumatics is fast, clean and cheap for light forces; electric screws are precise and efficient but need a limit against overload.

Where does a fresh engineer meet fluid power in Indian industry?

In sheet-metal and forging presses, plastic injection moulding machines and machine tool clamping and feeds on the shop floor. On construction sites in excavators, backhoe loaders and cranes, whose arms are hydraulic cylinders. On farms in the tractor's three-point hitch that lifts a plough. In steel plants in rolling mill gap control, and in every assembly line's pneumatic clamps, grippers and presses. The same five parts (prime mover, pump or compressor, valves, actuator, conditioning) appear in all of them, whether on 6 bar shop air or on oil at 210 bar like THE PRESS.

Predict, then check

A jack's ram bore is doubled from 63 to 126 mm; the plunger, lever and hand force stay the same. What happens?

Worked examples

A hand jack: load, pressure and strokes · Plunger bore 20 mm, ram bore 80 mm, lever ratio 8, hand force 250 N, plunger stroke 25 mm, lift 120 mm (assumed jack).
  1. Plunger force F1 = 250 × 8 = 2,000 N.
  2. Plunger area A1 = π × 0.020²/4 = 314.2 mm²; oil pressure p = 2,000/314.2 mm² = 63.66 bar.
  3. Ram area A2 = π × 0.080²/4 = 5,027 mm²; load W = p × A2 = 32 kN (area ratio 16).
  4. Ram rise per stroke = 25 × A1/A2 = 25/16 = 1.5625 mm.
  5. Strokes for 120 mm = 120/1.5625 = 76.8, so 77 strokes.
  6. Check: work in per stroke = 250 N × 8 × 25 mm = 50 J = 32 kN × 1.5625 mm.

Answer: Load 32 kN at 63.7 bar; 1.563 mm per stroke; 77 strokes for 120 mm.

THE PRESS: pressure, speeds and power · Cylinder 160 mm bore, 100 mm rod; pumps 8 and 32 cm³/rev at 1,450 rpm, volumetric efficiency 0.92; full force 400 kN.
  1. Cap area A1 = π × 0.16²/4 = 0.020106 m²; pressure for 400 kN = 400,000/0.020106 = 198.94 bar.
  2. Small pump flow = 8 × 1,450 × 0.92/1,000 = 10.672 L/min; both pumps 53.36 L/min.
  3. Rapid approach = (53.36/60,000)/0.020106 = 44.23 mm/s; 330 mm takes 7.46 s.
  4. Pressing on the small pump = 8.85 mm/s; power at full force = 198.94 × 10⁵ × 10.672/60,000 = 3.54 kW.
  5. Return on the annulus A2 = 0.012252 m²: 72.59 mm/s (faster: smaller area).

Answer: 198.9 bar; 44.2 mm/s approach, 8.85 mm/s pressing at 3.54 kW, 72.6 mm/s return.

Torque and heat while THE PRESS dwells · During the 2 s dwell the small pump (8 cm³/rev) blows over the relief at 210 bar and the big pump (32 cm³/rev) is unloaded at 3 bar; mechanical efficiency 0.9, 1,450 rpm.
  1. Small pump torque T = Vg Δp/(2π ηm) = 8 × 10⁻⁶ × 210 × 10⁵/(2π × 0.9) = 29.71 N·m.
  2. Big pump torque at 3 bar = 1.698 N·m.
  3. Shaft power = T × ω, ω = 2π × 1,450/60 = 151.84 rad/s: 4.511 + 0.258 = 4.769 kW.
  4. Hydraulic power over the relief = 210 × 10⁵ × 10.672/60,000 = 3.735 kW; the cylinder does no work.
  5. So all 4.77 kW becomes heat: 9.54 kJ every dwell.

Answer: 29.7 N·m on the small pump; 4.77 kW in, all of it heat (9.5 kJ per cycle).

Chapter 2

Hydraulic fluids: viscosity, viscosity index, bulk modulus and choosing an ISO VG grade

Which syllabus covers thisAU ME3492 Unit I (types of fluids, properties and selection)VTU BME702 Module 1 (fluids: types, properties, selection, temperature and pressure)SPPU not in syllabusMU not in syllabusKTU MET424 Module 1 (properties of fluids, hydraulic fluids)

What does a hydraulic fluid do, and which types are used?

It carries the power, lubricates the pump and valve surfaces, seals the tiny clearances, and carries heat and dirt to the tank. Most machines run on mineral oil with anti-wear, anti-oxidant and anti-foam additives (HLP or HM type). THE OIL is BPCL MAK Hydrol HLP 46: flash point 244 °C, pour point −21 °C. Where fire is a risk, as near a furnace, plants use fire-resistant fluids: water-glycol (40-50 % water, Atos) or phosphate esters, which need FKM or PTFE seals. Biodegradable ester oils serve forestry and farm machines near soil and water.

What is viscosity, and what does ISO VG 46 mean?

Viscosity is a fluid's resistance to flow. Hydraulic oils are sold by kinematic viscosity in mm²/s (centistokes, cSt) at 40 °C: ISO VG 46 means 46 mm²/s ± 10 %, so 41.4 to 50.6. THE OIL measures 46.1. Viscosity falls fast with temperature: 128.6 mm²/s at a 20 °C cold start, 30.5 at the 50 °C this book runs at. On the ASTM D341 chart, log log(ν + 0.7) against log T, each oil is a straight line through its 40 °C and 100 °C points.

Oil viscosity against temperature for three ISO VG grades, the pump's viscosity window, and how entrained air softens the oil: interactive loads as you scroll

What does the viscosity index tell you?

The viscosity index (VI) measures how little an oil thins as it warms: the higher, the flatter its line. VI is defined against two reference oils, so a VI of 100 means the same thing for every grade. THE OIL, a Group II base oil, has VI 115; Shell's Tellus S2 M HM oils have 97 to 99. Even at VI 115, THE OIL thins 6.1 times between 20 and 60 °C. Multigrade or high-VI oils (HVLP) keep viscosity steadier for mobile machines that start cold and run hot.

What is bulk modulus, and why does entrained air matter?

Bulk modulus β is the pressure needed per unit fractional squeeze of volume. Mineral oil compresses 0.4 to 0.5 % per 1,000 psi, so β is 1.38 to 1.72 GPa; this book uses 1.5. THE PRESS's cap side at mid stroke holds 4.02 L: squeezing it to 200 bar takes 53.6 cm³ extra oil, 0.3 s of small-pump flow. The oil column's stiffness, β A/L, is 150.8 kN/mm. Free air bubbles soften it: with 2 % air at 10 bar only 32.8 kN/mm is left, so bleed air out at commissioning.

How do you choose a grade for a press in an Indian summer shop?

Start from the pump maker's viscosity window, not the weather. A Rexroth AZPF gear pump wants 20 to 100 mm²/s: VG 46 stays inside from 24 to 62 °C. An A10VSO piston pump wants 16 to 36: VG 46 fits from 45.8 to 68.7 °C, VG 68 from 55 to 79.3 °C. With 40-45 °C shop air the oil runs near 50 °C or hotter, so VG 46 suits THE PRESS; a hot-running piston-pump unit might take VG 68. Cold start is no worry on the plains: VG 46 reaches the piston pump's 1,600 mm²/s limit only at −12.5 °C.

Predict, then check

THE OIL (VG 46) warms from a 20 °C cold start to 50 °C. Its viscosity falls by about how much?

Worked examples

Walther constants and the viscosity at 50 °C · THE OIL: ν40 = 46.1 mm²/s, ν100 = 7.17 mm²/s (BPCL data sheet). ASTM D341: log log(ν + 0.7) = A − B log T, T in K.
  1. Z40 = log log(46.8) = 0.22278; Z100 = log log(7.87) = −0.0477.
  2. B = (Z40 − Z100)/(log 373.15 − log 313.15) = 3.5529.
  3. A = Z40 + B log 313.15 = 9.0899.
  4. At 50 °C: Z = A − B log 323.15 = 0.17428; ν = 10^(10^Z) − 0.7 = 30.47 mm²/s.

Answer: A = 9.09, B = 3.553; ν at 50 °C = 30.5 mm²/s.

Temperature band for VG 68 on a piston pump · VG 68: ν40 = 68.3, ν100 = 9.39 mm²/s. Rexroth A10VSO optimum band 16-36 mm²/s.
  1. Walther constants for VG 68: A = 8.8817, B = 3.4527.
  2. Invert: T = 10^((A − log log(ν + 0.7))/B) − 273.15.
  3. ν = 36 mm²/s at T = 55 °C (the cold end of the band).
  4. ν = 16 mm²/s at T = 79.3 °C (the hot end).
  5. At this book's 50 °C, VG 68 is 43.9 mm²/s: a little too thick for the optimum, still permitted (10-400).

Answer: Optimum from 55 to 79.3 °C.

Oil compression and stiffness in THE PRESS · Cap side at mid stroke: 160 mm bore, 200 mm oil column. β = 1.5 GPa; entrained air 1 % at 100 bar gives β = 1.443 GPa (mixture rule).
  1. Oil volume V = 0.020106 × 0.2 = 4.021 L.
  2. Extra oil to reach 200 bar: ΔV = V p/β = 4.021 × 200 × 10⁵/1.5 × 10⁹ = 53.6 cm³.
  3. At 10.672 L/min (177.9 cm³/s) that takes 0.3 s.
  4. Stiffness k = β A²/V = β A/L = 1.5 × 10⁹ × 0.020106/0.2 = 150.8 kN/mm.
  5. With 1 % air: k = 1.443 × 10⁹ × 0.020106/0.2 = 145 kN/mm.

Answer: 53.6 cm³ to pressurise (0.3 s); stiffness 150.8 kN/mm, 145 kN/mm with 1 % air.

Chapter 3

Flow in pipes and hoses: Reynolds number, friction losses and sizing the lines

Which syllabus covers thisAU ME3492 Unit I (principles of flow, friction loss)VTU BME702 Module 1 (transmission of power at static and dynamic states)SPPU not in syllabusMU not in syllabusKTU MET424 Module 4 (hydraulic conductors)

What is the Reynolds number, and is oil flow in hydraulic lines laminar?

The Reynolds number Re = v D/ν compares inertia with viscous drag. Below about 2,300 flow in a pipe is laminar: smooth layers, a parabolic velocity profile. Above it, flow turns turbulent and mixes. Thick oil keeps many hydraulic lines laminar. THE PRESS's pressure line, 19 mm bore at 53.36 L/min and 50 °C, runs 3.14 m/s at Re 1,956: laminar. At a 20 °C start Re is only 463. In a 16 mm line Re reaches 2,323, right at the transition.

How do you work out the pressure lost in a line and its fittings?

Darcy-Weisbach: Δp = f (L/D) ρv²/2 for the straight pipe, plus K ρv²/2 for each fitting. In laminar flow f = 64/Re, which is the Hagen-Poiseuille law; in turbulent flow f comes from the Colebrook equation. THE PRESS's 19 mm, 3 m pressure line loses 0.212 bar in the pipe and 0.247 bar in four elbows (K 1.5 each, a turbulent-flow value; laminar fitting losses are larger). That is 40.8 W of heat. Cold oil at 20 °C multiplies the pipe loss by 4.31.

How are hydraulic lines sized?

By velocity. This book keeps suction lines to 1 m/s, pressure lines to 5 m/s and return lines to 3 m/s, inside Atos's bands (1-1.5, 4-8, 1.5-4 m/s) on the low side because THE PRESS runs two shifts. Faster flow wastes power and raises pressure spikes. Bore D = √(4Q/πv): for 53.36 L/min the suction line needs 33.7 mm (38 mm hose), the pressure line 15 mm (16 mm). The return line carries the cap side's 87.6 L/min on the rapid return, not the pump flow, so it needs 24.9 mm: a 25 mm hose.

Sizing suction, pressure and return lines: velocity, Reynolds number, friction and fitting losses and the power they waste: interactive loads as you scroll

When do you use steel tube, pipe or hose, and how strong must they be?

Rigid seamless steel tube (E235 to EN 10305-4) with compression fittings runs between fixed parts; welded pipe with flanges suits big bores; hose joins parts that move or vibrate. Two-wire SAE 100R2AT / EN 853 2SN hose is rated 215 bar at 19 mm bore but only 165 bar at 25 mm, with burst at four times the rating. For a 16 mm bore at 210 bar, Barlow's formula with E235's allowable 235/1.5 MPa and 85 % of the wall gives a wall of at least 1.5 mm, so a 20 × 2 mm tube, rated 266 bar by this estimate.

Why is the suction line the biggest line on the power pack?

The pump can only suck with the atmosphere's help: about 1.01 bar absolute, and the AZPF gear pump needs at least 0.7 bar absolute at its inlet. Only 0.31 bar may be spent on the suction line and strainer. A 38 mm, 1 m suction line with cold oil at 20 °C loses 0.023 bar, leaving 0.99 bar absolute. A 19 mm line would lose 0.37 bar and leave 0.65: vapour and air bubbles form and collapse (cavitation), and the pump gets noisy and wears.

Predict, then check

THE PRESS's laminar pressure line runs with cold oil at 20 °C instead of 50 °C. How does the straight-pipe pressure loss change?

Worked examples

Reynolds number and pressure loss in the pressure line · 53.36 L/min through a 19 mm bore, 3 m long, four 90° elbows (K 1.5 each); THE OIL at 50 °C: ν = 30.47 mm²/s, ρ = 835.6 kg/m³.
  1. Area = π × 0.019²/4 = 283.5 mm²; v = (53.36/60,000)/area = 3.137 m/s.
  2. Re = v D/ν = 3.137 × 0.019/30.47 × 10⁻⁶ = 1,956: laminar.
  3. f = 64/Re = 0.0327; ρv²/2 = 4,111 Pa.
  4. Pipe: Δp = 0.0327 × (3/0.019) × 4,111 = 0.212 bar.
  5. Elbows: 4 × 1.5 × 4,111 = 0.247 bar. Total 0.459 bar.
  6. Power lost = Δp × Q = 45,903 Pa × 0.8893 × 10⁻³ m³/s = 40.8 W.

Answer: v 3.14 m/s, Re 1,956 (laminar), Δp 0.46 bar, 41 W lost.

Sizing THE PRESS's three lines and the pressure-line wall · Pump flow 53.36 L/min; cap-side discharge on the rapid return 53.36 × φ (φ = 1.641); limits 1 / 5 / 3 m/s; hose bores 6.3 … 51 mm; E235 tube allowable 235/1.5 MPa, 85 % of the wall counted, relief 210 bar.
  1. Suction: D ≥ √(4 × 0.000889/(π × 1)) = 33.7 mm → 38 mm hose, v = 0.78 m/s.
  2. Pressure: D ≥ 15 mm → 16 mm, v = 4.42 m/s.
  3. Return: Q = 53.36 × 1.641 = 87.57 L/min; D ≥ 24.9 mm → 25 mm, v = 2.97 m/s.
  4. Pressure-line wall: p(D + 2t) = 2 σ c t → t = 21 × 16/(2 × (156.7 × 0.85 − 21)) = 1.5 mm.
  5. Choose 20 × 2 mm tube: rating 2 × 156.7 × 0.85 × 2/20 = 26.6 MPa = 266 bar ≥ 210 bar.

Answer: Suction 38 mm, pressure 16 mm (20 × 2 mm tube), return 25 mm sized for 87.6 L/min.

Will the pump cavitate? Two suction lines at a cold start · 53.36 L/min, 1 m line with one elbow, THE OIL at 20 °C (ν 128.6 mm²/s, ρ 853.1 kg/m³); pump at oil level; AZPF needs ≥ 0.7 bar abs.
  1. 38 mm: v = 0.784 m/s, Re = 232; Δp = 0.023 bar → inlet 1.013 − 0.023 = 0.99 bar abs.
  2. 19 mm: v = 3.137 m/s, Re = 463, f = 64/Re = 0.1381.
  3. 19 mm pipe loss = 0.305 bar, elbow 0.063 bar, total 0.368 bar.
  4. Inlet = 1.013 − 0.368 = 0.645 bar abs, below 0.7.

Answer: 38 mm: 0.99 bar abs, safe. 19 mm: 0.65 bar abs, the pump cavitates.

Chapter 4

Contamination control: filters, beta ratio, ISO 4406 cleanliness codes, reservoirs and seals

Which syllabus covers thisAU ME3492 Unit II (reservoirs, filters), Unit V (conditioning of hydraulic fluids)VTU BME702 Module 1 (seals, filters, strainers, contamination control)SPPU not in syllabusMU not in syllabusKTU MET424 Module 1 (reservoirs, seals, filters and strainers)

Where does dirt in a hydraulic system come from?

Four places. Built-in dirt: machining chips, weld scale and paint flakes left from manufacture, which is why Atos asks for pipes to be pickled and flushed. New oil: DIN 51524 only promises 21/19/16, dirtier than most machines accept, so fill through a filter cart. Ingress: dust through the tank breather and past the cylinder rod seal. Generated dirt: wear particles from pumps and valves, which grind out more particles. Water and air are contaminants too.

What is a filter's beta ratio, and how much does a better filter help?

β_x is the number of particles of size x and larger before the filter divided by the number after (ISO 16889 test). Efficiency = 1 − 1/β: β 2 stops 50 %, β 20 95 %, β 75 98.7 %, β 200 99.5 %, β 1000 99.9 %. In this book's well-mixed model the count settles at N = R/(Q(1 − 1/β)). On a shop floor THE PRESS settles at 93.7 particles per ml with β 2 and 47.1 with β 200, but β 1000 improves on β 200 by only 0.4 %. Past β 75, keep dirt out instead.

How do you read an ISO 4406 cleanliness code like 18/16/13?

Three scale numbers for particles per ml of oil at least 4, 6 and 14 µm(c) in size. Each step doubles the count: 18 means 1,300 to 2,500 particles, 16 means 320 to 640, 13 means 40 to 80. HYDAC's targets for systems above 200 bar are 18/16/13 for gear pumps, directional valves and cylinders, and 16/14/11 for proportional valves, with the system kept one class better than its most sensitive part. Rexroth data sheets allow up to 20/18/15: a maximum the part survives, not a target for long life.

Contamination: particle counts to an ISO 4406 code, filter beta ratio and the cleanliness a system settles at: interactive loads as you scroll

Where are filters placed in a circuit?

A suction strainer guards the pump only against big debris: a fine filter there would starve it. A pressure filter after the pump protects sensitive valves and must take full pressure. A return filter cleans everything coming back at low pressure; size it for the biggest return flow, 87.6 L/min on THE PRESS's rapid return, not the pump's 53.36. An off-line (kidney-loop) filter with its own pump runs all the time. At a dusty site, adding 50 L/min of it only takes the count from 188 to 97 per ml: seal the breather and rod first.

How big should the tank be, and can it get rid of the heat?

The rule of thumb is 3 to 5 times the pump flow per minute plus a 10 % air cushion (Power & Motion; Atos says 2 to 4). At 3 times, THE PRESS's tank holds 160 L, and the oil rests there 3 minutes so air and dirt settle; a baffle keeps the return away from the suction. Everything but the work on the workpiece ends as heat: THE PRESS puts 2,526 W into its oil on average. A 160 L tank on legs sheds only 237 W with oil at 50 °C in 40 °C shop air (assumed 12 W/m²K), so it needs a cooler of about 2.29 kW, or 21 m² of tank wall.

How are seal materials chosen?

By fluid, temperature and motion. Nitrile rubber (NBR) suits mineral oil from −30 to +80 °C (Rexroth AZPF data); fluoroelastomer (FKM, Viton) takes −20 to +110 °C and is needed with phosphate-ester fluids, where Atos also allows PTFE. Polyurethane (PU) is tough and wear-resistant for rod and piston seals. A rod wiper scrapes dirt off the rod before it gets in. Keeping oil below 60 °C, as Atos advises, spares the seals: hot oil hardens rubber and a leaking seal lets dirt in.

Predict, then check

On the shop floor THE PRESS's return filter goes from β 200 to β 1000 (same ingress and flow). How much lower is the steady particle count?

Worked examples

Reading two oil samples against the target 18/16/13 · Sample A: 2,100, 560 and 70 particles per ml ≥ 4, 6 and 14 µm(c). Sample B: 5,200, 700 and 90. ISO 4406 ranges per ml: 13 = 40-80, 14 = 80-160, 16 = 320-640, 17 = 640-1,300, 18 = 1,300-2,500, 20 = 5,000-10,000.
  1. A: 2,100 lies in 1,300-2,500 → 18; 560 in 320-640 → 16; 70 in 40-80 → 13. Code 18/16/13.
  2. B: 5,200 lies in 5,000-10,000 → 20; 700 in 640-1,300 → 17; 90 in 80-160 → 14. Code 20/17/14.
  3. Target for THE PRESS (above 200 bar, gear pump and directional valves): 18/16/13.

Answer: A = 18/16/13 meets the target; B = 20/17/14 fails at every size.

Steady count and clean-up time after an oil change · Shop-floor ingress 2.5 × 10⁶ particles ≥ 14 µm per minute (assumed); return filter β 200; flow 53.36 L/min; tank 160 L; new oil starts at 640 per ml.
  1. Efficiency = 1 − 1/200 = 0.995; cleaned flow = 53,360 × 0.995 = 53,093 ml/min.
  2. Steady count N = 2.5 × 10⁶/53,093 = 47.1 per ml → code 13.
  3. Time constant τ = V/(Q e) = 160,080/53,093 = 3.02 min.
  4. To fall from 640 to 80 (top of code 13): t = τ ln((640 − 47.1)/(80 − 47.1)) = 8.7 min.

Answer: Settles at 47.1 per ml; reaches code 13 about 9 minutes after start-up.

Tank size and heat balance · Pump flow 53.36 L/min; tank 3 × flow per minute + 10 % air; box 2:1:1 on legs; k = 12 W/(m²·K) (assumed); oil 50 °C, air 40 °C; press oil heat load = (shaft energy − work on the workpiece)/cycle = (50.39 − 5.397) kJ/17.81 s.
  1. Oil = 3 × 53.36 = 160.1 L; box = 176.1 L = 0.1761 m³.
  2. 2H × H × H = 0.1761 → H = 0.445 m; area = 10 H² = 1.98 m².
  3. Tank sheds 12 × 1.98 × 10 = 237 W.
  4. Heat load = 2,526 W, so the cooler must take 2,289 W.
  5. Without a cooler the tank would need 2,526/(12 × 10) = 21.05 m² of wall, over ten times this tank's.

Answer: 160 L tank sheds 237 W of 2,526 W: fit a cooler of about 2.29 kW.

Chapter 5

Pumping theory: displacement, volumetric and mechanical efficiency, torque and power

Which syllabus covers thisAU ME3492 Unit I (pumping theory, classification, problems)VTU BME702 Module 2 (pumping theory, performance, problems on pumps)SPPU 302054 Practical 3 (pump trial)MU not in syllabusKTU MET424 Module 2 (pumping theory, pump performance)

Why does every hydraulic system use a positive-displacement pump and not a centrifugal one?

A positive-displacement pump traps a fixed volume of oil each turn and pushes it out, whatever the pressure. THE PRESS's small pump displaces 8 cm³ a turn: at 1,450 rpm that is 11.6 L/min at 20 bar or at 200 bar, less only a small leakage. A centrifugal pump's flow collapses as the head rises (the Turbomachinery book compares the two curves). Hydraulic machines need high pressure at low flow: Rexroth's AZPF gear pumps run continuously at 250 bar and the A10VSO piston pump at 280 bar. The flip side: a positive-displacement pump must never be blocked, so every circuit has a relief valve.

How does a pump draw oil in and push it out, and who decides the pressure?

Chambers open at the inlet and close at the outlet. As a chamber grows, its pressure falls and the atmosphere pushes oil in from the tank, so the inlet must stay above about 0.7 bar absolute (AZPF datasheet). As the chamber shrinks the oil has nowhere to go but out. The pump makes flow; the load makes pressure. THE PRESS's pumps see 20 bar while the platen falls freely and 198.9 bar at full force. The same pump, the same flow: only the resistance changed.

What are volumetric, mechanical and overall efficiency, and what changes them?

Volumetric efficiency ηv is actual flow over Vg × n: oil slips back through clearances, and that slip grows with pressure and falls with viscosity. Mechanical efficiency ηm is the ideal torque Vg Δp/2π over the torque you actually supply; friction and oil drag eat the rest. Overall ηo = ηv × ηm. THE PRESS's 8 cm³ gear pump at 200 bar and 50 °C: ηv 0.92, ηm 0.90, 10.67 L/min, 28.3 N·m, 4.3 kW in. In this model, oil at 70 °C drops ηv to 0.84; cold oil at 20 °C drops ηm to 0.81. Bosch Rexroth quotes typical overall values of 85 % for gear and vane pumps and 91 % for axial piston pumps.

A positive-displacement pump: flow, leakage, torque, input power and efficiency against pressure, speed and oil temperature: interactive loads as you scroll

How do you get a pump's input power and choose its electric motor?

Hydraulic power in kW is pressure in bar times flow in L/min divided by 600. Shaft power is that divided by ηo, or torque times speed. THE PRESS's small pump gives 3.56 kW of oil power at 200 bar and needs 4.3 kW at the shaft. Pick the next IEC rated output above the worst case: the press's worst moment is the dwell, 4.77 kW for both pumps, so a 5.5 kW motor. Its IE3 minimum efficiency at 4 poles is 89.6 % (IEC 60034-30-1), so the supply sees 5.32 kW.

What are cavitation and aeration at a pump inlet, and how do you prevent them?

If inlet pressure falls too low, dissolved air comes out and oil vapour forms bubbles; they collapse violently as the chamber pressure rises, pitting metal and making a gravelly noise. That is cavitation. Air sucked in at a loose fitting or a low tank level is aeration: the oil turns spongy and noisy. Keep the suction line short and fat: both press pumps (53.36 L/min) at 1 m/s need a 33.7 mm bore. Start on warm oil: VG 46 is 128.6 mm²/s at 20 °C, inside the AZPF's 2,000 mm²/s cold-start limit but far above its 20-100 optimum.

Predict, then check

THE PRESS's 8 cm³ gear pump gives 10.67 L/min at 200 bar with oil at 50 °C. The oil warms to 70 °C. In this chapter's model, the pump now delivers about:

Worked examples

Pump test: find the three efficiencies · A gear pump of 12 cm³/rev runs at 1,450 rpm. On the test stand it delivers 16.2 L/min at 160 bar, and the torque meter reads 34.5 N·m.
  1. Theoretical flow Qth = 12 × 1,450/1,000 = 17.4 L/min; ηv = 16.2/17.4 = 0.931.
  2. Ideal torque = Vg Δp/2π = 12 × 10⁻⁶ × 160 × 10⁵/2π = 30.56 N·m; ηm = 30.56/34.5 = 0.886.
  3. Input power = T ω = 34.5 × 2π × 1,450/60 = 5.239 kW; output = 16.2 × 160/600 = 4.32 kW.
  4. ηo = 4.32/5.239 = 0.825 = ηv × ηm. The other 0.92 kW heats the oil.

Answer: ηv = 0.931, ηm = 0.886, ηo = 0.825; 5.24 kW in.

Size a vane pump and its motor · A power pack needs 25 L/min at 140 bar. Motor 1,440 rpm (assumed). Vane pump ηv 0.92, ηo 0.85 (this book's vane values).
  1. Displacement needed = 25 × 1,000/(1,440 × 0.92) = 18.87 cm³/rev; take the next catalogue size, 20 cm³ (a PV7 size).
  2. Actual flow = 20 × 1,440/1,000 × 0.92 = 26.5 L/min.
  3. ηm = 0.85/0.92 = 0.924; torque = 20 × 10⁻⁶ × 140 × 10⁵/(2π × 0.924) = 48.2 N·m.
  4. Shaft power = 48.2 × 2π × 1,440/60 = 7.27 kW (check: 26.5 × 140/600/0.85 = 7.27 kW).

Answer: 20 cm³/rev pump, 26.5 L/min, 48 N·m, 7.27 kW: a 7.5 kW motor.

Hot oil and the press's pressing speed · THE PRESS's 8 cm³ gear pump at 200 bar, 1,450 rpm; leakage 0.928 L/min at 50 °C (ηv 0.92). Leakage scales with 1/µ. Oil warms to 70 °C. Cap-end area 0.020106 m².
  1. µ at 50 °C = 30.5 mm²/s × 835.6 kg/m³ = 25.46 mPa·s; at 70 °C = 15.4 × 824.4 = 12.69 mPa·s.
  2. Leakage at 70 °C = 0.928 × 25.46/12.69 = 1.86 L/min.
  3. Delivered = 11.6 − 1.86 = 9.74 L/min; ηv = 0.84.
  4. Pressing speed = 9.74/60,000/0.020106 = 8.07 mm/s instead of 8.85 mm/s.

Answer: ηv falls to 0.84; the pressing stroke slows by 8.7 %.

Chapter 6

Gear, lobe and vane pumps: displacement from geometry, balanced and variable-displacement vane pumps

Which syllabus covers thisAU ME3492 Unit I (pump construction, working and design)VTU BME702 Module 2 (gear pumps, vane pumps)SPPU 302054 Practical 3 (gear and vane pumps)MU not in syllabusKTU MET424 Module 2 (vane pump, gear pumps)

How does an external gear pump work, and how big is its displacement?

Two meshing gears turn in a close-fitting housing. Oil is carried round the outside in the tooth spaces from inlet to outlet; the mesh in the middle stops it coming back. Summing the pressure torques on both gears gives the exact displacement below (relief grooves symmetric). Module 2 mm, 12 teeth, 26 mm wide: 8.02 cm³/rev, about THE PRESS's small pump, and 11.6 L/min at 1,450 rpm. The common shortcut 2π m² z b gives 7.84, 2.2 % low. Flow pulses with each tooth: ripple 17.8 %.

Gear and vane pumps in motion: displacement from the geometry, and a variable vane pump's eccentricity against flow: interactive loads as you scroll

What are internal gear, gerotor and lobe pumps, and where do they fit?

An internal gear pump runs a small external gear inside a ring gear, with a crescent filling the gap between them; the teeth unmesh slowly, so it is quiet. Bosch Rexroth puts its typical overall efficiency at 90 %, against 85 % for an external gear pump. A gerotor is an internal gear pump with no crescent: the inner rotor has one tooth fewer than the outer. Lobe pumps use two or three-lobed rotors driven by timing gears that do not touch, so they suit low-pressure transfer of thick or food liquids more than hydraulic power.

Why do gear pumps have relief grooves, and what limits their pressure?

For smooth drive a second tooth pair must touch before the first lets go. The default pump's contact ratio is 1.42, so for 42 % of each tooth pass two pairs touch and trap oil between them. That pocket shrinks; oil barely compresses, so pressure would spike and the bearings hammer. Grooves cut in the side plates vent it. Delivery pressure also pushes the gears sideways: about Δp × b × tip diameter, 7.28 kN at 100 bar for this pump. Bearings set the limit: AZPF gear pumps run continuously at up to 250 bar and 4,000 rpm (size 8).

How do unbalanced and balanced vane pumps differ?

Vanes slide in slots in a rotor and press on a ring. In an unbalanced pump the ring is offset by e, so each chamber grows on one side and shrinks on the other: V ≈ 2π e D b. Ring 70 mm, e 3 mm, 30 mm wide, 10 vanes 2 mm thick: 35.33 cm³/rev (39.58 by the shortcut, which ignores vane thickness). All the pressure sits on one side: 21 kN on the shaft at 100 bar. A balanced pump uses a cam ring with two lobes: two suction and two delivery zones face each other, the forces cancel, and V = 2π b (R2² − R1²) − 2 z t b (R2 − R1).

How does a variable vane pump change its flow, and what is a pressure compensator?

Flow is proportional to eccentricity, so moving the ring changes the displacement. A spring holds the ring at maximum offset; delivery pressure pushes it back. Below the compensator setting the pump gives full flow: 51.2 L/min for the default pump. Above it the ring centres: in this model half flow at 4 bar over the setting and zero 8 bar over. That is the flat-top curve. At zero stroke the pump still makes up its own leakage: Rexroth's PV7 (160 bar, 900-1,800 rpm) quotes 2.7 L/min for size 14, 0.72 kW of oil power that ends as heat.

Predict, then check

You double the module of a gear pump and keep the number of teeth and the face width. The displacement becomes about:

Worked examples

External gear pump displacement · Two identical spur gears: module 3 mm, 10 teeth, 20° pressure angle, face width 25 mm, standard addendum (= m). Speed 1,450 rpm, ηv 0.92.
  1. Pitch radius rp = 3 × 10/2 = 15 mm; tip radius ra = 15 + 3 = 18 mm; base pitch pb = π × 3 × cos 20° = 8.856 mm.
  2. ra² − rp² − pb²/12 = 324 − 225 − 6.536 = 92.464 mm².
  3. V = 2π × 25 × 92.464 = 14,524 mm³ = 14.52 cm³/rev (shortcut 2π m² z b = 14.14, 2.7 % low).
  4. Flow = 14.52 × 1,450/1,000 × 0.92 = 19.38 L/min.

Answer: 14.52 cm³/rev; 19.4 L/min.

Unbalanced vane pump · Ring diameter 80 mm, eccentricity 2.5 mm, width 35 mm, 10 vanes 2 mm thick. Speed 1,450 rpm.
  1. Shortcut V = 2π e D b = 2π × 2.5 × 80 × 35 = 43,982 mm³ = 43.98 cm³.
  2. Exact chamber geometry (thin vanes): 43.26 cm³; vane volume 2 z t b e = 2 × 10 × 2 × 35 × 2.5 = 3,500 mm³.
  3. V = 43.26 − 3.5 = 39.76 cm³/rev; flow = 57.7 L/min at 1,450 rpm.
  4. For 40 L/min the ring must sit at e = 1.73 mm (solved on the exact relation).

Answer: 39.76 cm³/rev, 57.7 L/min; e = 1.73 mm for 40 L/min.

Balanced vane pump and its side load · Cam ring minor radius 32 mm, major radius 35 mm, width 24 mm, 12 vanes 2 mm thick, 1,450 rpm, 100 bar.
  1. Thin-vane V = 2π × 24 × (35² − 32²) = 30,310 mm³.
  2. Vane volume = 2 × 12 × 2 × 24 × 3 = 3,456 mm³; V = 26.85 cm³/rev; flow 38.9 L/min.
  3. An unbalanced pump of the same size (ring 70 mm, 24 mm wide) needs e = 2.85 mm and carries about 100 × 10⁵ × 0.024 × 0.070 = 16.8 kN on its shaft.
  4. The balanced pump's two delivery zones face each other, so the net side load is zero.

Answer: 26.85 cm³/rev, 38.9 L/min, no side load.

Chapter 7

Piston pumps: swash plate, bent axis and radial piston pumps, and flow ripple

Which syllabus covers thisAU ME3492 Unit I (fixed and variable displacement pumps)VTU BME702 Module 2 (piston pumps, fixed and variable displacement)SPPU 302054 Practical 3 (piston pumps)MU not in syllabusKTU MET424 Module 2 (radial and axial plunger pumps)

How does a swash plate pump work, and what sets its displacement?

Pistons sit in bores of a cylinder block that turns with the shaft. Their slippers ride on a plate tilted at α, so each piston moves in and out once a turn, stroke Dp tan α, and a valve plate connects it to suction then delivery. Nine 18 mm pistons on a 64 mm circle at 18°, the maximum angle in Danfoss's Series 20 data: 47.62 cm³/rev, 69.1 L/min at 1,450 rpm. Tilt the plate less and the flow falls in proportion to tan α: that is how a variable piston pump works.

An axial piston pump: swash angle against displacement, the pistons in motion and the flow ripple of odd and even piston counts: interactive loads as you scroll

How is a bent-axis pump different?

The cylinder block is tilted to the drive shaft and the pistons are tied to the shaft flange by rods, so the stroke is Dp sin α. Large angles are possible: Parker's F11/F12 units use 40° between shaft and barrel. The same nine pistons give 61.9 cm³/rev at 25° and 94.2 at 40°, against 47.6 for the 18° swash plate. Bent-axis units are among the most efficient: Bosch Rexroth quotes typical overall efficiencies of 92 % bent axis, 91 % axial (swash plate) and 90 % radial piston.

Why do piston pumps use an odd number of pistons?

Each delivering piston pushes oil at a speed that varies as a sine wave, and the total flow is the sum of the pistons on the delivery side. With an even number, pistons arrive and leave in pairs and the sum jumps; with an odd number they alternate and the bumps half-cancel. Nine pistons: ripple 1.53 % at 435 Hz (2z × n/60). Eight pistons: 7.81 % at 193 Hz. Ripple shakes pipes and makes noise, so odd counts (Parker's 7 or 9) win.

What is a radial piston pump?

The pistons stand like spokes around an eccentric or cam on the shaft; each strokes twice the eccentricity, so V = z Ap × 2e. Seven 10 mm pistons on a 3 mm eccentric give 3.3 cm³/rev: small displacement, but the pistons are short and stiff and seal well, so radial pumps suit very high pressure at low flow, such as clamping, presses and test rigs. Bosch Rexroth puts their typical overall efficiency at 90 %. In the rotating-cylinder type the block turns inside a ring and the ring's offset can be varied.

How capable are piston pumps, and how efficient?

Rexroth's A10VSO, a common industrial swash plate pump, comes in 18 to 100 cm³ with 280 bar nominal and 350 bar maximum pressure; size 45 runs to 2,600 rpm and gives 68 L/min at 1,500 rpm. Its controllers move the swash plate: pressure compensation from 50 to 280 bar, flow control and load sensing (chapter 8). This book uses ηv 0.95 and ηm 0.958 at 280 bar and 50 °C (overall 0.91 from the Rexroth table, split assumed). The catch: close clearances need clean oil, and the optimum viscosity band is narrow, 16 to 36 mm²/s.

Predict, then check

A 9-piston pump has a flow ripple of about 1.5 %. You build the same pump with 10 pistons. The ripple becomes about:

Worked examples

Swash plate pump: displacement, flow and power · 9 pistons of 16 mm bore on a 60 mm pitch circle, swash angle 15°, 1,800 rpm, delivery 210 bar. ηv 0.95, ηo 0.91.
  1. Piston area = π/4 × 16² = 201.06 mm²; stroke = 60 × tan 15° = 16.077 mm.
  2. V = 9 × 201.06 × 16.077 = 29,092 mm³ = 29.09 cm³/rev.
  3. Flow = 29.09 × 1,800/1,000 × 0.95 = 49.75 L/min.
  4. Input power = 49.75 × 210/600/0.91 = 19.13 kW: a 22 kW motor.

Answer: 29.09 cm³/rev, 49.7 L/min, 19.1 kW.

Swash angle for a required flow · The same pump driven at 1,450 rpm must deliver 40 L/min (ηv 0.95).
  1. Displacement needed = 40/0.95/1,450 × 1,000 = 29.04 cm³/rev.
  2. tan α = V/(z Ap Dp) = 29,038/(9 × 201.06 × 60) = 0.2675.
  3. α = 14.97°, inside the 18° that Danfoss's Series 20 allows.

Answer: α ≈ 15°.

Ripple of 7 and 8 pistons · Pistons 18 mm on a 64 mm circle at 18°, 1,450 rpm. Compare 7 and 8 pistons.
  1. 7 pistons (odd): ripple = (π/14) tan(π/28) = 2.53 %; frequency = 2 × 7 × 1,450/60 = 338.3 Hz.
  2. 8 pistons (even): ripple = (π/8) tan(π/16) = 7.81 %; frequency = 8 × 1,450/60 = 193.3 Hz.
  3. Displacements 37.04 and 42.33 cm³/rev; the 8-piston pump ripples 3.1 times more.

Answer: 7 pistons: 2.53 % at 338 Hz; 8 pistons: 7.81 % at 193 Hz.

Chapter 8

Fixed and variable pumps: pressure-compensated and load-sensing control, and choosing a pump

Which syllabus covers thisAU ME3492 Unit I (performance, selection criteria of pumps)VTU BME702 Module 2 (pump performance characteristics, selection factors)SPPU 302054 (selecting components from catalogues)MU not in syllabusKTU MET397 Module 1 (pump selection and specification)

What does a fixed pump waste, and how does THE PRESS's high-low circuit limit it?

A fixed pump delivers its full flow all the time; whatever the cylinder does not take goes over a valve as heat. THE PRESS limits that with two pumps: both feed the rapid strokes, then the big one is unloaded at 3 bar (0.213 kW) while the small one presses. The dwell is the costly moment: the small pump's 10.67 L/min goes over the relief at 210 bar and the shaft takes 4.77 kW, all of it heat. Per cycle the shafts take 50.4 kJ; only 5.4 kJ leaves as work on the workpiece, so 2.53 kW heats the oil.

What does a pressure-compensated pump do, and does it save energy on THE PRESS?

It gives full flow until the outlet reaches its setting, then shortens its stroke to hold that pressure with just the flow needed: the flat-top curve. In the dwell a 40 cm³ PC piston pump only makes up its own leakage, 2.18 L/min, and takes 0.79 kW instead of 4.77. But pressing at 8.85 mm/s needs a flow control valve, and the pump holds 210 bar while the load climbs from 20: 6.06 kJ is throttled. Net, at a 2 s dwell: 46.1 kJ a cycle, 8.6 % less than the high-low pumps; longer dwells save more.

The press cycle on a fixed pump with relief, a pressure-compensated pump and a load-sensing pump: power used and heat made: interactive loads as you scroll

How does a load-sensing pump work, and why does it lose on THE PRESS?

A small line carries the load pressure back to the pump, which holds its outlet a fixed margin above it, so the control valve drops only that margin. Rexroth's A10VSO flow controller uses 14 bar as standard (14-22 bar). On THE PRESS the rapid strokes need 53.36 L/min at only 20-30 bar, so the margin adds 47-70 %: 1.25 kW in every rapid stroke. At a 2 s dwell the LS pump takes 54.6 kJ, 8.3 % MORE than the fixed pumps; it wins only beyond a 3.1 s dwell. Load sensing pays on machines with several actuators at part flow and higher loads, such as excavators and cranes.

What other ways cut the waste of a fixed pump, and how fair is this comparison?

Unload the pump whenever no flow is needed: a tandem-centre directional valve or an unloading valve dumps it to tank at a few bar. Store oil in an accumulator charged by a small pump between strokes (chapter 19), or slow the motor with a variable-speed drive. A 10 s dwell would cost 88.5 kJ a cycle on the fixed pumps against 52.4 kJ with a PC pump. All three supplies here use the kernel's constant ηm and ignore drag at low pressure; with chapter 5's drag model the fixed pair would take about 61 kJ, so real savings are larger.

How do you choose between gear, vane and piston pumps?

Pressure first: Rexroth's AZPF gear pumps run continuously at up to 250 bar, the PV7 vane pump at 160 bar and the A10VSO piston pump at 280 bar. Speed: gear 4,000 rpm (small sizes), vane 900-1,800 rpm, piston 2,600 rpm (size 45). Efficiency: typical overall 85 % gear and vane, 91 % axial piston (Rexroth table). Noise: a 9-piston pump ripples about 1.5 %, chapter 6's gear pump 18 %. Variable flow: vane or piston only. Dirt and cost favour the gear pump; the PV7 asks for oil at least as clean as ISO 4406 20/18/15.

Predict, then check

THE PRESS's dwell at full force is lengthened from 2 s to 10 s. Which supply now uses the least energy per cycle?

Worked examples

What THE PRESS's fixed pumps cost a day · THE PRESS at 202 strokes an hour, two 8-hour shifts, ₹8/kWh (the book's assumed tariff). Per cycle the shafts take 50.39 kJ in 17.81 s.
  1. Mean shaft power = 50.39/17.81 = 2.829 kW.
  2. Energy a day = 2.829 × 16 = 45.3 kWh at the shaft.
  3. Of each cycle, 7.47 kJ goes over the relief and 1.15 kJ through the unloading valve: 17.1 % of the input.
  4. Cost = 45.3 × 8 = ₹362 a day at the shaft (more at the meter, after motor losses). A PC pump would take 41.4 kWh.

Answer: 45.3 kWh and about ₹362 a day.

Throttling loss of a PC pump while pressing · PC pump set at 210 bar; pressing at the small pump's 10.672 L/min for 3.39 s while the load rises linearly from 20 to 198.94 bar.
  1. Mean load pressure = (20 + 198.94)/2 = 109.47 bar.
  2. Pressure dropped across the flow control valve, on average = 210 − 109.47 = 100.53 bar.
  3. Power throttled = 10.672 × 100.53/600 = 1.788 kW; × 3.39 s = 6.06 kJ.
  4. The dwell saves (4.77 − 0.79) × 2 = 7.95 kJ, so throttling eats most of the gain: net 4.34 kJ a cycle.

Answer: 6.06 kJ a cycle throttled; net saving 8.6 %.

How fast THE TANK heats with no cooler · THE PRESS's fixed pumps: 50.39 kJ in per 17.81 s cycle, 5.397 kJ of it done on the workpiece. THE TANK holds 160.1 L of VG 46 at 50 °C (cp 1,880 J/(kg·K)); its walls shed 237.5 W into 40 °C air (chapter 4).
  1. Heat load = (50.39 − 5.397)/17.81 = 2.526 kW; the 20-30 bar of friction and back pressure end as heat too.
  2. Net heat into the oil = 2.526 − 0.237 = 2.289 kW.
  3. Oil mass = 160.1 L × 835.6 kg/m³ = 133.8 kg; rise = 2,289 × 3,600/(133.8 × 1,880) = 32.8 °C an hour.
  4. A 400 L tank sheds 437 W and still rises 12 °C/h: the press needs a cooler of about 2.3 kW.

Answer: About 33 °C an hour; a cooler of about 2.3 kW holds 50 °C.

Chapter 9

Hydraulic cylinders: force, speed, area ratio, mountings and rod buckling

Which syllabus covers thisAU ME3492 Unit II (cylinders: types, construction, application)VTU BME702 Module 2 (cylinders, mounting arrangements, problems)SPPU 302054 Practical 2 (linear actuators)MU not in syllabusKTU MET424 Module 3 (linear hydraulic actuators)

What kinds of hydraulic cylinder are there, and when would you pick each?

A single-acting cylinder pushes with oil and comes back by a spring or the load's weight: car hoists, jacks. A double-acting cylinder has oil on both sides of the piston and works both ways: THE PRESS uses one. A double-rod cylinder has a rod out of each end, so both areas are equal: a 160/100 double-rod cylinder on THE PRESS's 53.36 L/min would move at 72.6 mm/s both ways. A telescopic cylinder nests several stages for a long stroke from a short body (tipper trucks). A tandem cylinder puts two pistons on one rod and nearly doubles the force from the same bore: up to about 844 kN at 210 bar for a 160 mm bore.

What is inside a cylinder, and what do tie-rod and mill-type mean?

A honed steel barrel, a piston with its seals and guide ring, a hard chromium-plated rod, a gland at the head with the rod seal and the scraper (wiper), and end caps with the ports. A tie-rod cylinder clamps the end caps with long bolts: cheap, for moderate pressure. A mill-type cylinder bolts or screws the heads on and suits heavy duty: Rexroth's CDL2 data sheet rates its mill-type range at 160 or 250 bar nominal, tests it statically at 240 or 375 bar, asks for at least 10 bar to move with no load, limits stroke speed to 0.5 m/s and oil cleanliness to ISO 4406 20/18/15.

How do you get a cylinder's force and speed, and what does the area ratio do?

Force is pressure times the area it acts on; speed is flow divided by that area. THE PRESS's 160 mm bore has A1 = 201.06 cm², so 400 kN needs 198.94 bar; at the 210 bar relief it can push 422.2 kN and pull 257.3 kN on the 122.52 cm² annulus. The same 53.36 L/min extends it at 44.23 mm/s and retracts it at 72.59 mm/s. The area ratio φ = A1/A2 = 1.641 sets both ratios: the return is φ times faster and φ times weaker.

How does the way a cylinder is mounted change its buckling length?

The rod is a column, so what holds its two ends decides the free buckling length LK. Rexroth's data sheet uses three cases: body rigidly mounted (front or rear flange, foot) with the rod end pinned and guided, LK = 0.7 L; pivoted at both ends (rear clevis, trunnion), LK = L; body rigid but rod end free, LK = 2 L. L runs from the mounting point to the rod-end pin at full stroke, so a rear clevis has nearly twice the free length of a front flange. THE PRESS is front-flanged to its crown with the platen guided by the columns: L = 560 mm, LK = 392 mm.

How do you check a cylinder rod against buckling the way a maker does?

Slenderness λ = 4 LK/d. Above λg (about 85 here) use Euler's load π²EI/LK²; below it Tetmajer's short-column line d²π(335 − 0.62λ)/4; then divide by Rexroth's safety factor 3.5. THE PRESS's 100 mm rod has λ = 15.7, so Tetmajer gives 2,555 kN against 422.2 kN at relief: safety factor 6.05, and it would pass up to a 3,588 mm stroke. Free the rod end and the limit drops to 1,152 mm. The maker's own tables run 3-22 % shorter than this plain estimate (they add self-weight and guide play). The Strength of Materials book covers the Euler theory.

Sizing a hydraulic cylinder: bore and rod against force and speed, area ratio, and the buckling limit of the rod for each mounting: interactive loads as you scroll
Predict, then check

A cylinder's rod end loses its guide: the same free length L goes from LK = 0.7 L to LK = 2 L. Its Euler buckling load falls to about what share?

Worked examples

THE PRESS cylinder: pressure for full force, speeds and stroke times · Bore 160 mm, rod 100 mm, force 400 kN, pumps 8 + 32 cm³/rev at 1,450 rpm and ηv 0.92; approach 330 mm, return 360 mm, relief 210 bar.
  1. A1 = π × 0.16²/4 = 0.020106 m²; A2 = A1 − π × 0.1²/4 = 0.012252 m²; φ = 1.641.
  2. Pressure for 400 kN = 400,000/0.020106 = 19.894 MPa = 198.94 bar.
  3. Flow = (8 + 32) × 1,450/1,000 × 0.92 = 53.36 L/min = 889.3 cm³/s.
  4. Extend speed = 0.000889/0.020106 = 44.23 mm/s: 330 mm in 7.46 s.
  5. Retract speed = 0.000889/0.012252 = 72.59 mm/s: 360 mm in 4.96 s.
  6. At the 210 bar relief: push = 210 × 10⁵ × 0.020106 = 422.2 kN, pull = 257.3 kN.

Answer: 198.94 bar for 400 kN; 44.23 mm/s out (7.46 s), 72.59 mm/s back (4.96 s); 422.2 / 257.3 kN at relief.

Choosing ISO 3320 bore and rod for a lifting cylinder · An assumed lifting cylinder: 63 kN load, 100 bar working pressure, 40 L/min, retract about twice as fast as extend.
  1. Bore needed = √(4 × 63,000/(π × 10 × 10⁶)) = 0.0896 m = 89.6 mm: next ISO 3320 bore 100 mm.
  2. Pressure actually needed = 63,000/0.007854 = 80.2 bar (margin to 100 bar for friction).
  3. For φ = 2 the rod would be 100/√2 = 70.7 mm: nearest ISO rod 70 mm gives φ = 1.961.
  4. Extend speed = 40/60,000/0.007854 = 84.9 mm/s; retract = 40/60,000/0.004006 = 166.4 mm/s.

Answer: 100/70 mm: 80.2 bar to lift, 84.9 mm/s up, 166.4 mm/s down (φ 1.96).

Buckling check of a long rear-clevis cylinder, and the fix · An assumed cylinder 100/56 mm, stroke 1,200 mm, 160 bar, rear clevis (pinned both ends). Model: L = 2 × stroke + (2.2 D + 40) mm. E 2.1 × 10⁵ N/mm², safety factor 3.5.
  1. Push = 160 × 0.1 N/mm² × π × 100²/4 = 125.66 kN.
  2. L = 2 × 1,200 + 260 = 2,660 mm; LK = L (pinned both ends); λ = 4 × 2,660/56 = 190 > λg 85.4: Euler.
  3. I = π × 56⁴/64 = 482,750 mm⁴; Fcr = π² × 2.1 × 10⁵ × 482,750/2,660² = 141.4 kN.
  4. Safety factor = 141.4/125.66 = 1.13, far below 3.5. Longest stroke: LK = π√(EI/(3.5 F)) = 1,508 mm, so stroke = (1,508 − 260)/2 = 624 mm (Rexroth's CDL2 table for a 100/56 clevis cylinder at 160 bar: 545-580 mm).
  5. Fix: front flange with the rod end guided: L = 1,200 + 100 = 1,300 mm, LK = 910 mm, λ = 65: Tetmajer gives 726 kN, safety factor 5.78.

Answer: As drawn it buckles (safety factor 1.13, longest stroke 624 mm); front-flanged and guided it passes with 5.78.

Chapter 10

Cylinder cushioning and seals: stopping a moving load at the end of the stroke

Which syllabus covers thisAU ME3492 Unit II (hydraulic cushioning)VTU BME702 Module 2 (cushioning, special cylinders), Module 1 (seals)SPPU not in syllabusMU not in syllabusKTU MET424 Module 3 (cylinder cushions)

Why does a cylinder need a cushion at the end of its stroke?

Because the moving load carries kinetic energy that has to go somewhere. An assumed 800 kg slide at 0.4 m/s carries ½mv² = 64 J. Stopped on 0.5 mm of steel at the end cap, that is an average force of 128 kN, a bang that loosens heads, cracks welds and wears seals. Spread over a 30 mm cushion, the same energy needs only 2,133 N. Rexroth's CDL2 data sheet sets a 0.5 m/s stroke-speed limit and sells that range without end position damping, so fast or heavy loads need a cushioned cylinder or an external shock absorber.

How does a cushion actually brake the piston?

Near the end a spear on the piston enters a bore in the end cap. The oil left between piston and cap can no longer reach the port, only a needle valve, so its pressure rises and pushes back. A check valve lets oil in round the needle so the cylinder can start back out at full speed. On the assumed slide (80/45 cylinder, 32 mm spear, 160 bar relief) the model peaks at 154 bar, takes 258 ms and ends at 77.8 mm/s, far under the 240 bar static test pressure we take as the ceiling.

End-of-stroke cushioning: the load's kinetic energy, cushion length, cushion pressure peak and deceleration: interactive loads as you scroll

What pressure does a cushion see, and why can it exceed the system pressure?

The supply keeps pushing on the drive side while the trapped oil brakes, so the cushion carries the drive force plus the load's kinetic energy over the cushion length. For constant deceleration on the slide: (160 bar × 34.36 cm² + 64 J/0.03 m)/42.22 cm² = 135.3 bar. The drive alone is 130.2 bar of it; the kinetic energy only 5.05 bar. With a big annulus and a small trapped area the cushion pressure can climb above the relief setting: that intensification is why the ceiling is the cylinder's test pressure, not the relief.

What do the needle valve, a tapered spear and an external decelerator change?

The needle sets the creep speed at the end: with the supply at relief the trapped pressure settles at the drive force over the trapped area, and the needle passes just enough oil for that. On the slide 3 mm² gives 77.8 mm/s; closing it to 0.5 mm² at 500 mm/s entry gives 13 mm/s, 185 bar peak and a slow 1,280 ms finish. A tapered spear lets oil escape round it at first, so the pressure rises gently instead of spiking. Fixed cushions have no needle. External shock absorbers take the energy outside the cylinder.

Which seals does a cylinder use, and what happens when they leak?

Rexroth's CDL2 seal kit lists the scraper (wiper) that keeps dirt off the rod, the rod seal, the piston seal, an O-ring and the guide ring. Its standard 'M' seals suit HL and HLP oil from −20 to +80 °C; the FKM 'V' version goes to +120 °C and suits fire-resistant HFDR fluids; the sheet recommends oil near 40 °C. A worn piston seal leaks across the piston: 1 cm³/min on THE PRESS's 201 cm² piston lets a held load creep 0.05 mm a minute. Chapter 24 finds that fault.

Predict, then check

THE PRESS returns upward at 72.6 mm/s into its 25 mm top cushion. Where does most of the energy the cushion turns into heat come from?

Worked examples

Cushion pressure for a horizontal slide (constant deceleration) · An assumed slide: 800 kg at 0.4 m/s, cylinder 80/45 mm, spear 32 mm, cushion length 30 mm, relief 160 bar on the rod side, friction neglected.
  1. A1 = π × 0.08²/4 = 50.27 cm²; A2 = 34.36 cm²; spear 8.04 cm²; trapped Ac = A1 − spear = 42.22 cm².
  2. Drive force = 160 × 10⁵ × 0.003436 = 54.98 kN.
  3. Kinetic energy = ½ × 800 × 0.4² = 64 J; over 30 mm that is 2,133 N.
  4. p = (54,978 + 2,133)/0.004222 = 135.3 bar; deceleration v²/(2L) = 2.67 m/s².
  5. Ceiling: 1.5 × 160 bar = 240 bar static test pressure: OK. The model with a real needle peaks at 154 bar.

Answer: About 135 bar in the cushion (drive 130.2 + inertia 5.1), well under 240 bar.

Needle opening for a chosen creep speed · The same slide; the cylinder should arrive at 50 mm/s. Oil ρ 835.6 kg/m³ at 50 °C, Cd 0.62.
  1. At creep the trapped pressure balances the drive: p = 54.98 kN/42.22 cm² = 130.2 bar.
  2. Jet speed through the needle = √(2 × 13,020,833/835.6) = 176.5 m/s.
  3. Flow to pass = Ac × v = 0.004222 × 0.05 = 211.1 cm³/s.
  4. Area = 211.1 cm³/s/(0.62 × 176.5 m/s) = 1.93 mm².
  5. Check: 3 mm² gives 77.8 mm/s, as the interactive shows.

Answer: Open the needle to about 1.9 mm².

THE PRESS's top cushion: trapped pressure and creep speed · THE PRESS returning upward: 160/100 mm, spear 63 mm (assumed), platen 1,500 kg, relief 210 bar on the annulus, needle 3 mm².
  1. Trapped area Ac = 201.06 − 31.17 = 169.89 cm².
  2. Net drive = 210 × 10⁵ × 0.012252 − 1,500 × 9.81 = 242.59 kN.
  3. Trapped pressure at creep = 242.59 kN/169.89 cm² = 142.8 bar (below the 375 bar ceiling).
  4. Creep speed = 0.62 × 3 mm² × √(2 × 14,279,075/835.6)/169.89 cm² = 20.2 mm/s.
  5. Kinetic energy at 72.6 mm/s = 3.95 J: the cushion here mainly meters the pump, not momentum.

Answer: 142.8 bar in the cushion and a 20.2 mm/s finish (the model: peak 152 bar, 806 ms).

Chapter 11

Hydraulic motors: gear, vane, piston and orbital motors, torque, speed and efficiency

Which syllabus covers thisAU ME3492 Unit II (rotary actuators, hydraulic motors)VTU BME702 Module 2 (gear, vane and piston motors, torque, power, performance)SPPU 302054 Practical 2 (rotary actuators)MU not in syllabusKTU MET424 Module 3 (hydraulic motors, motor performance)

What types of hydraulic motor are there, and what is high-speed or low-speed high-torque?

A hydraulic motor is a pump run backwards: oil pushes the gears, vanes or pistons round. Gear and vane motors are cheap and compact; axial piston motors (swash plate or bent axis) are the most efficient and can vary displacement. These are high-speed low-torque (HSLT) motors and usually drive through a gearbox. Orbital (gerotor) and radial piston motors are low-speed high-torque (LSHT): Danfoss's OMT range runs 161-524 cm³/rev at 240-625 rpm, and its orbital family reaches 800 cm³/rev and 3,400 N·m peak, enough to turn a drum or wheel directly.

How do displacement, pressure and flow give a motor's torque, speed and power?

Torque comes from displacement times pressure drop, less mechanical loss; speed from flow over displacement, less leakage. A Danfoss OMT 160 at 200 bar has a theoretical torque of 513 N·m and gives 460 N·m, so ηhm = 0.9; at 460 rpm it swallows 80 L/min against 74.1 L/min theoretical, ηv = 0.93. Overall about 83 % (Danfoss rounds 93 × 90 to 84 %). Power out = torque × speed; power in = flow × pressure drop.

Why can a motor that runs a load fail to start it?

At standstill there is no oil film, so friction is highest. Hydraulics & Pneumatics puts the running torque of gear, vane and piston motors near 90 % of theoretical but the starting torque at 70-80 %; Danfoss's orbital data give 66-74 %. The winch here (300 mm drum, 10 kN at 20 m/min) on an OMV 800 runs at 131 bar but needs 159 bar to break away, under the 210 bar relief. A gear motor sized to run at 180 bar would need 231 bar to start: it stalls.

A hydraulic motor driving a winch: displacement against torque and speed, starting torque, efficiency and the pump it needs: interactive loads as you scroll

What do motor leakage and oil viscosity do at low speed and when holding a load?

Leakage means a motor cannot hold a load by itself: oil slips past and the shaft creeps. If 1 L/min leaked through an OMV 800 holding the winch, the drum would turn 1.25 rpm and the rope would pay out about 1.2 m a minute, so winches use a spring-applied brake or a counterbalance valve. Danfoss advises 3-5 bar return pressure and at least 35 mm²/s for smooth low-speed running: THE OIL is only 30.5 mm²/s at 50 °C and reaches 35 mm²/s below 46.5 °C.

What is a limited-rotation (rotary) actuator?

A motor that turns less than a full revolution, for valves, indexing tables, clamps and steering. A rack-and-pinion actuator drives a gear with a piston rack. A vane actuator has one or two vanes swinging in a housing: torque = p × width × (R² − r²)/2 per vane. An assumed single vane, 50 mm wide, rotor 20 mm and housing 60 mm radius, at 100 bar gives 800 N·m. Double vanes double the torque and halve the angle.

Predict, then check

A gear motor (via a 30:1 gearbox) is sized so it just runs the winch at 180 bar. The relief is 210 bar. Will it start the hanging load?

Worked examples

Torque, speed and power of an orbital motor · A Danfoss OMV 400 (400.9 cm³/rev) fed 60 L/min at a 150 bar pressure drop; ηv 0.93, ηhm 0.90 (Danfoss OMT 160 example values).
  1. Torque = 400.9 × 150 × 0.90/(20π) = 861.4 N·m.
  2. Speed = 1,000 × 60 × 0.93/400.9 = 139.2 rpm.
  3. Power out = 861.4 × 2π × 139.2/60 = 12.55 kW; power in = 60 × 150/600 = 15 kW.
  4. Overall efficiency = 12.55/15 = 0.837 (= 0.93 × 0.90).
  5. Starting torque at 150 bar with Danfoss's minimum (910 N·m at 200 bar, η start 0.713) = 682 N·m.

Answer: 861 N·m at 139 rpm, 12.6 kW out of 15 kW in; it can break away 682 N·m.

Sizing an orbital motor for a hoist winch · Drum 300 mm, rope pull 10 kN, rope speed 20 m/min, working pressure drop 150 bar, direct drive; Danfoss OMT/OMV sizes; relief 210 bar; pump on a 1,450 rpm motor (ηv 0.92, ηm 0.90).
  1. Drum torque = 10,000 × 0.15 = 1,500 N·m; drum speed = 20/(π × 0.3) = 21.22 rpm; load power 3.33 kW.
  2. Displacement needed = 2π × 1,500/(150 × 10⁵ × 0.90) = 698 cm³/rev: OMV 630 is too small, take OMV 800 (801.8).
  3. Running pressure drop = 2π × 1,500/(801.8 × 10⁻⁶ × 0.90) = 130.6 bar (limit 160 continuous).
  4. Flow = 801.8 × 21.22/1,000/0.93 = 18.3 L/min; pump = 18.3/(1,450 × 0.92) = 13.7 cm³/rev, 4.81 kW.
  5. Start: η start = 1,510/(801.8 × 160/20π) = 0.74, so Δp to start = 158.9 bar ≤ 210: it starts.

Answer: OMV 800: 131 bar to run, 159 bar to start, 18.3 L/min from a 13.7 cm³/rev pump.

A gear motor and gearbox on the same winch · Same winch; gear motor through a 30:1 planetary gearbox (η 0.95, assumed); gear motor ηv 0.90, ηhm 0.90, starting 0.70 (assumed inside H&P's 70-80 %); first sized at 180 bar.
  1. Motor torque = 1,500/(30 × 0.95) = 52.6 N·m; motor speed = 21.22 × 30 = 637 rpm.
  2. Displacement at 180 bar = 2π × 52.63/(180 × 10⁵ × 0.90) = 20.4 cm³/rev; flow = 14.4 L/min.
  3. Start pressure = 180 × 0.90/0.70 = 231 bar > 210 bar relief: it will not start.
  4. Resize at 150 bar: 24.5 cm³/rev, start 193 bar: starts. An axial piston motor (starting 0.80) at 180 bar would need 202 bar and start too.

Answer: At 180 bar it stalls (231 bar to start); a 24.5 cm³/rev motor sized at 150 bar starts at 193 bar.

Chapter 12

Hydrostatic transmissions and mobile hydraulics: pump-motor drives for vehicles and winches

Which syllabus covers thisAU ME3492 Unit III (hydrostatic transmission), Unit V (mobile hydraulics, forklift)VTU not in syllabusSPPU 302054 (mobile hydraulic applications)MU not in syllabusKTU MET424 Module 5 (hydraulic motor braking system)

What is the difference between an open and a closed hydraulic circuit?

In an open circuit the pump draws from the tank and the oil returns to the tank through valves: THE PRESS works this way. In a closed circuit the pump's outlet feeds the motor and the motor's outlet goes straight back to the pump inlet; reversing the pump's swash plate reverses the motor. A small charge pump (assumed 25 bar here) tops up the leakage through check valves and keeps the low side pressurised, and two crossport reliefs cap each side. Our assumed 7 t loader circulates 120 L/min round its loop with a small tank.

What are the four pump-motor combinations of a hydrostatic transmission?

Fixed pump, fixed motor: one speed ratio, speed only from the engine. Variable pump, fixed motor: speed from zero up at constant maximum torque (region 1 of the curve). Fixed pump, variable motor: less motor displacement means more speed and less torque at constant power (region 2). Variable pump and variable motor: both, which is what vehicles use. On the loader the pump strokes up to 6.2 km/h at 31.2 kN, then the motor de-strokes to 25 % for 24.9 km/h at 7.8 kN.

How does a hydrostatic drive produce its tractive-force against speed curve?

Pressure sets torque, flow sets speed. With the motor at full displacement and the relief at 350 bar (325 bar across the motor), the wheels get 31.2 kN until the pump reaches full stroke at 6.23 km/h: the corner. Beyond it the motor de-strokes and force × speed stays at 54 kW at the wheels. The engine supplies 72 of its 75 kW, so the drive is 75 % efficient from shaft to tyre. Above 41.2 kN the tyres would just slip.

A hydrostatic drive: variable pump then variable motor, tractive force against vehicle speed, and the corner power: interactive loads as you scroll

How steep a slope can the loader climb, and what limits it?

On a slope the drive must lift the weight's component plus roll: W (sin θ + 0.04 cos θ). The loader weighs 68.6 kN; its 31.2 kN maximum force climbs a 46 % grade by hydraulics. Traction caps it too: with adhesion 0.6 the tyres hold to a 56 % grade. On the flat, rolling resistance is only 2.75 kN, so at top speed the 7.8 kN available is plenty. Raise the relief or the motor size for more grade, and check the engine can feed the corner power.

Where else do mobile machines use hydraulics, and how does a hydrostatic drive brake?

A forklift lifts its mast with single-acting cylinders and tilts it with double-acting ones; an excavator uses a load-sensing pump (chapter 8) so the pump only makes the pressure the heaviest function needs. To brake, a hydrostatic drive lets the wheels drive the motor as a pump: the loader at 24.9 km/h carries 168 kJ, which the pump returns to the engine or the crossport relief turns into heat.

Predict, then check

On the loader, halve the motor's minimum displacement (25 % of maximum → 12.5 %). What happens at top speed?

Worked examples

The corner point of a wheel loader's hydrostatic drive · Assumed 7 t loader: engine 2,300 rpm, pump 55 cm³/rev, motor 107 cm³/rev, relief 350 bar, charge 25 bar, ratio 40, wheel radius 0.62 m, axle η 0.92, pump and motor ηv = ηhm = 0.95.
  1. Pump flow = 55 × 2,300 × 0.95/1,000 = 120.17 L/min; Δp = 350 − 25 = 325 bar.
  2. Motor torque = 107 × 325 × 0.95/(20π) = 525.8 N·m; at the wheels × 40 × 0.92 ÷ 0.62 = 31.21 kN.
  3. Motor speed = 120.17 × 0.95 × 1,000/107 = 1,067 rpm; wheel 26.7 rpm; v = 1.732 m/s = 6.23 km/h.
  4. Wheel power = 31.21 × 1.732 = 54 kW; pump shaft = 55 × 2,300/1,000 × 325/600/0.95 = 72.1 kW ≤ 75 kW engine.

Answer: Corner at 6.23 km/h and 31.2 kN: 54 kW at the wheels from 72 kW of engine.

Top speed with the motor de-stroked, and the motor size for 30 km/h · The same loader; motor minimum displacement 25 % (26.75 cm³/rev).
  1. Speed scales as 1/Vm: 6.23 × 107/26.75 = 24.94 km/h.
  2. Force scales as Vm: 31.21 × 0.25 = 7.8 kN; power 7.8 × 6.927 = 54 kW, the same as at the corner.
  3. For 30 km/h: Vm,min = 107 × 6.23/30 = 22.2 cm³/rev (21 %).
  4. At part throttle (1,500 rpm) every speed falls by 1,500/2,300: top 16.3 km/h.

Answer: 24.9 km/h at 7.8 kN; 22.2 cm³/rev minimum for 30 km/h.

Gradeability of the loader · 7,000 kg, maximum tractive force from the corner example, rolling resistance coefficient 0.04, adhesion 0.6.
  1. Weight W = 7,000 × 9.81 = 68.65 kN; rolling on the flat = 0.04 W = 2.75 kN.
  2. Hydraulic limit: 68.65 (sin θ + 0.04 cos θ) = 31.21 gives θ = 24.7°, a 46.1 % grade.
  3. Traction limit: μ cos θ = sin θ + 0.04 cos θ, so tan θ = 0.6 − 0.04: 56 % grade.
  4. The smaller wins: 46 %. A 90 cm³/rev pump with a 420 bar relief pulls 37.9 kN but needs 143 kW at the corner, almost twice the engine.

Answer: About 46 % (hydraulic limit); the tyres would hold to 56 %.

Chapter 13

Directional control valves: ways, positions, centre conditions, actuation and symbols

Which syllabus covers thisAU ME3492 Unit II (direction control valves, fluid power symbols)VTU BME702 Module 3 (DCVs: poppet, spool, shuttle and check valves, symbols)SPPU 302054 (direction control valves)MU not in syllabusKTU MET424 Module 4 (directional control valves)

What do 'ways' and 'positions' mean in a 4/3 valve, and how is it drawn?

Ways are the ports: P from the pump, T to the tank, A and B to the actuator. Positions are the places the spool can stop. A 4/3 valve has four ports and three positions. The ISO 1219-1 symbol draws one square per position, arrows for the paths and a T-bar for a blocked port. The ports are drawn on the square that is active now; imagine the squares sliding sideways when the valve shifts. THE PRESS uses a 4/3 valve: left square P to A (platen down at 8.85 mm/s on the small pump), right square P to B (up at 14.52 mm/s), centre square to hold.

What does the centre condition decide, and what does it cost on THE PRESS?

It decides what the pump and the cylinder do when the valve is in neutral. Closed centre blocks all ports: the platen is held, but the small pump has nowhere to go and runs over the relief at 210 bar, turning 4.51 kW into heat. Tandem joins P to T and blocks A and B: it still holds, and the pump idles at 3 bar for 0.064 kW. Open centre joins everything and float joins A and B to tank: the pump idles (open) or deadheads (float), and the platen falls unless a counterbalance valve holds it. Pick each centre in the interactive and read the chips.

A 4/3 directional valve in section and as a symbol: spool positions and centre types, and what the cylinder and pump do in each: interactive loads as you scroll

Why can't a spool valve hold a load still?

A spool slides in its bore with a radial clearance of a few micrometres, and oil seeps through that annular gap. The flow grows with the cube of the clearance. For a 10 mm spool, 1.5 mm overlap and 6 µm clearance at 50 °C, one land passes 8.88 mL/min at 100 bar. THE PRESS held by a closed centre creeps down at 0.31 mm/min, because pump pressure leaks into both chambers and the cap side is bigger. Wear the clearance to 15 µm and it is 4.9 mm/min, 292 mm in an hour. Where a load must not move, a poppet valve (a pilot-operated check) holds it.

How do poppet, spool and rotary valves differ, and what do check, pilot-operated check and shuttle valves do?

A poppet presses onto a seat: leak-tight when shut, quick, but hard to balance against high pressure. A spool slides in a bore: easy to make with many paths and centres, but it leaks. A rotary valve turns a drilled plug: simple, low pressure. A check valve lets oil through one way only. A pilot-operated check also opens backwards when pilot pressure pushes its piston; with an assumed 4:1 area ratio, the 12 bar the platen weight makes needs only 3 bar of pilot. A shuttle valve passes the higher of two pressures, as in load sensing.

How is a directional valve shifted, and when is a pilot-operated valve needed?

By a lever (the operator, often with detents), a mechanical cam or roller, a solenoid (an electromagnet pushing the spool; springs centre it when switched off) or pilot oil from a small valve. Oil leaving a metering edge pushes back on the spool. At THE PRESS's rapid-approach flow, 53.36 L/min through one 20 mm² edge drops 21.5 bar and the jet (69° to the axis for a sharp edge) pushes 19 N, and it grows with flow squared. Big valves therefore use a small solenoid valve to pilot a big main spool (two-stage).

Predict, then check

THE PRESS waits in the centre position between strokes with a closed-centre valve and fixed pumps. Where does the small pump's power go?

Worked examples

Power wasted by the centre condition · THE PRESS's small pump: 8 cm³/rev at 1,450 rpm, ηv 0.92, ηm 0.90. Closed centre (relief 210 bar) against tandem centre (3 bar). Electricity ₹8/kWh.
  1. Flow: Q = 8 × 1,450 × 0.92 / 1,000 = 10.672 L/min.
  2. Torque at 210 bar: T = V Δp / (2π ηm) = 8 × 10⁻⁶ × 210 × 10⁵ / (2π × 0.90) = 29.71 N·m.
  3. Shaft power: P = T ω = 29.71 × 2π × 1,450 / 60 = 4,511 W = 4.51 kW, all of it heat.
  4. Tandem centre at 3 bar: P = 64.4 W.
  5. Saving per hour of waiting: 4.45 kWh × ₹8 = ₹35.6.

Answer: Closed centre wastes 4.51 kW, tandem 0.064 kW: about ₹36 for every hour the press waits.

Drift of a platen held by a closed-centre spool · Spool 10 mm, sealing overlap 1.5 mm, radial clearance 6 µm, oil at 50 °C. Each work port leaks across one land to P (210 bar) and one to T. Cylinder 160/100 mm, platen 1,500 kg.
  1. Oil viscosity at 50 °C: ν = 30.5 mm²/s, ρ = 835.6 kg/m³, µ = 25.46 mPa·s.
  2. Land conductance: g = π d c³ / (12 µ L) = π × 0.010 × (6 × 10⁻⁶)³ / (12 × 0.02546 × 0.0015) = 1.481e-14 m³/(s·Pa).
  3. Areas: A1 = 0.020106 m², A2 = 0.012252 m²; weight W = 14,710 N.
  4. Port flows and force balance give v = g [(A1 − A2) pP + 2W] / (A1² + A2²) = 5.191e-06 m/s.
  5. That is 0.311 mm/min, with the cap at 69.8 bar and the rod side at 126.5 bar.
  6. At 15 µm clearance the leak is (15/6)³ = 15.62 times larger: 4.87 mm/min.

Answer: 0.31 mm/min when new, 4.9 mm/min when worn to 15 µm: hold loads with a pilot-operated check, not a spool.

Sizing the valve for the rapid approach · THE PRESS's rapid approach: both pumps, 53.36 L/min through P to A. Oil at 50 °C, Cd 0.62. Each metering edge of an assumed small valve opens 20 mm².
  1. Velocity in the edge: v = Q / (Cd A) = 0.000889 / (0.62 × 20 × 10⁻⁶) = 71.7 m/s.
  2. Drop per edge: Δp = ρ v² / 2 = 21.5 bar; two edges (P to A, B to T) waste up to 3.82 kW.
  3. For 5 bar per edge: A = Q / (Cd √(2Δp/ρ)) = 0.000889 / (0.62 × 34.59) = 41.5 mm².
  4. On the slow pressing flow (10.67 L/min) the small valve drops only 0.86 bar per edge.

Answer: The 20 mm² valve drops 21.5 bar per edge at rapid approach; choose a valve with about 41 mm² per edge (the next size up).

Chapter 14

Pressure control valves: relief, reducing, sequence, counterbalance and unloading valves

Which syllabus covers thisAU ME3492 Unit II (pressure control valves, pressure switches)VTU BME702 Module 3 (pressure control valves, direct and pilot operated)SPPU 302054 (pressure control valves)MU not in syllabusKTU MET424 Module 4 (pressure control valves)

How does a direct-acting relief valve work, and what is pressure override?

A spring holds a poppet on its seat. When inlet pressure times seat area beats the spring, the poppet lifts and oil goes to tank. It must lift further to pass more flow, so pressure keeps rising: the override, (full-flow pressure − cracking pressure) / cracking pressure. The escaping jet also pushes the poppet shut. THE PRESS's relief is set to 210 bar with the small pump's 10.67 L/min over it; a 6 mm poppet on a 100 N/mm spring then cracks at 198.3 bar (5.9 % override), below the 198.94 bar full-force pressure, so it bleeds 0.62 L/min before the press reaches full force.

A relief valve: cracking pressure, pressure override against flow, direct-acting against pilot-operated, and the heat it makes: interactive loads as you scroll

Why is a pilot-operated relief valve flatter?

A small pilot poppet sets the pressure in a chamber above a big main poppet, fed through a tiny orifice. The pilot passes only about 0.3 L/min, so its override is small. The main poppet has a light spring and opens as soon as the orifice drop beats it. Set to 210 bar at 10.67 L/min, the model cracks at 205.1 bar (2.4 % override) and reads 216 bar at 50 L/min, where the direct valve reads 256 bar. Rexroth's DBD data sheet says the same in words: the further the setting is below the spring's rating, the more the pressure rises with flow.

Where does the relief valve's power go, and what does back pressure do?

All of it becomes heat: no work is done on oil that drops 210 bar through a valve. In THE PRESS's 2 s dwell the small pump's flow goes over the relief while the big pump idles: 4.77 kW, 9.54 kJ a cycle, 19 % of the 50.39 kJ the motor puts in. At 202 strokes an hour that is 1.93 MJ, enough to warm the tank's 160 L of oil (chapter 4) by 7.7 °C an hour with no cooling. Back pressure in the tank port adds 1:1 to the setting of a direct-acting relief (Rexroth DBD: 200 bar spring + 50 bar in T = 250 bar).

How do pressure-reducing and sequence valves differ from a relief valve?

A relief valve is normally closed and senses its inlet. A pressure-reducing valve is normally open and senses its outlet: it throttles to hold a lower pressure in one branch, such as a 63 mm clamp cylinder kept at 50 bar (15.6 kN) while the main system runs at 210 bar (65.5 kN would crush the part). A sequence valve is normally closed and senses its inlet, but its outlet feeds a working line, so it needs an external drain: it sends oil to a second actuator only after the first has built up pressure. A pressure switch closes a contact at a set pressure instead.

What do counterbalance and unloading valves do on THE PRESS?

The platen's 1,500 kg pulls the rod down and makes 12 bar under the rod side. A counterbalance valve (normally closed, sensing that line, with a check for free upward flow) set about 30 % above it, 15.6 bar, stops the platen running away; with the weight helping, the cap side then needs only 2.2 bar to push it down. The unloading valve senses the system line remotely and, above 40 bar, dumps the big pump to tank at 3 bar: 0.26 kW instead of the 18 kW it would burn over the relief at 210 bar.

Predict, then check

THE PRESS needs 198.9 bar for full force. A direct-acting relief set to 210 bar at the pump flow cracks at 198.3 bar. What happens near the end of pressing?

Worked examples

Cracking pressure and override of a direct-acting relief · Poppet seat 6 mm, cone half-angle 45°, spring 100 N/mm, Cd 0.62, oil 835.6 kg/m³. Set to 210 bar with 10.67 L/min passing.
  1. Seat area As = π × 6² / 4 = 28.27 mm².
  2. Jet speed: v = √(2p/ρ) = √(2 × 210 × 10⁵ / 835.6) = 224.2 m/s; opening needed A = Q / (Cd v) = 1.28 mm².
  3. Lift: x = A / (π ds sin α) = 0.096 mm.
  4. Extra spring force k x = 9.6 N; flow force 2 Cd A p cos α = 23.56 N.
  5. Pressure needed for both: 33.16 / 28.27 mm² = 11.73 bar, so the valve cracks at 198.27 bar.
  6. Override = (210 − 198.27) / 198.27 = 5.92 %; without the flow force it would be only 1.64 %.

Answer: Cracks at 198.3 bar, 5.9 % override: the jet's flow force makes most of it.

Heat from the dwell over the relief · THE PRESS's dwell: 2 s at 210 bar, small pump over the relief, big pump unloaded at 3 bar; cycle 17.81 s; the tank's 160 L of oil (chapter 4: 3 × 53.36 L/min), cp 1,880 J/(kg·K), no cooler.
  1. Small pump: 10.672 L/min × 210 bar / (0.92 × 0.90) = 4.511 kW; big pump at 3 bar: 0.258 kW.
  2. Heat rate: 4.769 kW; per dwell 9.54 kJ.
  3. Per hour: 9.54 × 3,600 / 17.81 = 1,928 kJ = 1.93 MJ.
  4. Oil mass 133.8 kg; ΔT = 1.93 × 10⁶ / (133.8 × 1,880) = 7.7 °C an hour.

Answer: 4.77 kW during dwell, 7.7 °C an hour from the dwell alone: unload the pump or use a pressure-compensated pump (chapter 8).

Setting the counterbalance valve · Platen 1,500 kg on a 160/100 mm cylinder, rod down. Counterbalance set 30 % above the holding pressure (assumed margin).
  1. Annulus area A2 = π (0.160² − 0.100²) / 4 = 0.012252 m²; weight 14,710 N.
  2. Holding pressure: 14,710 / 0.012252 = 1.201 MPa = 12.01 bar.
  3. Setting: 1.3 × 12.01 = 15.61 bar.
  4. Cap pressure to drive down against it: force balance p_cap A1 + W = p_cb A2, so p_cap = (15.61 bar × A2 − 14,710 N) / A1 = (19,123 − 14,710) / 0.020106 = 2.19 bar.
  5. The weight does most of the pushing: the counterbalance only makes the pump add the 30 % margin, so the platen can never fall faster than the pump fills the cap.

Answer: Set it to about 15.6 bar; the cap then needs only 2.2 bar on the way down (the rest of the 20 bar approach pressure is friction and line losses).

Chapter 15

Flow control valves: orifice flow, needle valves, pressure and temperature compensation

Which syllabus covers thisAU ME3492 Unit II (flow control valves)VTU BME702 Module 3 (compensated and non-compensated flow control valves)SPPU 302054 (flow control valves)MU not in syllabusKTU MET424 Module 4 (flow control valves)

How much oil goes through an orifice, and what Cd does this book use?

Bernoulli gives the jet speed √(2Δp/ρ); the jet narrows just past a sharp edge, so the flow is Cd A times that. This book uses Cd = 0.62 for sharp edges in turbulent flow. The US Bureau of Reclamation gives a contraction coefficient of about 0.61 for a sharp-edged slot, and the ideal-flow value π/(π + 2) = 0.611 is 1.5 % below 0.62. Flow grows with the square root of Δp: four times the drop, twice the flow. Moog rates its servo valves by the same square-root law. At low Reynolds number Cd falls; this book ignores that.

Why does a plain needle valve give a speed that changes with load?

The needle sets the area, but the flow also depends on the drop across it, and the load takes its share of the pump pressure. On the drilling feed (63/36 mm cylinder, relief 100 bar, 1 mm² opening, original case) the feed runs at 30.8 mm/s with no thrust, 25.4 mm/s at 10 kN (−17.6 %) and 13.7 mm/s at 25 kN (−56 %). When the drill breaks through and the thrust vanishes, the feed jumps forward. A needle valve is fine where the load is steady.

Flow control: orifice flow against pressure drop, and cylinder speed under a changing load with and without pressure compensation: interactive loads as you scroll

How does a pressure-compensated flow control valve hold the speed?

A spring-loaded compensator spool (a hydrostat) sits in series with the metering orifice and throttles whatever pressure is spare, so the orifice always sees about the same drop. With a 5 bar metering drop the feed runs at 7.12 mm/s with no thrust and 7.11 mm/s at 10 kN (−0.1 %). It needs a minimum drop to work: 6.25 bar for this opening, so above 29.2 kN it drops out (5.34 mm/s at 30 kN). Rexroth's 2FRM quotes a minimum of 6-14 bar and ±2 % of its maximum flow up to 350 bar.

Why do temperature-compensated valves meter through a sharp edge?

Flow through a long, narrow passage is laminar and set by viscosity: Q ∝ Δp/µ. Flow through a sharp edge is turbulent and set by density only. THE OIL's viscosity falls 8.6 times from 20 to 70 °C, but its density only 3.5 %. On the compensated feed a 100 mm capillary gives 1.72 mm/s at 20 °C and 14.6 mm/s at 70 °C; a sharp edge gives 7.04 and 7.16 mm/s (1.7 %). That is why the 2FRM calls itself pressure and thermally stable.

Where does a flow control valve go in the circuit, and what is a bypass flow control?

In the line in (meter-in), the line out (meter-out) or a branch to tank (bleed-off); chapter 18 compares them. A restrictor-type valve wastes the spare pump flow over the relief: on the feed at 10 kN the cylinder takes 71 W of the pump's 1,333 W (5.3 %). A bypass (3-way) compensated valve returns the spare flow to tank just above load pressure (2 bar margin, assumed), about 39 bar, so the pump uses 526 W (13.5 %). A flow divider splits one flow into two fixed shares for two actuators.

Predict, then check

The compensated feed runs at 7.11 mm/s with THE OIL at 50 °C and a sharp-edged metering orifice. The oil warms to 70 °C. The feed speed:

Worked examples

Feed speed through a needle valve · Drilling feed: cylinder bore 63 mm, meter-in needle valve 1 mm², Cd 0.62, supply at the 100 bar relief, thrust 10 kN, oil 835.6 kg/m³.
  1. Cap area A1 = π × 0.063² / 4 = 0.0031172 m².
  2. Load pressure: 10,000 / 0.0031172 = 32.08 bar; drop across the valve 100 − 32.08 = 67.92 bar.
  3. Flow: Q = 0.62 × 1 × 10⁻⁶ × √(2 × 67.92 × 10⁵ / 835.6) = 7.9050e-05 m³/s = 4.743 L/min.
  4. Speed: Q / A1 = 25.36 mm/s; with no thrust (100 bar drop) 30.77 mm/s.

Answer: 25.4 mm/s at 10 kN, 17.6 % slower than with no load.

Range of a pressure-compensated valve · Compensator holds 5 bar across a 1 mm² sharp orifice (Cd 0.62); its own fully open area is 2 mm². Same feed and relief.
  1. Flow at 5 bar: Q = 0.62 × 1 × 10⁻⁶ × √(2 × 5 × 10⁵ / 835.6) = 1.2869 L/min; speed 6.88 mm/s.
  2. Fully open, the compensator is an orifice of 2 mm² in series: the valve then needs 5 × (1 + (1/2)²) = 6.25 bar in total.
  3. Largest thrust that keeps control: (100 − 6.25) × 10⁵ × 0.0031172 = 29,224 N = 29.22 kN.
  4. Above that the speed falls, 5.34 mm/s at 30 kN.

Answer: 6.88 mm/s held up to 29.2 kN; the minimum valve drop of 6.25 bar sits inside the 2FRM's 6-14 bar.

A laminar restrictor and the oil temperature · A 100 mm capillary sized to pass the same 1.2867 L/min as the 1 mm² orifice at 5 bar and 50 °C. THE OIL at 20, 50 and 70 °C.
  1. Hagen-Poiseuille: d⁴ = 128 µ L Q / (π Δp) with µ50 = 25.46 mPa·s, so d = 1.452 mm.
  2. Check laminar: Re = 4Q / (π d ν) = 617, below 2,300.
  3. Q ∝ 1/µ: µ20 = 109.7, µ70 = 12.69 mPa·s, so Q20 = 0.299 and Q70 = 2.581 L/min at 5 bar.
  4. A sharp orifice changes only by √(ρ20/ρ70) = 1.0173 over the same range.

Answer: The capillary's flow changes 8.6 times from 20 to 70 °C, the sharp orifice's by 1.7 %.

Chapter 16

Servo and proportional valves: electro-hydraulic position control and hydraulic stiffness

Which syllabus covers thisAU ME3492 Unit III (electro-hydraulic circuits, servo and proportional valves, servo systems)VTU not in syllabusSPPU 302054 (digitalisation of fluid power)MU not in syllabusKTU MET424 Module 4 (servo valves), MET397 Module 3

What is the difference between a servo valve and a proportional valve?

Both open in proportion to an electric signal. A two-stage servo valve has a torque motor moving a flapper between two nozzles; the pressure difference moves the main spool and a feedback wire centres the flapper. Moog's G761 makes a full step in 5 ms with hysteresis of at most 3 % and threshold 0.5 %, zero-lapped. A proportional valve pushes the spool with a proportional solenoid. Without spool feedback HYDAC's PWK06J takes 240 ms, with up to 10 % hysteresis and 25 % overlap; with an electrical position loop Rexroth's 4WRE quotes hysteresis of 0.1 %.

How much flow does a servo valve give, and how fast can the cylinder go?

Valves are rated at a stated drop: the G761-19 passes 19 L/min at 35 bar per land, 70 bar across the valve. Other drops follow the orifice law Q = QN √(Δp/ΔpN). On a 210 bar supply with no load the two lands share the whole 210 bar: Q = 19 √(210/70) = 32.91 L/min, driving the 63/40 mm double-rod cylinder at 0.295 m/s. A 5 kN load uses 26.9 bar, leaving 30.73 L/min. Size the valve so the needed speed is reached with about a third of the supply used by the load.

What is the hydraulic natural frequency and why does it limit a servo?

Oil is a spring. Trapped in both chambers of a cylinder at mid stroke it gives k = 4βA²/Vt. On the servo axis (area 1,861 mm², 672 cm³ of oil and line, β 1.473 GPa with 0.5 % free air) that is 30.4 N/µm. With 400 kg it rings at 275 rad/s = 43.8 Hz. Long hoses, air and a heavy load lower it; short rigid pipes and a big piston raise it. No position loop can be much faster than this oil spring.

How high can the loop gain go, and how stiff is the axis against a load?

The controller turns position error into valve opening; the loop gain Kv (1/s) is cylinder speed per metre of error. With an ideal valve the loop is third order and Routh's test gives Kv below 2ζωh: 110 /s at ζ = 0.2 (assumed). At Kv = 40 /s the 5 mm step settles in about 88 ms. A 5 kN load leaves an error of 0.45 mm, a static stiffness of 11 N/µm, because some flow leaks past the valve to hold the load pressure. Double the mass and the limit falls to 78 /s.

Electro-hydraulic position control: valve flow gain, the oil spring's natural frequency, loop gain and the step response: interactive loads as you scroll

What does a slow proportional valve do to a position loop, and what was the tracer valve?

The 240 ms valve adds a slow lag. On paper it even raises the Routh limit, to 567 /s, but the loop becomes slow and springy: at Kv = 40 /s the step overshoots 43 % and takes 626 ms; at 10 /s it overshoots 13 % and takes 523 ms, and its overlap and hysteresis leave a dead band. Such valves suit speed and force control and slow positioning. The mechanical servo came first: in a copy lathe's tracer valve the stylus moves the spool and the valve body moves with the cylinder, so it stops when it has copied the template.

Predict, then check

On the servo axis the moving mass doubles from 400 to 800 kg, with the same damping ratio. The highest stable loop gain:

Worked examples

Natural frequency of the servo axis · Double-rod cylinder 63/40 mm, 200 mm stroke, 0.15 L of line each side, THE OIL (1.5 GPa) with 0.5 % free air at 105 bar mean pressure (air at n = 1.4), mass 400 kg.
  1. Area: A = π (0.063² − 0.040²) / 4 = 0.0018606 m².
  2. Oil volume: Vt = A × 0.2 + 2 × 0.15 × 10⁻³ = 672.1 cm³.
  3. Air at 105 bar shrinks to 0.018 % of the volume; 1/β = (1 − x)/1.5 GPa + x/(1.4 p) gives β = 1.4733 GPa.
  4. Oil spring: k = 4βA²/Vt = 30.35 × 10⁶ N/m = 30.4 N/µm.
  5. ωh = √(k/m) = √(30,353,148 / 400) = 275.5 rad/s; f = ωh/2π = 43.8 Hz.

Answer: ωh = 275 rad/s (43.8 Hz) at 400 kg.

Servo valve flow and cylinder speed · Moog G761, rated 19 L/min at 35 bar per land (70 bar total). Supply 210 bar, tank 0. Cylinder area 1,860.6 mm². Load 5 kN.
  1. No load: the valve drop is 210 bar: Q = 19 × √(210/70) = 32.91 L/min.
  2. Speed: 32.91 / 60,000 / 0.0018606 = 0.2948 m/s.
  3. With 5 kN: load pressure 5,000 / 0.0018606 = 26.87 bar; valve drop 183.13 bar.
  4. Q = 19 × √(183.13/70) = 30.73 L/min; speed 0.2753 m/s.

Answer: 32.9 L/min and 0.295 m/s unloaded; 30.7 L/min with 5 kN.

Loop gain limit and position error · The same axis, ωh = 275.5 rad/s, damping ratio 0.2 (assumed), ideal valve, Kv = 40 /s, load force 5 kN.
  1. Characteristic equation s³/ωh² + 2ζ s²/ωh + s + Kv = 0; Routh: Kv < 2ζωh = 2 × 0.2 × 275.5 = 110.2 /s.
  2. Gain margin at Kv = 40: 110.2 / 40 = 2.75.
  3. Leakage coefficient that gives ζ = 0.2: Kce = ζ A √(Vt/(β m)) = 1.257e-11 m³/(s·Pa).
  4. Steady error: e = Kce F / (A² Kv) = 1.257e-11 × 5,000 / (3.4619e-06 × 40) = 0.454 mm.
  5. Static stiffness F/e = 11 N/µm.

Answer: Kv must stay below 110 /s; at 40 /s a 5 kN load costs 0.45 mm of position.

Chapter 17

Basic hydraulic circuits: cylinder control, regenerative and pump-unloading circuits

Which syllabus covers thisAU ME3492 Unit III (regenerative, pump unloading and double-pump circuits)VTU BME702 Module 3 (cylinder control, regenerative, unloading, double pump)SPPU 302054 (regenerative circuit)MU not in syllabusKTU MET424 Module 5 (regenerative, pump-unloading, double-pump)

How does a valve make a cylinder go out, come back and stop?

A single-acting cylinder needs a 3/2 valve: one position sends oil in, the other lets a spring or the load push it back to tank. A double-acting cylinder needs a 4/3 valve: P to the cap and rod side to tank to extend, the reverse to retract, and a centre position to stop. On THE PRESS's 53.36 L/min the platen extends at 44.23 mm/s and returns faster, 72.59 mm/s, because the annulus is smaller. At 210 bar it pushes 422.2 kN but pulls only 257.3 kN.

What is a regenerative circuit and what does it trade?

Pipe the rod-side port to the cap side while extending. Both chambers see the same pressure, so the net area is only the rod area, and the oil pushed out of the annulus joins the pump flow instead of going to tank. On THE PRESS's 100 mm rod that oil adds 83.2 L/min to the pumps' 53.36: the platen extends at 113.2 mm/s, 2.56 times faster, but the most it can push at 210 bar falls from 422.2 to 164.9 kN. Speed for force, nothing free.

The regenerative circuit: extension speed and force with and without regeneration, against the rod size: interactive loads as you scroll

Why do designers like a 2:1 area-ratio cylinder for regeneration?

If the rod area is half the bore area, the annulus also equals half the bore area. Then regenerative extension (Q/Ar) and retraction (Q/A2) run at the same speed. For a 160 mm bore that rod is 160/√2 = 113.1 mm, which is not an ISO 3320 size: 110 mm gives an area ratio of 1.9 and 125 mm gives 2.57. At 53.36 L/min the ideal rod would give 88.5 mm/s both ways.

How does a regenerative circuit still give full force at the end of the stroke?

A pressure switch or a sequence valve watches the pump pressure. While the load is light the circuit regenerates; when the pressure reaches the setting, the rod side is switched to tank and the full bore area pushes. In the interactive's default, a 150 bar switch on THE PRESS changes over at a load of 117.8 kN; a 60 kN load needs only 76.4 bar in regeneration, so it stays fast.

What do pump-unloading and high-low circuits save?

A fixed pump keeps delivering when the cylinder stops. Over the relief at 210 bar, THE PRESS's small pump takes 4.51 kW of shaft power, all of it heat; dumped to tank at 3 bar through an unloading valve it takes 0.064 kW. The high-low circuit uses this: both pumps give the fast approach, then the big pump unloads and a check valve isolates it while the small one builds force. One pump big enough for 53.36 L/min at 210 bar would need 22.6 kW; THE PRESS's peak is 4.77 kW.

How do you lock a cylinder so the load cannot drift?

Put pilot-operated check valves in both cylinder lines. A poppet check seals almost without leakage, unlike a spool valve's clearance, so the cylinder holds position when the directional valve centres. To move, the pressure in the opposite line opens the check by its pilot. THE PRESS's 1,500 kg platen hangs on the annulus at 12 bar; the check holds that pressure, and a spool valve alone would let the platen creep down.

Predict, then check

THE PRESS (bore 160 mm, rod 100 mm) extends at 44.2 mm/s on 53.36 L/min. Switch it to regenerative extension with the same pumps. The speed becomes about:

Worked examples

Regenerative extension of a 100/70 cylinder · Cylinder bore 100 mm, rod 70 mm; pump 40 L/min; relief 160 bar. Compare normal and regenerative extension and the retraction.
  1. A1 = π × 0.1²/4 = 78.54 cm²; Ar = π × 0.07²/4 = 38.48 cm²; A2 = A1 − Ar = 40.06 cm².
  2. Normal: v = Q/A1 = (40/60,000)/0.007854 = 84.9 mm/s; F max = 160 bar × A1 = 125.7 kN.
  3. Regenerative: v = Q/Ar = 173.2 mm/s; the annulus returns 41.63 L/min, so 81.63 L/min enters the cap.
  4. F max regenerative = 160 bar × Ar = 61.6 kN. Retraction: v = Q/A2 = 166.4 mm/s.

Answer: Regeneration doubles the speed to 173 mm/s (2.04 ×) and halves the force to 61.6 kN.

Choosing the rod for equal speeds, and the changeover load · Bore 125 mm on a 35 L/min pump, regenerative extension; a pressure switch at 120 bar changes it to normal.
  1. Equal regen-extend and retract speeds need Ar = A1/2: rod = 125/√2 = 88.4 mm. The nearest ISO 3320 rod is 90 mm.
  2. With 90 mm: area ratio A1/A2 = 2.076; regen extend 91.7 mm/s, retract 98.7 mm/s.
  3. Changeover load = 120 bar × Ar = 120 × 10⁵ × 0.006362 = 76.3 kN.
  4. Above that load the cylinder extends on the full bore at 47.5 mm/s.

Answer: Use a 90 mm rod; the switch changes over at about 76 kN.

What unloading the small pump in the dwell saves · THE PRESS dwells 2 s per cycle with the small pump (8 cm³/rev, 1,450 rpm, ηm 0.90) over the 210 bar relief. Alternative: a pilot-operated check holds the pressure and the pump unloads at 3 bar. 202 strokes an hour, 16 hours a day, 300 days, ₹8/kWh.
  1. Shaft power over the relief = 8 × 10⁻⁶ × 210 × 10⁵/(2π × 0.9) × 2π × 1,450/60 = 4.511 kW.
  2. Unloaded at 3 bar: 0.0644 kW. Saving = 4.447 kW × 2 s = 8.89 kJ per cycle.
  3. Per day: 8.89 × 202.1 × 16/3,600 = 7.99 kWh.
  4. Per year: 7.99 × 300 × ₹8 = ₹19,173.

Answer: About 8 kWh a day, ₹19,173 a year, and that much less heat in the oil.

Chapter 18

Speed control circuits: meter-in, meter-out, bleed-off and counterbalance valves

Which syllabus covers thisAU ME3492 Unit III (speed control and deceleration circuits)VTU BME702 Module 3 (meter-in, meter-out, counterbalance valve)SPPU 302054 (meter-in and meter-out circuits)MU not in syllabusKTU MET424 Module 5 (speed control, bleed-off, counterbalance)

What is meter-in control, and where does it fail?

A needle valve in the line into the cap end sets the flow; the rest of the pump's flow goes over the relief, so the pump always works at the relief setting. In the interactive's drilling feed (80/50 mm cylinder, 10.67 L/min, 0.1 mm² opening, 20 kN thrust) the cap needs 39.8 bar and the drill feeds at 2.49 mm/s, using 1.3 % of the pump power. With an overrunning load the cap would need suction: the oil cavitates and the load runs away.

Why does meter-out control hold a load, and what pressure does it make?

The needle valve throttles the oil leaving the rod side, so the cylinder is squeezed between pump pressure and a back pressure, and an overrunning load cannot run ahead. The rod end pays for it: with the cap at 210 bar, the drill's annulus sits at 279 bar. Lowering THE PRESS's 1,500 kg platen the same way gives 357 bar, above the 250 bar nominal rating of a CDL2-type cylinder and near its 375 bar test pressure. Check the rod-end pressure whenever you meter out.

Meter-in, meter-out and bleed-off: pressures in both chambers, speed, efficiency and what an overrunning load does: interactive loads as you scroll

What does a bleed-off circuit do better and worse?

The needle valve sits in a tee from the pump line to tank and bleeds part of the flow away; the rest moves the cylinder. The pump only rises to the load pressure, so little power is wasted: the drilling feed runs at 34.2 mm/s with 96.6 % efficiency. But the bleed flow depends on that load pressure, so the speed swings with the load, an unloaded cylinder gets the full pump flow, and an overrunning load is not held at all.

What does a counterbalance valve do on a vertical press?

It is a pressure valve in the rod-side line that stays shut until the annulus pressure exceeds its setting, usually about 1.3 times the pressure the load makes on its own (typical practice, assumed here). THE PRESS's platen makes 12 bar on the annulus, so the valve is set near 15.6 bar. The platen cannot fall, and the pump needs only 2.2 bar on the cap to drive it down. A built-in check lets oil flow freely the other way for the return stroke.

Where does the power go in a throttled circuit?

Pump power p × Q equals the useful power F × v plus the losses in the relief, the needle valve and the counterbalance valve, and every lost kilowatt heats the oil. In the meter-out drill feed the pump delivers 3.74 kW and only 105 W drills: 3.63 kW of heat. Lowering a weight is worse: its falling energy also becomes heat. A pressure-compensated or load-sensing pump (chapter 8) cuts this waste.

Why do drilling-machine feeds use meter-out?

When the drill breaks through, the thrust drops to zero. In the steady model both circuits speed up by about the same amount (meter-in 11 %, meter-out 11 %). The difference is the jump: with meter-in, 100 mm of cap oil compressed to 40 bar springs the drill forward 0.27 mm with nothing behind it, more with hose swell. Meter-out keeps a stiff column of oil on the rod side, so the drill stays under control and does not grab.

Predict, then check

THE PRESS's 1,500 kg platen is lowered with a meter-out valve, the relief at 210 bar and no counterbalance valve. The pressure at the rod end is about:

Worked examples

Meter-out pressures and speed · A feed cylinder 63 mm bore, 40 mm rod extends against 15 kN with meter-out control. Pump 8 L/min, relief 140 bar, needle valve 0.2 mm², Cd 0.62, oil 835.6 kg/m³ (50 °C).
  1. A1 = 31.17 cm², A2 = 18.61 cm². The valve controls, so the pump sits at 140 bar: p1 = 140 bar.
  2. Rod end: p2 = (p1 A1 − F)/A2 = (140 × 10⁵ × 0.003117 − 15,000)/0.001861 = 153.9 bar.
  3. Valve flow Q = 0.62 × 0.2 × 10⁻⁶ × √(2 × 153.9 × 10⁵/835.6) = 1.428 L/min.
  4. Speed = Q/A2 = 12.79 mm/s; cap inflow 2.393 L/min, so 5.61 L/min goes over the relief.

Answer: p2 ≈ 154 bar, speed ≈ 12.8 mm/s, efficiency 10.3 %.

The same feed with meter-in · As above, but the 0.2 mm² valve is in the cap line and the rod side drains freely to tank.
  1. Rod side at 0 bar, so p1 = F/A1 = 15,000/0.003117 = 48.12 bar.
  2. Valve drop = 140 − 48.12 = 91.88 bar; Q = 0.62 × 0.2 × 10⁻⁶ × √(2 × 91.88 × 10⁵/835.6) = 1.103 L/min.
  3. Speed = Q/A1 = 5.9 mm/s.
  4. Pump power 140 bar × 8 L/min = 1.867 kW; useful 15 kN × 5.9 mm/s = 88.5 W; heat 1.778 kW.

Answer: Speed ≈ 5.9 mm/s at 48 bar in the cap; 4.7 % efficient, no rod-end intensification.

Counterbalance valve for a die · A 2,000 kg die hangs on a vertical 100/56 mm cylinder (rod down). A counterbalance valve is set at 1.3 × the holding pressure; a 20 L/min pump drives the die down with no other throttling.
  1. Weight = 2,000 × 9.807 = 19,613 N; A1 = 78.54 cm², A2 = 53.91 cm².
  2. Holding pressure = W/A2 = 36.38 bar; CBV setting = 1.3 × 36.38 = 47.3 bar.
  3. Down speed = 20 L/min/A1 = 42.4 mm/s; cap pressure p1 = (pcb A2 − W)/A1 = 7.49 bar.
  4. Heat in the CBV = 47.3 bar × 13.73 L/min = 1.082 kW = pump 0.25 kW + falling die 0.832 kW.

Answer: Set the CBV near 47 bar; the pump needs only 7.5 bar, and 1.08 kW is turned to heat.

Chapter 19

Accumulators and intensifiers: gas law sizing, accumulator circuits and safety

Which syllabus covers thisAU ME3492 Unit III (accumulators, intensifiers, air-over-oil)VTU BME702 Module 2 (accumulators), Module 3 (accumulator circuits, force multiplication)SPPU not in syllabusMU not in syllabusKTU MET424 Module 2 (intensifiers, accumulators)

What kinds of accumulator are there?

An accumulator stores oil under pressure. A weight-loaded one gives constant pressure but is huge: 150 bar on a 200 mm ram needs 48 tonnes. Spring-loaded ones are small and low pressure. Industry uses gas-charged ones, with nitrogen separated from the oil by a rubber bladder, a piston or a diaphragm. HYDAC's catalogue limits the maximum to precharge pressure ratio to 4:1 for bladders, typically 8:1 for diaphragms, and none for pistons, which suit large volumes.

How do you size a gas-charged accumulator?

The nitrogen obeys p V^n = constant in absolute pressure: n = 1 for slow charging and discharging (isothermal), n = 1.4 for fast ones (adiabatic). Oil comes out as the gas expands from V2 at the maximum working pressure p2 to V1 at the minimum p1. To return THE PRESS's platen 360 mm with the pump off takes 4.41 L. With p0 45, p1 50, p2 150 bar that needs a gas volume of 7.38 L isothermal or 8.8 L adiabatic: a size 10 bladder accumulator (9.28 L of gas).

Sizing a gas-charged accumulator: precharge, working pressures, isothermal against adiabatic, and the intensifier: interactive loads as you scroll

How high should the precharge be?

HYDAC's rule for energy storage is p0 = 0.9 × p1, so a little oil always stays in the shell and the bladder never slams into the outlet valve. Too low wastes volume; above p1 the accumulator gives no oil until the pressure falls below p0. Precharge changes with absolute temperature: 45 bar set at 20 °C becomes 49.7 bar at 50 °C. Check it with a charging kit at the temperature you set it, and real nitrogen above about 200 bar needs the maker's correction factors.

What do accumulator circuits do in a press?

They supply oil when the pump cannot: an emergency return, holding pressure while the pump unloads, leak make-up and shock absorption. They also let a smaller pump do a peak job. THE PRESS's big pump runs only in the rapid strokes; a 29.8 L/min pump running all cycle plus 2.67 L stored while pressing replaces the 42.69 L/min one, 30 % less flow. The catch: it now works against 40-70 bar all cycle, so it saves pump size, not energy.

What is an intensifier and when is air-over-oil used?

An intensifier is a large piston driving a small one on the same rod: p_out = p_in × A_large/A_small, while the flow drops by the same ratio. An air-over-oil booster with a 200 mm air piston and a 25:1 ratio turns THE FIXTURE's 6 bar shop air into 150 bar of oil, but gives only 126 cm³ of oil per 100 mm stroke and uses 21.7 L of free air. It suits short, high-force strokes: riveting, clinching, a small press.

Why is an accumulator dangerous during maintenance?

It keeps its energy after the pump stops. The size 10 accumulator charged to 150 bar can push out about 46 kJ by the time it falls to 50 bar, enough to lift THE PRESS's platen 3.1 m. Fit a safety block with a shut-off, a relief valve and a bleed valve; discharge the oil to tank before opening any line; and charge only nitrogen, never air or oxygen. Accumulators are pressure equipment and local regulations apply.

Predict, then check

The same accumulator works between the same p1 and p2 with the same precharge. Discharged fast (adiabatic) instead of slowly (isothermal), it delivers:

Worked examples

Sizing an accumulator for a clamp circuit · A clamp circuit needs 1.5 L of oil between 90 and 160 bar. Precharge by HYDAC's rule; compare isothermal and adiabatic sizing and pick a HYDAC SB330 bladder size.
  1. p0 = 0.9 × 90 = 81 bar. Absolute (gauge + 1.01325): p0 82.01325, p1 91.01325, p2 161.01325 bar.
  2. Isothermal: V0 = ΔV/(p0/p1 − p0/p2) = 1.5/(0.9011 − 0.5094) = 3.83 L.
  3. Adiabatic: V0 = ΔV/((p0/p1)^(1/1.4) − (p0/p2)^(1/1.4)) = 4.83 L.
  4. p2/p0 = 1.98, inside the 4:1 bladder limit. Smallest SB330 size with ≥ 4.83 L of gas: size 6 (5.57 L).

Answer: V0 ≈ 4.8 L for a fast discharge: use a size 6 bladder accumulator precharged to 81 bar.

Oil delivered by a given accumulator · A size 20 bladder accumulator (1,125 in³ of gas) precharged to 60 bar works between 180 and 100 bar with fast discharge.
  1. V0 = 1,125 × 0.016387 = 18.44 L.
  2. At 180 bar: V2 = 18.44 × (61.01325/181.01325)^(1/1.4) = 8.48 L (absolute = gauge + 1.01325).
  3. At 100 bar: V1 = 18.44 × (61.01325/101.01325)^(1/1.4) = 12.86 L.
  4. Usable oil = V1 − V2 = 4.38 L (isothermal would give 4.92 L).

Answer: About 4.4 L of oil per discharge.

Hydraulic intensifier · An intensifier has a 100 mm low-pressure piston and a 40 mm high-pressure ram on one rod. It is fed at 60 bar with 12 L/min. Ignore friction and leakage.
  1. Area ratio = (100/40)² = 6.25.
  2. Force balance p_in A_in = p_out A_out: p_out = 60 × 6.25 = 375 bar.
  3. Both pistons move together at 12 L/min/A_in = 25.5 mm/s, so the ram delivers 25.5 mm/s × A_out = 1.92 L/min.
  4. Power in = 60 bar × 12 L/min = power out = 375 bar × 1.92 L/min = 1.2 kW: pressure is traded for flow, not created.

Answer: 375 bar at 1.92 L/min.

Chapter 20

Industrial circuits: the high-low press, sequencing, synchronising, fail-safe circuits and system sizing

Which syllabus covers thisAU ME3492 Unit III (sequence, synchronisation, fail-safe, system sizing), Unit V (press circuits)VTU BME702 Module 3 (sequencing and synchronizing circuits)SPPU 302054 (design of a hydraulic system)MU MESBL601 Group C (electro-hydraulic sequence)KTU MET424 Module 5 (sequencing, synchronizing, fail-safe)

What happens in one cycle of THE PRESS?

Rapid approach on both pumps, 330 mm in 7.46 s at 20 bar; pressing on the small pump while the big one unloads, 30 mm in 3.39 s as the pressure climbs to 198.94 bar; a 2 s dwell with the small pump over the relief; rapid return in 4.96 s. That is 17.81 s, 202 strokes an hour. The shaft power swings from 0.69 to 4.77 kW; its RMS, 2.98 kW, is what heats the motor. A 4 kW motor (assumed size) carries that, and must ride the 4.77 kW dwell peak, 19 % over its rating for 2 s.

The book's 400 kN press through one cycle: high-low pumps, unloading, dwell, pressures, flows, power and the oil's heat load: interactive loads as you scroll

In what order do you size a hydraulic system?

Force, then bore, flow, pump, motor, tank and cooler. 400 kN at a 210 bar relief needs at least 155.7 mm, so the ISO 160 mm bore, which needs 198.94 bar. The approach speed sets the total flow (53.36 L/min for 44.2 mm/s) and the pressing speed sets the small pump. The motor follows from the cycle's RMS and peak power. The tank is 3 to 5 times the pump flow per minute (Power & Motion), 160 L at 3 times; the heat balance decides the cooler.

How much cooling does THE PRESS need?

Of 50.39 kJ per cycle at the shaft, only 5.4 kJ deforms the workpiece. The rest heats the oil, including the approach and return energy lost to friction and the counterbalance valve: 2.53 kW on average (the losses before the cylinder alone are 0.97 kW). The 2 s dwell over the relief makes 21 % of it. A 160 L tank 10 K above a 40 °C shop sheds about 0.24 kW (assumed k), so a cooler of about 2.3 kW is needed.

How do you make one cylinder wait for another?

A sequence valve opens the line to the second cylinder only when the first has built a set pressure, so a clamp grips before the press stroke starts. A 63 mm clamp giving 9 kN needs 28.9 bar; set the sequence valve some 15-20 bar higher (typical) so the press waits for a firm grip. Limit switches with solenoid valves do the same job by position and are easier to change; THE PRESS's unloading valve is a pressure-sequenced valve too.

How do you make two cylinders move together?

In a series circuit the rod side of the first feeds the cap of the second, so equal areas give equal speeds: a 100/56 first cylinder needs a second bore of 82.8 mm, not a standard size. The first carries both loads, (F1 + F2)/A1: 40 + 30 kN needs 89.1 bar. Flow dividers split one flow into two with some error, and a rigid mechanical link (rack and pinion, torque tube) is the most accurate.

What makes a press circuit fail-safe?

The valve and the operator must both be unable to drop the ram by mistake. A counterbalance or pilot-operated check valve mounted on the cylinder holds THE PRESS's platen (12 bar) even if a hose bursts; spring-centred valves stop the press when power fails; two-hand controls start a stroke only when both buttons are pressed together, keeping hands out of the die; and the relief valve caps every pressure. Power packs and air-over-oil units follow the same rules.

Predict, then check

THE PRESS makes 202 strokes an hour with a 2 s dwell. Cut the dwell to 1 s and keep everything else. The strokes per hour become about:

Worked examples

Sizing the pumps and motor of a 250 kN press · A 250 kN press, maximum working pressure 180 bar, approach at 100 mm/s, pressing at 10 mm/s, high-low pumps on a 1,450 rpm motor (ηv 0.92, ηm 0.90), big pump unloaded at 3 bar while pressing.
  1. Minimum bore = √(4F/(πp)) = √(4 × 250,000/(π × 180 × 10⁵)) = 133 mm: choose the ISO 140 mm bore (A1 = 153.9 cm²).
  2. Full-force pressure = 250,000/A1 = 162.4 bar.
  3. Flows: approach 92.4 L/min, pressing 9.24 L/min. Small pump = 9.24/(1,450 × 0.92) = 6.92 cm³/rev; big pump 62.3 cm³/rev.
  4. Shaft power at the end of pressing = 3.52 kW (small pump at 162 bar, big pump at 3 bar).

Answer: Bore 140 mm, pumps about 6.9 + 62 cm³/rev; the pressing end needs 3.5 kW.

RMS power of a duty cycle · A machine's shaft power: 6 s at 3 kW, a 3 s ramp from 1 to 5 kW, 2 s at 5.5 kW, 4 s at 4 kW, repeating.
  1. Cycle T = 15 s. Energy = 6 × 3 + 3 × (1 + 5)/2 + 2 × 5.5 + 4 × 4 = 54 kJ; mean 3.6 kW.
  2. ∫P² dt: constant parts 6 × 9 + 2 × 30.25 + 4 × 16 = 178.5; the ramp gives 3 × (1 + 5 + 25)/3 = 31.
  3. RMS = √((178.5 + 31)/15) = 3.737 kW.
  4. The motor must carry the RMS continuously and the 5.5 kW peak for 2 s.

Answer: RMS 3.74 kW against a mean of 3.6 kW: rate the motor by the RMS, check the peak.

The cooler for THE PRESS · Heat to the oil 2.526 kW (from the cycle). THE TANK (chapter 4): 3 × 53.36 L/min = 160.1 L plus 10 % air, a 2 : 1 : 1 box on legs losing heat from all six faces at k = 12 W/(m²·K) (assumed), oil 50 °C, shop 40 °C. Oil 835.6 kg/m³, cp 1.88 kJ/(kg·K).
  1. Box volume 176.1 L: height H = (0.1761/2)^(1/3) = 0.445 m; six faces 2H × H × H = 10 H² = 1.979 m².
  2. Tank loss = 12 × 1.979 × 10 = 237.5 W.
  3. Cooler = 2,526.3 − 237.5 = 2,288.8 W.
  4. Without it the oil (134 kg) would start warming at 2.289/(134 × 1.88) × 3,600 = 32.8 K an hour.

Answer: A cooler of about 2.3 kW; the tank alone cannot hold 50 °C.

Chapter 21

Compressed air: properties, compressors, air treatment, distribution and leaks

Which syllabus covers thisAU ME3492 Unit IV (properties of air, air preparation and distribution, FRL)VTU BME702 Module 4 (compressed air, compressors, dryers, FRL)SPPU 302054 (pneumatic system components)MU not in syllabusKTU MET397 Module 1 (pneumatic drives)

What is free air, and why do pneumatic catalogues quote flow in Nl/min (ANR)?

Air is a gas, so a litre means nothing until you say at what pressure and temperature. Free air is the volume the air had at the compressor intake, at atmospheric pressure. One litre at 6 bar gauge holds 6.92 litres of free air at 1.013 bar. Catalogues use the ISO 8778 reference atmosphere, ANR: 20 °C and 1.00 bar absolute. The same litre is 7.01 Nl (ANR), 1.3 % more because the reference pressure is a little lower. THE FIXTURE uses 2.7541 L of free air per cycle with its tubes, 33.05 L/min at 12 cycles a minute.

Which compressors make shop air, and how much electricity does a cubic metre cost?

Reciprocating (piston) compressors squeeze air in a cylinder, in one stage or two with an intercooler between. Oil-injected screw compressors trap air between two rotors and run smoothly at full load. Vane compressors suit small flows. BEE's table gives a two-stage piston compressor 6.48 kW per m³/min of free air at 7 bar (18.34 kW per 100 cfm). BEE's MSME guide puts screws at 4.94-8.83 kW per m³/min. The ideal isothermal minimum at 7.5 bar is only 3.59 kW per m³/min, so a real machine needs about 1.8 times the ideal. The Thermal Engineering book shows the piston compressor's p-V cycle.

Why must compressed air be cooled, dried and filtered before it reaches a valve?

Air from a compressor is hot and carries the water vapour it drew in. As it cools in the pipes the water condenses, with oil from the compressor, and washes the grease out of valves and cylinders. An aftercooler and a separator drop most of the water. A dryer then sets the pressure dew point. ISO 8573-1 names water classes by it: class 4 is +3 °C or lower, class 2 is −40 °C. BEE lists −20 °C for refrigeration dryers and −40 °C for heated desiccant dryers. At each machine a filter-regulator-lubricator (FRL) cleans the air, sets the 6 bar and, where needed, adds oil mist.

How do you measure a shop's leaks, and what do they cost?

Stop production and run the compressor on leaks alone. It loads for T seconds and unloads for t seconds. The leak share of capacity is T/(T + t), BEE's leak test. In the medium shop with 20 % of the air lost, the 4 m³/min two-stage compressor loads 34.1 s and unloads 225.9 s, 13.1 % of capacity. Those leaks waste 17,171 kWh a year, ₹1.37 lakh at ₹8/kWh. BEE's MSME guide asks for leakage within 3-10 %. Drag the leak slider and watch the off-load time shrink.

A shop's compressed air system: demand, compressor power, receiver size, the leak test and the cost of pressure and leaks: interactive loads as you scroll

How should the air reach the machines, and what does pressure cost?

A ring main feeds every drop from two sides, so the pressure stays even. BEE accepts 0.3 bar drop in the main header at the farthest point and asks for a slope of 1 inch in 10 ft, drains at most 30 m apart and branch take-offs from the top of the pipe. The receiver stores at least one minute of compressor output. Pressure costs power: BEE says 1 bar lower saves 6-10 %. In the model, 7.5 → 6.5 bar saves 5.5 % on the compressor (BEE's table) and 7.8 % with the leaks, which also shrink. The fixture still gets its 6 bar.

Predict, then check

The medium shop lowers its receiver from 7.5 to 6.5 bar. How much electricity does it save?

Worked examples

Air demand and compressor for the medium shop · 20 FIXTURE stations at 33.05 L/min each, other users 1,500 L/min, leaks 20 % of the air made, 7.5 bar, two-stage piston compressor, 4,800 h a year, ₹8/kWh.
  1. Useful demand = 20 × 33.05 + 1,500 = 2,161 L/min = 2.161 m³/min.
  2. With 20 % leaks the compressor makes 2.161/0.8 = 2.701 m³/min (0.54 m³/min of leaks).
  3. Loaded no more than 80 %: 2.701/0.8 = 3.38 m³/min, so pick a 4 m³/min compressor.
  4. Specific power at 7.5 bar (BEE Table 3.9, between 18.34 and 19.16 kW per 100 cfm) = 6.622 kW per m³/min.
  5. Power on load = 6.622 × 4 = 26.5 kW; average = 6.622 × 2.701 = 17.89 kW.
  6. Energy = 17.89 × 4,800 = 85,854 kWh a year = ₹6.87 lakh.

Answer: A 4 m³/min, 26.5 kW compressor using 85,854 kWh (₹6.87 lakh) a year; the leaks alone cost ₹1.37 lakh.

BEE leak test on a screw compressor · Production stopped. A 5 m³/min screw compressor at 7.5 bar loads for 20 s and unloads for 80 s, again and again. Specific power: BEE MSME midpoint 0.195 kW/cfm at 7 bar, scaled to 7.5 bar.
  1. Leak share = T/(T + t) = 20/(20 + 80) = 20 % of capacity.
  2. Leak flow = 5 × 0.20 = 1 m³/min of free air.
  3. Specific power at 7.5 bar = 6.886 × 1.0391 = 7.156 kW per m³/min.
  4. Power lost = 7.156 × 1 = 7.16 kW, all day.
  5. Per year = 7.16 × 4,800 = 34,347 kWh = ₹2.75 lakh.

Answer: Leaks are 20 % (BEE target 3-10 %): 1 m³/min, 7.16 kW, ₹2.75 lakh a year.

Ideal and real power to compress 4 m³/min to 7.5 bar · Free air 4 m³/min at 1.013 bar; delivery 7.5 bar gauge; air n = 1.4; perfect intercooling for two stages. Real machine: BEE's two-stage figure at 7.5 bar.
  1. Pressure ratio r = (7.5 + 1.013)/1.013 = 8.402.
  2. Isothermal: P = p1 V ln r = 101,325 × (4/60) × ln 8.402 = 14.38 kW.
  3. One stage: P = (n/(n − 1)) p1 V (r^0.2857 − 1) = 19.79 kW.
  4. Two stages, each r^0.5 = 2.899: P = 2 × 3.5 × p1 V (r^0.1429 − 1) = 16.8 kW.
  5. Real two-stage compressor: 6.622 × 4 = 26.49 kW; isothermal efficiency = 14.38/26.49 = 54.3 %.

Answer: Isothermal 14.38 kW, one stage 19.79 kW, two stages 16.8 kW; a real two-stage machine takes 26.5 kW (54 % isothermal efficiency).

Chapter 22

Pneumatic actuators and valves: force, air consumption, speed control and the quick exhaust valve

Which syllabus covers thisAU ME3492 Unit IV (pneumatic actuators, air control valves, quick exhaust valve)VTU BME702 Module 4 (actuators, control valves), Module 5 (speed control)SPPU 302054 Practical 2 (pneumatic actuators)MU not in syllabusKTU MET397 Module 2 (linear actuators)

Which pneumatic actuators are there, and what force does one give?

A single-acting cylinder pushes on air and returns on a spring. A double-acting cylinder is driven both ways. A rodless cylinder carries its load on a slide along the barrel, so a long stroke needs no extra length. Rotary actuators turn a shaft: rack-and-pinion or vane types. Force is pressure times area. THE FIXTURE's punch B, 63 mm bore and 20 mm rod, gives 1,870 N extending and 1,682 N retracting at 6 bar. Clamp A, 32 mm bore, gives 482.5 N. Seal friction takes some of that.

How big must a cylinder be for its load, and how much air does it use?

Divide the load by the theoretical force: that is the load ratio. SMC's selection guide allows up to 0.7 for static clamping, 1 for a load sliding on a guide and 0.5 for a load moved vertically or horizontally, so there is force left to accelerate it. Punch B lifting 561 N works at 0.30. Every stroke fills the swept volume and the tubes with 6 bar air that is then dumped: punch B uses 2.272 L of free air a cycle with its two 1.5 m tubes. Move the load ratio past 0.5 and the load turns red.

A pneumatic cylinder: force against load ratio, free air per cycle, valve size against speed, and supply against exhaust throttling: interactive loads as you scroll

How are pneumatic valves named, and how do you read their flow?

A 5/2 valve has five ports and two positions: supply, two cylinder ports and two exhausts; it drives a double-acting cylinder. A 3/2 valve drives a single-acting one. Spool valves slide; poppet valves lift off a seat and seal well. ISO 6358 rates flow by the sonic conductance C and the critical pressure ratio b. SMC's SY5000 has C 2.8 dm³/(s·bar) and b 0.29, so at 6 bar gauge supply it passes at most 1,178 Nl/min (ANR) once the flow is choked. SMC matches it to 63 mm bores.

Why throttle the air leaving a cylinder rather than the air entering it?

With meter-out, the needle on the exhaust side is choked, so the mass flow is C × p and the volume flow at rod pressure stays C × 1 bar. The speed is C × 1 bar / A2 whatever the load: 71.3 mm/s for punch B with the needle at C 0.2. The piston also rides between two air cushions. With meter-in, the speed falls as the load grows. An assisting load can run away, because the exhaust side is at atmosphere. At low speed both can stick-slip when breakaway friction is higher than running friction.

What do the quick exhaust valve, the time-delay valve and the memory valve do?

A quick exhaust valve sits at the cylinder port. When the main valve vents, it dumps the cylinder straight to air instead of back through the tube and valve, so the return stroke is faster. A time-delay valve fills a small reservoir through a restrictor and switches a 3/2 valve when the pressure is high enough. A 50 cm³ reservoir filled through C 0.02 from 6 bar reaches 3 bar in 1.09 s. A memory valve, a double-pilot 5/2, holds its last position after the signal goes.

Predict, then check

Punch B runs with meter-out flow controls (needle choked). Its load rises from 300 N to 600 N. What happens to the extend speed?

Worked examples

Forces and load ratios of THE FIXTURE · 6 bar gauge. Punch B 63/20 mm lifts an 800 N load vertically. Clamp A 32/12 mm holds a part with 300 N (static). SMC limits: moving 0.5, static 0.7.
  1. Punch B extend force = 0.6 N/mm² × π/4 × 63² = 1,870.3 N; retract = 0.6 × π/4 × (63² − 20²) = 1,681.9 N.
  2. Punch B load ratio = 800/1,870.3 = 0.428: within 0.5.
  3. Clamp A force = 0.6 × π/4 × 32² = 482.5 N.
  4. Clamp A load ratio = 300/482.5 = 0.622: within the static 0.7.

Answer: Punch B at 0.43 and clamp A at 0.62: both inside SMC's limits.

Air consumption and yearly cost of THE FIXTURE · Clamp A 32/12 × 25 mm and punch B 63/20 × 50 mm at 6 bar, two 4 mm × 1.5 m tubes each, 12 cycles a minute, 4,800 h a year. Air from a two-stage compressor at 7.5 bar.
  1. Clamp A: (A1 + A2) × 25 mm × 7.013/1.013 + tubes × 6/1.013 = 0.2588 + 0.2232 = 0.482 L of free air a cycle.
  2. Punch B: (A1 + A2) × 50 mm × 7.013/1.013 + tubes × 6/1.013 = 2.0489 + 0.2232 = 2.2721 L.
  3. Per cycle 2.7541 L; per minute × 12 = 33.05 L/min.
  4. Per year = 0.03305 × 60 × 4,800 = 9,518 m³.
  5. Energy = 9,518 × 6.622/60 = 1,050 kWh, × ₹8 = ₹8,403.

Answer: 33 L/min of free air, about 1,050 kWh and ₹8,403 a year for one fixture.

Valve size for a 250 mm/s punch stroke · Punch B extends at 250 mm/s on 6 bar gauge supply at 20 °C. Assume the cap pressure runs at 0.9 of the supply (absolute) while moving. Valves: SY3000 C 1.1, SY5000 C 2.8 (b 0.29).
  1. Air volume needed at 6 bar = π/4 × 0.063² × 0.25 = 0.7793 L/s.
  2. As ANR flow (1 bar abs) = 0.7793 × 7.013 = 5.466 Nl/s.
  3. ISO 6358 subsonic factor at p2/p1 = 0.9: √(1 − ((0.9 − 0.29)/(1 − 0.29))²) = 0.512.
  4. Needed C = 5.466/(7.013 × 0.512) = 1.52 dm³/(s·bar).

Answer: C ≥ 1.52: the SY3000 (1.1) is too small, the SY5000 (2.8) will do.

Chapter 23

Pneumatic circuits: logic valves, displacement-step diagrams and the cascade method for three cylinders

Which syllabus covers thisAU ME3492 Unit IV (single and multi-cylinder circuits, cascade method, pneumatic logic)VTU BME702 Module 5 (logic gates, motion diagrams, signal elimination, cascading)SPPU 302054 (pneumatic circuits)MU MESBL601 Group C (two-cylinder sequences)KTU MET397 Module 4 (sequencing, cascade method)

How do valves do logic without electricity?

A two-pressure valve passes air only when both inputs are pressurised: AND. A shuttle valve passes air from either input: OR. A normally open 3/2 valve gives NOT, since its output is on until a signal arrives. A double-pilot 5/2 valve is a memory: it stays where the last pilot left it. With these four a circuit can need two hands on two buttons (AND) or start from two places (OR). Fluidic devices once did the same with jets of air and no moving parts.

What do the displacement-step diagram and the limit valve names tell you?

Each cylinder gets a row. The line rises when it extends and falls when it retracts, one column per step. A sequence like A+ B+ C+ C− B− A− has 6 steps. Each cylinder has a roller limit valve at each end: a0 is pressed when A is home, a1 when it is out. In a plain circuit, the valve pressed at the end of one step pilots the next move, so the diagram also shows which signal is alive at every moment. The control diagram below it shows each valve's state.

What is a signal conflict, and how is it removed?

A conflict happens when a 5/2 valve gets a pilot to move while its opposite pilot is still held by a pressed limit valve, so it cannot shift. In A+ B+ C+ C− B− A−, wired directly, 4 of the 6 moves conflict (A+, B+, C−, B−). At the start, b0 is pressed and pilots A− while a0 asks for A+. Fixes: idle-return rollers that signal only one way, timers, the cascade method or a step counter. The Mechatronics book shows the two-cylinder case.

How does the cascade method split a sequence, and how many valves does it need?

Cut the sequence into groups in which no cylinder appears twice, as few as possible, letting the last group merge with the first round the cycle. Each group gets a supply line. Only one line is live at a time, and only the limit valves fed from the live line can signal, so stale signals are dead. A chain of groups − 1 cascade valves switches the lines. A+ B+ C+ | C− B− A− needs 2 groups and 1 cascade valve. A+ B+ | B− C+ | C− A− needs 3 groups and 2 cascade valves.

Three-cylinder sequences: displacement-step diagram, signal conflicts, cascade groups and the valves each limit switch feeds: interactive loads as you scroll

What else goes round the main circuit, and when is a step counter better?

Fringe circuits: an emergency stop that dumps or blocks the supply, a single-cycle or auto-cycle selector (a memory valve and a shuttle), and the start button, ANDed into the line that begins step 1. A step counter (shift register) uses one step module per step: 6 modules for a 6-step sequence. For the three-cylinder sequences here that is 16 valves against 12-13 for a cascade. The counter wins on long sequences, because each extra group adds pressure drop to a cascade.

Predict, then check

How many cascade groups does A+ B+ B− C+ C− A− need?

Worked examples

Cascade for A+ B+ C+ C− B− A− · Three double-acting cylinders on double-pilot 5/2 valves, roller limit valves at both ends, start button.
  1. Conflicts if wired directly: steps 1, 2, 4, 5 (A+, B+, C−, B−).
  2. Groups with no cylinder twice: A+ B+ C+ | C− B− A−: 2 groups, 1 cascade valve.
  3. Line GI pilots A+; a1 (fed by GI) pilots B+; b1 pilots C+; c1 switches to GII.
  4. Line GII pilots C−; c0 (fed by GII) pilots B−; b0 pilots A−; a0 AND START switches back to GI.
  5. Valves: 3 power + 6 limit + 1 cascade + 1 start + 1 AND = 12.

Answer: 2 groups, 1 cascade valve, 12 valves in all.

Cascade for A+ B+ B− C+ C− A− · Same hardware.
  1. Conflicts if wired directly: A+, B−, C−.
  2. Groups: A+ B+ | B− C+ | C− A−. The last and first groups share A, so they cannot merge: 3 groups.
  3. Cascade valves = 3 − 1 = 2.
  4. GI: A+ from the line, a1 → B+, b1 → GII. GII: B− from the line, b0 → C+, c1 → GIII. GIII: C− from the line, c0 → A−, a0 AND START → GI.
  5. Valves: 3 + 6 + 2 + 1 + 1 = 13.

Answer: 3 groups, 2 cascade valves, 13 valves.

Clamp, drill, eject: A+ B+ B− A− C+ C− · A clamps, B drills, C ejects the part. Same hardware.
  1. Conflicts if wired directly: A+, B−, A−, C−.
  2. Greedy from step 1: A+ B+ | B− A− C+ | C−: three groups.
  3. The last group (C−) shares no cylinder with the first (A+ B+), so it merges round the cycle: C− A+ B+ | B− A− C+.
  4. At rest line GI is live. C− is already done, so c0 AND START pilots A+; a1 → B+; b1 → GII; then B−, b0 → A−, a0 → C+; c1 → GI.
  5. Cascade 12 valves against a step counter's 16 (one module per step).

Answer: 2 groups and 1 cascade valve; START is ANDed with c0.

Chapter 24

Electro-pneumatics, maintenance and troubleshooting of hydraulic and pneumatic systems

Which syllabus covers thisAU ME3492 Unit IV (electro-pneumatics, ladder diagram, timers), Unit V (maintenance, troubleshooting, IoT)VTU not in syllabusSPPU 302054 (PLC and IoT control)MU MESBL601 Group C (electro-pneumatic circuits, PLC)KTU MET397 Module 5 (relays, timers, counters, PLC)

What changes when the valves are switched electrically?

Solenoid valves replace pilot signals. Limit valves become limit switches or proximity sensors, and the logic moves into relays or a PLC, drawn as a ladder diagram with timers and counters. The Mechatronics book has a working ladder simulator. Coils draw little power: SMC's SY valves take 0.35 W, or 0.1 W with the power-saving circuit, which is 14.6 mA and 4.2 mA at 24 V DC. That is why one PLC output card can drive a whole manifold. Sequences change in software, not by re-piping.

What must be done before a new hydraulic system runs under load?

Flush the pipes through a filter until the oil meets its cleanliness target, because assembly leaves chips and scale. Fill through a filter and bleed the air at the high points with the system at low pressure. Air ruins stiffness: 1 % free air drops the effective bulk modulus from 1.5 to 1.443 GPa at 100 bar, and to 0.539 GPa at 10 bar. Set the relief low, run each actuator slowly through its stroke, then raise the settings and record the gauge readings as a baseline.

What does a maintenance schedule for a press power pack check?

Change filters on their pressure-drop indicator, not on the calendar. Sample the oil for particle count, water and viscosity. Watch the oil temperature: at 70 °C THE OIL is 15.4 mm²/s, below the AZPF gear pump's recommended 20-100 mm²/s (permitted 12-800), so it leaks more and wears faster. Check the pump inlet gauge: the AZPF needs at least 0.7 bar absolute at its suction port. Note cycle times and pressures against the baseline. On the air side, drain the traps daily and run the leak test monthly, as BEE asks.

How do you find a fault on a hydraulic press from its gauges and cycle?

Compare readings with the healthy baseline. Slow rapid strokes with normal pressures point to lost flow: with the unloading valve stuck open, the approach takes 37.3 s instead of 7.46 s. If the force is short and the pump gauge sits at the relief setting, suspect the relief: at 150 bar the press makes only 302 kN. An inlet gauge at −0.4 bar (0.61 bar absolute) means a choked strainer and a cavitating pump. Try each fault, then use quiz mode.

Fault finding on the press circuit: inject a fault, read the gauges and the cycle, and find what is wrong: interactive loads as you scroll

What can sensors and IoT add to maintenance?

Pressure transducers, temperature sensors and an inline particle counter can log every cycle instead of a monthly walk-round. A simple rule already catches slow faults: alarm when the cycle runs 5 % over the baseline, 18.7 s for THE PRESS. A worn pump (21.4 s) or hot thin oil (19.3 s) trips it long before parts break. Small presses often use a packaged power pack (motor, pump, tank, valves on one block): the same checks apply.

Predict, then check

THE PRESS stalls at 302 kN instead of 400 kN. The pump gauge reads 150 bar at dwell and the relief valve hisses. Which fault?

Worked examples

Unloading valve stuck open · THE PRESS: cylinder 160/100 mm, pumps 8 + 32 cm³/rev at 1,450 rpm, ηv 0.92; approach 330 mm, pressing 30 mm, dwell 2 s, return 360 mm. The big pump's unloader is stuck open, so it always dumps to tank.
  1. Small pump flow = 8 × 1,450/1,000 × 0.92 = 10.672 L/min; healthy approach uses 53.36 L/min.
  2. Approach on the small pump: v = 10.672/60,000/0.020106 = 8.85 mm/s, t = 330/8.85 = 37.3 s (healthy 7.46 s).
  3. Return on the small pump: v = 10.672/60,000/0.012252 = 14.52 mm/s, t = 24.8 s (healthy 4.96 s).
  4. Pressing and dwell unchanged: 3.39 + 2 s.
  5. Cycle = 67.49 s, 53 strokes an hour instead of 202.

Answer: Full force, but a 67.5 s cycle: output falls from 202 to 53 strokes an hour.

Worn pump, ηv down to 0.75 · Same press; both pumps now deliver 75 % of their geometric flow at every pressure.
  1. Flows: small 8.7 L/min, both 43.5 L/min.
  2. Approach t = 330 mm ÷ (43.5/60,000/0.020106) = 9.15 s.
  3. Pressing t = 30 mm ÷ (8.7/60,000/0.020106) = 4.16 s.
  4. Return t = 360 mm ÷ (43.5/60,000/0.012252) = 6.08 s.
  5. Cycle = 21.4 s (168 strokes/h). The pressure still reaches 198.9 bar, so the force is fine.

Answer: Cycle 21.4 s instead of 17.81 s, 5 % alarm (18.7 s) tripped; force unchanged.

Piston seal bypass during pressing · A worn piston seal leaks 0.03 L/min per bar from the cap to the rod side. Pressing: the small pump's 10.672 L/min, pressure rising linearly from 20 to 198.94 bar over 30 mm.
  1. Leak at full force = 0.03 × 198.94 = 5.97 L/min, 56 % of the pump flow.
  2. Speed v = (Q − k p)/A1 with p = 20 + 5.965 s (s in mm), so dt = A1 ds/(Q − k p).
  3. Integrate: t = (A1/(k × 5.965)) ln((Q − 20k)/(Q − 198.94k)) = 5.13 s (healthy 3.39 s).
  4. Stall pressure where the leak takes all the flow = 10.672/0.03 = 356 bar: above the 210 bar relief, so the force is still reached.

Answer: Pressing slows from 3.39 to 5.13 s and the platen creeps when held; replace the seals.

Keep going

Recommended reading

  • Fluid Power with Applications, Anthony Esposito
  • Fluid Power: Theory and Applications, James A. Sullivan
  • Oil Hydraulic Systems: Principles and Maintenance, S. R. Majumdar
  • Pneumatic Systems: Principles and Maintenance, S. R. Majumdar
  • Hydraulic and Pneumatic Controls, R. Srinivasan
  • Pneumatics: Concepts, Design and Applications, T. Jagadeesha

How this book was made

Chapters follow the official syllabi listed above. Every interactive's formulas and every worked-example number were checked by script. Explanations, animations and examples are original to Skill-Lync.

From the exam to a core job

Talk to a counsellor.

Ask how hydraulic and automation engineers use hydraulics and pneumatics on real projects, and what the PG Certification in Embedded Systems covers.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.