Challenge

Week 9 Challenge

Objective

Run a cool analysis on the ruler geometry. Compare the result of the cool analysis by using a normal cooling circuit and a chiller circuit and also check the deflection based on the choice of cooling circuit.

Procedure

Following are the process to get the result:

  1. Create a normal cooling circuit and chiller circuit:

Details of normal cooling circuit:

Method of creation

Manual

Cross section

Circular

Diameter

6mm

Details of chiller circuit:

Method of creation

Manual

Cross section

Circular

Diameter

6mm

Chiller property type

channel

Chiller material

Beryllium cooper

Chiller diameter

8mm

Fig: normal cooling circuit.

Fig: chiller circuit

  1. Set analysis sequence to “cool+fill+pack+warp”.
  1. Select material as “valox 365”.
  1. Set injection location for coolant flow:

Fig: coolant inlet of normal cooling circuit

Fig: coolant inlet and outlet of chiller circuit

  1. Select coolant as “oil”.
  2. Process setting:

Details:

Melt temperature

301°C

Mold open time

3 second

Injection+packing+cooling time

12 second

Filling control

Injection time = 0.7 second

Volume/pressure switch control

By %volume filled = 98%

Pack/holding control

%filling pressure vs time:

Duration

%filling pressure

0.2

80

3

80

1

60

  1. Run the analysis:

cool and deflection results:

Cool analysis results

Normal cooling circuit values

Chiller circuit values

Circuit coolant temperature

25°c

25°c

Circuit flow rate

1971.7 lit/min

2629.0 lit/min

Circuit Reynold number

10000

13333

Circuit metal temperature

27.99°c

40.92°c

Temperature at surface, cold runner

50.24°c

49.79°c

Time to reach ejection temperature, part

22.51 sec

22.50 sec

Time to reach ejection temperature, cold runner

23.10 sec

23.36 sec

Temperature, maximum, part

207.5°c

207.6°c

Temperature, maximum, cold runner

225°c

226.8°c

Average temperature, part

152.6°c

152.7°c

Average temperature, cold runner

170.5°c

171.4°c

Temperature profile, part

207.5

207.6

Temperature profile, cold runner

225

226.8

Circuit minor loss coefficient

1.056

2.022

Circuit friction factor

0.0423

64

Temperature, mold

57.20°c

57.56°c

Temperature, part

71.92°c

72.24°c

Flux, part

48486 w/m²

48469 w/m²

Deflection, all effects

3.217 mm

3.181 mm

Learning outcomes

Following are the things that I have learned in this challenge are:

  1. Cooling insert are used in a place were channels are incapable to produce cooling.
  2. Channels can made by manual meshing method or manual beam creation method.
  3. Orientation defects are diagnosed by “orient all” feature.
  4. Solution for “error 702281” is to indicate the coolant outlets.
  5. Solution for “error 702310” is to change the property type of the element.
  6. According to my observation on the part with chiller circuit and with normal cooling circuit it was found that part with chiller circuit is better, following are the reasons:
  • It tends to give high circuit flow rate.
  • Circuit absorbs more amount of heat from the part.
  • It helps in providing lower deflection to the part.

Conclusion

The challenge was somehow tricky in finding the better circuit for the part. And also, it helps me in performing result interpretation. The whole process gives me the feeling of real life designing of the part. The main thing which I like in this challenge is use of chiller circuit. Thanks to skill-lync for helping me in completing this.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.