AIM:
To Calculate the Concrete Mix Design for M35 grade concrete with fly ash & M50 grade concrete without Fly ash
INTRODUCTION:
Concrete mix design is the method of finding the precise proportion of cement, sand and aggregates for concrete to achieve the target strength in structures, therefore concrete mix design can be stated as concrete mix in terms of cement: sand: aggregates. The design is done according to the requirements of concrete strength. So, we can achieve the desirable properties of concrete either it is in fresh stage or in hardened stage. The fresh concrete properties like workability, setting time and hardened concrete properties like compressive strength, durability etc. are attained surely by this method. Use of additives like admixtures, retarders etc. other than basic ingredients are used to improve the properties of mix. This project consist of two parts, the first part deals with the design of M35 grade cement with fly ash as a part of it and second part is the design of M50 grade concrete without fly ash.
OBJECTIVE:
The objective of this project is to produce a mix design for M35 grade concrete containing fly ash and M50 grade concrete. The mix will be prepared as per IS METHOD: Concrete mix proportioning guidelines from IS 10262:2009 and recommented guide lines from IS 10262:1982.
EQUATION USED:
1)Target mean strength
f’ck =fck + 1.65s
Where
f’ck = target average compressive strength at 28 days
fck = characteristics compressive strength at 28 days, and
s = standard deviation
2)Cement content
Cement content = water content / water-cement ratio
3) Volume Calculations
(a) Volume of concrete
(b) Volume of cement = [Mass of cement] / [Specific Gravity of Cement] x 1/1000
(c) Volume of water = [Mass of water] / [Specific Gravity of water] x 1/1000
(d)Volume of chemical admixture = [Mass of admixture] / [Specific Gravity of admixture] x 1/1000
(e) Volume of all in aggregate =[a-(b+c+d)]
(f) Mass of coarse aggregate= e x Volume of Coarse Aggregate x Specific Gravity of Fine Aggregate x 1000
(g) Mass of fine aggregate= e x Volume of Fine Aggregate x Specific Gravity of Fine Aggregate x 1000
PART 1:To Calculate the Concrete Mix Design for M35 grade concrete with fly ash:
M35 grade concrete with Fly ash
STEP 1: Stipulations for Concrete design mix
Grade designation M35
Type of cement OPC 43 Grade confirming to IS 8112
Type of mineral admixture Fly ash confirming to IS 3812 (Part 1)
Maximum nominal size of aggregate 20 mm
Minimum cement content 320 kg/m3 (Table 5 of IS 456:2000- Exposure condition)
Maximum water-cement ratio 0.45 (Table 5 of IS 456:2000 Exposure condition)
Workability 100 mm (slump value for pumpable concrete)
Exposure condition Severe (For Reinforced Concrete)
Method of concrete placing Pumping
Degree of supervision Good
Type of aggregate Crushed Angular Aggregates
Maximum cement content 450 kg/m3
Chemical admixture type Super Plasticizer
STEP 2: TEST DATA FOR MATERIALS
Cement used OPC 43 Grade conforming IS 8112
Specific gravity of cement 3.15
Fly ash confirming to IS 3812 (Part 1)
Specific gravity of fly ash 2.2
Chemical admixture Super Plasticizer conforming to IS 9103
Specific gravity of coarse aggregate 2.74
Specific gravity of fine aggregate 2.74
Water absorption of coarse aggregate 0.5%
Water absorption of fine aggregate 1.0%
Free surface moisture of Coarse aggregate Nil
Free surface moisture of Coarse aggregate Nil
Sieve analysis: Coarse aggregate Conforming to Table 2 of IS 383
Sieve analysis: Fine aggregate Conforming to Grading Zone II of Table 4 of IS 383
STEP 3: TARGET STRENGTH FOR MIX PROPORTIONING
f’ck =fck + 1.65s
Where
f’ck = target average compressive strength at 28 days
fck = characteristics compressive strength at 28 days, and
s = standard deviation
From Table I of IS 10262:2009, Standard Deviation, s = 5 N/mm2.
35 + 1.65 x 5 = 43.25 N/mm2
Target mean strength = 43.25 N/mm2
STEP 4: SELECTION OF WATER-CEMENT RATIO
The maximum water-cement ratio to design M50 grade concrete can be found from Table 5 of IS 456-2000.
Maximum W/C ratio =0.45
Based on experience adopted water cement ratio is .44
0.44<0.45, hence ok
Adopted W/C ratio=0.44
STEP 5: SELECTION OF WATER CONTENT
From Table 2 of IS 10262:2009, maximum 186 liter (for 25to 50mm)water content for 20 mm aggregate
Clause 4.2 suggests increasing of 3% of water content for every extra 25mm slump from 50mm slump. So a 6% is to be added to it
186+ (6/100)*186 = 197 litre
Estimated water content for 100 mm slump
(Note: If Super plasticizer is used, the water content can be reduced up to 20% and above.)
Based on trials with Super
197*0.8 = 158 litre
plasticizer water content reduction of 20% has been achieved, Hence the arrived water content
Water required 158 litres
STEP 6: CALCULATION OF CEMENT AND FLY ASH REQUIRED
Adopted w/c Ratio 0.44
Total cementitious (Cement + fly ash)requirement =158/0.44 = 359 kg/m3
Water content/ Water Cement ratio
The cementitious content has to be increased in order to attain good workability and strength. The increment required is determined on the basis of experience and research. Here we are increasing cementitious content by 10%
Final cementitious content 359 X 1.10 = 395 kg
From Table 5 of IS 456, Minimum cement content for ‘Severe’ exposure conditions
=320 kg
395 kg/m3 > 320 kg/m3 hence ok.
Cementitious material content 395
New water cement ratio 158/395 =0.4
Fly ash content is taken as 30% of the total cementitious content 395 X .3 = 118.5 kg/m3
Cement required 395 – 118 = 277 kg/m3
Cement quantity saved due to fly ash addition 350-277 = 73 kg/m3
Cementitious material, cement and fly ash required is 395 kg/m3 , 277 kg/m3and 118 kg/m3 and the new water-cement ratio is 0.4 respectively
STEP 7: VOLUME OF COARSE AGGREGATE AND FINE AGGREGATE CONTENT
From Table 3 of (IS 10262:2009) Volume of coarse aggregate corresponding to 20 mm size aggregate and fine aggregate (Zone II) for water-cement ratio of 0.50 is =0.62.
In the present case water-cement ratio is 0.44. Therefore, volume of coarse aggregate is required to be increased to decrease the fine aggregate content. As the water-cement ratio is lower by 0.06. The proportion of volume of coarse aggregate is increased by 0.02 (at the rate of -/+ 0.01 for every ± 0.05 change in water-cement ratio).
Therefore, corrected proportion of volume of coarse aggregate for the water-cement ratio of 0.44
=0.632
For pumpable concrete these values should be reduced up to 10%. Therefore, volume of coarse aggregate
0.632 x 0.9 =0.568.
Volume of fine aggregate content
1 – 0.568 =0.431
Volume of fine aggregate and coarse aggregate is 0.431 and .568
STEP 8: MIX CALCULATIONS
The mix calculations as per unit volume of concrete shall be as follows:
a) Volume of concrete 1 m3
b) Volume of cement = [Mass of cement] / [Specific Gravity of Cement] x 1/1000
(277/3.15) X (1/1000) =0.087m3
c) Volume of fly ash = [Mass of fly ash] / [Specific Gravity of fly ash] x 1/1000
(118/2.2) X (1/1000) =0.053
d) Volume of water = [Mass of water] / [Specific Gravity of water] x 1/1000
(158/1) X (1/1000) = 0.158m3
e) Volume of chemical admixture = [Mass of admixture] / [Specific Gravity of admixture] x 1/1000
(7.6/1.145) X (1/1000) =0.006 m3
f) Volume of all in aggregate =[a-(b+c+d+e)]
[1-(0.087+0.053+0.158+0.006)] = 0.696m3
g) Mass of coarse aggregate= f x Volume of Coarse Aggregate x Specific Gravity of Fine Aggregate x 1000
0.696x 0.568 x 2.74 x 1000 = 1077 kg/m3
h) Mass of fine aggregate= f x Volume of Fine Aggregate x Specific Gravity of Fine Aggregate x 1000
0.696x 0.431x 2.74 x 1000 = 822 kg/m3
STEP 9: MIX PROPORTIONS
Cement
277 kg/m3
Fly ash
118 kg/m3
Water
158 l/m3
Fine aggregate
822 kg/m3
Coarse aggregate 20mm
1077 kg/m3
Chemical admixture
7.18 kg/m3
Water-cement ratio (lowest W/C ratio is selected)
0.4
Mix Proportion By weight
1:2.08:2.72
STEP 10: The slump shall be measured, the water content and dosage of admixture shall be adjusted for achieving the required slump on trial. The mix proportion shall be reworked for the actual water content and checked for durability requirements
STEP 11: Two more trials having variation of 10% of water-cement ratio shall be carried out and a graph between three water- cement ratios and corresponding strengths shall be plotted to work out the mix proportions for the given target for field trials.
PART 2:To Calculate the Concrete Mix Design for M50 grade concrete without fly ash:
M50 grade concrete without Fly ash
STEP 1: Stipulations for Concrete design mix
Grade designation
M50
Type of cement
OPC 53 Grade confirming to IS BIS 12269 - 1987
Maximum nominal size of aggregate
20 mm
Minimum cement content
320 kg/m3 (Table 5 of IS 456:2000- Exposure condition)
Maximum water-cement ratio
0.45 (Table 5 of IS 456:2000 Exposure condition)
Workability
100 mm (slump value for pumpable concrete)
Exposure condition
Severe (For Reinforced Concrete)
Method of concrete placing
Pumping
Degree of supervision
Good
Type of aggregate
Crushed Angular Aggregates
Maximum cement content
450 kg/m3
Chemical admixture type
Super Plasticizer
STEP 2: TEST DATA FOR MATERIALS
Cement used
OPC 53 Grade conforming IS 12269-1987
Specific gravity of cement
3.15
Chemical admixture
Super Plasticizer conforming to IS 9103
Specific gravity of coarse aggregate
2.74
Specific gravity of fine aggregate
2.64
Water absorption of coarse aggregate
0.5%
Water absorption of fine aggregate
1.0%
Free surface moisture of Coarse aggregate
Nil
Free surface moisture of Coarse aggregate
Nil
Sieve analysis: Coarse aggregate
Conforming to Table 2 of IS 383
Sieve analysis: Fine aggregate
Conforming to Grading Zone II of Table 4 of IS 383
STEP 3: TARGET STRENGTH FOR MIX PROPORTIONING
f’ck =fck + 1.65s
Where
· f’ck = target average compressive strength at 28 days
· fck = characteristics compressive strength at 28 days, and
50 + 1.65 x 5 = 58.25 N/mm2
· s = standard deviation
From Table I of IS 10262:2009, Standard Deviation, s = 5 N/mm2.
Target mean strength = 58.25 N/mm2
STEP 4: SELECTION OF WATER-CEMENT RATIO
The maximum water-cement ratio to design M50 grade concrete can be found from Table 5 of IS 456-2000 for severe exposure.
Maximum W/C ratio =0.45
Based on experience adopted water cement ratio is .44
0.44<0.45, hence ok
Adopted W/C ratio=0.44
STEP 5: SELECTION OF WATER CONTENT
From Table 2 of IS 10262:2009, maximum water content for 20 mm aggregate
186 litre (for 25 to 50 mm slump range)
Clause 4.2 suggests increasing of 3% of water content for every extra 25mm slump from 50mm slump. So a 6% is to be added to it
186+ (6/100)*186 = 197 litre
Estimated water content for 100 mm slump
(Note: If Super plasticizer is used, the water content can be reduced up to 20% and above.)
Based on trials with Super
197 X 0.8 = 158 litre
plasticizer water content reduction of 20% has been achieved, Hence the arrived water content
Water required 158 litres
STEP 6: CALCULATION OF CEMENT REQUIRED
Adopted w/c Ratio
0.44
Cement Content
158/0.44 = 359 kg/m3
From Table 5 of IS 456, Minimum cement content for ‘Severe’ exposure conditions
320kg/m3
359 kg/m3 > 320 kg/m3 hence ok.
Cement required is 359 kg/m3
STEP 7: VOLUME OF COARSE AGGREGATE AND FINE AGGREGATE CONTENT
From Table 3 of (IS 10262:2009) Volume of coarse aggregate corresponding to 20 mm size aggregate and fine aggregate (Zone II) for water-cement ratio of 0.50 is
0.62.
In the present case water-cement ratio is 0.44. Therefore, volume of coarse aggregate is required to be increased to decrease the fine aggregate content. As the water-cement ratio is lower by 0.06. The proportion of volume of coarse aggregate is increased by 0.02 (at the rate of -/+ 0.01 for every ± 0.05 change in water-cement ratio).
Therefore, corrected proportion of volume of coarse aggregate for the water-cement ratio of 0.44
0.632
For pumpable concrete these values should be reduced up to 10%. Therefore, volume of coarse aggregate
0.632 x 0.9 =0.568.
Volume of fine aggregate content
1 – 0.576 =0.431
Volume of fine aggregate and coarse aggregate is 0.431 and .568 respectively
STEP 8: MIX CALCULATIONS
The mix calculations per unit volume of concrete shall be as follows:
a) Volume of concrete
1 m3
b) Volume of cement = [Mass of cement] / [Specific Gravity of Cement] x 1/1000
(359/3.15) X (1/1000) =0.114m3
c) Volume of water = [Mass of water] / [Specific Gravity of water] x 1/1000
(158/1) X (1/1000) = 0.158m3
d) Volume of chemical admixture = [Mass of admixture] / [Specific Gravity of admixture] x 1/1000
(7.6/1.145) X (1/1000) =0.006 m3
e) Volume of all in aggregate =[a-(b+c+d)]
[1-(0.114+0.158+0.006)] = 0.722m3
f) Mass of coarse aggregate= e x Volume of Coarse Aggregate x Specific Gravity of Fine Aggregate x 1000
0.722x 0.568 x 2.74 x 1000 = 1123 kg/m3
g) Mass of fine aggregate= e x Volume of Fine Aggregate x Specific Gravity of Fine Aggregate x 1000
0.722x 0.431x 2.64 x 1000 = 821 kg/m3
STEP 9: MIX PROPORTIONS
Cement
359 kg/m3
Water
158 l/m3
Fine aggregate
821 kg/m3
Coarse aggregate 20mm
1123 kg/m3
Chemical admixture
7.18kg/m3
Water-cement ratio
0.44
Mix Proportion By weight
1:2.28:3.12
STEP 10: The slump shall be measured, the water content and dosage of admixture shall be adjusted for achieving the required slump on trial. The mix proportion shall be reworked for the actual water content and checked for durability requirements
STEP 11: Two more trials having variation of 10% of water-cement ratio shall be carried out and a graph between three water- cement ratios and corresponding strengths shall be plotted to work out the mix proportions for the given target for field trials.
RESULTS:
Mix Proportion by weight of M35 grade of concrete with fly ash is 1:2.08:2.72 and its water-cement ratio was found to be 0.4.
Mix Proportion by weight of M50 grade of concrete without fly ash is 1:2.28:3.12 and its water-cement ratio was found to be 0.44