Challenge

Project 1_Analyze and design a steel building to 10T CRANE as per IS standard code using TEKLA STRUCTURAL DESIGNER.

Aim- To design and analyse a steel building

  • Thickness of wall as 150mm
  • Wind speed assumption is 39 m/s
  • Wall and roof loading is 1.5 KN/m2
  • Live load and euipment loads as per IS 875 Part 2
  • Wind load as per IS875 Part 3

Procedure:-

  • To model The structure 
  • Define construction levels
  • Define levels as per cross section

  • to define gridlines
  • click on gridlines icon in the model toolbar
  • specify the first point and draw the first grid line
  • then select parallel quick option and draw all other gridlines by specifying the distance

  • to add supports to the column base
  • to add concrete pedastals to the column base
  • go to manage property sets from the home toolbar
  • click on new> concrete column
  • modify the propeties of the concrete column and click on ok
  • now go to model>click on column>  precast
  • select the column properties from the properties dialoguebox
  • assign them to the column base

  • to assign steel columns
  • go to manage property sets>new> steel column
  • now select the cross section of the steel column
  • add columns to the model
  • to model beams
  • define the properties of the beam in manage property sets
  • assign them to the model

  •  to add wall panels and roof panels to the model
  •  

To add slab panels 

  • to add load cases

LOAD CALCULATIONS

Calculation of brick wall load

  • assume the unit weight of the brick as 20 kn/m^3
  • height of the brickwall is 5m
  • thickness of the brickwall is 150mm
  • load of brick wall is 20 x 5 x 0.15 = 15 kn/m
  • brick wall load on first floor beam is 7 x 20 x 0.15 = 21 kn/m

Calculation of floor finishes

  • assume the thickness of the floor finishes as 50mm
  • unit weight of the floor finishes is assumed as 24 kn/m^3
  • floor finishes load is 0.05 x 24 =1.2 kn/m^2

Calculation of imposed loads

  • imposed loads are considered as per IS 875 part 2 based on occupany

Calculation of wind loads(as per IS 875 part 3)

  • basic wind speed is considered as 39 m/s
  • assume the design life of the structure as 50 years
  • terrain category as 2

Design wind speed

  • K1 probability factor is assumed as 1 (as per IS 5.3.1)
  • K2 terrain and height factor is assumed as 1
  • K3 topography factor is assumed as 1 (for slope of structure greater than 3)
  • K4 importance factor for industrial building is taken as 1.15

design wind speed Vz = 39 x 1 x 1 x 1.15 x 1

design wind speed = 44.85

design wind pressure Pz =0.6 x 44.85^2

design wind pressure 1206.9 N/m^2= 1.2 kn/m

  • total length of the building is 90m
  • width of the structure is 38m
  • height of the structure is 12.5m

Ratio of wall and roof co efficients

l/w = 90/38 = 2.36

h/w = 12.5/38 =0.328

wind load calculations( +Y direction face A )

                                                          +Cpi                       -Cpi

external pressure coefficient                     0.7                    0.7

internal pressure coefficient                     0.7                    -0.7

net pressure coefficient                            0                       1.4

design wind pressure                               1.2                    1.2

loading to be applied on the wall                0                     1.75

wind load calculations( +Y  direction face B )

                                                              +Cpi                     -Cpi

external pressure coefficient                    - 0.25                  -0.25

internal pressure coefficient                     0.7                      -0.7

net pressure coefficient                           -0.95                     0.45

design wind pressure                               1.2                    1.2

loading to be applied on the wall             -1.187                   0.562

wind load calculations( +X direction face c )

                                                              +Cpi                     -Cpi

external pressure coefficient                    - 0.6                    -0.6

internal pressure coefficient                     0.7                      -0.7

net pressure coefficient                            1.3                       0.1

design wind pressure                               1.2                       1.2

loading to be applied on the wall             -1.625.                0.125

wind load calculations( +X direction face D )

                                                              +Cpi                     -Cpi

external pressure coefficient                    - 0.6                    -0.6

internal pressure coefficient                     0.7                       -0.7

net pressure coefficient                            -1.3                       0.1

design wind pressure                               1.2                       1.2

loading to be applied on the wall             -1.625.               0.132

wind load calculations( +y direction face EF )

                                                              +Cpi                    -Cpi

external pressure coefficient                    - 0.4                     -0.4

internal pressure coefficient                     0.7                       -0.7

net pressure coefficient                            -1.1                      0.3

design wind pressure                               1.2                       1.2

loading to be applied on the wall             -1.375.                 0.375

wind load calculations( +y direction face GH )

                                                              +Cpi                     -Cpi

external pressure coefficient                    - 0.4                      -0.4

internal pressure coefficient                      0.7                       -0.7

net pressure coefficient                            -1.1                       0.3

design wind pressure                               1.2                       1.2

loading to be applied on the wall             -1.375.               0.375

Crane load calculations:-

crane capacity =100kn

weight of the crab = 35kn

weight of the crane = 160kn

max hook approach = 1m

wheel base= 3m

distance  between c/c gantry rails =20m

distance between c/c gantry columns= 6m

max point load on the crane = 100 +35= 135

self weight of the crane = 160/2 = 80

Your portfolio, next