Challenge

Modelling of 25 storey building with the specified properties using ETABS

1. Model Initialization in ETABS:

  • Open ETABS software.
  • Click on New Model.
  • In the New Model Quick Template dialog, select Custom Grid Spacing.
  • Click Edit Grid Data and set your custom grid spacing.
  • After setting the grid, click OK.

2. Story and Grid Data:

  • Under Story Dimension, click Edit Story Data.
  • Set the story data for the first three stories, with Story 1 as the master story.
  • Right-click on the first column, select Add Story, and click Keep Existing Story Heights.
  • Add 22 more stories (to make it a 25-storey building).
  • Click OK.

3. Defining Materials:

  • Go to Define → Material Properties.
  • Add new material for Concrete (Grade M30).
  • Add new material for Steel Rebars (Fe 415).
  • Click OK.

4. Defining Sections:

  • Go to Define → Section Properties → Frame Sections.

  • Click Add New Property for Beam:

    • Select Rectangular shape and input beam dimensions: 300 × 400 mm.
  • Add a new property for Column:

    • Input the column dimensions: 800 × 800 mm.
  • Click OK.

  • Go to Define → Section Properties → Slab Section.

  • Select Add New Property for the slab, and set the thickness: 150 mm.

5. Defining Load Patterns and Loads:

  • Go to Define → Load Patterns to define the load types.
  • Add load cases for Dead Load, Live Load, and Seismic Load.

6. Defining Mass Source:

  • Go to Define → Mass Source to assign mass to the building based on the load patterns.
  • Define load cases under Define → Load Cases.

7. Creating Load Combinations:

  • Go to Define → Load Combinations to create necessary load combinations based on the seismic requirements (dead load, live load, seismic load, etc.).

8. Drawing the Building:

  • Quick Draw Columns: Use the Quick Draw Column tool to place columns in the model.
  • Quick Draw Beams: Use Quick Draw Beams to place beams.
  • Select the first horizontal and vertical beams and use Edit → Replicate to replicate them across the building.
  • Draw the slab by selecting Quick Slab, ensuring that the slabs in all stories are similar.

9. Assigning Loads:

  • Select all beams and go to Assign → Frame Loads to assign distributed frame loads.
  • Select the slabs and go to Assign → Shell Loads to assign uniform shell loads.
  • Assign Diaphragm to the slabs by selecting the slabs from the Select tab and using Assign → Diaphragm.

10. Running the Analysis:

  • Save the model.
  • Click Run Analysis from the analysis panel.

11. Viewing Results:

  • After the analysis, go to Display → Story Response Plot.
  • Change the display type to Maximum Storey Drift.
  • Select the desired load combination to view the results.

Verification of Seismic Code Requirements:

  • Ensure the building meets seismic design requirements as per IS 1893 (for India) or the relevant seismic code for the region.
  • Review the story drift and base shear from the results to verify that the building is in compliance with the seismic codes.
  • Check if the structural design and load combinations are in line with seismic force distribution, and validate the column and beam design based on seismic load effects

Given data:

Structural Element Sizes:

  • Beams: 300 × 400 mm
  • Columns: 800 × 800 mm
  • Slab: 150 mm thick

Material Properties:

  • Grade of Concrete: M30
  • Grade of Steel Reinforcement Bars: Fe 415

Loading details:

  • Dead Load on beams from infill wall: 10 kN/m (Let us assume the same for roof floor in view of parapet)
  • Live load on floor: 3 KN/m2 (Let us assume the same for roof floor)
  1. a) Buildings are assumed to be pinned at the base
  2. b) All columns in all storey are of the same size
  3. c) All beams in all storeys are of the same size
  4. d) Building is located on Soil type-II and in Zone-III. Assume other factors if required.

Aim:

To model a 25-storey building using ETABS software and verify the seismic code requirement from ETABS analysis.

Procedure:

  • Open ETABS software.
  • Click New model.
  • Give model initialization setting as follow
  • Click ok
  • In the new model quick template dialog box , select custom grid spacing and click Edit grid data
  • Give the following settings in grid system data dialog box.
  • Click ok.
  • Select custom story data under story dimension and click edit story data.
  • Give the story data for first- three story as follow having story 1 as master story.
  • Write click on the first column and select add story and click keep existing story heights.
  • Give number of added story as 22.
  • Click ok
  • The following page opens
  • Click Define--> Material properties
  • Click Add new material for assigning concrete
  • .
  • Click Add new material for assigning Rebars
  • Click ok
  • Click Define--> Section properties--> Frame sections.
  • Select Add new property in the dialog box.
  • Select the concrete shape as rectangular and give the following settings for the Beam
  • Beam property is added.
  • Again, click Add new property for creating property for column.
  • Column property is added.
  • Click--> Section properties--> Slab section
  • Select Add new property and give the following settings.
  • Clickà Define--> Load pattern
  • Define load patterns by its name
  • Click Define--> Mass source
  • Check load cases by click Define-->Load cases.
  • Create load combinations, Define--> Load combinations
  • Create Columns by Quick draw column.
  • Select quick draw beams.
  • Select the first horizontal and vertical beams and go to edit and select replicate.
  • Select first floor in plan view
  • Draw slab using quick slab by having similar stories in the status
  • Select all the beams from select tab
  • Assign frame loads as distributed from assign tab.
  • Select the slabs
  • Assign shell loads as uniform
  • Select the slabs from select tab and assign as diaphragm from assign tab.
  • Click run analysis in the panel after saving the file.

Result:

  • Click Display -->Story response plot. Change the display type to Maximum storey drift and desired combo to see the plots.

Hence, as per the clause 7.11.1.1, the maximum inter-storey drift is limited to 0.004 for each story height, So it is satisfied .