Identification of Cracks
1.
a)
- It is form of flexural failure due to reversal of stress during earthquake.
- During stress reversal, support top experiences comp and bottom experiences tension.
- top comp is managed by slab advantage. bottom tension was not satisfied by the provided reinforcement.
- since the reinforcement got yielded, it can not be repaired.
b)
- it is beam pull out failure due to insufficient development length of reinforcement in joints.
- During earthquake, The horizontal movement of structure makes this condition worse and detached the beam member from column.
- providing anchorage length between two existing concrete is very difficult. so not repairable.
c)
- Its a plastic hinge failure.
- the damage occurred only in the joint zone first of all.
- cyclic lateral loading & stress reversal at the joints led to the damage.
- even the slab participated to its best to handle the tension (slab is severely cracked means it has undergone tension with its flange condition), but unable to control the damage.
- The joint can be strengthened.
2.
a)
- Its a soft storey failure, technically plastic hinge formation.
- due to absence of infill walls at the ground floor , the plastic hinge forms at the top of ground storey columns during lateral movement.
- based on the development of crush of concrete,
- it can be either repairable and non repairable.
b)
- its a pure shear failure.
- inadequate shear reinforcement compels concrete takes all the shear stresses.
c)
- Its a short column failure.
- an additional slab or a beam connected to a column in mid-height leads to this effect.
- this leads to failure especially if the connection is unintentional and not accounted in design.
- the failure given in the picture is not at all repairable