Challenge

Concept on positioning of Columns

Question 1:

Comment on the layout of the framing plan concerning earthquake resistance in the two horizontal directions X or Y (dots are columns, lines depict beams). Look into aspects of symmetry, redundancy and bi-directional stiffness and ductility.

Ans:-

Aspects Of Symmetry:-

Investigation of the framing plan with respect to Symmetry in X-direction -

If we split the plan Vertically half ,it will look mirrored .So we conclude the given plan is symmetric in X-direction.

Investigation of the framing plan with respect to Symmetry in Y-direction -

If we split the plan horizontally half ,it will look mirrored.so we conclude the given plan in symmetric in Y-direction.

Aspects Of Redundancy:-

Investigation of the plan with Respect to Redundancy in X-direction

The column in x-direction are comparatively more and evenly spaced so the structure is more redundant in x-direction .except the top and bottom column rows are having quite longer spans.

Investigation of the plan with Respect to Redundancy in Y-direction

The Column In Y-direction are Comparatively lesser but evenly spaced so the Structure is redundant but lesser than that X-direction.

Aspects Of Bi-directional Stiffness:-

Investigation With Respect To Bi-directional Stiffness

The Columns in horizontal direction are connected with straight to straight Beams. This means ,any lateral load passing from left end of the building will have its path straight till it reaches right end of the building .so no or less possibility of force diversion take place.

The Columns in vertical direction are not connected with straight to straight Beams.so a lateral load passing from south side of building will get diverted to east-west direction to reach next bay. There

will be major force diversion take place with seismic force Y-direction .the framing plan is weak with respect to bi-directional stiffness in Y-direction.

Aspects ductility-

Investigation of the plan with Respect to Ductility-

prime facie, the aspect ratio of the plan clearly hints more column in X-direction compared to Y-direction.it will result in higher stiffness of the building in X-direction ,which would reduce ductility in X-direction, which would reduce ductility in X-axis.

Moreover ,the X-force will easily pass from one bay to its next due to beam alignment .whereas,the y-force will struggle to pass through .the north-south beams are arranged in zig-zig which leads to discontinuous bracing.

Question 2:

What are the possible sources of irregularity in the building shown here? Explain how, as an engineer, each of these irregularities should be dealt with.

Answer:-

Vertical irregularity -

The building plan Area is large in bottom stories.

The floor plan areas are getting reduced with increase in height .

These Building offsets has to be crosschecked with reference to IS-1893-2016 table -6 serial number(iii)

Soft Storey -

The building has uncovered opening space 6th floor .

As there is no occupancy or a partition wall ,this lead to plastic hinge formation at the columns

Slopy base-

The Building Is Constructed on a sloping ground at one side .

This Will Lead to significant Variations in the stiffness .

Question 3:

A 4-storey hotel building has an open ground floor for the restaurant. Story 2 to 4 have one row of rooms along each long side in plan, separated by a corridor. The two short sides of the perimeter are fully in-filled in all storeys, except for certain openings at the ends of the corridor at storeys 2 to 4 and along the right-hand side of the ground floor. There is a staircase near the upper left-hand corner, with straight flights between landings at floor levels and in-between floors. Cross-section dimensions are written next to the member no. in meters.Comment on the features of the structural design and of the layout of infills which are important for earthquake resistance and seismic performance. How do they relate to the almost full collapse of this building (the extreme left-hand bay with the staircase survived, as well as one long-side façade in the rear end, and the frame along the right-hand side in plan).

Answer:-

Open ground floor - This denotes soft storey mechanism acting in the building.

The bays filled with rooms will have higher mass compared to the middle bay left open for corridor. This induces mass irregularity along height uniformly.

This means the building's left and right sides periphery is more stiffer during seismic forces (especially along North-south)

Usually staircase and lift portions are stiffer than other parts because of concentrated concrete elements. So the staircase portion contains more stiffness in the provided building plan.

No framing connection along Y-direction - We could see no structural beams provided along the vertical direction between columns.

Beams connected along column minor axes - The columns are having longer dimension in Y-direction. This means they are more stiffer along y-direction. But the beams are running only along x-direction which would attract much lesser lateral forces and hardly transfers it.

Variation in column sizes - The internal columns are having higher sizes compared to exterior columns. But this will lead to significant difference in lateral drift of columns. So the concrete floor might have suffered heavy out-of-plane shear which would led to collapse.

Your portfolio, next