Analysis of Buckling Phenomena of Cyclone Seperator Stand.

ANALYSIS OF BUCKLING PHENOMENA OF CYCLONE SEPERATOR STAND

AIM:

  • To perform a buckling analysis on a cyclonic separator stand without stiffener
  • Create a metallic stiffener on the legs of the stand and run the analysis to find out the change in the buckling factor of safety.
  • The next step is to run a design study and find the optimum position for the stiffener.
  • Compare the results for all the cases using tables and highlight the best one.

INTRODUCTION:

A model of cyclone separator stand has been provided by skill-lync. This study involves a buckling analysis of cyclone separator with and without stiffener by applying a constant load of 150KN will be applied at the top face of the stand and the results will be noted to find out the change in the buckling factor of safety at the different optimum position for the stiffener using design study.

CASE 1 - BUCKLING ANALYSIS OF CYCLONE SEPERATOR STAND WITHOUT STIFFENER

Design Model:

Buckling analysis study:

Go to Solidworks simulation -> New study -> Buckling analysis.

Material and its properties:

Material - Alloy steel

Model type - Linear elastic isotropic

Default failure criterion - Max von mises stress

Solver - FFEPlus

Properties:

Elastic Modulus - 2.1e+11 N/m^2
Poisson's Ratio - 0.28
Shear Modulus - 7.9e+10 N/m^2
Mass Density - 7700 kg/m^3
Tensile Strength - 723825600 N/m^2
Yield Strength - 620422000 N/m^2
Thermal Expansion Coefficient - 1.3e-05 /K
Thermal Conductivity - 50 W/(m·K)
Specific Heat - 460 J/(kg·K)

Conditions:

Fixtures - Fix the base of the four columns of the stand as shown in the below figure.

External load - 150 KN of the load is applied over the top face of the stand as shown in the below figure

Run and mesh - In default mesh refinement level.

Study parameter:

Study name: Buckling 1

Analysis type: Buckling

Mesh type: Solid Mesh

Solver: FFFEPlus

Element size - 30mm

Jacobian points: 4

Mesh plot quality: High

STUDY RESULT:

Base-line simulation:

:

Fig: Buckling analysis without stiffener

Name Type Min Max Buckling factor of safety
Amplitude

Amplitude plot for mode shape: 1.

(load factor: 9.3933)

0.0000 0.003416 9.3933

Discussion:

From the analysis of the above result, the maximum factor is of safety without stiffener reaches 9.3933. Even though it satisfies our requirements without using the stiffener, but by adding the stiffener we gain a higher factor of safety which leads to an increase in strength.

CASE 2 - BUCKLING ANALYSIS OF CYCLONE SEPERATOR STAND WITH STIFFENER:

Design Model:

The total height of the stand was 2m.

A stiffener is placed over the stand at an offset distance of 1m.

Buckling analysis study:

Go to Solidworks simulation -> New study -> Buckling analysis.

Then, the simulation was started by defining the conditions and applying the external loads as defined in the first case.

Study parameter:

Study name: Buckling 1

Analysis type: Buckling

Mesh type: Solid Mesh

Solver: FFFEPlus

Element size - 30mm

Jacobian points: 4

Mesh plot quality: High

STUDY RESULT:

Base-line simulation:

Name Type Min Max Buckling factor of safety
Amplitude

Amplitude plot for mode shape: 1.

(load factor: 27.799)

0.0000 0.002871 27.799124

Fig: Buckling analysis with stiffener at 1m offset distance

Discussion:

Whereas when the stiffener is attached at an offset distance of 1m the buckling load factor increases to 27.799 as compared to case 1 without stiffener the buckling load factor of 9.399.

COMPARISON OF STIFFENER POSITION AT DIFFERENT OFFSET DISTANCE TO ANALYZE THE MAXIMUM BUCKLING LOAD FACTOR WITHIN 2m

The design study is made to make the stiffener be placed in the right position where the maximum buckling load factor takes place when the load applied.

DESIGN STUDY:

  • Design variable
  • Constraints
  • Goals

Design variable:

Name Type Value Units
Offset distance

Range with step

Min: 250mm Max: 1750mm

Step: 250mm

meters

Constraints:

Name Condition Bounds Study name
Buckling factor of safety 1

is greater than

25 Buckling 1

Goals:

Name Condition Bounds Study name
Buckling factor of safety 2

maximize

25 Buckling 1

Study results:

Using the design study. I found that the optimal position would be to have a stiffener base at a distance of 1000mm from the top of the maximum buckling load factor of 27.799.

Conclusion:

When I added the stiffener at an offset distance of 1000mm, I found that the buckling load factor of safety increases from 9.3933 to 27.799 which is the maximum buckling load factor among all other offset distance which means the component fails only at 27 times greater than the applied force.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.