Analysis of buckling phenomena
ANALYSIS OF BUCKLING PHENOMENA OF CYCLONE SEPERATOR STAND
1. AIM : TO RUN A FINITE ELEMENT ANALYSIS OF BUCKLING PHENOMENA IN CYCLONE SEPERATOR STAND USING SOLIDWORKS SIMULATION.
2. OBJECTIVE :
- To create 3D model of Cyclone separator stand.
- To perform Buckling analysis simulation study for cyclone seperator stand without stiffener.
- To perform Buckling analysis simulation study for cyclone seperator stand with stiffener.
- To obtain the buckling factor of safety.
- To perform a Design study.
- To compare the results and to find the best position for stiffner.
3. OVERVEW :
Cyclonic separation is a method of removing particulates from an air, gas or liquid stream, without the use of filters, through vortex separation using the principle of inertia to remove particulate matter from flue gases. When removing particulate matter from liquid, a hydro cyclone is used; while from gas, a gas cyclone is used. Rotational effects and gravity are used to separate mixtures of solids and fluids. The method can also be used to separate fine droplets of liquid from a gaseous stream. use the principle of inertia to remove particulate matter from flue gases. Cyclone separators is one of many air pollution control devices known as precleaners since they generally remove larger pieces of particulate matter.
4. BODY OF CONTENT :
fIRSTLY, GOING TO create 3D model of cyclone seperator stand (with stifener),
selection material as Alloy Steel,
Applying load,
mesh generation,
Then,going to run simulation and we will get our results.
RESULTS :
Study-1 (cyclone seperator without stiffener)
BUCKLNG AMPLITUDE,
factor of safety,
STUDY-2 (cyclone seperator with stiffener)
BUCKLING AMPLIUDE,
FACTOR OF SAFETY,
COMPArison by design study-
plot -
CONCLUSION : We can conclude from the above comparison plot that the factor of safety increases as the distance is increased, reaches at peak and then decreases.
So, Factor of safety is highest (17.51422) at position ‘900 mm’, that is the best position for the stiffener.