Project

Modelling and simulation of flow through a flowbench using SolidWorks

  • Grid Dependency Test:-In grid dependency test three different mannual global mesh is used as given in table
Case-1 Case-2 Case-3
Nx 30 60 120
Ny 30 60 120
Nz 12 24 48
  1. For Case-1 Velocity Cut Plot:-

\"1vcutplot\"

2. For Case-2 Velocity Cut Plot:-

\"2vcutplot\"

3. For Case-3 Velocity Cut Plot:-

\"3vcutplot\"

  • Conclusion

Comparing the above three figures,we can see the third case shows a better results in terms of velocity variation,So third case is chossen for further analysis.

Effect of valve lift on mass flow rate

VALVE-LIFT(in m) MASS FLOW RATE
0.001 -0.17505
0.002 - 0.31334
0.003 -0.45402
0.004 -0.5931
0.005 -0.71367
0.006 -0.83103
0.007 -0.90207
0.008 -0.96003

* negative sign shows that mass is leaving from the system

  • Plot of Valve Lift vs Mass flow rate:-

\"plot\"

  • Velocity Distribution for lift-0.001 m

\"1\"

  • Velocity Distribution for lift-0.002 m

\"2\"

  • Velocity Distribution for lift-0.003 m

\"3\"

  • Velocity Distribution for lift-0.004 m

\"4\"

  • Velocity Distribution for lift-0.005 m

\"5\"

  • Velocity Distribution for lift-0.006 m

\"6\"

  • Velocity Distribution for lift-0.007 m

\"7\"

  • Velocity Distribution for lift-0.008 m

\"8\"

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.