Modelling and simulation of flow through a flowbench
Aim: In this project, we create a 3D model of a flow bench and run flow analysis & perform the following operations:
- Grid dependence: For this test, we run the simulation for three different grids at a particular valve lift and compare results in order to decide which mesh level is more precise.
- Effect of valve lift on mass flow rate: Here we run a parametric sweep to show the effect of valve lift on mass flow rate for the selected grid level.
Definitions:
- Flow bench: It is a simple device to measure and quantify the amount of air flowing through the cylinder head runners and intake manifolds.
- Valve lift: It is the distance by which the valve is raised from its seated position when it is opened.
Dimensions:
- Cylinder diameter = 5 cm
- Length of the bore = 10 cm
- Inlet manifold diameter = 1.25 cm
- Shell thickness = 1.5 mm
- Lids were created at both ends of the flow-bench.
Procedure:
- A cylinder and valve are created with the given dimensions.
- Valve dimensions are constrained in order to move the valve vertically.
- Inlet total pressure(lid-1): 401325 pa & Outlet static pressure(lid-2): 101325 pa is given at both ends. This pressure difference helps the air to flow towards the lower pressure side.
- A study is made in order to observe the effect of grid level on simulation results and best grid level is chosen for further study.
- A parametric sweep is done for observing the effect of valve lift on the mass flow rate with the best-chosen grid level.
- Global and surface mass flow rate are taken as goals.
- Velocity and pressure cut plots are made for observation.
- Valve lift range: 2-6 mm and grid level: 5 are chosen for the parametric study.
Results:
Grid dependency: Valve lift is taken as 0.004m
| Goal (Value) | Design Point 1 | Design Point 2 | Design Point 3 |
| Level of initial mesh (Automatic Mesh) | 3 | 4 | 5 |
| GG Mass Flow Rate 1 [kg/s] | 0.000134496 | -0.000109739 | -0.000253286 |
| SG Mass Flow Rate 1 [kg/s] | -5.967376687 | -5.134766864 | -4.874011194 |
Grid level: 3
Grid level: 4
Grid level: 5
By the observation the grid level 5 has fewer discontinuities and disturbances hence it is chosen for further studies. Even a high level of the grid can also be chosen for a much better result but it takes much long computation time.
Effect of valve lift on mass flow rate:
For this test the valve lift is taken in the range from 2-6mm and grid level:5 is taken from the above observations.
Valve lift: 2mm
Valve lift: 3mm
Valve lift: 4mm
Valve lift: 5mm
Valve lift: 6mm
Conclusion: With increment in valve lift the pressure drop decreases which is an advantage because lower the pressure drop much better the design of the port.
| Goal (Value) | Design Point 1 | Design Point 2 | Design Point 3 | Design Point 4 | Design Point 5 |
| Valve Lift [m] | 0.002 | 0.003 | 0.004 | 0.005 | 0.006 |
| GG Mass Flow Rate 1 [kg/s] | 1.39253E-05 | -0.001064847 | 1.60634E-05 | -0.000495434 | 2.35706E-05 |
| SG Mass Flow Rate 1 [kg/s] | -3.917664019 | -4.629334198 | -5.445871471 | -6.130338075 | -6.713494898 |
| Velocity (Max)[m/s] | 21.14789224 | 21.70390317 | 23.70802607 | 23.67276183 | 24.48277106 |
| Pressure (Max) [Pa] | 394691.3545 | 386185.3904 | 386921.1753 | 379020.3594 | 375378.3951 |
Obseravtions:
- From the pressure values, we can observe that as the valve lift increase the pressure decreases due to the increase in valve open flow area.
- From the velocity values, we can observe that as the valve lift increase the velocity increases.
- The swirling effect reduces as the valve lift increases can be observed in the velocity cut plots.
- Mass flow rate reduces as the valve lift increases this is because of the resistance to the flow due to the attachment to the valve seat and valve head.
- As the valve lift continue to increase, a larger intake valve opening allows for greater induction mass flow rate which causes the increase of discharge coefficient.