Mixing flow T-Joint
Challenge-1
A comparative steady-state analysis of a mixing T pipe (as shown in fig 1) is done.
Fig.1: T joint with hot and cold fluid (mixing) flow.
Three cases are analyzed as per the description below:
Case-1: Short length pipe with hot inlet air (x-axis) inlet velocity of 3m/s and cold air (y-axis) inlet velocity of 6m/s. The temperature and velocity distribution of the case is as follows:
Case 2: Long length pipe with hot inlet air (x-axis) inlet velocity of 3m/s and cold air (y-axis) inlet velocity of 6m/s. The temperature and velocity distribution of the case is as follows:
Case 3: Short length pipe with hot inlet air (x-axis) inlet velocity of 3m/s and cold air (y-axis) inlet velocity of 12m/s. The temperature and velocity distribution of the case is as follows:
The table of comparison is as follows:
| Cell Count (tetrahedral) | Average outlet temperature (deg. Celsius) | No. of iterations for convergence | |
| Case-1 | 105912 | 20 | 147 |
| Case-2 | 140609 | 20.05 | between 175 to 200 |
| Case-3 | 105912 | 17.5 | between 200 to 250 |
The residual plots for all three cases are shown below:
Case:1
Case 2:
Case 3:
Conclusion:
From the above analysis, it was observed that using a longer length pipe (case 2), an increase in the overage outlet temperature was 0.05 deg-cel, which is 0.25% higher when compared to case 1. But on the other side by increasing the cold air inlet velocity (case 3), we can see a significant drop of 2.5 deg-cel in output air.
Thus it can be concluded that increasing the cold air velocity is a better option to increase the effectiveness of the given T joint.